1 Channel RS485 Relay Manual 2CH RS485 Relay Serial HyperTerminal Enter(Usage 2-channel and 1-channel is the same):/v_show/id_XMTM0ODY4NzkxMg=.html 2CH RS485 Relay Modbus Poll Enter(Usage 2-channel and 1-channel is the same):/v_show/id_XMTM0ODY4OTg5Mg=.htmlFeatures:1: DC 12V power supply (voltage range 9-13V )2: Standby current (all relays closed) 11-13MA, relay open 43MA3: open close Momentary Self-locking Interlock Delay 6 Commands4: Two instruction-control mode : AT command and MODBUS command5: Under the AT command ,the maximum delay is 9999 seconds Under the MODBUS command ,the maximum delay is 255 seconds6 AT commands can be made serial HyperTerminal (serial assistant) Enter; MODBUS commands can be made serial HyperTerminal (serial assistant) OR Modbus Poll Enter;7 Under the MODBUS command mode, it can support up to 32 devices in parallel8 Size: 45 * 30 * 18mm9 Weight: 18.5g10 Maximum load: 20A 14VDC;20A/125VAC;10A/250VACGlossary:NO : Relay normally open contactCOM : Relay common contactNC : Relay normally closed contactOpen : NO connection COM, NC disconnect COMClose : NO disconnect COM, NC connection COMMomentary : Enter the Momentary command, the Rreceiver Relay is Open, delay of 0.5 seconds after, Relay is Close;Toggle : Enter the Toggle command, the Rreceiver Relay is Open, Enter the Toggle command again, Relay is Close;Latched : Enter the Channel 1 Latched command, the receiver Channel 1 is Open, the Channel 2 is Close.Enter the Channel 2 Latched command the receiver Channel 2 is Open, the Channel 1 is Close.Enter the Channel 3 Latched command the receiver Channel 1 is Close, the Channel 2 is Close.Delay : Enter the Delay command, the Rreceiver Relay is Open, delay of 0-9999 seconds(MODBUS command is 0-255 seconds )after, Relay is Close;During the delay, Eter the Close command, immediately close the relayCommand mode selection :( figure above) M0 disconnect is MODBUS command mode. M0 Connect is AT command mode.Slave ID: Different Sliver ID can be set by command, the maximum number is 247Under the MODBUS command mode,the slave ID must be correctcommand Description, Please refer to 1 Channel RS485 Relay CommandTypical applications: 1 AT command mode (M0 Connect), in this mode can be through the serial HyperTerminal (serial assistant) enter a simple AT command control relay. AT command mode time up to 9999 seconds 2 MODBUS command mode (M0 disconnect), you can control a variety of ways: Serial Hyper Terminal Control (need to manually add the CRC), Modbus Poll software control (software automatically add the CRC), PLC or MCU process controlWiring Diagram:1 DC 12V control circuit,Wiring diagram below. LOAD may be camera,LED lights, fans, motors and other DC 12V equipment2 DC 1-100VAC 85-265V control circuit,Wiring diagram below(Note:If not DC 12V lo

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论