1、AT&S Preliminary DesignOct.27, 2006e90be49015b805740af28b523a7dfe21.pdfPage 1 of 6TABLE OF CONTENTS 目录目录5.5.5Hot Water System (HW) 热水系统.25.5.5.1System Description 系统描述.25.5.5.2Requirements for Hot Water 热水系统的要求.35.5.5.3System Design Criteria 系统设计参数 .35.5.5.4System Component 系统组件.45.5.5.5Drawings
2、 图纸.6AT&S Preliminary DesignOct.27, 2006e90be49015b805740af28b523a7dfe21.pdfPage 2 of 65.5.5Hot Water System (HW) 热水系统热水系统General 概述概述There are 6 hot water boilers at the boiler room for Plant III to provide hot water (80=C Supply/60=C Return) pressurised by hot water pumps to AC equipment, Proc
3、ess equipment in production building as shown in the schematic drawings.由设置在锅炉房的 6 台热水锅炉通过热水水泵提供热水(80=C 供水/60=C 回水)到相对应的生产厂房的空调设备和工艺设备,如系统图所示。5.5.5.1System Description 系统描述系统描述In boiler room for plant III 6 boilers are to be installed for the heating system as the main resource, 5 on duty, 1 for sta
4、ndby for Phase III including 1 boiler for future flex area. Each unit will be sized at 1350KW. Natural gas will be fuel for boilers full operation with maximum usage natural gas fired rate of 144CMH each, and oil is the alternative fuel for standby在锅炉房中设置 6 台锅炉供热,三期为 5 用一备,每台 1350KW。其中包括考虑到将来 Flex 区
5、的扩展将增设一台锅炉. 天然气为锅炉运行的燃料,最大天然气耗量为每台144CMH。6 constant speed duty and standby pumps are provided to supply 80=C Supply and 60=C Return water, which controlled by the BMS system as shown in hot water schematic drawing. 1pump is for future flex area expansion.提供包含备用在内的 6 台定频热水泵,由中央监控系统控制提供 80=C 供水/60=C 回
6、水,参阅热水系统图。其中包括 Flex 区的扩展的一台水泵.Hot water heating system will be a two pipe forced circulation system. The hot water circulating system will include hot water boilers, sealed expansion vessel, chemical dosing tank and hot water circulating pumps, together with piping, accessories and controls.热水供水系统采用
7、两管制机械循环系统,包括热水锅炉、闭式膨胀水箱,热水循环泵,配管,附件、控制元件以及化学投药罐AT&S Preliminary DesignOct.27, 2006e90be49015b805740af28b523a7dfe21.pdfPage 3 of 6Hot water will be provided to the following heating unit: 1) Heating coils in AHUs, RCUs and MAUs for production building.2) Heat exchangers for Process equipment-RODI
8、 and Preheat soft water.热水供至以下设备1) 生产厂房空调箱内 AHUs, RCUs and MAUs 的热盘管。2) 工艺设备(RODI 和 软水预热)的热交换器.Hot water boilers are controlled by temperature sensor installed in hot water return pipe.热水锅炉由安装于热水回水管上的温度传感器控制。5.5.5.2Requirements for Hot Water 热水系统的要求热水系统的要求After calculation, the estimated total heati
9、ng capacity for Plant III is shown below:经过计算,第三厂的热负荷如下:Utility 动力站房1,274KWHDI-CR HDI-洁净区608KWHDI-NCR HDI-非洁净区4,844KWFlex-CR Flex-洁净区643KWFlex-NCR Flex-非洁净区1,172KWRO 反渗透水设备1,221KWPreheat SF 软水预热670KWTotal (总量)10,432KW5.5.5.3System Design Criteria 系统设计参数系统设计参数Boiler Capacity 动力厂房锅炉容量6 x 1,350 kW, 5 d
10、uty 1 standby , (1 for future flex area expansion) 五用一备. (一台锅炉为 flex 区扩展)Hot water pump动力厂房热水循环泵6 x 60 m3/h, 5 duty 1 standby, (1 for future flex area expansion)五用一备. (一台水泵为 flex 区扩展)AT&S Preliminary DesignOct.27, 2006e90be49015b805740af28b523a7dfe21.pdfPage 4 of 6For boiler sizing please refer
11、to load calculation sheet.锅炉的选型详见负荷计算书.5.5.5.4System Component 系统组件系统组件Boiler to be packaged, shop assembled hot water unit complete with:1) Forced draft blower with inlet air pressure sensor and volume control valve2) Burner including pressure regulating devices, gas volume controls, solenoid shuto
12、ff valve, High & low pressure sensors and oil pump3) All required instrumentation and controls4) Unit control panel5) Boiler safety valves6) Stack thermometer7) Burner management system including flame supervision with associated instrumentation and controls.8) Boilers should be equipped with ad
13、equate combustion safety controls such as SSOV (Safety Shut Off Valves), fuel pressure switches, flame detection, and combustion air detection, etc. should be provided as per FM requirement.锅炉应出厂前安装完毕,主要部件包括:1) 带压力感测器和流量控制阀的鼓风机.2) 带调压装置,燃气流量控制电磁关断阀的天燃气燃烧器以及供油泵。3) 必要的仪器和控制元件4) 控制屏5) 锅炉安全阀6) 烟囱温度计7) 燃
14、烧器管理系统包括火焰监测器及相关仪器和控制元件.8) 热水锅炉应配备相关部件以符合 FM 的要求,比如安全关断阀,燃料压力开关,火焰探测以及燃烧空气探测等.AT&S Preliminary DesignOct.27, 2006e90be49015b805740af28b523a7dfe21.pdfPage 5 of 6Hot water Pumps:1) Pumps will be single stage, end suction centrifugal type, constant speed complete with motor, cast-iron casing, bronz
15、e impeller, seals, casing and impeller wearing rings, cast-iron or steel base, stainless steel shaft supported on couplings.2) Mechanical seals will be provided for hot water pumps.3) All pump motor selections will be based on non-overloading through the full range of the pump curve热水泵1) 热水泵为单级单吸式定速
16、离心泵,包括马达,铸铁外壳,青铜叶轮,油封,壳体和叶轮耐磨环,铸铁或钢基,不锈钢轴及联轴器。2) 设置热水泵机械密封.3) 水泵马达的选择需在水泵特性曲线的全部范围内不过载。Sealed expansion tanks and 1 water circulation water pumps with the function of thermal expansion, pressure maintenance, deaeration and water makeup. 闭式膨胀水箱及 1 台热水循环水泵用以定压,除气,补水及容纳膨胀水。Chemical water treatment tank
17、. 化学水处理罐Separated steel stack for steam boiler exhaust in boiler room with relief damper, stack height meet the related local code. 锅炉房内设置锅炉专用金属烟道,每个烟道上设置防爆门,烟道高度符合相关规范。Valve station for every AC unit, equipped with strainer, butterfly or ball valves, pressure gauges, temperature indicators, balance
18、 valve and pneumatic control valve which controlled by temperature sensor in served area.每台空调设备前设置阀站,阀站包括过滤器,蝶阀或球阀,压力表,温度计,平衡阀以及气动温控阀,温控阀由安装在所控区域内的温度传感器控制。Hot water pipe shall be seamless carbon steel with fibreglass + Fire protection paint + aluminium foil(fire resistant, self-extinguish) insulation, and the outsid
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 四川省乐至县联考2025-2026学年初三第三次诊断语文试题含解析
- 2026届天津市新华圣功校初三尖子生班3月调研考试语文试题含解析
- 落实教育公平助学承诺书(5篇)
- 河北省秦皇岛青龙县联考2026届下学期初三年级期末考试(联考卷)英语试题含解析
- 快乐运动的演讲比赛稿15篇
- 企业沟通渠道评估模板优化交流
- 文档编写格式规范工具包
- 物资采购合规管控承诺书6篇
- 环保建材绿色生产承诺书范文5篇
- 多平台文档编辑格式规范
- 消防维保方案(消防维保服务)(技术标)
- 车辆交通危险点分析预控措施
- QC成果提高SBS防水卷材铺贴质量一次合格率
- 大舜号海难事故案例分析
- TGRM 057.1-2023 非煤岩岩爆倾向性评价规范 第1部分:室内指标测定及等级分类
- 2023年安徽新闻出版职业技术学院单招考试职业技能考试模拟试题及答案解析
- LY/T 2271-2014造林树种与造林模式数据库结构规范
- GB/T 6554-2003电气绝缘用树脂基反应复合物第2部分:试验方法电气用涂敷粉末方法
- GB/T 19409-2013水(地)源热泵机组
- GA/T 1047-2013道路交通信息监测记录设备设置规范
- PMPv20流程培训教材-课件
评论
0/150
提交评论