萨特科技贴片保险丝规格书.doc_第1页
萨特科技贴片保险丝规格书.doc_第2页
萨特科技贴片保险丝规格书.doc_第3页
萨特科技贴片保险丝规格书.doc_第4页
萨特科技贴片保险丝规格书.doc_第5页
已阅读5页,还剩43页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Product CatalogNANJING SART SCIENCE & TECHNOLOGY DEVELOPMENT CO.,LTDMaqun Science & Technology Park, Qingma Road 6#, Nanjing, ChinaTel :+86-25-83241391Fax:+86-25-83241791Company IntroductionSART Technologythe first Chinese manufacturer of SMD fusewas founded in 2006SART has devoted itself to research and develop circuit protection devices ever since SARTs facility in Nanjing are certified by TS16949, ISO 9001 and ISO14001Our main products include SMD fuses and Current Sensing Resistors(CSR)Our SMD fuses have been widely used in different applications like LCD panels、battery packs、battery chargers、digital cameras、 cell phones etcSART ceramic 6125 fuses with raw material originated from Germany have the advantage of a higher breaking capacityfacilitating their use in circuits with higher current and voltageOur current sensing resistors(CSR) have great competitive edge in terms of ultra low ohmlow TCR tight tolerancehigh withstanding surge current and low thermal EMFThey are designed for current detecting and can be perfectly utilized by intelligent Li-ion rechargeable batteries With our mission in mindSART has made huge investment in building a strong R&D teama global sales team and an international management team to provide our best service to global customersSARTs mission and commitment are Service: Global sales offices and on-time delivery Affordability: Best quality for best prices available Recognition: Win trust and award from major customers Technology: Innovative technology for the market YOU GIVE US AN OPPORTUNITY; WE PROMISE YOU THE FUTURE!Contentsn Fuse Selection Guide.1Square Ceramic Surface Mount Fusen Fast Acting of S6125-F Series.5Thick Film Surface Mount Fusen Fast Acting of S0603-F Series.9n Slow Blow of S0603-S Series.13n Fast Acting of S1206-F Series.17n Slow Blow of S1206-S Series.21Current Sensing Surface Mount Resistorn Thick Film of SK Series.25l 0603 of SK Seriesl 0805 of SK Seriesl 1206 of SK Seriesl 1210 of SK Seriesl 2010 of SK Seriesl 2512 of SK Seriesn Metal Strip of SM Series.28l 1206 of SM Seriesl 2512 of SM Seriesn Metal Foil of SMF Series.31l 0805 of SMF Seriesl 1206 of SMF Seriesl 2512 of SMF Seriesn Recommended Solder Pad Layout.34n Recommended IR-Reflow Profile.35n Packaging 36n Storage Condition39Fuse Selection GuideThis selection guidelines and product data are intended to provide technical information that will help with selection of fuse. Since these are only a few of the contributing parameters, application testing is strongly recommended and should be used to verify performance in the application circuit.1. Fuse selection DescriptionDuring normal load conditions, the fuse must carry the normal operating current of the circuit without nuisance openings. However, when an overcurrent occurs the fuse must interrupt the overcurrent and withstand the voltage across the fuse after internal arcing. To properly select a fuse the following items must be considered: Application voltage (AC or DC) Normal operating current Ambient temperature Overload conditions and opening times Maximum available fault current Pulse (or Surge current, Inrush current, Start-up current) characteristics Physical size and available board space Standards requirements or environmental protection requestApplication Voltage:The voltage rating of the fuse must be greater than (or equal to) the maximum open circuit voltage Normal operating current: An operating current of 75% or less than rated current of fuse is recommended for operation at 25 to avoid nuisance openings.Ambient temperature: All electrical characteristics of fuse are rated and validated at an ambient temperature of 25.Both higher and lower ambient temperatures will affect the fuses opening and current carrying characteristics. Please refer to the temperature derating curve for individual product series found in the specifications.Overload conditions and opening times: Specific attention must be given to first overload operating points. For fuses, the first overload point is usually between 200% to 300% of rated current.Maximum available fault current: The interrupting rating of fuse must meet or greater than the maximum fault current of the circuit. 1 Fuse Selection GuidePulse current characteristics: Transient Pulse current is used to describe wave shapes that result from any start up, Inrush, Surge, or transient currents in a circuit. Electrical pulses produce thermal cycling and possible mechanical fatigue that could affect the life of the fuse. Initial or start-up pulses are normal for some applications and require the characteristic of a slow blow fuse.The fuses capability to withstand a surge pulse without causing thermal stress to the fuse element, which may result in nuisance openings, can be determined once the circuits pulse I2t is calculated. The circuit designer needs to properly size the fuse so that the fuses melting I2t value is greater than or equal to the pulse I2t divide by a pulse factor Fp.In design the selected fuse should have a I2t value much greater than the I2t value of pulse. The I2t value of a pulse can be approximated from the following formulas for a typical wave Shape, refer to P1.Physical size and available board space: Please refer to the product dimensions presented in Sartfuse product datasheet for specific information (such as 0603/1206/6125).Standards requirements or environmental protection request: Please refer to the product datasheet or contact us, we will supply specially service to you. 2. Flow for Fuse selectionStep1. Measurement of circuit values using actual device. Measure the circuit values, such as operating current, Inrush current waveform, Ambient temperature.Step2. Calculation from operating current.Rated current of fuse Operating current/Rated derating factor: 0.75Temperature derating factor: (Look Temperature Derating Curve P1)Example: Operating current = 1.7A, Ambient temperature = 80 oCChoosing Rated current of fuse 1.7/0.75/0.91 = 2.491A (0.91:Temperature 80 oC derating factor)Temp derating factor %Temperature in degrees oCP1: Chip fuse Temperature Derating Curve 2 Fuse Selection GuideStep3. Consider from overload current. Specific attention must be given to first overload operating points. For fuses, the first overload point is usually between 200% to 300% of rated current. Referring to the I/T curve(Look P2).P2: S1206-F Series I/T curve Steo4. Calculation from inrush current.Choosing Ifuse2t Ipulse2t/0.25 25%(Pulse Factor 100,000 surge Pulses)In design the selected fuse should have a I2t value much greater than the I2t value of pulse.The I2t value of a pulse can be approximated from the following formulas for a typical wave Shape, refer to P3. 3 Fuse Selection GuideStep5. Final determination of rated value From calculation results of step2 through step4 ,determine the rate valueStep6. Operation check using actual device. After selecting the rating, confirm if the device works properly under the pre-determined conditions.ReliabilitySafety 4 Surface Mount Fuses6125Size Fast Acting S6125-F SeriesAgency / Certificate InformationAgencyFile NumberAmpere RangeJDYX2.E319541A20AJDYX8.E319541A20APSE110202971A5APSE110202966.3A10ACertificateFile NumberISO9001:2008J10Q20600R0SISO14001:2004J10E20601R0SISO/TS16949:20090117251General Fast acting,Inrush withstand capability Wire-In-Air performance Wide range of current rating available 6.1mm 2.5mm spuare shape surface mount Higher temperature profiles -50125 operating temperature Excellent environmental integrity RoHS compliant Halogen-freeApplication Battery pack PC related equipment and peripherals (Hard driver , Printer , etc.) Digital camera (Digital still camera) Game equipment LCD monitor , LCD modules Wireless basestation Power supply Medical deviceOrdering Information * Measured at10% rated current and 25 oC 5 * Melting I2T at 10 times of rated currentSurface Mount Fuses6125Size Fast Acting S6125-F SeriesCatalog SymbolCatalo S 6125F1.0A “1.0A” Ampere Rating: 1A“ F” Electrical Characteristic: F = Fast acting“6125” Size Number“ S” Symbol of SARTDimensions Shape & Dimensions: (mm) LWtD1.40.1Unit:mmMaterialsRecommended Land Patterns Recommended Land Patterns: (mm) Materials:BADCComponentsMaterialBodyCeramicTerminationsAu Plated Brass CapElementSilver Plated or Copper Alloy wireDimensionsABCDSpec3.00.38.00.33.0Unit:mm 6 Surface Mount Fuses6125Size Fast Acting S6125-F SeriesTime Current CurveTime Current Curve:Electrical CharacteristicsAmpere Rating% of Current RatingOpening Time1A-20A100% Min.4hr. 1A-10A200% Max.5s12A - 20A200% Max.20sTemperature Derating CurveI2T vs Time Curve 7 Surface Mount Fuses6125Size Fast Acting S6125-F SeriesReliability TestReliability Test:ItemTest condition / MethodsPerformanceStandardTime/Current100% InNo Fusing;4hr min.UL248-14200% In110A 5 s1220A 20 sRefer to SART File1000% In1ms-10msIEC60127-4Voltage Drop100% of its rated current1-6.3A300mv7-10A220mv12A-20A150mvIEC-60127-4Endurance Test125% of its rated current1-6.3A707-10A85IEC-60127-4100% of its rated current12-20A105UL248-14Interrupting Ability 50A/125V AC 160V DC(1A-10A)50A/65VAC/DC(12A-20A)without permanent arcing, ignition and bursting of fuse linkUL248-14IEC60127-4Solderability240oC5 ,3s0.5s95% coverage min.IEC60127-4IEC60068-2-20;MIL-STD-202Resistance to soldering260oC5,10s0.5sR:10%MIL-STD-202 Method 210High TemperatureOperating LifeT=702,0.6In,96hR: 10%MIL-STD-202 Method 108Humidity(steady state)T=402,9095%RH,1000hR: 10%MIL-STD-202 Method 103Low Temperature StorageT=-553,96 hR: 10%IEC60068-2-1High Temperature StorageT=1252,96hR: 10%IEC60068-2-2Salt Spray5% salt solution ,48 hR: 10%MIL-STD-202 Method 101Thermal Shock5 cycles between -55/+125,60 minutes ; each extremeR: Fast Acting S0603-F SeriesAgency / Certificate InformationAgencyFile NumberAmpere RangeJDYX2.E3195400.5A6AJDYX8.E3195400.5A6ACertificateFile NumberISO9001:2008J10Q20600R0SISO14001:2004J10E20601R0SISO/TS16949:20090117251Ordering InformationGeneral Fast Acting 1.6mm0.8mm physical size Thick film manufacturing method, ceramic substrate, silver fusing element -50oC125 oC operating temperature Excellent environmental integrity RoHS compliant Halogen-freeApplication Battery pack PC related equipment and peripherals (Hard driver, Printer, etc.) Portable devices (Mobile phone, PDA battery charger, etc.) Digital camera (Digital still camera) Game equipment LCD monitor, LCD modules Wireless basestation * Measured at10% rated current and 25 oCPart NumberMarkingCurrent Rating (A)Voltage RatingInterruptingRatingMax Cold DCR*()TypicalI2T*(A2S)S0603-F-0.5AF0.532V DC50A/32V DC0.9400.0067S0603-F-0.75AG0.750.4480.0087S0603-F-1.0AH1.00.2520.0150S0603-F-1.5AK1.50.1080.0365S0603-F-2.0AN2.00.0580.0595S0603-F-2.5AO2.50.0430.1222S0603-F-3.0AP3.00.0440.1350S0603-F-3.5AR3.50.0320.1891S0603-F-4.0AS4.032V DC35A/32V DC0.0190.3559S0603-F-5.0AT5.00.01350.7030S0603-F-6.0A66.00.01150.8861 * Melting I2T at 10 times of rated current 9 Surface Mount Fuses0603Size Fast Acting S0603-F SeriesCatalog SymbolCatalo S 0603F1.0A “1.0A” Ampere Rating: 1A“ F” Electrical Characteristic: F = Fast acting“0603” Size Number“ S” Symbol of SARTDimensions Shape & Dimensions: (mm)Unit:mmDimensionsSizeL1.600.15W0.800.15T0.400.10B0.300.20MaterialsRecommended Land Patterns Recommended Land Patterns: (mm) Materials:BADCComponentsMaterialSubstrateCeramicTerminationsSilver over-plated with tin (100%)ElementSilver or Silver / PalladiumDimensionsABCDSpec1.00.23.01.00.3Unit:mm 10 Surface Mount Fuses0603Size Fast Acting S0603-F SeriesTime Current CurveElectrical CharacteristicsAmpere Rating% of Current RatingOpening Time500mA-6A100%4 h 500mA-6A250%5 sTemperature Derating Curve The current carrying capacity will be affected by ambient temperature which was showed in the figure.This current derating curve is for fusing characteristics.Example:Work Temp:80 Temp derating factor = 91% Iactual = Inormal / 0.91 11 I2T vs Time CurveTemperature in degrees Temp derating factor %Surface Mount Fuses0603Size Fast Acting S0603-F SeriesReliability TestItemTest condition / MethodsPerformanceStandardVoltage Drop100% In; Temperature in fuse was stabilizedDeviation between the mean value:15%IEC 60127-1Time/Current100% InNo Fusing;4h min. SART File250% InWithin 5sEndurance Test100% In, 1h on,15min off, 100 cycles;followed by 1h at 125%InR10% Legible appearanceIEC 60127-1Maximum Sustained Dissipation125%In, during the last 10min of the endurance testchanged with current ratingIEC 60127-1Temperature Rise100%InT75UL248-14Interrupting Ability50A /32V DC(500mA-3.5A)35A/32V DC(4A-6A)Without permanent arcing, ignition and bursting of fuse linkUL248-14Solderability240oC5 ,3s0.5s95% coverage min.IEC60127-4IEC60068-2-20MIL-STD-202Resistance toSoldering260oC5,10s0.5sR10%Legible appearanceMIL-STD-202 IEC60127-4Bending TestDistance between holding points:90mm

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论