血液透析机的基本结构_第1页
血液透析机的基本结构_第2页
血液透析机的基本结构_第3页
血液透析机的基本结构_第4页
血液透析机的基本结构_第5页
已阅读5页,还剩13页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

血液透析机的基本结构,血液透析流程图,血泵,抗凝剂,血液返回患者,血液来自患者,透析器,新鲜透析液,废弃的透析液,2017/12/20,3,透析器透析膜,血液紅血球脂肪蛋白質尿酸尿素肌肝電解質水,透析液細菌病毒電解質水,彌散作用,跨膜壓,弥散,Start:differentconcentrations,End:equal concentrations onboth sides,Diffusion: due to the random movementof all molecules (Brownian Movement),time,SCREEN 2,The various steps of theT1 TEST green highlights the specific part of the test sequence,T1 TestIf an error occurs a x or number appears to inform you of the failure.The alarm occurs at the ENDof the test procedure,血泵,- Automated threading of pump segment- Delivery rate 15 - 600 ml/min (流量)- Inner tube diameter 2 - 10 mm (內徑) (in 0.2 mm steps)- Driven by a microprocessor controlled stepper motor- Including pressure measuring equipment- Exchangeable plug-in module,Arterial pressure monitor connector,Red Alarm,Green, pump operational,Door cover.When open pump stops,Arrow up toincrease pumpspeed,Arrow down to decrease pumpspeed,Blue On/Off key,Magnetic door catch,Press together tochange lumen size e.g. 8.0mm,肝素泵,Anticoagulation: To prevent blood clotting in the extracorporeal blood circuit- Driven by a microprocessor controlled stepper motor- Time programmable (時間設定)- Bolus administration (劑量控制)- Delivery rate 0.1 - 10 ml/h (in 0.1 ml/h steps) (流量)- Exchangeable plug-in module- 20, 30 and 50 ml syringes (大小尺寸)- Warning message 10 min (警示),Arrow UP for RAISING the level in the chamber,The DOOR for securing thechamber into the level detector,VENOUS return Clampautomatically closes following any BLOOD alarm,VENOUS pressuretransducer port,ULTRASONIC level detector sensors,OPTICAL detectorto detect the differencebetween Light and Dark,Arrow DOWN for LOWERINGthe level in the chamber,- Level adjustment (液面調控)- Venous pressure measuring (靜脈壓)- Ultrasonic air bubble detector (超聲波) (22 mm and 30 mm diameter)- Venous clamp (靜脈夾子)- Optical detector (光感)- Exchangeable plug-in module,空氣監測器,透析机常见报警与处理,动脉压,原因血流量不足动脉管受压卷曲插管在血管内壁贴壁穿刺位置不得当,静脉压,原因静脉壶凝血穿刺位置不得当压力监测保护罩堵塞血流量影响,跨膜压,原因透析液管路卷曲快速接头与透析器连接不紧快速接头内橡胶电老化滤器凝血治疗参数的设定,气泡监测,原因滤器排气不达标静脉壶安装不正确过低的静脉压探测器灵敏度偏移探测器损坏,温度报警,原因温度探测器被杂质附着供水不足或流量不稳控温器损坏,电导度报警,原因AB液不正确AB吸液口漏气干粉制

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论