一、10kVS9系列30 kVA1600 kVA双绕组无励磁调压额定 容量(kVA)额定电压联接组标号 空载损耗(kW)负载损耗(kW)空载电流(%)短路阻抗(%)高压(kV)高压分接范围 %低压(kV)3066.31010.51150.4 Y,yn00.1300.6802.14.050Y,yn0D,yn11Y,zn110.1700.8702.0630.2001.0401.9800.2501.2501.81000.2901.5001.61250.3401.8001.51600.4002.2001.42000.4802.6001.32500.5603.0501.23150.6703.6501.14000.8004.3001.05000.9605.1001.0630Y,yn0D,yn111.2006.2000.94.58001.4007.5000.810001.70010.3000.712501.95012.8000.616002.40014.5000.6S9系列630 kVA6300 kVA双绕组无励磁调压变压器额定 容量(kVA)额 定 电 压联接组标号 空载损耗(kW)负载损耗(kW)空载电流(%)短路阻抗(%)高压(kV)高压分接范围 %低压(kV)63066.31010.511533.156.3Y,d111.2306.2001.44.58001.4507.5001.45.510001.72010.0001.212502.00012.0001.216002.45014.5001.120003.00018.0001.125003.50019.0001.131504.10023.0001.140001010.5113.156.35.00027.0001.050006.00031.5000.963007.00035.0000.9S9系列200 kVA1600 kVA双绕组有载调压变压器额定 容量额定电压联接组标号 空载 损耗(kW)负载 损耗( kW)空载 电流(%)短路 阻抗(%)高压(kV)高压分接范围 %低压(kV)20066.3104X2.5 0.4Y,yn0D,yn110.4802.6001.74.02500.5603.0501.63150.6703.6501.64000.8004.3001.55000.9605.1001.56301.2506.2001.44.58001.4357.5001.410001.74010.3001.312502.00012.8001.216002.45014.5001.0二、35kVS9系列50 kVA31500 kVA双绕组无励磁调压电力变压器额定容量 (kVA)额定电压联接组标号空载损耗(kW)负载损耗(kW)短路阻抗(%)空载电流(%)高压(kV)低压(kV)503550.4Y,yn00.2201.2156.521000.3002.0251.81250.3402.3851.51600.3802.8351.42000.4403.3301.32500.5103.9601.23150.6104.7701.24000.7405.7601.15000.8656.9301.16301.0408.2801.08001.2309.9000.810001.44012.1500.812501.76014.6700.716002.12017.5500.68003553.156.310.5Y,d111.2309.9001.0510001.44012.1501.012501.76014.6700.916002.12017.5500.8520002.72019.3500.7525003.20020.7000.7531503538.553.156.310.53.80024.3007.00.740004.52028.8000.750005.40033.0300.663006.56036.9007.50.680003538.52X2.53.153.36.36.610.511YN,d119.20040.5000.551000010.88047.7000.551250012.80056.7008.00.51600015.20069.3000.52000018.00083.7000.52500021.28099.0000.43150025.280118.8000.4S9系列2000 kVA12500 kVA双绕组有载调压电力变压器额定容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)低压(kV)2000353X2.5%6.310.5Y,d112.88020.2506.51.025003.40021.7351.031503538.53X2.5%6.310.54.04026.0107.00.940004.84030.6900.950005.80036.0000.8563007.04038.7007.50.8580003538.53X2.5%6.36.610.511YN,d119.84042.7500.751000011.60050.5800.751250013.68059.8508.00.5三、63kVS9系列6300 kVA63000kVA双绕组有载调压电力变压器额定容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)63006366698X1.256.36.610.511YN,d1110.00036.0009.01.2800012.00042.7501.11000014.24050.4001.11250016.80059.8501.01600020.00073.5301.02000024.00089.1000.92500028.400105.3000.93150033.760126.9000.84000040.400148.5000.85000047.760184.5000.76300056.800222.3000.7S9系列630 kVA63000 kVA双绕组无励磁调压电力变压器额定容量 (kVA)额定电压联接组标号 空载损耗(kW)负载损耗(kW)短路阻抗(%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)63063666956.36.610.511Y,d111.6007.5608.02.0800-9.000-10002.24010.4401.91250-12.600-16003.12014.8501.820003.68017.5501.725004.32020.7001.63150YN,d115.12024.3001.540006.08028.8001.450007.20032.4001.363006366692X2.56.36.610.5119.28036.0009.01.2800011.20042.7501.11000013.20050.4001.11250015.60059.8501.01600018.80073.5301.02000022.00089.1000.92500026.000105.3000.93150030.800126.9000.84000036.800148.9500.85000044.000184.5000.76300052.000222.3000.7四、110kVS9系列6300 kVA120000 kVA双绕组无励磁调压变压器额定容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)63001101212X2.56.36.610.511YN,d119.28036.90010.50.9800011.20045.0000.851000013.20053.1000.81250015.60063.0000.751600018.80077.4000.72000022.00093.6000.652500026.000110.7000.63150030.800133.2000.554000036.800156.6000.55000044.000194.4000.456300052.000234.0000.49000068.000306.0000.3512000084.800379.8000.35S9系列6300 kVA63000kVA三绕组无励磁调压变压器额定容量 (kVA)额定电压联接组标号空载损 耗(kW)负载损耗(kW)短路阻抗 (%)空载 电流(%)高压(kV)中压(kV)低压(kV)升压降压63001102X2.51212X2.53538.56.36.610.511YN,yn0,d1111.20047.700高-中1718高-低10.5中-低6.5高-中10.5高-低1718中-低6.51.0800013.28056.7000.951000015.84066.6000.91250018.40078.3000.851600022.40095.4000.82000026.400112.5000.752500030.800133.2000.73150036.800157.5000.654000043.600189.0000.555000052.000225.0000.56300061.600270.0000.5S9系列6300 kVA63000 kVA双绕组有载调压变压器额定容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)63001108X1.256.36.610.511YN,d1110.00036.90010.51.15800012.00045.0001.11000014.24053.1001.051250016.80063.0001.01600020.24077.4000.952000024.00093.6000.92500028.400110.7000.853150033.760133.2000.84000040.400156.6000.755000047.760194.4000.76300056.800234.0000.65S9系列6300 kVA63000 kVA三绕组有载调压变压器额定容量 (kVA)额定电压联接组标号空载 损耗(kW)负载 损耗(kW)短路阻抗 (%)空载 电流(%)高压(kV)中压(kV)低压(kV)降压63001108X1.25%3538.56.36.610.511YN,yn0,d1112.00047.700高-中10.5高-低1718中-低6.51.19800014.40056.7001.191000017.04066.6001.121250020.16078.3001.121600024.24095.4001.052000028.640112.5001.052500033.840133.2000.983150040.240157.5000.984000048.160189.0000.915000056.960225.0000.916300067.760270.0000.84S9系列6300 kVA63000 kVA双绕组低压为35kV无励磁调压变压器额定容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)63001101212X2.53538.5YN,d1110.00039.60010.51.15800012.00047.7001.11000014.00055.8001.051250016.40066.6001.01600019.60081.9000.952000023.20099.0000.92500027.360116.1000.853150032.400140.4000.84000038.640164.7000.755000046.240204.3000.76300054.640245.7000.65五、220 kVS9系列31500 kVA360000 kVA双绕组无励磁调压变压器额定容量 (kVA)额定电压联接组 标号空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)315002202422X2.5 6.36.610.511YN,d1129.600135.00012140.774000035.200157.5000.775000041.600189.0000.706300049.600220.5000.709000010.513.81165.600288.0000.6312000080.000346.5000.631500001113.815.7596.000405.0000.56180000109.600459.0000.56240000136.000567.0000.4930000015.7518160.000675.0000.42360000184.000774.0000.42S9系列31500 kVA240000 kVA三绕组无励磁调压变压器额定 容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路阻抗 (%)空载 电流(%)高压(kV)中压(kV)低压(kV)升压降压315002202X2.5%2422X2.5%691216.36.610.5113538.5YN,yn0,d1134.4162.0高-中2224高-低1214中-低79高-中1214高-低2224中-低790.774000040.8189.00.705000048.0225.00.636300056.8261.00.639000010.51113.83538.573.6351.00.5612000090.4432.00.561500001113.815.753538.5106.4513.00.49180000121.6585.00.4924000149.6720.00.42S9系列31500240000 kVA双绕组低压为63kV无励磁调压变压器额定容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)315002202X2.5 636669YN,d1132.800151.20012140.984000038.400176.4000.985000045.600211.5000.916300053.600247.5000.919000070.400323.1000.8412000088.000387.9000.84150000103.200453.6000.77180000117.600513.9000.77240000144.000635.4000.70S9系列31500 kVA240000 kVA无励磁调压自耦变压器额定容量 (kVA)额定电压联接组 标号升压组合空载 电流(%)降压组合空载 电流(%)短路阻抗 (%)高压(kV)中压(kV)低压(kV)空载损耗(kW)负载损耗(kW)空载损耗(kW)负载损耗(kW)升压降压315002202X2.5%2422X2.5%1216.610.51113.83538.5YN,a0,d1121.6117.00.6319.299.00.56高-中1214高-低812中-低1418高-中810高-低2834中-6144.00.6323.2121.50.565000029.6170.10.5626.4144.00.496300034.4201.60.5631.2171.00.499000043.2276.30.4939.2234.00.4212000010.51113.815.7518.3538.553.6340.20.4948.0288.00.4215000062.4405.00.4256.0342.00.3518000071.2463.50.4264.0387.00.352400084.8595.80.3576.8504.00.28S9系列31500 kVA180000 kVA双绕组有载调压变压器额定容量 (kVA)额定电压联接组 标号空载 损耗(kW)负载 损耗(kW)短路阻抗 (%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)315002208X1.25 6.36.610.5113538.5YN,d1132.800135.00012140.774000039.200157.5000.705000045.600189.0000.636300054.400220.5000.639000010.5113538.570.400288.0000.5612000085.600346.5000.5615000099.200405.000.49180000115.200468.0000.49S9系列31500 kVA180000 kVA三绕组有载调压变压器额定容量 (kVA)额定电压联接组 标号空载 损耗(kW)负载 损耗(kW)空载 电流(%)容量分配 %短路阻抗 (%)高压(kV)中压(kV)低压(kV)315002208X1.25%691216.36.610.5113538.5YN,yn0,d1137.6162.00.84100/100/100100/50/100100/100/50高-中1214高-低2224中-低794000044.0189.00.775000052.8225.00.706300061.6261.00.709000010.5113538.580.0351.00.6312000097.6432.00.63150000114.4513.00.56180000132.0630.00.56S9系列31,500 kVA240,000 kVA有载调压自耦变压器额定容量 (kVA)额定电压联接组标号空载 损耗(kW)负载 损耗(kW)空载 电流(%)容量分配 %短路阻抗 (%)高压(kV)中压(kV)低压(kV)315002208X1.25%1216.36.610.5113538.5YN,yn0,d1122.4108.90.63100/100/50高-中810高-低2834中-4132.30.635000030.4157.50.566300036.0189.00.569000044.8247.50.4912000010.5113538.556.0308.70.4915000064.0365.40.4218000073.6419.40.4224000088.0540.00.35S9系列63,000kVA180,000kVA有载调压自耦变压器额定容量 (kVA)额定电压联接组标号空载 损耗(kW)负载 损耗(kW)空载 电流(%)容量分配 %短路阻抗 (%)高压(kV)中压(kV)低压(kV)630002208X1.25%1216.36.610.5113538.5YN,yn0,d1136.8171.00.63100/100/50高-中810高-低2834中-8234.00.5612000056.8288.00.5615000010.51113.83538.566.4342.00.4918000075.2391.50.42一、10kVS10系列30 kVA1600 kVA双绕组无励磁调压额定 容量(kVA)额定电压联接组标号 空载损耗(kW)负载损耗(kW)空载电流(%)短路阻抗(%)高压(kV)高压分接范围 %低压(kV)3066.31010.5115 0.4Y,yn00.1100.6801.554.050Y,yn0D,yn11Y,zn110.1500.8701.5630.1751.0401.4800.2001.2501.351000.2301.5001.21250.2701.8001.11600.3102.2001.052000.3752.6000.952500.4553.0500.93150.5403.6500.84000.6504.3000.755000.7755.1000.75630Y,yn0D,yn110.9206.2000.654.5 8001.1207.5000.610001.32010.3000.612501.56012.8000.616001.84014.5000.6S10系列630 kVA6300 kVA双绕组无励磁调压变压器额定 容量(kVA)额 定 电 压联接组标号 空载损耗(kW)负载损耗(kW)空载电流(%)短路阻抗(%)高压(kV)高压分接范围 %低压(kV)63066.31010.5115 33.156.3Y,d111.1006.2000.654.58001.3057.5000.65.510001.55010.0000.612501.80012.0000.616002.02514.5000.620002.70018.0000.625003.15019.0000.631503.70023.0000.640001010.5113.156.34.50027.0000.550005.40031.5000.563006.30035.0000.45S10系列200 kVA1600 kVA双绕组有载调压变压器额定 容量(kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗( kW)空载 电流(%)短路 阻抗(%)高压(kV)高压分接范围 %低压(kV)20066.3104X2.5 0.4Y,yn0D,yn110.4302.6000.954.02500.5003.0500.93150.6003.6500.84000.7204.3000.755000.8655.1000.756301.3506.2000.654.58001.2907.5000.610001.55010.3000.612501.80012.8000.616002.20014.5000.6二、35kVS10系列50 kVA31500 kVA双绕组无励磁调压电力变压器额定容量 (kVA)额定电压联接组标号空载损耗(kW)负载损耗(kW)短路阻抗(%)空载电流(%)高压(kV)低压(kV)50355%0.4Y,yn00.1891.1506.521000.2591.9201.81250.2942.2601.51600.3292.6801.42000.3853.1451.32500.4483.7401.23150.5324.5051.24000.6445.4401.15000.7566.5451.16300.9107.8201.08001.0789.3500.810001.26011.4750.812501.54013.8550.716001.85516.5750.6800355%3.156.310.5Y,d110.1891.1501.0510000.2591.9201.012500.2942.2550.916000.3292.6800.8520001.0789.3500.7525001.26011.4750.7531503538.55%3.156.310.51.54013.85570.740001.85516.5750.750002.38018.2750.663002.80019.5507.50.680003538.52X2.5%3.153.36.36.610.511YN,d113.32522.9500.55100003.95527.200.55125004.72531.19580.5160005.74034.8500.5200008.05038.2500.5250009.52045.0500.43150011.2053.5500.4S10系列2000 kVA12500 kVA双绕组有载调压电力变压器额定容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)低压(kV)2000353X2.5%6.310.5Y,d112.52019.1256.51.025002.97520.5301.031503538.53X2.5%6.310.53.53524.5657.00.940004.23528.9850.950005.07534.000.8563006.16036.5507.50.8580003538.53X2.5%6.36.610.511YN,d118.61040.3750.751000010.15047.7700.751250011.97056.5258.00.5三、63kVS10系列6300 kVA63000kVA双绕组有载调压电力变压器额定容量 (kVA)额定电压联接组标号 空载 损耗(kW)负载 损耗(kW)短路 阻抗(%)空载 电流(%)高压(kV)高压分接范围 (%)低压(kV)63006366698X1.256.36.610.511YN,d118.75034.0009.01.2800010.50040.3751.11000012.46047.6001.11250014.70056.5251.01600017.50069.4451.02000021.00084.1500.92500024.85099.4500.93150029.540119.8500.84000035.350140.2500.85000041.790174.2500.76300049.700209.9500.7S10系列630 kVA63000 kV

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论