施耐德无线按钮module_3_第1页
施耐德无线按钮module_3_第2页
施耐德无线按钮module_3_第3页
施耐德无线按钮module_3_第4页
施耐德无线按钮module_3_第5页
已阅读5页,还剩78页未读, 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、XBR5 Implementation March 2011V0.53Estimated time: 40 minSchneider Electric internal use onlyXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Objectives & SummaryReview the range and implementation instructionsAble to Configure the Receiver Teach / unteach b

2、uttons Set outputs Change functionsWhat Is Needed to Follow This Training A Programmable Receiver 2 Transmitter (2 push buttons) The XBR5 Simulator toolDownload SimulatorNextQuick Review of the OfferXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Offer pano

3、ramaCatalog Package offer.XB5RMB03XB5RMA04XB5RFB01XB4RFB01“Package ready to use” In a package the transmitter has been paired to the receiver in the Schneider factory.Configurable receiver 1 complete button with dia 22mm plastic head 1 set of 10 caps1 programmable receiver with 2 relay outputs (24-2

4、40 VAC/DC)Non configurable receiver 1 complete button with dia 22mm plastic head 1 black cap1 receiver with 1 relay output (24 VDC)Non configurable receiver 1 complete button with dia 22mm plastic head 1 black cap1 receiver with 1 relay output (24 VDC)XB5RFA02XB4RFA02Configurable receiver 1 complete

5、 button with dia 22mm plastic head 1 set of 10 caps1 programmable receiver with 2 relay outputs (24-240 VAC/DC)Panel mountingmobile applicationNextXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Offer panoramaComponents offer.TransmitterMetal headZB4RZA0pla

6、stic headZB5RZA0metal head with cap + TransmitterZB4RTAxxxZBRM01Push button + TransmitterZBRRCZBRRASatellite antenna24- 240v AC/DC supplyWhen needed, depending on the applicationPush button headsComplete push button ZBRT1 (*)Plastic head with cap + TransmitterZB5RTAxxxProgrammable receivers 4 PNP ou

7、tputs 24 VDC supply 2 C/O relays outputs 24-240 VAC/DC supply(*) fixing collar ZB*Z009 must be ordered separatlyHandy box (empty)+ZBRA1Implementation and Front face IndicationXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Wiring of ReceiversRelay output ve

8、rsion: PNP output version :(1): For non configurable receiver the fuse is 125mANextXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Transmitter assemblyMounting : similar to Harmony rangeMetallic head ZB4BZ009Plastic head ZB5AZ009:XBR5 ImplementationSchneide

9、r Electric | Industry Business | Training | E.Pauchet | - May 22Fixing the ReceiverScrewing mountingClipped on Rail DinXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Front Face IndicationNavigation / Selection in the menusValidationLed status:Download Expe

10、rt Instruction SheetStartSteady GreenBlinking GreenTeaching and ReceptionXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Teaching / UnteachingReminder: 32 (max number of transmitter per receiver)Teaching:UnteachingWith the transmitterWithout the transmitter

11、 (using ID number)Output 1 and / or Output 2X32 maxXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Typical distance transmitter / receiverApprox 100m* in free field* !Receiver in a metal cabinetRelay antennaApprox 40m*Receiver in a metal cabinetApprox 25m*T

12、he performances are the same whatever the used receiver.(*) Typical values that may be modified by the application environment(*) free field (unobstructed and no radio perturbation)(*) depending on the environment, the distance could be exceeding 40 mXBR5 ImplementationSchneider Electric | Industry

13、Business | Training | E.Pauchet | - May 22Usage of a relay Antenna When If the signal strength LED on receiver is yellow Can be installed at any time to increase the reliability of transmission, in difficult environmentImplementation :Needs only power supply, no settingsNot wired to the receiver or

14、to the transmitterOne relay antenna can be used for one or several receivers / transmittersIt should be located in order to bypass obstaclesWorkshopsXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach

15、a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEndOutput ModesMonostableBistableStart / StopXBR5 ImplementationSchneid

16、er Electric | Industry Business | Training | E.Pauchet | - May 223 Output Modes / 2 Receivers TypeNon configurableOnly available in packages XB5RFB01 / XB4RFB01/ XB5RMB03 Ouput:1 relay COMonostableNo LED No buttonConfigurableIncluded in Packages : XB5RFA02 /XB4RFA02 / XB5RMA04And as Component ZBRRAO

17、nly available as componentZBRRC Power Supply Monostable bistable output function Stop / start output function Buttons for parameterization Reception signal strength Q1, Q2, Q3, Q4 led for output signal Ouput:2 relays COOuputs:4 PNPNextXBR5 ImplementationSchneider Electric | Industry Business | Train

18、ing | E.Pauchet | - May 22Output Mode: Monostable (manufacturing configuration)One click The output close during 500msNext500ms500ms500ms500ms500ms500ms500ms500ms500ms2 push buttons on the same output1 push button on the outputXBR5 ImplementationSchneider Electric | Industry Business | Training | E.

19、Pauchet | - May 22Output Mode: BistableFirst click The output closes Second click The output opensNext2 push buttons on the same relay output1 push button on the relay outputXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22Output Mode: Stop / Start (only rec

20、ommended for simple functions, ie: switch On and Off a resistance)One transmitter closes the outputAn other transmitter opens the outputNext2 push buttons on the same relay outputXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1:

21、Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#1 Teach a Button to Q1-Teach the Gree

22、n Button to Q1-Q1 in MonostableXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#1 Teach Green Button to Q1Steady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#1 Teach Green Button to Q1: Simul

23、atorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#1 Teach Green Button to Q1: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business

24、| Training | E.Pauchet | - May 22#1 Teach Green Button to Q1: Your Turn!Back to MenuSee Simulator DemoDo it yourself !See Video DemoSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1: Teach a Button to Q1#

25、2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#2 Teach a Button to Q2-Teach the Red Button to Q2-Q2 in Mo

26、nostableXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#2 Teach Red Button to Q2Steady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#2 Teach Red Button to Q2: SimulatorThis demo may take some

27、 time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#2 Teach Red Button to Q2: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - Ma

28、y 22#2 Teach Red Button to Q2: Your Turn!Back to MenuDo it yourself !See Simulator DemoSee Video DemoSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teac

29、h Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#3 Teach Additional Button to Q2-In addition to the Red Button, Teach the Blue Button to Q

30、2-Q2 in MonostableXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#3 Teach Additional Button to Q2Steady GreenBlinking Green(In addition to the Red Button)XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#3 Teach Ad

31、ditional Button to Q2: SimulThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#3 Teach Additional Button to Q2: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider

32、Electric | Industry Business | Training | E.Pauchet | - May 22#3 Teach Additional Button to Q2Back to MenuDo it yourself !See Simulator DemoSee Video DemoSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1:

33、 Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#4: Unteach Button from Q1-Unteach Gr

34、een button from Q1-Prerequisite: Green button already paired to Q1 (see exercise #1)XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#4 Unteach a button from Q1Steady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E

35、.Pauchet | - May 22#4 Unteach a button from Q1: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#4 Unteach a button from Q1: VideoThis video may take some time to loadplease be patient.SkipXBR5

36、ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#4 Unteach a button from Q1: Your Turn!Back to MenuSee Simulator DemoSee Video DemoDo it yourself !Steady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May

37、22What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#5: Lo

38、ck the Receiver- Lock the receiverXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#5 Lock the ReceiverHardware lock:Software lock:XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#5: Lock the Receiver: SimulatorThis

39、 demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#5: Lock the Receiver: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E

40、.Pauchet | - May 22#5: Lock the Receiver: Your Turn!Back to MenuDo it yourself !See Simulator DemoSee Video DemoXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Bu

41、tton to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#6 Unlock the Receiver- Prerequisite: receiver already locked (see exercise #5)XBR5 ImplementationSchneid

42、er Electric | Industry Business | Training | E.Pauchet | - May 22#6 Unlock the ReceiverPress & HoldXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#6 Unlock the Receiver: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchn

43、eider Electric | Industry Business | Training | E.Pauchet | - May 22#6 Unlock the Receiver: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#6 Unlock the Receiver: Your Turn!Press & HoldBack to

44、 MenuSee Simulator DemoSee Video DemoDo it yourself !XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: D

45、o a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#7 Set a Bistable Function- Set Q2 as Bistable-Prerequisite: Red push button already paired (see exercise #2)XBR5 ImplementationSchneider Electric | Industry Busine

46、ss | Training | E.Pauchet | - May 22#7 Set Q2 as BistableSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#7 Set Q2 as Bistable: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric |

47、Industry Business | Training | E.Pauchet | - May 22#7 Set Q2 as Bistable: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#7 Set Q2 as Bistable: Your Turn!Steady GreenBlinking GreenBack to Menu

48、See Simulator DemoSee Video DemoDo it yourself !XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a T

49、otal Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: Set a Stop / Start Function#0: Discovering the Output ModesEnd#8 Set a Stop / Start Function- Step1: Set Q1 as Stop / Start- Step2: Stop = Red Push Button- Step3: Start = Green Push ButtonXBR5 ImplementationSchneider Electric | Ind

50、ustry Business | Training | E.Pauchet | - May 22#8-1: Set Stop / Start to Q1Steady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#8-2: Assign Red Button to StopSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry B

51、usiness | Training | E.Pauchet | - May 22#8-3: Assign Green Button to StartSteady GreenBlinking GreenXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#8-1: Set Stop / Start to Q1: SimulatorThis demo may take some time to loadplease be patient.XBR5 Implementa

52、tionSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#8-2: Set Stop to Q1: SimulatorThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#8-3: Set Start Q1: SimulatorThis demo may take

53、some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#8: Test the Stop / Start FunctionThis demo may take some time to loadplease be patient.XBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - M

54、ay 22#8: Set Stop / Start to Q1: VideoThis video may take some time to loadplease be patient.SkipXBR5 ImplementationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22#8: Set Stop / Start to Q1. Your Turn!Back to MenuSee Simulator DemoSee Video DemoDo it yourself !XBR5 Implement

55、ationSchneider Electric | Industry Business | Training | E.Pauchet | - May 22What Do You Want to Learn?#1: Teach a Button to Q1#2: Teach a Button to Q2#3: Teach Additional Button to Q2#5: Lock the Receiver#6: Unlock the Receiver#9: Do a Total Reset#4: Unteach a Button from Q1#7: Set a Bistable Function#8: S

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论