REF542plus编程标准.doc_第1页
REF542plus编程标准.doc_第2页
REF542plus编程标准.doc_第3页
REF542plus编程标准.doc_第4页
REF542plus编程标准.doc_第5页
已阅读5页,还剩1页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

REF542plus 编程规范草案为规范化REF542plus的逻辑编程,使之能更容易理解逻辑,规范通讯定义,以及技术支持,制定该编程标准。在编程时,为使将来读图及理解逻辑更容易,要求逻辑按以下规则编写:分页:1 总页:放置一些常量、电度计量模块、按钮等模块2 输入模块BI0-1:按每块卡分页,逻辑里不用的输入口也必须放入备用。3 手车、地刀模块4 断路器控制模块5 保护单元模块(如果保护功能复杂可以分两页完成)6 输出模块BO0-1:按每块卡分页,逻辑里不用的输出口也必须放入备用。7 LED灯模块:按每页八盏灯分,Alarm灯放在灯的第一页。每页逻辑里面必须排满八个LED灯,以方便通讯连读。Filed bus address:由于该设置与通讯以及事件有着密切关系,所以必须按所附表格定义。NameFiled bus addressCircuit breaker10ZS1CB Truck15Earthing switch16Circuit breaker10ZX2Three position switch 18Three position switch 29NameFiled busaddressNameFiled busaddressNameFiled busaddressBI01BI1525BI2939BI02BI1626BI3040BI0313BI1727BI3141BI0414BI1828BI3242BI0511BI1929BI3343BI0612BI2030BI3444BI0717BI2131BI3545BI0818BI2232BI3646BI0919BI2333BI3747BI1020BI2434BI3848BI1121BI2535BI3949BI1222BI2636BI405BI1323BI2737BI416BI1424BI2838BI427输出口以输出口的号加110来定filed bus address,举例:BO03的filed bus address=3+110=113event:在配置里必须使EVENT有效,以便监控系统能读取事件。System event:输入模块的EVENT需全选。保护模块需选择启动、跳闸的event。输入输出口及LED灯:ZX2:I/OFUNCTIONBI 1C. breaker openBI 2C. breaker closeBI 3Closing springs charged BI 4I Disconnector openBI 5I Disconnector closeBI 6I Earthing switch openBI 7I Earthing switch closeBI 8I Earthing switch close (mechanical contact close)BI 9II Disconnector openBI 10II Disconnector closeBI 11II Earthing switch openBI 12II Earthing switch closeBI 13II Earthing switch close (mechanical contact close)BI 14CB compartment gas pressure is okBI 15I BB compartment gas pressure is okBI 16II BB compartment gas pressure is okBI 17Miniature Circuit Breakers close (Normally open contacts in serial)BI 18Miniature Circuit Breakers open (Normally close contacts in serial for maintenance earthing)BI 19SpareBI 20SpareBI 21SpareBI 22Bustie panel earthing switch open (for feeder panel)BI 23BB I all disconnector open (for bustie panel)BI 24BB II all disconnector open (for bustie panel)BI 25BB I BB CB compartment ARC faultBI 26BB I BB compartment ARC faultBI 27BB II BB CB compartment ARC faultBI 28BB II BB compartment ARC faultBO 1CB closeBO 2CB openBO 3Three position switch open/close operationBO 4Three position switch open/close operationBO 5Three position switch open/close operationBO 6Three position switch open/close operationBO 7Charge motor BO 8SpareBO 9SpareWD 1WatchdogBO 10SpareBO 11MCB trip commandBO 12Three position switch open/close operationBO 13Three position switch open/close operationBO 14Three position switch open/close operationBO 15Three position switch open/close operationBO 16Disconnector openBO 17BBI earthing switch openBO 18BBII earthing switch openWD 2WatchdogAIS:INPUT FUNCTION1st I/O card (Standard)BI 1C. breaker closedBI 2C. breaker openBI 3C. breaker in service positionBI 4C. breaker in test positionBI 5Earthing switch closedBI 6Earthing switch openBI 7Closing springs charged (if foreseen)BI 8SF6 gas pressure low (HD4, if foreseen)BI 9SF6 gas pressure insufficient (HD4, if foreseen)BI 10Remote close command (if foreseen)BI 11Remote open command (if foreseen)BI 12External trip command (if foreseen)BI 13Miniature Circuit Breakers closed (N.O. contacts in series)BI 14Connector for c. breaker circuits connected2nd I/O card (on request)BI 15Internal Arc detection in Busbar compartments (N.C. contact, if foreseen)BI 16Internal Arc detection in C.B. compartments (N.C. contact, if foreseen)BI 17Internal Arc detection in Cable compartment (N.C. Contact, if foreseen)BI 18Available (signal of customer)BI 19Available (signal of customer)BI 20Available (signal of customer)BI 21Available (signal of customer)BI 22Available (signal of customer)BI 23Available (signal of customer)BI 24Available (signal of customer)BI 25Available (signal of customer)BI 26Available (signal of customer)BI 27Available (signal of customer)BI 28Lock on protective function (if foreseen)OUTPUT FUNCTION1st I/O card (Standard)BO 1C. Breaker close commandBO 2C. Breaker open commandBO 3Protection 1 (tripped signal)BO 4Protection 2 (alarm signal or tripped 2 signal or lock-out function)BO 5Available (signal for customer)BO 7Available (signal for customer)BO 8Trip coil supervision alarmWD 1Watchdog2nd I/O card (on request)BO 9Bus Coupler CB open command (internal arc detection)BO 10Incoming CB open command (internal arc detection)BO 11Locking magnet on c. breaker truck (unlock command operated by REF MMI, if foreseen)BO 12Locking magnet on earthing switch (unlock command operated by REF MMI. if foreseen)BO 13Available (signal for customer)BO 15Lock on protective function (if foreseen)BO 16Locking magnet on c. breaker closing (lock command)WD 2WatchdogLED FUNCTION

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论