




全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
精选文库The roads to CE marking of medical devicesFor manufacturers of devices covered by the Medical Device Directive 93/42/EECGeneral requirementsAll manufacturers of medical devices must:(custom-made devices and devices intended for clinical investigation are excluded)classify the devices (Annex IX)based upon the class the device belongs to, select (Article 11) and follow the appropriate conformity assessment procedure (Annexes II - VII). (See summaries for each class below.) The harmonised standard to fulfil the requirements of the quality systems in Annexes II, V and VI is EN ISO 13485:2003 “Medical Devices Quality systems Requirements for regulatory purposes” where applicable.ensure that the devices fulfil the Essential Requirements (Annex I) prepare technical documentation (Annex II, III or VII) which shall include a general description of the product, design drawings, the results of the risk analysis, a list of standards applied, test reports etc. The documentation shall make it possible to assess the conformity of the product with the requirements of the Directiveestablish a system for reviewing data about products placed on the market and implement appropriate means to apply any necessary corrective actionsnotify the authorities of serious accidents and narrow escapes caused by the productissue an EC Declaration of Conformityfile the EC Declaration of Conformity, the technical documentation, as well as decisions, reports and certificates from Notified Bodies to make them available to the national authorities (shall be filed for a period ending at least five years after the last product has been manufactured)All products mustcomply with the Essential Requirementsbe provided with CE marking, except for custom made devices and devices intended for clinical investigationsClass I productsThe manufacturer himself declares that the products meet the provisions of the Directive which apply to them, prepares a technical documentation and affix the CE mark to the device (Annex VII).The manufacturer or his authorized representative for marketing of the product shall register his activities at the competent authority of the member state where his registered business is located.Exception:The device is placed on the market in a sterile condition and/or has a measuring function. The Notified Body shall examine the production process with regard to sterility and/or measuring function (Annexes IV, V or VI).Class IDevice Article 11:5 Annex VIIDeclaration of conformity Sterile or measuring YES NO *Annex IV, V or VIVerification of Notified BodyCECE*) Limited useClass IIa productsAlternative 1:The Notified Body shall accept the manufacturers total quality system (design, manufacturing and final inspection) according to Annex II, except for Section 4.Alternative 2:The manufacturer himself declares that the products meet the provisions of the Directive which apply to them according to Annex VII. In addition the Notified Body examines and accepts each manufactured item/batch according to Annex IV or accepts the quality system for production and final testing according to Annex V or the quality system for products according to Annex VI.After having taken various administrative measures described in the relevant Annex, the manufacturer then affix the CE mark and the identification number of the Notified Body to the product.Class IIaDevice Article 11:2Either OrAnnex IIA system with full quality assuranceAnnex VIIDeclaration of conformity With Annex VA system with production quality assuranceAnnex VIA system with product quality assuranceAnnex IVEC verification-Evalutation and testing of every device or statistical verification Either Or Or Not including exam of the design (Article II, clause 3a) CECECECEClass IIb productsAlternative 1:The Notified Body shall accept the manufacturers total quality system (design, manufacturing and final inspection) according to Annex II, except for Section 4.Alternative 2:The Notified Body shall examine and assess the documentation and type-test the product according to Annex III and examine and accept each manufactured item/batch according to Annex IV or accept the quality system for production and final testing according to Annex V or the quality system for products according to Annex VI.After having taken various administrative measures described in the relevant Annex, the manufacturer then affix the CE mark and the identification number of the Notified Body to the product.Class IIbDevice Article 11:3Either OrAnnex IIA system with full quality assurance systemAnnex IIIType examination With Annex VIA system with product quality assuranceAnnex VA system with production quality assuranceAnnex IVEC verification-Evalutation and testing of every device or statistical verification Either Or Or Not including exam of the design (Article II, clause 3a) CECECECEClass III productsAlternative 1:The Notified Body shall accept the manufacturers total quality system (design, manufacturing and final inspection) and examine the design of the product according to Annex II.Alternative 2:The Notified Body shall examine and assess the documentation and type-test the product according to Annex III and examine and accept each manufactured item/batch according to Annex IV or accept the quality system for production and final testing according to Annex V.After having taken various administrative measures described in the relevant Annex, the manufacturer then affix the CE mark and the identification number of the Notified Body to the product.Class
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 去年的期末数学试卷
- 医药中间体生产项目施工方案
- 化妆品导购基础知识培训
- 历届日照市中考数学试卷
- 柳州四年级统考数学试卷
- 司机培训课件封面设计
- 去年深圳中考数学试卷
- 2025年小学试题试卷片及答案
- 七下第九单元数学试卷
- 建筑工程主体结构施工方案
- 2025年贵州航空产业城集团股份有限公司招聘笔试参考题库含答案解析
- 抗凝药物使用注意事项
- DZ 0141-1994地质勘查坑探规程
- 电玩城现场管理制度
- T/CECS 10386-2024排水工程微型顶管用高性能硬聚氯乙烯管及连接件
- DB32/T 3956-2020化工企业安全风险分区分级规则
- DB31/ 970-2016建筑用人造石单位产品能源消耗限额
- 台风安全培训课件
- 1999-2025年南开生物化学考研真题
- 2025年工程管理知识试题及答案
- 月子会所考试试题及答案
评论
0/150
提交评论