1、日本光荣 UNIC 电动执行器 操作手册UINC 系列 旋转型UNIC-Z,05UNIC-10UNIC-20,40UNIC-60,100,150,200(深圳市德美森科技有限公司)( 传真) : +86-755-26471605POST CODE(邮编):518054demeisenQQ : 8 1 585629 1CHINA AGENT (中国代理商)SHENZHEN DEMEISEN SCIENCE & TECHNOLOGY CO,. LTD. TEL (电话) : +86-755- 26471606, 33641458FAXMOBILE PHONE (手机) :+86 -1 89
2、22 8114 28 EMAIL (电子邮件) : demeisen MSN: WEBSITE (网址) : ACT-U01E-2ELECTRIC ACTUATORUnic SeriesROTARY TYPEUnic -乙 05Unic - 10Unic - 20, 40Unic 60, 10050, 200OPERA TION MANUALKoei Industry Co., Ltd.ACT-U01E-2FOR YOUR SAFETYIn order for better and safety use of the product for a long period, please obse
3、rve this “ WARNING and CAUTION “ carefullyHere are the specification and operation manual for the product to prevent suffering injury or loss by accidentsThe contents are divided into "WARNING" and "CAUTION'9 for different degree of risks.* Please strictly observe them, as both of
4、 them are very important for your safety.Improper handling of the product disregarding the notes under thismark may cause injury or death to a man./j CAUTION:Improper handling of the product disregarding the notes under thismark may cause injury or material loss.A WARNINGThis product is not of explo
5、sion-proofDo not use it in the environment with flammable gas (gasoline etc.) or corrosive gasDo not dismantle the actuator from the valve during power operation.Do not make wiring work when power is being supplied/f CAUTION* Do not drop the product or give a shock to the product, lor it may cause d
6、efects to the produc仁* Do not get on the actuator, or it may cause defects or an accident.* Do not make wiring work in the rain or in splashing water.o CONTENTS O1. GENERAL2. CONFIGURATION2-1 Configuration and names of parts2-2 Unic-Z, 052-3 Unic-102-4 Unic-20? 402-5 Unic-60, 100, 150, 2003. SPECIFI
7、CATION4. INSTALLATION4-1 Installation place4-2 Ambient temperature, fluid temperature5. ASSEMBLY WITH A VALVE6. WIRING61 Power and input signals6- 2 Wiring work7. POWER SOURCE AND CIRCUITS7- 1 Power source7- 2 Fuse and breaker7- 3 Circuit diagram8. ADJUSTMENT8- 1 Limit switches and position meter8-
8、2 Intermediate limit switch (option)8-3 Potentiometer (option)8- 4 Mechanical stop9. TEST OPERATION9- 1 Manual operation9- 2 Power operation10. MAINTENANCE / INSPECTION11. TROUBLE SHOOTINGOPTIONAL EXTRASACT-U01E-21. GENERAL"Unic Series" is a super high quality quarter-turn rotary type elec
9、tric valve actuator for on/off and intermediate position service.X FEATURES* Compact and light* Easy of installation and maintenance* Simple structure with fewest trouble* Manual operation by crank handle* Fhennal protection from motor burn-out* Terminal block for simple wiring* Water tightness to N
10、EMA-4X (to IP-66)2. CONFIGURATION2-1 Configuration and names of parts1ACT-U01E-2#ACT-U01E-2NoName1Body: NENLA 4X Housing2Gear Cover3Valve Position Indicator4Limit Switch / Pot Cover5Conduit6Terminal Strip Cover7Manual Over Ride Socket8Output Shaft (Male)9O/R Socket Dust Cover2ACT-U01E-22-2 Unic-乙 05
11、 Configuration7I II II I®8G 34 十 34.o nCMIO2LUnfe-0Tew;4ACT-U01E-22-4 Unic-20, 40 Configuration2-5 Unic-60? 1009 150, 200 ConfigurationCO1 50U-200A3034820 1205U-6O. 1 00U-1 g 200c1371 48.502422S3.5181 El 9 9.6二彳.IIJI"A£ X5GF6ACT-U01E-23. FUNCTIONAL SPECIFICATION*MODELITEMJUnic-ZUnic-0
12、5Unic-10Unic-20Unic-40RATED VOLTAGEAC100/110V±10% (50/60 Hz)AC115/120V ±10% (5Q/60 Hz)AC200/220V±10% (50/60 Hz)AC230/240V±10% (50/60 Hz)RATED CURRENTAC100/110V0.7/0.9A0.65/0.70A1.1/1.2A1.8/2.0AAC115/120V0.6/0.7A0.6Q/0.65A1.Q/1.1A1.6/1.8AAC200/220V0.4/0.5 A0.35/0.40A0.55/0.60A0.9/
13、1.0AAC230/240V0.25/0.30A0.30/0.35A0.5CV0.55A0.7/0.9AOUTPUT SHAFT TORQUE9.8Nm(lkgf-m)39Nm(4kg f-m)98N-m(lOkgf-m)196N*m(20kgf-m)392N-m(40kgf-m)OPERATION SPEED4/3.3sec(50/60IIZ)15/12.5sec(50/601-Iz)3025sec(50/601-Iz)MOTOR8W E-class20W E-class30W E-class90W E-classOPERATION ANGLE0-90°PROTECTORTherm
14、al protectorAMBIENT TEMPERATUREAmbient temperature within : -2555°CINSULATION RESISTANCE1 OOM 办500DCWITHSTAND VOLTAGE1500V AC/1 minuteMANUAL OPERATIONCrank handle attachedSTOPMechanical type(OPEN/CLGSE)ENCLOSURE PROTECTIONWater tightness NEMA-4X(to IP-65)MOUNTING ANGLEFrom vertical to horizonta
15、l anglesPOSITION DETECTIONOPEN/CLOSE limit switchesBODY KIATERIALDie cast AluminumCOATING COLORSilver gray N-6CONDUIT ENTRANCEPl/2x 1 witliresin connectorWEIGHT2.3kg4.5kg7.8kg&5kgACT-U01E-2MODELITEMUnic-60Unic-103Unic-150Unic-200RATED VOLTAGEAC110/110V±10% (50/60 Hz) AC115/120V±10% (50
16、/60 Hz) AC200/220V± 10% (50/60 Hz)AC230/240V±10% (50/60 Hz)RATED CURRENTAC100/110V1.8/2.0A2.9/3.0A3.4/3.5A3.4/3.5AAC115/120V1.7/1.9A2.6/2.8A3.2/3.4A3.2/3.4AAC200/220V1.0/1.1 A1.5/1.6A1.8/1.9A1.8/1,9AAC230/240V0.9/1.0A1.3/1.4A1.6/1.7A1.6/1.7AOUTPUT SHAFT TORQUE588N-m(60kgf-m)981Nm(lOOkgf-n)
17、1471N-m(150kgf-m)1961N-m(200kg f-m)OPERATION SPEED30/25sec(50/60Hz)45/3 8sec(50/60Hz)60/5 Osec(50/60Hz)MOTOR90W E-class100W E-classOPERATION ANGLE0-90。PROTECTORThermal protectorAlvIBIENT TEMPERATUREAmbient temperature within :2555°CINSULATION RESISTANCE100MQ/500DCWITHSTAND VOLTAGE1500V AC/1 min
18、uteMANUAL OPERATIONCrank handle attachedSTOPMechanical type(OPEN/CLOSE)ENCLOSURE PROTECTIONWater tightness NElvlA-4X(to IP-65)MOUNTING ANGLEFrom vertical to horizontal anglesPOSITION DETECTIONOPEN/CLOSE limit switchesBODY MATERIALDie cast AluminumCOATING COLORSilver gray N-6CONDUIT ENTRANCEPl/2 x 1
19、with resin connectorWEIGHT20kg21kg22kg4 CAUTION ON ENVIRONMENTAL INSTALLATION CONDITIONS “INSTALLATION4-1 InsUllationX Caution on indoor installation* The actuators are not of explosionproof type Do not install in a hazardous place* Cover whole the unit, if it is installed at a place where water or
20、materials are splashing.* Resene a space for manual maintenance work.X Caution on outdoor installation* Shade the unit from direct sunlight that may cause overheat and defect to the unit.* Reserve a space for manual maintenance work.Materials and treatment of the unit surfacePARTUnic-Z/05Unic-10Unic
21、-20/40Unic-60/100/150/200BODY BASEDie cast Aluminum Oxidation treatment Electrostatic coatingDRIVING UNIT COVERDie cast Aluminum Oxidation treatment Electrostatic coatingELECTRIC UNIT COVERIleat resisting ABS resin Electrostatic coatingDie cast Aluminum Oxidation treatment Electrostatic coatingCONTR
22、OL UNIT COVERHeat resisting ABS resin Electrostatic coatingDie cast Aluminum Oxidatjon treatment Electrostatic coatingHeat resisting ABS resin Electrostatic coatingDie cast Aluminum Oxidatio n treatment Electrostatic coatingOUTPUT SHAFTSUS 3034-2 AMBIENT TEMPERATURE / FLUID TEMPERATUREX Ambient temp
23、erature* Environmental temperature range for use : -25°C55°C.* For use in minus temperature in-fit space heater is available at option.* For use in temperature beyond the specified range, refer to our Sales Dept.X Fluid temperatureIt is occasional that if the actuator is applied to a high
24、temperature fluid line, the unit may overheat by transmission of lino heat. In such a case, use radiation type bracket and couplings(available at option)* Standard bracket and couplings : Fluid temperature max. 65°C* Radiation type bracket and couplings : Fluid temperature over 65°CA CAUTI
25、ON ON ASSEMBLY WITH A VALVE5. ASSEMBLY WITH A VALVEX Names of partsX Assembly procedurea. Be sure that power is off before making manual operationb. Confirm that a valve smoothly turns by hand without eccentricity, then position it at full close Note : There are some valves designed in reverse direc
26、tion of open/closec. Bolt a bracket on the valved. Tentatively mount an actuator on the bracket with loose boltse. Position the actuator at 0 (close), joint the output shaft and the valve stem with couplingsf. Screw up the boltsg. Check with the attached crank handle if the valve is turns smoothly w
27、ithout ccccntricity.zh CAUTION ON WIRING WORK6. WIRING6- 1 Power and input signalsUse a cable of 仞11mm for the standard connector. (See FIG.7)If a customer connector is used9 select a cable of proper diameter, preventing water ingress to the unit.6- 2 Wiring workUse suflicientlv sealed tubes or cond
28、uit to prevent water ingress.A CAUTION ON USE7. POWER SOURCE AND CIRCUITS7- 1 Pour sourceStandard supplyAC 100/110/115/120V ± 10% (50/60Hz)AC 200/220/230/240V± 10% (50/60Hz)For different supply from the above, refer to our Sales Dept.7- 2 Recommendable fuse and breakerModelCapacity of fuse
29、 breakerMotor capacityUnic-Z, 055A8WUnic-105A20 WUnic-205A30WUnic-407A90 WUnic-607A90 WUnic-1003 50,20010A100WInstall a fuse or breaker for protection according to the following table.Note: V/iring should be made properly to avoid noise disturbance etc.8ACT-U01E-273 Circuit diagramUnic-Z. 05, Standa
30、rd circuit |TermlnaI block'I 6PMThe rmal rot ecto rrOreenOoen limitRevg rsIb i e metorwhiteBlack°Cose I imi tRed.ACTUATORBrownYeilowC loseSwl ten in。contactO Common-、OopenCloseNon-vo i t&ae cont act output誠入MP" OF EXTERNAL cIRCuTT9ACT-U01E-2#ACT-U01E-2Unic10, 20, 40,60, 100, 150, 2
31、00 Standard circuit Terminal block 6PirBrownSwl ten I ng con tactAC9c i oseOpen I ampC1 ose I arnpTUATOREXAMPLE OF EXTERNAL C I RCU I TDo not make parallel operation with plural actuatorsIf they arc operated at the same time through one opcn-closc switch, the actuators may draw abnoimal current into
32、 the units, causing chattering, then disturbance to normal operation.If it goes as is for a long time, actuators may become defectiveConfirm that power is OFF before makins manual operation& ADJUSTMENT8- 1 Adjustment of limit switches and position meter(l)Unic-Z? 051卢4CDlls3'EDIs%i±zr.Z
33、ojLimit DogOutput ShaHLSI: Open limit switchLS2: Open contact outputLS3: Close limit switchLS4: Close contact output1. Fully open the valve by manual handle.Loosen and turn the lower limit dog and confirm that the limit switch is effective.2. For close side, fully close the valve, turn the upper lim
34、it dog, and confirm that the switch is effective.3. Tighten the dog nut up. Adjustment of the valve position indicator is now completed. Contact output positions are also adjusted.* Position limit switch is normally at "B、contact, contact output is at “A” contact, respective!y.(2)Unic-10The upp
35、er limit switch is for close, lower one is for open direction. 2 extra limit switches (contact output) are available at option.1. Open the valve fully by manual handle.Loosen ard turn the lower dog. Confirm that the switch has been off, then screw the dog up.2. Adjust the close side in the same mann
36、er. The adjustment is now over.3. The limit switch is normally at "A" contact.(3)Unic-20, 40 Dog Set ScrewF I 1 1The limit switch at right is for close, left one is for open direction.1. Open the valve fully by manual handle.2. Remove the opening meter3. Loosen and turn the limit dog and c
37、onfinn that the limit switch clicks Then screw up the dog4. Adjust close side in the same manner Adjustment is now over.(4) Unic-60, 100, 150, 200* The limit switches are normally at “B" contact.11ACT-U01E-2#ACT-U01E-2Limit dc>2The limit switch at right is for close, left one is for open dir
38、ection.1. Opcn the valve fully by manual handle.2. Loosen, then set the position meter at full open.3. Loosen, and turn the lower limit dog.Confirm that the limit switch clicks. Then screw up the dog.4. Adjust close side in the same manner.Adjustment is now over.* The limit switches are normally at
39、“B” contact.#ACT-U01E-28- 2 Intermediate limit switch (option)In termediate limit switch can be set at any position.1. After setting the actuator at a desired rate, adjust LS-1 dog to a position where the limit switch clicks2. Set LS-2 in the same manner.* Refer to Fig.l 3 for wiring diagram.Output
40、Shaft /SleeveACT-U01E-2ACT-U01E-28-3 Potentiometer (option)Standard resistance for your choice:135, 500,1000 Q1. Open the valve fully by manual handle.2. Loosen opening-meter gear.3. Applying a tester between 4-5 tenninals on the tenninal block, set the openingmeter at a point where the resistance r
41、ate becomes below 5Q,thcn screw it up.* Refer to Fig4 for wiring diagram.ACT-U01E-2ACT-U01E-2SleevePotentiometerSet screwsLimit DogPot Drive GearFIG. 1 4Output ShaftACT-U01E-28-4 Mechanical stop1. Open the valve fully by manual handle.2. Loosen, and return the stop by l/2 turn with the adjusterbolt.
42、3. Screw up the locknut.4. Acljust close side in the same manner.Adjustment is now over1. Cut power off before making manual operation.2. Insert the manual handle into the hexagonal hole underneath the nabber cap.3. Turn the handle clockwise for close, counter clockwise for open.Note:When making man
43、ual override, be sure to check valve position wilh position indicator.Do not apply excessive force to turn the manual handle beyond the range of Full close/Full open for it may cause troubles.The limit switches become effective at opcn/closc of position mete匚 The stops are at 1/2 turn beyond those p
44、oints. Do not apply excessive force to the han die, for it might damage the unit.<SIZE OF MANUAL HANDLEjModelItem'-Unic-Z/05/10Unic-20Unic-60,100,150,200Opposite of hexagon5mm6mm15mmNumber of handle turns151515Length100mm120mm255mmA CAUTIONWhen making manual operation,be sure that power is of
45、f.If power is on while manual operation,the handle willsuddenly return!9- 2 Power operation京 Before making power operation:* Confirm that the indication on the position meter and the valve opening are matching each other.* Confirm that the circuits are properly wired, also that the unit operates in correct direction with external switches.10. MAINTENANCE, INSPECTION0 LubricationAs the major parts of the products are lubricated with long life d
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 人工智能基础与应用第二版教师课件:项目一
- 医联体政策下合规协同机制
- 2025年实验室安全使用培训课件
- 2025年燃气安全规范培训课件
- 医疗预测模型开发中的患者隐私保护技术
- 医疗隐私保护国际化人才培养战略
- 医疗资源整合:优化患者就医体验的路径
- 浙江省金华市2026年中考历史模拟试卷附答案
- 医疗质量数字化监控投入与不良事件减少
- 急救护理质量控制
- 【新教材】人教PEP版(2024)四年级下册英语 Unit 1 Class rules A Lets talk 教案
- 2026年非煤矿山三级安全教育培训考核试题(及答案)
- 2026年包头职业技术学院单招职业技能测试题库附答案详解(考试直接用)
- 2026海南三亚市吉阳区机关事业单位编外聘用人员、村(社区)工作人员储备库(考核)招聘200人(第1号)考试备考试题及答案解析
- 2026年春季小学信息科技(清华版·贵州)四年级下册教学计划及进度表
- 2025-2026学年下学期初三春季开学第一课
- 聚焦实战破局!零碳园区建设实战指南与路径规划
- 2.1 依宪治国 同步课件 2025-2026学年统编版道德与法治八年级下册
- CRC培训教学课件
- 移动客服培训课件
- 【人卫课件耳鼻喉9版】鼻科学第十一章 儿童和婴幼儿鼻腔、鼻窦炎症性疾病
评论
0/150
提交评论