CREE-LM80测试报告.doc_第1页
CREE-LM80测试报告.doc_第2页
全文预览已结束

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

XLamp XP-E White LEDs (Revision 1) 1. Number of LED light sources tested /LED光源数量试验See individual test reports. 见测试报告2. Description of LED light sources LED光源的描述XLamp XP-E White LEDs (XPEWHT) All measurements provided are LED package measurements. 3. Description of auxiliary equipment 测试设备描述Instrument Systems ISP-500 Integrating Sphere Instrument Systems CAS-140 Spectrometer Keithley 2420 Sourcemeter 4. Operating cycle 循环周期LED packages are driven at constant current. 5. Ambient conditions 环境条件LED packages are operated in environmental control chambers. The temperature of the ambient air around the LED packages is actively controlled by air flowing through the chamber. TA : See individual test reports RH : 45% Air flow : 800 CFM 包装是运作了环境控制室。周围的空气的温度在LED包是乘飞机主动控制流过室。助教:看个人测试报告湿度, 45%空气流动:800 CFM立方英尺每分钟6. Case temperature 情况下温度The case temperature measurement point is shown in the XLamp XP-E Soldering & Handling document (AP25). 如此的温度测量点被证明在XLamp XP-E焊接和处理文件(AP25)。7. Drive current of the LED light source during lifetime test. LED驱动电流See individual test reports. The drive current used during lifetime testing is listed as “Drive Current.” 看个人测试报告。驱动电流用在一生的测试被列为“驱动电流。”8. Initial luminous flux and forward voltage at photometric measurement current 最初的光通量和正向电压度量测量电流在照片See individual test reports. The drive current used for luminous flux, forward voltage and chromaticity measurements is listed as “Measurement Current.” 看个人测试报告。用于驱动电流的光通量,正向电压测量及色度被列为“措施的观点电流。”9. Lumen maintenance data for each individual LED light source 维护数据腔为每个LED光源的See individual test reports. Ambient temperature during luminous flux testing set to 25C 2C. 看个人测试报告。在环境温度测试集光通到25C2C。10. Observation of LED light source failures 观察LED光源的失败No failures occurred during testing. 没有失败发生。11. LED light source monitoring interval LED光源的监测的时间间隔See individual test reports. 12. Photometric measurement uncertainty 光度测量不确定度Cree maintains a tolerance of +/- 2.0% on flux measurements for LM-80 testing. Cree保持一颗宽容+ / - 2.0% LM-80流量测量测试。13. Chromaticity shift reported over the measurement time 色度变化测量报导See individual test reports. Ambient temperature during chromaticity testing set to 25C 2C. 看个人测试报告。环境温度色度测试集在25C2C。Revision: 1 (September 20, 2010) Test Summary Data Set Case Temp. TS Ambient Temp. TA Drive Current IF Average Lumen Maintenance at 6,000 hours Average Chromaticity Shift (uv) at 6,000

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论