




已阅读5页,还剩11页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
NAME,FloTHERMApplicationExamples,TITLEMechanicalAnalysisDivision,10June,2020,FluidFlowSimulationHelpsOvercomeToughTelecomThermalDesignChallenge,ElmaElectronicusedFloTHERMtooptimizethedesignofanewAdvancedTelecommunicationsComputingArchitecture(ATCA)platformthatisdesignedtodissipateupto300wattsineachofits14slots.ElmathermalengineersusedFloTHERMscapabilitytoautomaticallyrunaseriesofflowsimulationswhilevaryingvariousdimensionsandotherparameterstoachievedesigngoalssuchasmaximizingairflowovertheboards.,“AtElmawearestrongbelieversinthermalsimulationanduseitfrequentlytodesignthespacingforairintakeandexhaust,typesoffansandblowers,theplenumspaceaboveorbelowthefans,theplacementofairfiltersandtheuseofbafflestooptimizechassisthermalmanagement.WeevaluatedbothoftheleadingthermalsimulationsoftwarepackagesandusetheMentorGraphicsMechanicalAnalysisDivisionsFloTHERMbecauseitismoreuserfriendly,providessuperiorreportingtools,andourcustomershavegreaterconfidenceinitsaccuracy.”RamRajan,ThermalEngineer,ElmaElectronic,RedbackNetworksCreateFirstMillion-SubscriberPlatform,Redbacksperformedaconsiderablenumberofsimulationstoevaluatedifferentfailuremodes.Thesimulationresultsrevealedthatafanfailurecausedairflowrecirculation,whichreducedsystemairflowandoverheatedtheaffectedregion.Theyaddedalouverassemblytoeachfan,whichautomaticallyclosethefanopeningincaseoffanfailure.Thiseffectivelyeliminatedrecirculation.Afoamcoremodelofthenewplenumwascommissionedsothatphysicaltestscouldbeperformedquickly.Thelabmeasurementscloselymatchedthesimulationresultssonothermaldesignchangeswererequiredduringtheprototypephase.Thenewplatformisjustgoingintoproductionbutithasalreadybeenselectedbyoneofthetop20telephonecarriersintheworld,ChungHwaTelecom(CHT)ofTaiwan.,“Thepowerdissipationofthelinecardsinthenewplatformhadtobeincreasedby2Xrelativetothepreviousgenerationtoobtaintheplannedimprovementinperformanceandfunctionality,”saidWendyLu,MechanicalEngineerforRedbackNetworks.“Byfocusingonreducingthechassisstaticpressureviageometrychangesandusingahigherperformingfan,wewereabletodoubletheairflowinthechassis.”WendyLu,MechanicalEngineer,RedbackNetworks,SimclarDesignNewTelecomPlatformthatDelivers40GbpsBandwidth,WesucceededindevelopingaplatformthatgoeswellbeyondtheATCA3.0specificationbydelivering40Gbpsbackplanebandwidthand50CFMairflowperslotwithnear-perfectairflowdistribution.Thermalsimulationwasacriticalprocessinourproductdevelopment.ThermalsimulationislikehavingX-rayvision.Itletsyouseeinsidetheboxtolookatairflow,pressuresandtemperaturesatanypoint.Asinglethermalsimulationgivesyouadetailedunderstandingofwhatisgoingoninsidetheboxandhelpsyouquicklyidentifytherootcausesoftheproblem.”DaveWatson,ThermalDesignTeamLeader,SimclarGroup,ThermalSimulationReducesCostofStackedModulePottingCompoundby50%,C-MAC,anelectronicsdesignandmanufacturingcompanybasedinSouthDenes,GreatYarmouth,UnitedKingdom,recentlydevelopedastackedmoduleforacriticaldefenceapplication.Priortobuildingprototypes,C-MACengineersperformedthermalsimulationontheinitialconceptdesignanddiscoveredthatjunctiontemperaturesonthemodulerangedupto125C,wellabovethe100Cmaximum.Theyrealizedtheyneededapottingcompoundtoreducethermalresistanceandwantedtoselecttheleastexpensiveformulationthatwouldmeetthethermalrequirementsoftheapplication.,Withoutsimulationwewouldhavebeenfacedwithtwounattractivealternatives.Wecouldhaveundertakenamuchlengthierandmoreexpensivephysicaltestingprocesstoidentifythepottingcompoundthatprovidedthebestmixofperformanceandprice.”JonathanCrossley,SeniorEngineer,C-Mac,FloTHERMandFloEFDOptimizesThermalSolutionforCaltech,DesignChallengeDesignathermalsolutionthatmaintainedcomponenttemperaturesbelow85Cwithminimaltemperaturespreadacrossthehottestcomponents.SolutionandBenefitOurengineerswereabletorealizeanaveragereductioninjunctiontemperaturesof35Crelativetothebaselinecase,andwereabletoreducethetemperaturespreadofthefourFPGAsfrom17Cto9C.,“MentorGraphics-MechanicalAnalysisDivisionsconsultingservicewascommittedtodeliveringacoolingsolutionthatmetmythermalandmechanicalconstraintsonatimescalethemettheneedsoftheproject.DavidHawkins,CaltechOVROObservatory,Hewlett-PackardKeepsProcessorsCoolwithFloTHERM,DesignChallengeDissipatingheatfromhighpowercomponentssuchastheCPU.CPUsplacedback-to-backsofrontprocessorpreheatstheairbeforeitreachesthebackprocessor.SolutionandBenefitFloTHERM“slopingblock”smartfeaturewasusedtorepresenttheinclinedbaffleandtheparametricoptimizationtoolwasusedtodesignandoptimizetheheatsink.FloTHERMsubstantiallyreduceddesigntimeandcostandhelpedtomeettheweighttargetsoftheheatsinks.,“WeuseFloTHERMasourCFDanalysistoolbecauseFloTHERMiswell-structuredandeasytousecomparedtootherCFDtools,andprovidesthebesttechnicalsupport.Thesupportteamisveryknowledgeableandresponsesarealwayswellcoordinated.”ShaileshJoshi,ThermalAnalyst,Hewlett-PackardCompany,ThermalSimulationSpeedsDesignofVersatileVertical/HorizontalHeatsink,CraneAerospace&ElectronicsusedFloTHERMthermalsimulationsoftwaretodevelopanunusualheatsinkthatworksintheverticalorhorizontalorientation.,“Thermalsimulationallowedustooptimizetheheatsinkthermalperformanceandweightinaveryshorttimeperiod.Thermalsimulationalsoenabledustooptimizethedesigntoimproveitsperformancetoalevelthatwouldhavebeenimpossibletoachievewiththebuildandtestmethodwithinourscheduleconstraints.”MarkResler,MechanicalEngineer,CraneAerospace,ThermalSimulationValidatesMotorDesignandReducesHeatsinkWeight,AnJenSolutionsrecentlyusedFloTHERMtoassistMagneMotion,Iheirdesignofaverticalliftelevatormadeoflinearsynchronousmotors(LSM).AnJenSolutionsperformedaweightversusthermalperformanceanalysisoftheLSMrailheatsink.,“FloTHERMoffersawiderangeoffeaturessuchasanautomaticoptimizerandcompactmodelsthatmakeitpossibletoimprovecoolingperformanceandreduceengineeringtime,”Rigbysaid.“TheseandothercapabilitiesofthesoftwaremadeitpossibletooptimizethedesignoftheheatsinkwhichwasimportantbecausetheoverallweightoftheLSMwasacriticalconcerntoMagneMotionscustomer.”MichaelRigby,AnJenSolutions,AMCCUsesFloTHERMandFloTHERMPacktoReduceICPackageDevelopmentCost,AppliedMicroCircuitsCorporation(NASDAQ:AMCC)isusingFloTHERMthermalsimulationsoftwaretosignificantlyreducethecostofpackagingandtheprojectresourcecostforanewfamilyofICs.AMCCachievedtheseoutstandingresultsbycomparingflip-chipandwirebondthermalperformanceearlyinthedesignprocess.,“TheabilitytogeneratethermalmodelsofICsinlessthananhourremovedthebarriersofsimulationcomplexityandtime/resourceconstraintsattheearlystageofourdesignprocess.WeuseFloTHERMforthermalsimulationbecauseitmakesiteasyandconvenienttomodeldifferentpackagestylesandtypes.”MarkPatterson,PackagingEngineer,AMCC,SimulationHelpsSolveDifficultThermalChallengeinTowerMountedAmplifier,ThermacoreusedFloTHERMthermalsimulationsoftwaretosolveachallengingthermalmanagementprobleminatowermountedamplifier(TMA)foracellularbasestation.,“Whenwefirstdecidedtousethermalsimulationwepolledourcustomersandaskedthemwhichsoftwarepackagetheywouldliketohaveususe,theysaidthattheypreferredFloTHERMovertheotherleadingthermalsimulationpackages.TheyuseFloTHERMthemselvessotheyhaveconfidenceinitspredictionsandcaneasilyincorporateourmodelsintotheirfullsystemmodels.SincewebeganusingFloTHERMwehavebeenveryimpressedwithitsabilitytoaccuratelysimulatethermalmanagementchallenges.Onaverage,oursimulationresultspredictreal-worldmeasurementswithin5%.”MattConnors,ApplicationsEngineeringSupervisor,Thermacore,ThermalSimulationHelpsOvercomeChallengesof14Uchassiswith1700Watts,AmphenolTotalConnectionSolutions(TCS)usedFloTHERMsoftwaretoovercomethethermalmanagementchallengesofa14rackunit(U)chassisdissipating1700watts.,“FloTHERMgoesonemajorstepfurtherthanourinternalcodebymodelingtheentiregeometryofthechassis,”Heardsaid.“Icanspecifywherethepowerisdissipatedandthesimulationtrackstheflowofairandtransferofheatthroughoutthechassis.WehaveusedFloTHERMfor16yearsandhavedevelopedahighdegreeofconfidenceinitsaccuracy.Mostofourlargercustomersalsousethesoftwaresowecaneasilyexchangemodelswiththem.”ChrisHeard,Engineer,Amphenol,AlcatelSolvesThermalIssuesEarlywithFloTHERM,Withpowerconsumptionrunningatlevelsofupto2000Wpershelfandupto140Wforeachplug-incard,thermalmanagementpresentedamajordesignchallenge.TheuseofhighspeedopticaltransceiversandASICswithrestrictedtemperaturerangesincreasedthedifficultyofthedesignchallenge.,“Webelievethatitscriticaltoperformacarefulthermalanalysisatthebeginningofeverynewdesign.WehavesuccessfullyusedFlothermsoftwareasourthermalsimulationtoolformanyyears.ThecombinationofFlothermandFlopackenableustoquicklyexploredesignvariationsandfindtheoptimumsolutionatboththesystemandPCBlevels.”PavelValenta,HardwareEngineering,Alcatel,FloTHERMHelpsTecnobitEnsureReliabilityofAvionicsEquipment,Thepowerandheatdissipationofmodernavionicsequipmentisincreasingrapidly,anddesigningappropriatecoolingsystemsisnowanabsolutenecessitytoensurereliability.,“FloTHERMisofcrucialimportancetousinunderstandingandoptimizingthedifferentheattransferpathsandmechanismsbetweenelectroniccomponentsandtheambientsurroundingsintheharshenvironmentalconditionsfoundinaircrafts.ThewayFloTHERMrepresentselectroniccomponentsisakeyadvantage,enablinguseithertousesimplethermaldatafromcomponentdatasheetsorswitchtodetailed3Dmodelsforcriticalcomponentswhennecessary.”Jor
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 无锡广电面试题目及答案
- 少年中国说课件教学
- 市党员教学课件评比
- 2025年高级建筑师设计原理模拟题集及解答指南
- 2025年电子商务运营助理初级面试指南与答案解析
- 2025年高考数学全真模拟题集及解题技巧指导含答案
- 2025年市场营销岗位面试题解析与实战技巧
- 2025年特岗教师招聘初中语文试题分析与技巧
- 2025年建筑工程师考试模拟试题集含答案详解
- 2025年特种作业类金属非金属矿山安全作业金属非金属矿山井下电气作业-金属非金属矿山支柱作业参考题库含答案解析
- 幼儿园保育员一日生活流程培训
- 2025年上海市新版房屋租赁合同范本
- 2024下半年教师资格证考试《高中语文学科知识与教学能力》真题
- 重症医学进修的学习心得体会
- 中华人民共和国监察法宣贯培训
- 室内地坪施工技术交底
- 部编版三年级语文下册第六单元测试卷(含答案)
- 健康教育高血压课件
- 第一单元 史前时期:原始社会与中华文明的起源 大单元整体说课稿 2024-2025学年部编版七年级历史上学期
- 多耐病人的护理管理
- 《快与慢》说课稿-2024-2025学年沪科版八年级物理上学期
评论
0/150
提交评论