1、1ASON智能特性维护2内容提要内容提要3链路不通类故障维护链路不通类故障维护4控制通道不通维护控制通道不通维护:lmp-get-ccbyport:0,0; LMP_GET_CC_BY_PORT LocalCCID LocalBid LocalPid AdminStatus OperStatus NbrNodeID RemoteCCID DestAddr NextHop 0 x00000005 7 1 AdminUp up 3.3.3.3 0 x00000001 3.3.3.3 3.3.3.3 0 x00000006 7 2 AdminDown down 0.0.0.0 0000000000
2、224.0.0.1 224.0.0.1 0 x00000007 7 3 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x00000008 7 4 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x00000009 8 1 AdminUp up 2.2.2.2 0 x0000000a 2.2.2.2 2.2.2.2 0 x0000000a 9 1 AdminUp up 4.4.4.4 0 x0000000b 4.4.4.4 4.4.4.4 0 x0000000b 10
3、 1 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x0000000c 10 2 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x0000000d 10 3 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x0000000e 10 4 AdminUp config_snd 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 Total records :10 #9-169:s
4、zhw NE169 2005-08-11 11:50:08用命令用命令:lmp-get-ccbyport:0,0查询所有控制通道当前状态信息,选取部分命令响应如下:查询所有控制通道当前状态信息,选取部分命令响应如下:1、正常情况下,这条控制通道的、正常情况下,这条控制通道的AdminStatus应该为应该为AdminUp,OperStatus应该为应该为up,且有正确的远端,且有正确的远端信息,即信息,即NbrNodeID有正确的远端信息。有正确的远端信息。2、控制通道默认是走带内方式,通过、控制通道默认是走带内方式,通过D4-D12字节进行控制通道的发现和管理,光路正常时没有作任何字节进行控
5、制通道的发现和管理,光路正常时没有作任何人为配置,控制通道一般都是正常。人为配置,控制通道一般都是正常。3、当控制通道的状态与正常状态不符时,即存在控制通道不通故障。、当控制通道的状态与正常状态不符时,即存在控制通道不通故障。5控制通道不通维护控制通道不通维护1、物理单板离线,此时相应单板上报BD_STATUS告警。 处理方法:检查物理板是否在位,若离线肯定导致控制通道不通,此时需重新正确拔插单板,并正确添加逻辑板 。2、光纤存在光口级告警导致AdminStatus置为AdminDown。 处理方法:查询当前告警,检查相应板位是否存在光口级告警(R_LOF、R_LOS、IN_PWR_ABN等)
6、,请先解决光口级告警。3、人为设置控制通道的AdminStatus为AdminDown,导致控制通道被关闭。处理方法 :用命令:lmp-get-ccbyport:0,0查询判断AdminStatus是否被设置为AdminDown,若为AdminDown可用命令:lmp-set-ccstatus设置为AdminUp。4、OperStatus状态处于config_snd状态的光口数超过限制。处理方法:若用命令:lmp-get-ccbyport:0,0查询控制通道OperStatus的状态,处于config_snd状态的光口不能超过20个,若个数大于20,用命令:lmp-set-ccstatus将不
7、被智能所用的控制通道AdminStatus状态设置为AdminDown 即可。6控制通道不通维护控制通道不通维护5、光口没有分配到DCC 。 处理方法:光口未分配到DCC,用:cm-get-bdinfo 查询相应光口状态,D4-D12状态是否为port-disable或DCC通信状态为rx_f&tx_f ,利用:cm-set-fiberport使能光口状态。6、光口存在误码导致ECC不通。 处理方法:用命令:per-get-curdata查询光纤光口的误码性能事件,检查是否由于光口存在大量误码而使ECC不通,导致控制链路不通;若存在大量误码请先解决线路误码问题。7、对端网元为非智能网元
8、或者未开启智能 。处理方法 :登陆对端网元,利用:cfg-get-itgattrib查询网元的智能是否开启,未开启时确认是否需要开启智能 ,需要则用命令:cfg-set-itgattrib打开智能,否则需要人为关闭控制通道。8、网元的NodeID设置不正确。处理方法:确定两网元的NodeId被正确设置,若设置不正确则需正确设置NodeID,这种情况比较少见。9、线路板与主控板版本不配套,链路两端线路板版本不配套。处理方法:确定线路板与主控板版本是否配套,链路两端线路板版本是否配套,若存在不配套现象,升级使版本配套解决。7数据链路不通维护数据链路不通维护:lmp-get-dbl:0,0 LMP_
9、GET_DBL LocalDblID LocalBid LocalPid AdminStatus OperStatus RemoteDblID 0 x4c000001 8 1 AdminUp up_free 0 x4c000002 0 x4c000002 9 1 AdminUp up_free 0 x4c000002 0 x4c000005 7 1 AdminUp up_free 0 x4c000001 0 x4c000006 7 2 AdminDown down 0000000000 0 x4c000009 10 1 AdminDown down 0000000000 0 x4c00000a
10、 7 3 AdminDown down 0000000000 0 x4c00000b 7 4 AdminDown down 0000000000 0 x4c00000c 10 2 AdminDown down 0000000000 0 x4c00000d 10 3 AdminDown down 0000000000 0 x4c00000e 10 4 AdminDown down 0000000000 Total records :10 #9-169:szhw NE169 2005-08-11 16:09:02用命令用命令:lmp-get-dbl:0,0查询所有数据链路当前状态信息,选取部分命令
11、响应如下:查询所有数据链路当前状态信息,选取部分命令响应如下:1、正常情况下,确认控制通道正常起来后,相应的数据链路的、正常情况下,确认控制通道正常起来后,相应的数据链路的AdminStatus应该为应该为AdminUp,OperStatus为为up_free,且有正确的远端信息。,且有正确的远端信息。2、控制通道校验通过后,将通过、控制通道校验通过后,将通过J0字节发送字节发送TEST消息进行数据链路连通性校验,消息进行数据链路连通性校验,若数据链路校验不成功,将直接导致若数据链路校验不成功,将直接导致TE链路校验不成功。链路校验不成功。3、数据链路状态与正常状态不符时即存在数据链路不通故障
12、。、数据链路状态与正常状态不符时即存在数据链路不通故障。8数据链路不通维护数据链路不通维护1、逻辑板未配置,或者逻辑板与实际物理板类型不一致 。 处理方法:查询当前告警,是否有BD_NOT_INSTALLED或者WRG_BD_TYPE告警,若有即存在逻辑板未配置或者逻辑板配置错误,利用:cfg-add-board正确填加逻辑板即可解决此问题 。2、人为设置数据链路的AdminStatus状态为AdminDown 。 处理方法:确认控制通道均已经正常起来,用命令:lmp-get-dbl:0,0查询相应的数据链路状态,其AdminStatus为AdminDown。利用:lmp-set-dblsta
13、tus正确设置相应数据链路为AdminUp即可。 在实际运用中,很少出现控制通道校验通过而数据链路不通状况,一般数据链路不通都是由于控制通道不通导致的。9TE链路不通维护链路不通维护:lmp-get-tel:0,0 LMP_GET_TEL LocalTelID LocalBid LocalPid AdminStatus OperStatus NbrNodeID RemoteTelID Verify 0 x6c000001 8 1 AdminUp up 2.2.2.2 0 x6c000002 enable 0 x6c000002 9 1 AdminUp up 4.4.4.4 0 x6c00000
14、2 enable 0 x6c000005 7 1 AdminUp degraded 3.3.3.3 0 x6c000001 enable 0 x6c000006 7 2 AdminDown down 0.0.0.0 0000000000 enable 0 x6c000009 10 1 AdminDown down 0.0.0.0 0000000000 enable 0 x6c00000a 7 3 AdminDown down 0.0.0.0 0000000000 enable 0 x6c00000b 7 4 AdminDown down 0.0.0.0 0000000000 enable 0
15、x6c00000c 10 2 AdminDown down 0.0.0.0 0000000000 enable 0 x6c00000d 10 3 AdminDown down 0.0.0.0 0000000000 enable 0 x6c00000e 10 4 AdminDown down 0.0.0.0 0000000000 enable Total records :10 #9-169:szhw NE169 2005-08-11 14:06:18用命令用命令:lmp-get-tel:0,0查询所有查询所有TE链路当前状态信息,选取部分命令响应如下:链路当前状态信息,选取部分命令响应如下:1
16、、正常情况下,当次网元中控制通道和数据链路均已经正常校验通过后,相应、正常情况下,当次网元中控制通道和数据链路均已经正常校验通过后,相应TE链路的链路的AdminStatus应应该为该为AdminUp,OperStatus应该为应该为up,且有正确的远端信息。,且有正确的远端信息。2、当、当TE链路校验通过后,网元将次链路校验通过后,网元将次TE链路带宽相应信息送到选路模块,标志此链路带宽相应信息送到选路模块,标志此TE链路可以为智能所链路可以为智能所用用 ,TE链路不通直接影响链路不通直接影响LSP的建立和重路由。的建立和重路由。3、控制通道和数据链路的状态直接影响、控制通道和数据链路的状态
17、直接影响TE链路的状态。链路的状态。4、TE链路链路OperStatus出现出现degraded状态时,标志状态时,标志TE链路曾经是链路曾经是Up的,但现在相邻节点间没有可用的控的,但现在相邻节点间没有可用的控制通道,发生了制通道,发生了TE链路降级。此时原有业务不受影响。链路降级。此时原有业务不受影响。5、TE链路状态与上述正常状态不符即存在链路状态与上述正常状态不符即存在TE链路不通故障。链路不通故障。10TE链路不通维护链路不通维护1、人为设置TE链路的AdminStatus为AdminDown,关闭TE链路的一致性校验 。 处理方法:确认控制通道和数据链路均已经正常起来,利用命令:l
18、mp-get-tel:0,0查询TE链路的AdminStatus状态,若为AdminDown则用命令:lmp-set-telstatus设置为AdminUp 。2、相应链路复用段配置不一致 。 处理方法:在智能R1版本中,相应链路建立复用段后,链路属性会发生改变,若存在复用段配置不一致,会因为属性不一致而导致校验不通过。用命令:cfg-get-rmspg和:cfg-get-lmspg检查链路两端节点是否存在单端复用段配置的问题,若存在单端复用段配置,删除单端复用段配置或者将复用段配置完全均可解决问题 。若两端均存在复用段配置,用命令:cfg-get-rmsbdmap和:cfg-get-lmsb
19、dmap查询两端复用段配置是否一致,若不一致配置一致即可。3、单板智能未使能,导致TE链路一致性校验不能完成。处理方法:单板智能未使能会导致控制通道正常,而TE链路为Down。利用:OPTP:bid,0,8b,1,9,f9查询单板智能使能状态,返回1表示使能,0表示不使能,若为0则需要使能单板智能,:OPTP:bid,0,8b,1,9,f8,1即可使能单板智能。 11TE链路不通维护链路不通维护4、光口未分配到ECC字节通信 。 处理方法:光口未分配到DCC原因,利用:cm-get-fiberport查询相应光口DCC状态,D4-D12状态为port-disable或DCC通信状态为rx_f&
20、amp;tx_f,用命令:cm-set-fiberport使能光口状态。 5、设置了错误的远端信息 。 处理方法:利用: lmp-get-tel:0,0 查询相应的TE链路信息,如果查询结果的NbrNodeID错误,与实际的物理连接不一致,利用命令:lmp-set-telremote 重新将NbrNodeID设置正确 ,再利用命令:lmp-set-telverify:TEID 设置相应TE链路校验使能即可。 TE链路大多数情况下是自动发现的,无需人工设置,故状况5不多见。TE链路不通还有可能是J0字节有问题,而J0字节收发不正常原因较多,一般需要开发人员定位。12通过本节学习,看看您是否掌握:
21、通过本节学习,看看您是否掌握:智能软件中常用的校验链路主要有哪些?各种链路相应的故障判断方法?各种链路相应故障的可能原因及解决方措施?回味和思考回味和思考13内容提要内容提要14业务配置不成功类故障维护业务配置不成功类故障维护在配置智能业务时,常遇到的配置不成功错误提示有三种: 计算路由失败 标签分配失败 复用段指定节点错(金级业务) 15智能链路智能链路Vc4:1-16Vc4:17-32Vc4:33-48Vc4:49-6416各各SLA业务对智能链路的使用业务对智能链路的使用R1R1版本版本工作链路工作链路保护链路保护链路无保护链路无保护链路钻石级业务建立钻石级业务建立N NN NY Y钻石
22、级业务重路由钻石级业务重路由N NN NY Y钻石级业务优化钻石级业务优化N NN NY Y金级业务建立金级业务建立Y YN NN N金级业务重路由金级业务重路由1 1N N2 2(degraded)degraded)金级业务优化金级业务优化1 1N N2 2(degraded)degraded)银级业务建立银级业务建立N NN NY Y银级业务重路由银级业务重路由N NN NY Y银级业务优化银级业务优化N NN NY Y铜级业务建立铜级业务建立N NN NY Y铜级业务优化铜级业务优化N NN NY Y铁级业务铁级业务N NY YN N铁级业务优化铁级业务优化N NY YN N17计算路由
23、失败计算路由失败18计算路由失败计算路由失败常见原因及其解决办法:1、确定网络中是否有可用的资源。新建智能业务时:钻石级业务只使用无保护链路,不能使用复用段链路;金级业务只使用复用段工作链路,不能使用无保护链路和复用段链路保护链路;银级业务只使用无保护链路,不能使用复用段链路;铜级业务只使用无保护链路,不能使用复用段链路。 常见现象:网络中有复用段链路,无保护链路资源不足,导致钻石级业务和银级业务建立不成功。 解决方法:现有业务重新进行优化,确保网络中有可用的资源,增加资源,确保网络中有可用的资源。19计算路由失败计算路由失败常见原因及其解决办法:2、查询是否指定了必经链路,若指定了必经链路,
24、检查是否指定的链路属性不正确 ;是否按照希望经过的链路顺序指定多次必经链路。 常见现象:指定链路的属性不正确,未按照希望经过的链路顺序指定多次必经链路,网管版本为V2R1C03B028。 解决方法:重新指定链路,指定正确链路即可。按照希望经过的乱路顺序指定多次必经链路。金级业务将在后续内容讨论。3、查询是否指定了必经节点,若指定必经节点,检查是否按照希望经过的节点顺序指定了多个必经节点。 常见现象:未按照希望经过的节点顺序指定多个必经节点,网管版本为V2R1C03B028。 解决方法:需要按照希望经过的节点顺序指定多个必经节点 。20计算路由失败计算路由失败常见原因及其解决办法:4、现阶段指定
25、必经节点只能指定业务OUT的端口,然在网管上未做此限制,当利用T2000指定必经节点时,指定了业务IN的端口。 常见现象:指定必经节点不正确。 解决方法:只能指定业务OUT的端口。5、查看智能业务经过的节点数是否超过最大节点数限制。 常见现象:智能业务经过的节点数是否超过限制,智能业务所能承受的最大跳数为64跳,即一条智能业务所能经历的最大节点数为65个节点。 解决方法:优化业务配置,尽量使业务不要经过太多HOP,同时HOP增加,业务重路由的概率增大,不利于业务的稳定运行。21标签分配失败标签分配失败22标签分配失败标签分配失败常见原因及其解决办法:1、如果指定了必经节点,需要检查指定的时隙是
26、否已经被使用。利用命令:sc-get-vc4state:bid,pid查询相应的时隙状态,是否为free状态。 常见现象:指定的时隙已经被使用。 解决方法:重新指定另一个时隙。2、检查网元是否存在节点间有单向预留时隙,在链路两端利用命令:sc-get-vc4state:bid,pid查询相应的时隙状态,查看是否存在单端时隙预留状况。 常见现象:存在单端预留时隙,时隙预留不对称。 解决方法:取消单端预留时隙或在链路两端做双向时隙预留。23标签分配失败标签分配失败常见原因及其解决办法:3、查看智能的时隙状态上下游是否一致。 常见现象:时隙上下游状态不一致。 解决方法:在相应的网元执行:sc-syn
27、c-xc网元交叉同步命令,同步主机侧和智能侧的交叉信息。执行此命令后,仍然存在时隙状态上下游不一致,可能存在残留交叉,参考后续内容进行残留交叉清理工作。4、查看是否存在除上述两种情况外的时隙不对称现象。 常见现象:存在时隙不对称,但是不属于时隙预留不对称和智能时隙状态上下游不一致。 解决方法:重新指定另一时隙。24标签分配失败标签分配失败常见原因及其解决办法:5、查看智能业务经过的节点数是否超过最大节点数限制 。 常见现象:智能业务经过的节点数超过限制,智能业务所能承受的最大跳数为64跳,即一条智能业务所能经历的最大节点数为65个节点。 解决方法:优化业务配置,尽量使业务不要经过太多HOP,同
28、时HOP增加,业务重路由的概率增大,不利于业务的稳定运行。25复用段指定节点参数错复用段指定节点参数错#9-158:szhw 1581990-01-19 23:35:44:mpls-activate-lsp;failed! cmd:0 xb80d error:0 x9f00 NSERR_ION_TEM_RC_LOOSE_NODE_FAIL26复用段指定节点参数错复用段指定节点参数错金级业务的限制:由于金级业务比较特殊,其面临的限制也多一些,将详细介绍金级业务的一些限制。1,业务建立时全部使用复用段工作链路,遵循时隙一致性原则。2,当前版本中,金级业务建立时支持指定非跨环节点的松散节点,但只允许
29、在首节点指定一次,如果在其他节点指定非跨环节点时,必须具体到时隙;支持指定跨环节点的松散节点;金级业务指定必经链路时只允许在首节点指定一次必经链路,不允许在其他节点指定必经链路,不允许指定多次必经链路。27复用段指定节点参数错复用段指定节点参数错常见原因及其解决办法:1、查看指定必经链路时是否未考虑当前版本限制。 常见现象:不在首节点指定必经链路或者多次指定必经链路。 解决方法:金级业务目前只支持在首节点指定一次必经链路,取消指定必经链路或只在首节点指定必经链路。2、查看指定必经节点时是否未考虑当前版本限制。 常见现象:指定的松散节点不是跨环节点或不在首节点指定松散必经节点。 解决方法:取消指
30、定必经节点、指定必经节点具体到时隙或在首节点指定一次松散必经节点。28通过本节学习,看看您是否掌握:通过本节学习,看看您是否掌握:智能链路主要有哪三种?各种SLA业务在新建时面临的限制有那些?业务配置时常见的故障有那些,相应的处理方法分别是什么?回味和思考回味和思考29内容提要内容提要30智能软件模块关系智能软件模块关系LIMLMPSCMPLSOSPFCSPF主机软件控制接口信息 接口配置 信息数据链路校验本地业务操作业务路径查询数据链路接口信息LSP建立请求等配置告警信息接口数据、控制 接口信息业务拓扑PPP/DCC命令行、网管控制接口信息Socket QX 洪泛向外发送LSP建立请求等RT
31、M控制拓扑控制拓扑查询31智能业务与三层之间的交互智能业务与三层之间的交互32残留交叉的定义残留交叉的定义智能软件在运行过程中,由于一些异常情况的发生(单站掉电、智能业务异常降级、人为操作触发智能软件固有缺陷等)造成只在某些站点存在的交叉信息。残留交叉,顾名思义就是一些残缺不全的、不能形成完整路径、由于异常情况造成只在少数站点存在的交叉信息信令残留交叉静态残留交叉33信令残留交叉信令残留交叉 智能层智能层情形情形mplsscitgxc12345634信令残留交叉信令残留交叉mpls层信令残留出现mpls层信令残留时,网管上仍然可以查询到相应的lsp信息。出现sc层信令残留时,网管上已经不能查询
32、到相应的lsp信息。35信令残留交叉的定位和处理信令残留交叉的定位和处理用用:mpls-get-mpls/ :mpls-get-smpls查询信令层的查询信令层的lsp信息,选取部分命令相应如下:信息,选取部分命令相应如下::mpls-get-mlsp:all LSP INFO INGRESS SRC_BOARD SRC_PORT SRC_SLOT EGRESS DEST_BOARD DEST_PORT DEST_SLOT INDEX TYPE PROTECTION FIR_SEC 1.1.1.1 7 2 2 3.3.3.3 7 2 2 2 normal_lsp msp first 1.1.1
33、.1 7 2 3 3.3.3.3 7 2 3 3 normal_lsp reroute first 1.1.1.1 7 2 4 3.3.3.3 7 2 4 4 normal_lsp nopr first 1.1.1.1 7 2 1 3.3.3.3 7 2 1 5 normal_lsp sncp second 1.1.1.1 7 2 1 3.3.3.3 7 2 1 5 normal_lsp sncp first Total records :5 #9-169:szhw NE169 2005-08-11 19:00:20:mpls-get-smlsp:all LSP SIMPLE INFO ING
34、RESS EGRESS INDEX INST TYPE PROTECTION DIRECTION CREATE TIME RRTRCVY POSITION STATUS FLAG FIR_SEC NAME 1.1.1.1 3.3.3.3 2 1 normal_lsp msp bi_direction 2005-8-11 18:55:26 disable src up normal first Gold 1.1.1.1 3.3.3.3 3 1 normal_lsp reroute bi_direction 2005-8-11 18:55:44 disable src up normal firs
35、t Silver 1.1.1.1 3.3.3.3 4 1 normal_lsp nopr bi_direction 2005-8-11 18:56:4 disable src up normal first Copper 1.1.1.1 3.3.3.3 5 1 normal_lsp sncp bi_direction 2005-8-11 18:58:22 disable src up normal second Diamond 1.1.1.1 3.3.3.3 5 2 normal_lsp sncp bi_direction 2005-8-11 18:58:21 disable src up n
36、ormal first Diamond Total records :5 #9-169:szhw NE169 2005-08-11 19:00:21这两条命令查询结果一一对应,其区别仅仅是返回内容不同,第一个命令是给网管用的接口,第这两条命令查询结果一一对应,其区别仅仅是返回内容不同,第一个命令是给网管用的接口,第二个命令通过命令行用的多一些。二个命令通过命令行用的多一些。mpls层层lsp信息查询信息查询36:sc-get-lspcb-info:0.0.0.0,0.0.0.0,0 LSP-CB-INFO tunnel-head tunnel-tail tunnel-id lsp-id lsp
37、-xc-index sec_flag in_ifindex in_label out_ifindex out_label label_flag hw_type 1.1.1.1 3.3.3.3 2 1 2 first 0 x4c000006 2 0 x44000002 1 0 x0f 0 x11 1.1.1.1 3.3.3.3 3 1 3 first 0 x4c000006 3 0 x4c000001 64 0 x0f 0 x11 1.1.1.1 3.3.3.3 4 1 4 first 0 x4c000006 4 0 x4c000001 63 0 x0f 0 x11 1.1.1.1 3.3.3.
38、3 5 2 5 first 0 x4c000006 1 0 x4c000002 64 0 x0f 0 x21 1.1.1.1 3.3.3.3 5 1 6 second 0 x4c000006 1 0 x4c000001 62 0 x0f 0 x21 Total records :5 #9-169:szhw NE169 2005-08-11 19:00:40用用:sc-get-lspcb-info/:sc-get-lspcb-exinfo可以查询可以查询lsp-cb信息,下面是命令响应:信息,下面是命令响应:1、正常情况下,此处查询出来的、正常情况下,此处查询出来的SC模块模块LSP信息和信息和
39、MPLS层的应该一致;层的应该一致;2、上述两个命令合起来查询的是实质上是一个内容,即、上述两个命令合起来查询的是实质上是一个内容,即lsp-cb信息,第一个显示常用的基本信息,第二信息,第一个显示常用的基本信息,第二个显示扩展信息(个显示扩展信息(EX););:sc-get-lspcb-exinfo:0 LSP-CB-EXINFO lsp-xc-index lspcb_addr sncp_ptr v_sncp_ptr rvs_exist node_flag sonet_rcc sonet_ncc next_hop est_stat rvs_est_stat 2 0 x0643cb28 000
40、0000000 0000000000 1 0 x01 0 1 4.4.4.4 3 3 3 0 x06445ba8 0000000000 0000000000 1 0 x01 0 1 2.2.2.2 3 3 4 0 x06450168 0000000000 0000000000 1 0 x01 0 1 2.2.2.2 3 3 5 0 x06473268 0 x06475ce8 0000000000 1 0 x01 0 1 4.4.4.4 3 3 6 0 x06475ce8 0 x06473268 0000000000 1 0 x01 0 1 2.2.2.2 3 3 Total records :
41、5 #9-169:szhw NE169 2005-08-11 19:00:42sc层层lsp信息查询信息查询37mpls层信令残留:层信令残留:根据前面的查询得到的根据前面的查询得到的mpls和和sc层的层的lsp信息,比较查询结果:信息,比较查询结果:1,mpls层的层的lsp 信息信息sc层的层的lsp信息不能一一对应,且信息不能一一对应,且sc层的层的lsp数目少于数目少于mpls的的lsp数目,定位出相应的缺少数目,定位出相应的缺少sc层的层的lsp。2,利用利用:cfg-get-itgxc和和:cfg-get-itgsncppg查询主机侧生成的相应的智能交叉信息,查询主机侧生成的相应
42、的智能交叉信息,相应的缺少相应的缺少sc层的层的lsp信息的智能业务存在对应的智能交叉。则存在信息的智能业务存在对应的智能交叉。则存在mpls层信令残留。层信令残留。处理方法:处理方法:1,首先确定此节点相对于此,首先确定此节点相对于此mpls层信令残留的位置。层信令残留的位置。2,若为中间节点,在业务的首节点执行优化操作,将业务优化,若为中间节点,在业务的首节点执行优化操作,将业务优化至其他路径业务即可恢复正常。至其他路径业务即可恢复正常。 3,若为首末节点,重新下发数据配置解决。,若为首末节点,重新下发数据配置解决。38sc层信令残留:层信令残留:根据前面的查询得到的根据前面的查询得到的m
43、pls和和sc层的层的lsp信息,比较查询结果:信息,比较查询结果:1,mpls层的层的lsp 信息信息sc层的层的lsp信息不能一一对应,存在部分信息不能一一对应,存在部分lsp在在mpls层没有相关层没有相关的的lsp信息,而在信息,而在sc层存在相关的层存在相关的lsp信息信息。2,利用利用:cfg-get-itgxc和和:cfg-get-itgsncppg查询主机侧生成的相应的智能交叉信息,查询主机侧生成的相应的智能交叉信息,相应的缺少相应的缺少mpls层的层的lsp信息的智能业务存在对应的智能交叉。则存在信息的智能业务存在对应的智能交叉。则存在sc层信令残留。层信令残留。处理方法:处
44、理方法:3,若,若:sc-get-lspcb-exinfo命令响应的最后一个参数命令响应的最后一个参数 tree_type为为1,运行过程中导致的交叉残,运行过程中导致的交叉残留留 ,先使用,先使用:sc-del-lspcb删除删除sc模块的保留的模块的保留的lsp控制块信息,然后再使用控制块信息,然后再使用sc-sync-xc命令命令与主机软件进行资源同步。与主机软件进行资源同步。1,确认这些,确认这些sc层残留交叉是否处于等待与信令同步层残留交叉是否处于等待与信令同步 。2,若,若:sc-get-lspcb-exinfo:0命令响应的最后一个参数命令响应的最后一个参数 tree_type为
45、为0,正在等待与信令同步,正在等待与信令同步 ,使用使用:sc-del-recovery-lsp:xc_index进行删除进行删除 。若。若xc_index值为值为FFFFFF时,此时需输入时,此时需输入:sc-del-recovery-lsp:0即可删除。即可删除。39静态残留交叉静态残留交叉当网络中存在静态残留交叉时,在当网络中存在静态残留交叉时,在T2000网管系统中路径网管系统中路径SDH路径搜索可以路径搜索可以发现有大量的离散交叉存在。发现有大量的离散交叉存在。通过网管搜索出大量的离散交叉通过网管搜索出大量的离散交叉网管搜索出来的离散交叉可能是静态残留交叉,也可能不是静态残留交叉。网
46、管搜索出来的离散交叉可能是静态残留交叉,也可能不是静态残留交叉。特别在与其他厂家产品对接时、运营商互联互通网络中,需要特别注意。特别在与其他厂家产品对接时、运营商互联互通网络中,需要特别注意。40静态残留交叉静态残留交叉静态残留交叉的定位和处理:静态残留交叉的定位和处理:1,利用,利用:cfg-get-xc和和:cfg-get-sncppg获得主机侧静态交叉信息,利用获得主机侧静态交叉信息,利用:cfg-get-itgxc和和:cfg-get-itgsncppg获得主机侧智能交叉信息。利用获得主机侧智能交叉信息。利用:cfg-get-xcconnect获得获得实际主机侧所有实际生成的交叉信息。
47、实际主机侧所有实际生成的交叉信息。2,判断实际生成的交叉数目是否与静态交叉信息和智能交叉信息之和一致。,判断实际生成的交叉数目是否与静态交叉信息和智能交叉信息之和一致。3,判断是否存在信令残留交叉。,判断是否存在信令残留交叉。4,若存在多余交叉信息,且又不存在信令残留交叉,则存在静态残留交叉。,若存在多余交叉信息,且又不存在信令残留交叉,则存在静态残留交叉。配合网管进行交叉滤除从而得出静态残留交叉信息,配合网管进行交叉滤除从而得出静态残留交叉信息,“主视图网元管理器主视图网元管理器SDH业业务配置务配置”过滤网元对应板位交叉信息。过滤网元对应板位交叉信息。41静态残留交叉静态残留交叉静态残留交
48、叉清理:静态残留交叉清理:1,和客户沟通是否为客户添加单站配置的交叉信息,是则需在链路,和客户沟通是否为客户添加单站配置的交叉信息,是则需在链路另一端预留相应时隙保证时隙上下游一致。另一端预留相应时隙保证时隙上下游一致。2,确认静态交叉不能形成路径,为离散交叉信息(即静态残留交,确认静态交叉不能形成路径,为离散交叉信息(即静态残留交叉)。叉)。3,利用网管路径管理功能或利用命令行,利用网管路径管理功能或利用命令行:cfg-del-xc删除静态残留交删除静态残留交叉,即离散交叉信息。叉,即离散交叉信息。建议:进行残留交叉清理后,需观察一段时间,确认业务无损后离开。建议:进行残留交叉清理后,需观察
49、一段时间,确认业务无损后离开。42通过本节学习,看看您是否掌握:通过本节学习,看看您是否掌握:残留交叉的定义?信令残留交叉主要分两种,其相应的判断方法和处理策略是什么?静态残留交叉的定位和解决方法是什么?回味和思考回味和思考43内容提要内容提要44智能特性巡检维护智能特性巡检维护查询LMP协议控制通道信息,选取部分命令响应如下::lmp-get-ccbyport:0,0; LMP_GET_CC_BY_PORT LocalCCID LocalBid LocalPid AdminStatus OperStatus NbrNodeID RemoteCCID DestAddr NextHop 0 x0
50、0000005 7 1 AdminUp up 3.3.3.3 0 x00000001 3.3.3.3 3.3.3.3 0 x00000006 7 2 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x00000007 7 3 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x00000008 7 4 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x00000009 8 1 AdminUp up 2.2.
51、2.2 0 x0000000a 2.2.2.2 2.2.2.2 0 x0000000a 9 1 AdminUp up 4.4.4.4 0 x0000000b 4.4.4.4 4.4.4.4 0 x0000000b 10 1 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x0000000c 10 2 AdminDown down 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 0 x0000000d 10 3 AdminDown down 0.0.0.0 0000000000 224.0.0.1 22
52、4.0.0.1 0 x0000000e 10 4 AdminUp config_snd 0.0.0.0 0000000000 224.0.0.1 224.0.0.1 Total records :10 #9-169:szhw NE169 2005-08-11 11:50:08根据返回结果确认:根据返回结果确认:为智能所用的光路的控制通道是否处于为智能所用的光路的控制通道是否处于UP态且有正确的远端节点信息。若相邻节点间态且有正确的远端节点信息。若相邻节点间控制通道不正常,参考前面内容对控制通道进行维护。控制通道不正常,参考前面内容对控制通道进行维护。2,不被智能使用的光路的控制通道均已经被关闭
53、,不被智能使用的光路的控制通道均已经被关闭,利用利用:lmp-set-ccstatus关闭不被智能关闭不被智能所用的控制通道。所用的控制通道。45智能特性巡检维护智能特性巡检维护查询LMP协议数据链路信息,选取部分命令响应如下:确认相应的数据链路是否处于正常态,若为非正常态请参考前面内容进行处理。确认相应的数据链路是否处于正常态,若为非正常态请参考前面内容进行处理。:lmp-get-dbl:0,0 LMP_GET_DBL LocalDblID LocalBid LocalPid AdminStatus OperStatus RemoteDblID 0 x4c000001 8 1 AdminUp
54、 up_free 0 x4c000002 0 x4c000002 9 1 AdminUp up_free 0 x4c000002 0 x4c000005 7 1 AdminUp up_free 0 x4c000001 0 x4c000006 7 2 AdminDown down 0000000000 0 x4c000009 10 1 AdminDown down 0000000000 0 x4c00000a 7 3 AdminDown down 0000000000 0 x4c00000b 7 4 AdminDown down 0000000000 0 x4c00000c 10 2 Admin
55、Down down 0000000000 0 x4c00000d 10 3 AdminDown down 0000000000 0 x4c00000e 10 4 AdminDown down 0000000000 Total records :10 #9-169:szhw NE169 2005-08-11 16:09:0246智能特性巡检维护智能特性巡检维护查询LMP协议TE链路信息,选取部分命令响应如下:确认相应的确认相应的TE链路是否处于正常态,若为非正常态请参考前面内容进行处理。链路是否处于正常态,若为非正常态请参考前面内容进行处理。:lmp-get-tel:0,0 LMP_GET_TE
56、L LocalTelID LocalBid LocalPid AdminStatus OperStatus NbrNodeID RemoteTelID Verify 0 x6c000001 8 1 AdminUp up 2.2.2.2 0 x6c000002 enable 0 x6c000002 9 1 AdminUp up 4.4.4.4 0 x6c000002 enable 0 x6c000005 7 1 AdminUp degraded 3.3.3.3 0 x6c000001 enable 0 x6c000006 7 2 AdminDown down 0.0.0.0 0000000000
57、 enable 0 x6c000009 10 1 AdminDown down 0.0.0.0 0000000000 enable 0 x6c00000a 7 3 AdminDown down 0.0.0.0 0000000000 enable 0 x6c00000b 7 4 AdminDown down 0.0.0.0 0000000000 enable 0 x6c00000c 10 2 AdminDown down 0.0.0.0 0000000000 enable 0 x6c00000d 10 3 AdminDown down 0.0.0.0 0000000000 enable 0 x6
58、c00000e 10 4 AdminDown down 0.0.0.0 0000000000 enable Total records :10 #9-169:szhw NE169 2005-08-11 14:06:18在智能里面,当在智能里面,当TE链路一致性校验通过后,网元将链路一致性校验通过后,网元将TE链路信息送往选路模块,链路信息送往选路模块,此时链路真正为智能所用。此时链路真正为智能所用。47智能特性巡检维护智能特性巡检维护:mpls-get-mlsp:all LSP INFO INGRESS SRC_BOARD SRC_PORT SRC_SLOT EGRESS DEST_BOARD
59、 DEST_PORT DEST_SLOT INDEX TYPE PROTECTION FIR_SEC 1.1.1.1 7 2 2 3.3.3.3 7 2 2 2 normal_lsp msp first 1.1.1.1 7 2 3 3.3.3.3 7 2 3 3 normal_lsp reroute first 1.1.1.1 7 2 4 3.3.3.3 7 2 4 4 normal_lsp nopr first 1.1.1.1 7 2 1 3.3.3.3 7 2 1 5 normal_lsp sncp second 1.1.1.1 7 2 1 3.3.3.3 7 2 1 5 normal_l
60、sp sncp first Total records :5 #9-169:szhw NE169 2005-08-11 19:00:20查询信令层的查询信令层的lsp信息,选取部分命令响应:信息,选取部分命令响应:1、正常情况下,智能业务信息跟配置应该是一致的,且上述两条命令查询结果一一对应;、正常情况下,智能业务信息跟配置应该是一致的,且上述两条命令查询结果一一对应;2、这两条命令的区别仅仅是返回内容不同,第一个命令是给网管用的接口,其中第二个命令通过命令行用的、这两条命令的区别仅仅是返回内容不同,第一个命令是给网管用的接口,其中第二个命令通过命令行用的多一些;多一些;3、注意、注意:mpls-get-sm
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年中职农产品营销与储运(农产品批发市场管理)试题及答案
- 2025年中职(助产)产科护理试题及答案
- 2025年大学植物保护(病虫害绿色防控)试题及答案
- 2025年大学网络营销(网络营销)试题及答案
- 2025年高职幼儿综合实训(幼儿综合技能)试题及答案
- 高职第三学年(金融管理)投资理财分析2026年综合测试题及答案
- 2025华钛科技招聘99人考试笔试备考试题及答案解析
- 2025山东阳昇甄选产业运营有限公司选聘7人笔试考试参考题库及答案解析
- 2026年玉溪澄江市教育体育系统招聘毕业生(20人)考试笔试备考题库及答案解析
- 2024年江西科技职业学院马克思主义基本原理概论期末考试题及答案1套
- 2025云南省人民检察院招聘22人笔试考试备考试题及答案解析
- 2025秋期版国开电大本科《心理学》一平台形成性考核练习1至6在线形考试题及答案
- 校园火灾发生时教师如何迅速报警并组织疏散
- 护理人员配置原则与标准
- 血尿病人的护理
- 阿尔及利亚医疗器械法规要求综述
- 为深度学习而教:促进学生参与意义建构的思维工具
- 跨境人民币业务
- 交城县惠丰生物科技有限公司年产10000吨N,N-二甲基苯胺项目环境影响报告书
- 管理运筹学(第三版) 韩伯棠课件第十一章
- GB/T 17215.302-2013交流电测量设备特殊要求第2部分:静止式谐波有功电能表
评论
0/150
提交评论