



全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
目 录目 录11 故障摘要11.1 故障的系统及配置11.2 故障处理简要12 故障现象(描述故障的总体情况)13 故障分析及处理(记录故障分析及处理)24 目前状况45 总结建议(本次故障处理的总结建议)46 遗留问题(故障处理完毕后尚遗留待处理的问题)41 故障摘要1.1 故障的系统及配置硬件: SUN M4000软件: XSCF,Solaris10 1.2 故障处理简要2011-6-8:发现M4000内存有报警2 故障现象(描述故障的总体情况)远程登录XSCFXSCF showstatus MBU_A Status:Normal;* MEMB#0 Status:Deconfigured;* MEM#0A Status:Deconfigured;* MEM#1A Status:Deconfigured;* MEM#2A Status:Degraded;* MEM#3A Status:Faulted;XSCF showhardconf* MEMB#0 Status:Deconfigured; Ver:0101h; Serial:BF0947H3W8 ; + FRU-Part-Number:CF00541-0545 09 /541-0545-09 ;* MEM#0A Status:Deconfigured; + Code:2c000000000000000818HTF25672PY-667G10100-d36165a1; + Type:2A; Size:2 GB;* MEM#1A Status:Deconfigured; + Code:ce0000000000000001M3 93T5660QZA-CE6 4151-5224785b; + Type:2A; Size:2 GB;* MEM#2A Status:Degraded; + Code:ce0000000000000001M3 93T5660QZA-CE6 4151-5224785e; + Type:2A; Size:2 GB;* MEM#3A Status:Faulted; + Code:ce0000000000000001M3 93T5660QZA-CE6 4151-52247833; + Type:2A; Size:2 GB; MEMB#1 Status:Normal; Ver:0101h; Serial:BF0947H3P2 ; + FRU-Part-Number:CF00541-0545 09 /541-0545-09 ; MEM#0A Status:Normal; + Code:2c000000000000000818HTF25672PY-667G10100-d3616807; + Type:2A; Size:2 GB;3 故障分析及处理(记录故障分析及处理)内存故障,处理过程如下1.首先掉电,然后现场更换状态为Degraded和Faulted的内存,启动后得到如下输出XSCF showstatus* MBU_A Status:Degraded;* MEMB#0 Status:Degraded;2.从原厂申请Service password,例如TOW JOT RAID KAHN STAG SICKNOW CAFE VERY NASH FONT BORNGLOM FUSE OTT EAST SOOT ABLEJAB MORT BULL BAR DUTY MERTCURD SHUN SLIT DEE AX ABE然后XSCF enableserviceService Password: * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *Mode password is: JOEY DISH OILYXSCF serviceMode password: * * *进入service,运行命令serviceclearfault MBU_Aserviceclearfault MBU_A/MEMB#0检验内存是否正常serviceshowstatus MBU_A Status:Normal;* MEMB#1 Status:Deconfigured;* MEM#0A Status:Deconfigured;* MEM#1A Status:Faulted;* MEM#2A Status:Deconfigured;* MEM#3A Status:Deconfigured;3.掉电更换状态为Faulted的内存,重启后得到如下输出XSCF showstatus MBU_A Status:Normal;* MEMB#1 Status:Degraded;* MEM#0A Status:Degraded;清除错误service clearfault MBU_A/MEMB#1XSCF showstatus MBU_A Status:Normal; MEMB#1 Status:Normal;MEM#0A Status:Degraded;serviceclearfault /MBU_A/MEMB#1/MEM#0Aclearfault: Fault cannot be cleared for this FRU.FRU will be marked to clear faulton next circuit breaker off and on.Continue? y|n: YFault will be cleared after circuit breaker off and on第三次掉电重启,黄灯灭,得到如下输出XSCF showstatusNo failures found in System Initialization.进入操作系统XSCF console -d 0Connect to DomainID 0?y|n :y启动后,查看系统硬件信息rootTJANACOL1 # prtdiag -vcouldnt set locale correctlySystem Configuration: Sun Microsystems sun4u Sun SPARC Enterprise M4000 ServerSystem clock frequency: 1012 MHzMemory size: 163
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 湖北省襄阳市城县襄阳东津新区汉水小学2024-2025学年六年级下学期期末数学试题(含答案)
- 抗美援朝课件模板
- 纸牌魔术的题目及答案
- 2024-2025学年河北省保定市安新县雄安新区人教版六年级下册期中测试数学试卷(含答案)
- 2025年医疗康复器材项目建议书
- 2025年领胜上岗考试试题及答案
- 房地产知识培训课件
- 2025年江苏入团考试题目及答案
- 慢性宫颈炎的课件
- 计算机信息系统变更、发布、配置管理制度
- 航空发动机强度与振动:Chapter 4 Vibrations of Disc and Shells (盘和壳体的振动)
- 《英语教师职业技能训练简明教程》全册配套优质教学课件
- 光伏电站组件清洗周边除草治理方案
- 建筑面积测绘报告范本
- 高考语文复习-引号的作用 课件37张
- 农业模型PPT讲稿课件
- 国家开放大学电大专科《政治经济学》网络课机考网考形考单项选择题题库及答案
- 核质保监查员考试复习题(答案)
- Q∕GDW 10356-2020 三相智能电能表型式规范
- 电工电子技术基础教学大纲
- 医学统计学SPSS
评论
0/150
提交评论