




已阅读5页,还剩19页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1 STARTSTOP:验*)TestRS( Set := Test_Set, R1 := Test_Reset or Stop_Reset, Q1 = Test_Status );(*启动条件具备*)Start_Allow:=not PE511_L and not PE401_LL and not PI601_L and PSA413 and PSA303 and PSB303 and PdS524 and not Stop_Signal and PE301_H;(*透平申请启动*)StartApplyRS( Set := Start_Allow and Start_Apply, R1 := Stop_Signal or Start_Cancel, Q1 = PDC429 );(*PDC438:=PDC429 and (SE801C_H or SE801A_H or SE801B_H);*)(*系统闭锁解除*)SystermReleaseRS( Set := PDC429 and Start_Allow and PdS567, R1 := Stop_Signal, Q1 = SystermInterlock_Release );(*透平停机条件*)(*透平前轴振动A*)StopSignalRS1( Set := XT801A_HH, R1 := Stop_Reset, Q1 = StopSignal_Cond1 );(*透平前轴振动B*)StopSignalRS16( Set := XT801B_HH, R1 := Stop_Reset, Q1 = StopSignal_Cond16 );(*透平后轴振动A*)StopSignalRS17( Set := XT802A_HH, R1 := Stop_Reset, Q1 = StopSignal_Cond17 );(*透平后轴振动B*)StopSignalRS18( Set := XT802B_HH, R1 := Stop_Reset, Q1 = StopSignal_Cond18 );(*发电机前轴振动B*)StopSignalRS19( Set := XT803B_HH, R1 := Stop_Reset, Q1 = StopSignal_Cond20 );(*发电机前轴振动A*)StopSignalRS2( Set := XT803A_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond2 );(*透平位移A*)StopSignalRS3( Set := ZT801A_HH OR ZT801A_LL, R1 := Stop_Reset, Q1 = StopSignal_Cond3 );(*透平位移B*)StopSignalRS20( Set := ZT801B_HH OR ZT801B_LL, R1 := Stop_Reset, Q1 = StopSignal_Cond20 );(*透平转速*)StopSignalRS4( Set := (SE801A_HH AND SE801B_HH) OR (SE801B_HH AND SE801C_HH) OR (SE801C_HH AND SE801A_HH), R1 := Stop_Reset, Q1 = StopSignal_Cond4 );(*润滑油*)StopSignalRS5( Set := PE401_LL or (PS402A and PS402B) or (PS402A and PS402C) or (PS402B and PS402C), R1 := Stop_Reset, Q1 = StopSignal_Cond5 );(*液压油*)StopSignalRS6( Set := PE511_LL, R1 := Stop_Reset, Q1 = StopSignal_Cond6 );(*透平前轴温度A*)StopSignalRS7( Set := PE201A_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond7 );(*透平前轴温度B*)StopSignalRS21( Set := PE201B_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond21 );(*透平后轴温度A*)StopSignalRS22( Set := PE202A_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond22 );(*透平后轴温度B*)StopSignalRS23( Set := PE202B_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond23 );(*发电机前轴温度*)StopSignalRS8( Set := TISA206_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond8 );(*发电机后轴温度*)StopSignalRS24( Set := TISA207_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond24 );stop_ftrig( Clk := PdS565 );StopSignalRS10( Set := PdS560 or stop_ftrig.Q , R1 := Stop_Reset, Q1 = StopSignal_Cond10 );(*氮气支管压力*)StopSignalRS11( Set := PI601_LL, R1 := Stop_Reset, Q1 = StopSignal_Cond11 );(*紧急停车*)StopSignalRS12( Set := StopSignal_Set OR PDS100, R1 := Stop_Reset, Q1 = StopSignal_Cond12 );(*透平前止推轴温度A*)StopSignalRS13( Set := PE203A_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond13 );(*透平前止推轴温度B*)StopSignalRS9( Set := PE203B_HH, R1 := Stop_Reset, Q1 = StopSignal_Cond9 );(*透平后止推轴温度A*)StopSignalRS24( Set := PE204A_HH , R1 := Stop_Reset, Q1 = StopSignal_Cond24 );(*透平后止推轴温度B*)StopSignalRS25( Set := PE204B_HH, R1 := Stop_Reset, Q1 = StopSignal_Cond25 );(*快切阀关*)QuickCloseRtrig( Clk := PdS521 );StopSignalRS15( Set := QuickCloseRtrig.Q , R1 := Stop_Reset, Q1 = StopSignal_Cond15 );Stop_Signal1:=StopSignal_Cond1 or StopSignal_Cond2 or StopSignal_Cond3 or StopSignal_Cond4 or StopSignal_Cond5 or StopSignal_Cond6 or StopSignal_Cond7 or StopSignal_Cond8 or StopSignal_Cond9 ;Stop_Signal2:=StopSignal_Cond11 or StopSignal_Cond12 or StopSignal_Cond13 or StopSignal_Cond10 or StopSignal_Cond14 or StopSignal_Cond15 or StopSignal_Cond16 or StopSignal_Cond19 or StopSignal_Cond17 or StopSignal_Cond18 ;Stop_Signal3:=StopSignal_Cond21 or StopSignal_Cond22 or StopSignal_Cond23 or StopSignal_Cond24 or StopSignal_Cond25 or StopSignal_Cond26 or StopSignal_Cond27 or StopSignal_Cond20;Stop_Signal:=Stop_Signal1 or Stop_Signal2 or Stop_Signal3;PDC434:=Stop_Signal;PDC436:=Stop_Signal;(*if Stop_Signal then FIC101.Value:=0;end_if;*)StopSignalNormalRS( Set := StopSignal_Normal, R1 := Stop_Reset, Q1 = PDC433 );2 PUMP:(*润滑油辅泵控制*) LubOilAidPump_RS( Set := LubOilAidPump_Start or PE401_l, R1 := LubOilAidPump_Stop or not PdS530, Q1 = PDC401 ); (*润滑油排雾风机启停*)LubOilFan_RS( Set := LubOilFan_Start, R1 := LubOilFan_Stop or not PdS531, Q1 = PDC402 );(*润滑油电加热器启停*)LubOilHeater_RS( Set := LubOilHeater_Start or TIA401_L, R1 := LubOilHeater_Stop or TIA401_H or not PdS532, Q1 = PDC403 );(*液压油1号泵启停*)HydOilPump1_RS( Set := HydOilPump1_Start or PE511_L, R1 := HydOilPump1_Stop or not PdS539 , Q1 = PDC404 );(*液压油2号泵启停*)HydOilPump2_RS( Set := HydOilPump2_Start or PE511_L, R1 := HydOilPump2_Stop or not PdS540 , Q1 = PDC405 );(*液压油电加热器启停*)HydOilHeater_RS( Set := HydOilHeater_Start or TI511_L, R1 := HydOilHeater_Stop or not PdS541 or TI511_H or LE511_L, Q1 = PDC406 );(*液压油自过滤泵启停*)HydOilFilter_RS( Set := HydOilFilter_Start, R1 := HydOilFilter_Stop or not PdS542, Q1 = PDC407 );(*盘车电机启停*)TurningMotor_RS( Set := TurningMotor_Start, R1 := TurningMotor_Stop or not PdS554 or (SE801A50) and (SE801B50) or (SE801B50) and (SE801C50) or (SE801A50) and (SE801C50) or PE401_L , Q1 = PDC416 );3 AIAlarm:(*主油泵出油压力报警*)PE401_LevelL( Enable := 1, In := PE402, Hysteresis := 0.01, Level1 := 0.05, InLtLevel1 = PE401_LL, Level2 := 0.12, InLtLevel2 = PE401_L );(*液压油总管出口压力报警*)PE511_LevelLL( Enable := 1, In := PE511, Hysteresis := 0.1, Level1 := 8, InLtLevel1 = PE511_LL );PE511_LevelL( Enable := 1, In := PE511, Hysteresis := 0.1, Level1 := 11, InLtLevel1 = PE511_L );(*静叶开度报警*)VZ512_LevelL( Enable := 1, In := VZ512, Hysteresis := 0.2, Level1 := 0, InLtLevel1 = VZ512_L );(*氮气支管压力低报警*)PI601_LevelL( Enable := 1, In := PI601, Hysteresis := 0.01, Level1 := 0.3, InLtLevel1 = PI601_L, Level2 := 0.2, InLtLevel2 = PI601_LL );PI601_LevelH( Enable := 1, In := PI601, Hysteresis := 0.02, Level1 := 0.32, InGtLevel1 = PI601_H );(*透平超速*)SE801A_LevelH( Enable := 1, In := SE801A, Hysteresis := 5, Level1 := 3150, InGtLevel1 = SE801A_HH, Level2 := 3100, InGtLevel2 = SE801A_H );(*透平超速*)SE801B_LevelH( Enable := 1, In := SE801B, Hysteresis := 5, Level1 := 3150, InGtLevel1 = SE801B_HH, Level2 := 3100, InGtLevel2 = SE801B_H );(*透平超速*)SE801C_LevelH( Enable := 1, In := SE801C, Hysteresis := 5, Level1 := 3150, InGtLevel1 = SE801C_HH, Level2 := 3100, InGtLevel2 = SE801C_H );(*透平前轴振动A报警*)XT801A_LevelH( Enable := 1, In := XT801A, Hysteresis := 1, Level1 := 120, InGtLevel1 = XT801A_HH, Level2 := 80, InGtLevel2 = XT801A_H );(*透平前轴振动B报警*)XT801B_LevelH( Enable := 1, In := XT801B, Hysteresis := 1, Level1 := 120, InGtLevel1 = XT801B_HH, Level2 := 80, InGtLevel2 = XT801B_H);(*透平后轴振动A报警*)XT802A_LevelH( Enable := 1, In := XT802A, Hysteresis := 1, Level1 := 120, InGtLevel1 = XT802A_HH, Level2 := 80, InGtLevel2 = XT802A_H );(*透平后轴振动B报警*)XT802B_LevelH( Enable := 1, In := XT801B, Hysteresis := 1, Level1 := 120, InGtLevel1 = XT802B_HH, Level2 := 80, InGtLevel2 = XT802B_H );(*透平位移A报警*)ZT801A_LevelH( Enable := 1, In := ZT801A, Hysteresis := 0.01, Level1 := 0.5, InGtLevel1 = ZT801A_HH, Level2 := 0.3, InGtLevel2 = ZT801A_H );(*透平位移B报警*)ZT801B_LevelH( Enable := 1, In := ZT801B, Hysteresis := 0.01, Level1 := 0.5, InGtLevel1 = ZT801B_HH, Level2 := 0.3, InGtLevel2 = ZT801B_H );(*透平位移A报警*)ZT801A_LevelL( Enable := 1, In := ZT801A, Hysteresis := 0.01, Level1 := -0.5, InLtLevel1 = ZT801A_LL, Level2 := -0.3, InLtLevel2 = ZT801A_L );(*透平位移B报警*)ZT801B_LevelL( Enable := 1, In := ZT801B, Hysteresis := 0.01, Level1 := -0.5, InLtLevel1 = ZT801B_LL, Level2 := -0.3, InLtLevel2 = ZT801B_L );(*发电机前轴振动A报警*)XT803A_LevelH( Enable := 1, In := XT803A, Hysteresis := 1, Level1 := 120, InGtLevel1 = XT803A_HH, Level2 := 80, InGtLevel2 = XT803A_H );(*发电机前轴振动B报警*)XT803B_LevelH( Enable := 1, In := XT803B, Hysteresis := 1, Level1 := 120, InGtLevel1 = XT803B_HH, Level2 := 80, InGtLevel2 = XT803B_H );(*透平前轴承温度A报警*)PE201A_LevelH( Enable := 1, In := PE201A, Hysteresis := 1, Level1 := 75, InGtLevel1 = PE201A_HH, Level2 := 70, InGtLevel2 = PE201A_H );(*透平前轴承温度B报警*)PE201B_LevelH( Enable := 1, In := PE201B, Hysteresis := 1, Level1 := 75, InGtLevel1 = PE201B_HH, Level2 := 70, InGtLevel2 = PE201B_H );(*透平后轴承温度A报警*)PE202A_LevelH( Enable := 1, In := PE202A, Hysteresis := 1, Level1 := 75, InGtLevel1 = PE202A_HH, Level2 := 70, InGtLevel2 = PE202A_H );(*透平后轴承温度B报警*)PE202B_LevelH( Enable := 1, In := PE202B, Hysteresis := 1, Level1 := 75, InGtLevel1 = PE202B_HH, Level2 := 70, InGtLevel2 = PE202B_H );(*透平前止推轴承温度A报警*)PE203A_LevelH( Enable := 1, In := PE203A, Hysteresis := 1, Level1 := 75, InGtLevel1 = PE203A_HH, Level2 := 70, InGtLevel2 = PE203A_H );(*透平前止推轴承温度B报警*)PE203B_LevelH( Enable := 1, In := PE203B, Hysteresis := 1, Level1 := 75, InGtLevel1 = PE203B_HH, Level2 := 70, InGtLevel2 = PE203B_H );(*透平后止推轴承温度A报警*)PE204A_LevelH( Enable := 1, In := PE204A, Hysteresis := 1, Level1 := 75, InGtLevel1 = PE204A_HH, Level2 := 70, InGtLevel2 = PE204A_H );(*透平后止推轴承温度B报警*)PE204B_LevelH( Enable := 1, In := PE204B, Hysteresis := 1, Level1 := 75, InGtLevel1 = PE204B_HH, Level2 := 70, InGtLevel2 = PE204B_H );(*快切阀门油压低*)PE512_LevelL( Enable := 1, In := PE512, Hysteresis := 0.2, Level1 := 2, InLtLevel1 = PE512_L );(*润滑油箱温度高*)TIA401_LevelH( Enable := 1, In := TIA401, Level1 := 40, InGtLevel1 = TIA401_H );TIA401_LevelL( Enable := 1, In := TIA401, Level1 := 15, InLtLevel1 = TIA401_L );(*润滑油箱液位低*)LE401_LevelL( Enable := 1, In := LE401, Level1 := 200, InLtLevel1 = LE401_L );(*液压油箱温度高*)TI511_LevelH( Enable := 1, In := TI511, Level1 := 40, InGtLevel1 = TI511_H );TI511_LevelL( Enable := 1, In := TI511, Level1 := 20, InLtLevel1 = TI511_L );(*液压油箱液位低*)LE511_LevelL( Enable := 1, In := LE511, Level1 := 15, InLtLevel1 = LE511_L );(*高炉顶压*)DingYaCL1_LevelH( Enable := 1, In := DingYaCL1, Hysteresis := 1, Level1 := 180, InGtLevel1 = DingYaCL1_H, Level2 := 220, InGtLevel2 = DingYaCL1_HH );DingYaCL2_LevelH( Enable := 1, In := DingYaCL2, Hysteresis := 1, Level1 := 180, InGtLevel1 = DingYaCL2_H, Level2 := 220, InGtLevel2 = DingYaCL2_HH ); (*透平入口煤气*)PE102_LevelH( Enable := 1, In := PE102, Hysteresis := 1, Level1 := 120, InGtLevel1 = PE102_H, Level2 := 200, InGtLevel2 = PE102_HH );(*发电机定子温度*)TISA205_1LevelH( Enable := 1, In := TISA205_1, Hysteresis := 1, Level1 := 130, InGtLevel1 = TISA205_1HH, Level2 := (80+TISA208A), InGtLevel2 = TISA205_1H );TISA205_2LevelH( Enable := 1, In := TISA205_2, Hysteresis := 1, Level1 := 130, InGtLevel1 = TISA205_2HH, Level2 := (80+TISA208A), InGtLevel2 = TISA205_2H );TISA205_3LevelH( Enable := 1, In := TISA205_3, Hysteresis := 1, Level1 := 130, InGtLevel1 = TISA205_3HH, Level2 := (80+TISA208A), InGtLevel2 = TISA205_3H );TISA205_4LevelH( Enable := 1, In := TISA205_4, Hysteresis := 1, Level1 := 130, InGtLevel1 = TISA205_4HH, Level2 := (80+TISA208A), InGtLevel2 = TISA205_4H );TISA205_5LevelH( Enable := 1, In := TISA205_5, Hysteresis := 1, Level1 := 130, InGtLevel1 = TISA205_5HH, Level2 := (80+TISA208A), InGtLevel2 = TISA205_5H );TISA205_6LevelH( Enable := 1, In := TISA205_6, Hysteresis := 1, Level1 := 130, InGtLevel1 = TISA205_6HH, Level2 := (80+TISA208A), InGtLevel2 = TISA205_6H );TISA205_7LevelH( Enable := 1, In := TISA205_7, Hysteresis := 1, Level1 := 130, InGtLevel1 = TISA205_7HH, Level2 := (80+TISA208A), InGtLevel2 = TISA205_7H );TISA205_8LevelH( Enable := 1, In := TISA205_8, Hysteresis := 1, Level1 := 130, InGtLevel1 = TISA205_8HH, Level2 := (80+TISA208
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 安全培训教师岗位证书课件
- 2025年榆林华源电力有限责任公司招聘(5人)模拟试卷及完整答案详解1套
- 2025春季中国电信实习生招聘模拟试卷含答案详解
- 2025年安徽皖信人力资源管理铜陵分公司招聘20人模拟试卷含答案详解
- 2025内蒙古鄂尔多斯市康巴什区青年就业见习计划招募模拟试卷及答案详解(名师系列)
- 2025国家农业农村部食物与营养发展研究所综合办公室助理招聘4人模拟试卷及答案详解(必刷)
- 小学劳动安全培训制度课件
- 2025河北邯郸冀南新区选聘农村党务(村务)工作者111人考前自测高频考点模拟试题及完整答案详解
- 2025年PCB制板项目合作计划书
- 2025年上海市金融稳定发展研究中心公开招聘工作人员考前自测高频考点模拟试题及1套完整答案详解
- 餐饮财务问题的研究报告
- 慢性疾病运动干预中心服务要求(征求意见稿)
- 人教版数学-五年级上册-第一单元计算、解决问题(同步练习)
- 林同炎与美洲银行大厦
- (正式版)SH∕T 3548-2024 石油化工涂料防腐蚀工程施工及验收规范
- 人教版八年级历史上册 第一、二单元 单元测试卷( 2024年秋)
- 二次抵押贷款合同
- DZ/T 0462.5-2023 矿产资源“三率”指标要求 第5部分:金、银、铌、钽、锂、锆、锶、稀土、锗(正式版)
- 糖尿病合并尿路感染
- 芯片封装行业分析
- 健康指南绝经与乳腺癌的关联性
评论
0/150
提交评论