




免费预览已结束,剩余3页可下载查看
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
responsible for the development of company management, including the development of settlement and settlement standards of preparation, the business unit clearing work inspection and guidance, business settlement audit; 23, is in charge of the company business and costs calculation and analysis of new projects and to develop standards and provide the basis for decision-making and responsible for the comprehensive economic and technical indicators and statistics, analysis, summary and reporting; 24, the company responsible for audits of various types of business contracts, the principal of contract price (purchase price, freight, taxes, etc), payment method, payment, settlement, such as the reasonableness of the data, authenticity, accuracy; 25, strict enforcement of national tax policy, is responsible for the monthly reporting, including tax calculations, statistics, go through the relevant formalities, receive invoices; 26, the company responsible for all kinds of price (including product price, material prices,Freight, engineering machinery jobs price, price, price) s terms of market surveys, quotations, price exception report; 27, is responsible for the companys management, including conference organized by price, of historical prices, totals, etc; 28, according to the annual operating plan, annual costs and undergo decomposition, control, analysis and evaluation; responsible for costing and cost control, ensure accounting number is reasonable, correct, and complete accounting report and the companys other reports compiled and reported to work;变电站电气安装工程盘、柜、屏安装施工方案编写:审核:批准:2012年6月15日1 引用标准 GB50171-92 电气装置安装工程盘、 柜及二次回路结线施工及验收规范 DL50168-92 电气装置安装工程电缆线路施工及验收规范DL5009.3-1997 电力建设安全工作规程 (变电所部分)GB50172-92 电气装置安装工程蓄电池施工及验收规范 (83)水电基火字第137号火电施工质量检验及评定标准第五篇电气装置(试行)2 施工准备2.1 技术准备2.1.1 现场负责工程师(技术员)负责作好技术交底工作。2.1.2 施工负责人与现场负责工程师(技术员)在施工开始前,要认真做好以下工作: a) 施工前对所有的图纸要进行校核,修改过的部分必须经设计院认可方可进行施工;b) 按校核过的图纸对电缆清册进行校对。2.1.3 施工人员在施工前要认真学习本工艺标准,并在施工中贯彻执行:2.1.4 直流蓄电池安装调试前,应具备以下条件:a) 制造厂家技术说明书和其他技术文件齐全;b) 直流屏、硅整流屏及电力电缆安装调试完毕;c) 联系交流电源供电,应保证在充、放电期间连续供电。必要时应有备用电源,以防止充、放电过程中突然断电。2.2 人员组织 施工负责人: 1名 技术负责人: 1名(或协助负责人1-2名)安 质 员: 1名二次回路试验人员: 2-3名 安装人员: 3-5名2.3 施工工器具: 液压吊车 8T 1辆 撬 杠 L=1.5m 2根 校 线 灯 自制 4对 绝缘摇表 1000V 1台 皮 尺 50米 1把 钢 管 32 L=3米 2根 L=1.5米 4根 磁 座 钻 1台 电 焊 机 1台水 平 尺 1把 钢 卷 尺 5m 准确度0.2mm 1 只钢 板 尺 1m 准确度0.1mm 2 只冲 击 钻 116mm 附钻头12 1 套2.4 对土建工程要求 2.4.1 与盘、 柜装置及二次回路电缆施工,二次回路结线安装有关的建筑物,构筑物的建筑工程质量,应符合国家现行的建筑工程施工及验收规范中的有关规定,当设备或设计有特殊要求时,尚应满足其要求。2.4.2 屏、柜、箱安装前建筑工程应具备下列条件: a) 屋顶、楼板施工完毕,不得渗漏; b) 结束室内地面工作,室内沟道无积水、杂物; c) 预埋件及预留孔符合设计要求,预埋件应牢固; d) 门窗安装完毕; e) 进行装饰工作时有可能损坏已安装设备或设备安装后不能再进行施工的装饰工作全部结束;f) 基础型钢的预埋应符合表中规定:基础型钢安装的允许偏差项 目 允 许 偏 差mm/mmm/全长不 直 度 1 5水 平 度 1 5位置误差及不平行度 5注:环形布置按设计要求g)基础型钢安装后,其顶部宜高出抹平地面10mm;手车式成套柜按产品技术要求执行。基础型钢应有明显的可靠接地。2.4.3 二次线施工前建筑工程应具备下列条件:a) 预埋件符合设计、安置牢固; b) 电缆沟、隧道、竖井及人孔等处的地坪及抹面工作结束; c) 电缆层、电缆沟、隧道等处的施工临时设施、模板及建筑废料等清理干净,电缆室的门窗安装完毕。2.4.4 如发现影响电气安装的土建工程缺陷,即向现场负责工程师(技术员)反映,以便迅速与有关部门研究处理方案。2.5 设备检查及保管2.5.1 盘、柜应存放在室内或能避雨、雪、风、沙的干燥场所,对有特殊保管要求的装置性设备和电气元件,应按规定保管。2.5.2 盘柜等在搬运和安装时应采取防震、防潮、防止柜架变形和漆面受损等安全措施。2.5.3 盘柜到达现场后,在没有合适的存放条件时,应及时在规定的期限内验收检查,并应符合下列要求: a) 包装及密封良好; b) 开箱检查型号、规格符合设计要求,设备无损伤,附件、备件齐全; c) 产品的技术文件齐全;d) 外观检查合格;e) 按审核过的图纸对盘、屏、柜、箱进行回路查线,如有和图纸不符者,必须按图改正。2.5.4二次电缆在运输过程中,不应使电缆及电缆盘受到损伤。严禁将电缆直接由车上推下。电缆盘不应平放运输,平放贮存。2.5.5 运输或滚动电缆盘前,必须保证电缆盘牢固,电缆绕紧。2.5.6 电缆到达现场后,应按下列要求及时进行检查:a) 产品的技术文件齐全;b) 电缆型号、规格、长度应符合订货要求,电缆外观不应受损;c) 当外观检查有怀疑时,应及时进行绝缘试验。2.5.7 电缆到达现场后,应按下列要求贮存: a) 电缆应集中分类存放,应标明型号、电压、规格、长度。电缆盘之间应有通道。地基应坚实,当受条件限制时,盘下应加垫,存放处不得积水;b) 防火涂料、包带、堵料等防火材料,应根据材料性能和保管要求贮存和保管;c) 电缆支架应分类保管,不得因受力变形。2.5.8 蓄电池到达现场后,应在产品规定的有效保管期限内进行安装及充电。不立即安装时,其保管应符合下列要求: a) 酸性和碱性蓄电池不得存放在同一室内; b) 蓄电池不得倒置,开箱存放时,不得重叠; c) 蓄电池应存放在清洁、干燥、通风良好、无阳光直射的室内。存放中,严禁短路、受潮,并应定期清除灰尘,保持清洁; d) 蓄电池的保管室温宜为540。存放宜在放电状态下,拧上密气塞,清理干净,在极柱上涂抹防腐脂。2.5.9 蓄电池安装前,应按下列要求进行开箱外观检查: a) 蓄电池的型号、规格符合设计要求; b) 厂家技术说明书及其他技术文件齐全;c) 蓄电池外壳应无裂纹、损伤、漏液等现象; d) 蓄电池的正、负端柱必须极性正确,壳内部件应齐全无损伤,有孔气塞通气性能应良好; e) 极板无严重受潮和变形,槽内部件应齐全无损伤;f) 连接条、螺栓及螺母应齐全,无锈蚀;g) 带电解液的蓄电池,其液面高度应在两液面线之间;防漏运输螺塞应无松动、脱落。2.5.10蓄电池盘柜开箱检查时,应通知建设单位、监理单位,同时应仔细清点,及时填写开箱记录,各单位代表签字认可。2.5.11 发现异常由现场负责工程师(技术员)书面报告公司物资供应站,并与监理、甲方代表联系处理方案。3 施工工艺3.1 盘、柜、箱的就位及安装4.1.1 在基础型钢上依据施工标示出出每面盘、柜、箱的具体位置,然后按照实际盘、柜、箱的固定螺栓孔距在基础型钢上画出孔的实际位置。3.1.2 地脚螺栓的处理,有以下两种方法可供选择。 a) 将螺栓的六角头去掉,用电焊机将螺杆焊在基础型钢的孔位上。待盘、柜就位后,用螺母将其与基础型钢固定;b) 用磁座钻在基础型钢的孔位上钻孔、滚丝,等盘、柜就位后,用螺栓将其与基础型钢连接固定。3.1.3 高层室内的盘、柜等开箱检查后,采用吊车吊到空中平台上,然后用钢管作滚杠,垫在盘、柜的底部移动至安装位置,然后撤掉滚杠,就位固定。也可用小型液压插车两台将盘移动至安装位置后,将插车推出就位。3.1.4 盘、柜就位后,应重新核对安装位置的正确性。3.1.5 盘、柜间的连接,要求每边上、中、下部各采用1只螺栓连接。3.1.6 全列 (或单独)盘柜按上述方法连接和固定后,用线坠和白线绳测量盘柜的水平偏差和垂直度。然后用撬杠调整,使水平偏差、垂直度,整列盘、柜面偏差符合规范要求。同时,模拟母线应对齐,其误差不应超过视差范围,并应完整,安装牢固。3.1.7 控制、保护盘柜内的电器装置安装调试应按照厂家技术资料要求进行。3.1.8 蓄电池组的安装应符合下列要求:3.1.8.1 蓄电池放置的平台、基架及间距应符合设计要求。3.1.8.2 蓄电池安装应平稳,同列电池应高低一致,排列整齐。3.2.8.3 连接条及抽头的接线应正确,接头连接部分涂以电力复合脂,螺母应紧固。3.1.8.4 有抗震要求时,其抗震设施应符合有关规定并牢固可靠。3.1.8.5 镉镍蓄电池直流系统成套装置应符合国家现行技术标准的规定。4 质量标准(包括对质量通病的措施)4.1 盘、柜、箱的就位及安装。4.1.1 配电盘、柜、箱安装后应垂直,屏间应紧密无隙,连接螺栓不得缺少和松动,屏面不应相互参差不齐,其偏差应符合下表:盘、柜、屏安装的允许偏差表项 目允许偏差()垂直度(每米)1.5水平偏差相邻两盘顶部2成列盘顶部5盘面偏差相邻两盘边1成列盘面5盘 间 接 缝24.1.2 盘、 柜、箱应用螺栓牢固可靠的固定在基础上,不准采用焊接方法固定。4.1.3 端子箱安装应牢固,封闭良好,安装位置应便于检查。4.1.4 配电盘、柜、箱的接地应可靠良好。对装有电器的可开启的盘、柜、箱门应以多股软导线与主接地网可靠连接。4.1.5 对于安装在同一地点的盘、柜、箱其表面颜色应和谐一致。模拟母线颜色应符合表中的规定。模拟母线的标志颜色电压(KV)颜色电压(KV)颜色电压(KV)颜色交流0.23深灰交流13.8-20浅绿交流 220紫交流0.40黄褐交流 35浅黄交流 330白交流 3深绿交流 60橙黄交流 500淡黄交流 6深蓝交流 110朱红直 流褐交流 10绛红交流 154天蓝直流500深紫5 安全措施5.1 控保屏在拆箱时,应将箱板等杂物清理干净,以免阻碍通道或钉子扎脚。5.2 移动屏盘时,应有足够的人力,统一指挥,防止倾倒伤人,狭窄处要防止挤手。5.3 屏盘底座加垫时,不可将手伸入盘底,多面屏并列时要防止挤手。5.4 对重心偏移在一侧的屏盘,在未安装好以前,应有防止倾倒的措施。5.5 各种屏盘内安装各式开关、熔断器,凡直立者应一律上口是电源,下口是负荷。5.6 在扩建变电所工作时,要和变电所签订安全合同。5.7 凡有关带电屏的接线,应由变电所 (或甲方)派人进行接线,并有人监督。5.8 带电系统与非带电系统必须有可靠的隔离措施。5.9 保护及试验人员在工作时,要通知有关二次安装人员,以免窜电伤人。5.10 在部分带电屏上工作时,必须遵守以下规定:a) 应了解盘屏内带电系统的情况;b) 穿工作服,穿绝缘鞋,带绝缘帽子,严禁穿背心、短裤工作; c) 使用的工具
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年湖南师范大学附属小学第二轮非事业编制教师招聘模拟试卷含答案详解
- 2025年山西焦煤集团所属煤炭子公司井下操作技能人员招聘模拟试卷及参考答案详解1套
- 2025年福建省泉州市晋江市首峰中学招聘1人模拟试卷及一套参考答案详解
- 妇幼保健院医生爱岗敬业演讲稿3篇
- 2025年高一上学期语文第一次月考试卷含答案
- 2025年烟台市卫生健康委员会所属事业单位卫生类岗位公开招聘工作人员(385人)考前自测高频考点模拟试题附答案详解
- 2025年社区康复医疗服务体系建设与运营实践报告
- 2025年甘肃省陇南事业单位招聘在哪查看考前自测高频考点模拟试题及一套答案详解
- 2025年城东区面向社会公开招聘公共服务岗位聘用人员模拟试卷附答案详解(完整版)
- 市场租赁协议书范本5篇
- 零星维修工程施工组织设计方案方案
- 2025年汽车驾驶员(技师)考试试题及答案(含答案)
- 2025大连国际机场招聘25人笔试历年参考题库附带答案详解
- 2025年浙江铁塔招聘笔试备考题库(带答案详解)
- 2025年上海市(秋季)高考语文真题详解
- 《秘书文档管理第三版》课件第七章
- 电力工程电缆设计课件
- 施工班组驻地管理制度
- 城投公司成本控制管理制度
- 中国磷化工行业市场规模及发展前景研究报告(智研咨询)
- 万亨工业科技(台州)股份有限公司年产500万套逆变器及配件、800万套新能源汽车控制器配件技改项目环评报告
评论
0/150
提交评论