版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、目录一、工程概况 ················································
2、83;··········································1二、设计说明 ······&
3、#183;·················································&
4、#183;··································31、概述 ··············&
5、#183;·················································&
6、#183;································· 31.11.21.31.4站点概述3建设目标3建设规模及投资3设计原则42、TD-LTE 系统设计目标及技术要求 ······
7、83;·················································
8、83;·····53、信源设计 ···········································&
9、#183;················································53.13.2
10、3.33.43.5信源设计原则5信源选取6小区规划原则6频率配置原则6时隙配置原则74、室内分设计··········································
11、;·······································74.1 覆盖方式74.2 覆盖效果分析74.2.14.2.2传播模型7边缘场强分析84.34.44.5电磁辐射防护分析9RRU
12、供电方式9设计方案10室内分5、主要性能描述··············································
13、183;································115.15.25.3技术指标11主天馈系统技术指标11无源技术指标136、室内覆盖工程施工安装要求·········
14、··················································
15、········ 156.16.26.3主安装要求15GPS 的安装要求16电源安装要求1726.46.56.66.76.86.9天线安装要求17馈线布放要求17安装要求18安装要求19无源有源防雷接地要求19. 196.10其他注意事项20三、 预算部分 ······················
16、;··················································
17、;···············191、预算依据 ·································
18、183;·················································
19、183;······192、工程量及工程总投资·········································&
20、#183;··································212.12.22.3主要安装工程量21工程总投资错误!未定义书签。预算费率取定232.4 预算表 ·······
21、;··················································
22、;····································22四、 图纸部分 ············&
23、#183;·················································&
24、#183;························234.14.2图纸一:系统原理图23图纸二:安装图233一、工程概况表 1-1 站点概况表 1-2系统表1TD-LTE 系统系统标准TD-LTE覆盖情况覆盖范围新建地铁 7 号线龙井站对站台、站厅以及轨道进行。覆盖总面积11000m²覆盖方式有源分主机信源信源类型TD-LTE BBU/1+
25、RRU/1 台基站类型BBU3910小区数1系统带宽20MHz输出功率小区 1:12.2dBm机房位置安装在站厅通信机房内覆盖方案系统规模描述楼层覆盖方式吸顶天线电梯覆盖方式壁挂天线投资工程总额¥8,656.13每平方米投资¥0.79每天线投资¥8,656.13站点名称地铁 7 号线龙井站 F-HLW站点地址市南山区桃源街道办龙珠大道与龙珠四路交汇处地铁 7 号线龙井站经纬度E: 113.96919,N: 22.56753基本环境市南山区桃源街道办龙珠大道与龙珠四路交汇处地铁 7 号线龙井站,1 栋 3F 的地铁站,2 层地下室。总面积 11000 平方米左右。楼
26、层分布1 栋 3F 的地铁站,2 层地下室。电梯分布0 部电梯表 1-3新建规模2新增器件更换器件无调整器件无二、设计说明1、概述1.1、站点概述市南山区桃源街道办龙珠大道与龙珠四路交汇处地铁7 号线龙井站,1 栋 3F 的地铁站,2 层地下室。总面积 11000 平方米左右。图 1.1-1地铁 7 号线龙井站 F-HLW 外观图1.2、建设目标根据公司 TD-LTE 实验网室内综合覆盖工程的建设要求,本次工程对地铁 7 号线龙井站 F-HLW。1.3、建设规模及投资地铁 7 号线龙井站 F-HLW TD-LTE 室内覆盖站点工程建设规模如下表:表 1.3-1 站点规模表3类型规模新增更换TL
27、 信源BBU1RRU1天线吸顶全向天线(个)吸顶定向天线(个)壁挂天线(个)地铁 7 号线龙井站 F-HLW TD-LTE 室内覆盖工程总投资为¥8,656.13 元,每平米造价为¥0.79 元。1.4、设计原则1、室内覆盖建设应遵循以下几项基本原则:LTE 室内分在采流建设方式的情况下,电梯、地下室(若地下室当层商业区面积占比 50%以上,则地下室做双流覆盖)采用分建设,楼层及其他区域采流天馈覆盖。天线的安装建议天线相距 10 倍波长,约为 11.5m,以尽可能满足空间不相关性的要求。(目前吸顶双极化天线尚不成熟,暂不推荐)。建设方式为以下两种:Ø新建、改造LT
28、E 引入室内分后,为了更提升网络性能,需要使用 MIMO双流方式。在工程改造时,LTE通道通过合路器的方式馈入现在的分中,另外通过新建的方式来实现 MIMO。GSM BTSTD- SCDM A&TD- LTE BBUTD- SCDM A RRU合 合 合PATH1TD- LTE RRU4路由7/8'馈线(米)1/2'馈线(米)20光纤(米)无源器件耦合器(个)合路器(个)功分器(个)有源器件光纤(套)0Ø 室内外覆盖覆盖,同时要原则:确保室内分提供良室内好室内信号,避免对室外强干扰。Ø 在频率资源足够、网方式。支持的情况下室内外尽量采用异频组
29、6; TD-LTE 室内分Ø 室内分信号源主要采用 BBURRU。工程的建设必须满家和通信行业相关标准,电磁辐射值应满家标准。Ø 适当保证室内 WLAN 天线和 TD-LTE 的天线的信号源产生强干扰。,尽量避免2、室内覆盖建设应遵循以下基本原则:Ø 若站点现网 TD-SCDMA为261、291、268,则直接更换 RRU为 3151e;Ø 若站点现网 TD-SCDMA更换光模块完成 LTE 升级。为3151,则直接在原有3、涉及到 TD-SCDMA 站点为中兴站点时,全部采取新建一套天馈、利旧馈的设计方案。2、TD-LTE 系统设计目标及技术要求1)
30、无线信道呼损:无线信道呼损不高于 2;2) 无线覆盖区内可接通率:要求在无线覆盖区内的 95位置,99的时间移动接入网络;3)室内分布无线覆盖边缘场强 RSRP>=-105dBm;3、信源设计3.1、信源设计原则目前 TD-LTE 系统主要类型为基带拉远型(BBURRU)基站,基带拉远型(BBU+RRU)能适合各类使用场景,相对于传统的信源具有组网灵活、可分散分布功率资源、易于组成超级小区等优点,非常适合作为各场景下室内覆盖系统的信源,本工程采用基带拉远型(BBURRU)。在进行信号源设计时,要根据主多 RRU 扩展能力进行性的设置,即结合单小区 RRU 最大数量、RRU 级联能力等支持
31、情况,对分5区设置、频率规划、信源组织等方案进行合理设计。3.2、信源选取地铁 7 号线龙井站 F-HLW 的 BBU 安装于 11F 电梯旁弱电间,采用 1 台 RRU为 12.2dBm 直接在安装区域引入交流电后转直流接入供电。3.3、小区规划原则TD-LTE 室内分小区规划应该遵循以下原则:ØTD-LTE 室内分小区规划要充分考虑室内具体环境。规划时重点考虑小区之间的。可以借助物的楼板、墙体等自然屏障产生的穿透损耗形成小区间的。Ø空旷或封闭性较差的室内环境,如:同一楼层由多个小区覆盖的商场、超市,或挑空大堂、体育场馆等开放性室内环境,必须严格不同小区之间的覆盖区域。对
32、于大型场馆等小区间度较低的场景,应采用异频组网。Ø原则上单个小区覆盖面积不宜过大,容量不宜过高,均衡覆盖和容量,从而避免后期容量增加对现网室内分做大的调整。3.4、频率配置原则目前阶段,TD-LTE 的主要工作频段是 23002400MHz。TD-LTE 系统中,RB(Resource Block)是 LTE 系统中用户资源分配的最小。每个 RB 由 12 个 15 kHz 带宽(频带宽度共 180 kHz 左右)的子载波组成。分配给用户的 RB 个数越多,用户数据速率越高,该用户占用的频带总带宽越高。不同信道带宽下的 RB 个数本期室内覆盖系统采用与室外系统异频组网。室内覆盖同一水
33、平层面如需设置多个小区时,相邻小区间建议采用异频组网。在物内可以利用自然阻隔合理进行频率规划。对楼层间较好,可以采用带宽20M 同频组网方式;对同层天然较差的区域,建议采用 2 个 10M 频点6信道带宽(MHz)1.435101520RB 个数6异频组网方式,同层小区间频率交错复用。3.5、时隙配置原则上下行时隙及特殊时隙配置:指 TD-LTE 帧结构中如何配置上行时隙和下行时隙,以及特殊子帧如果配置。本工程建议采用配置模式 1:上下行时隙配置表特殊时隙配置表4、室内分4.1、覆盖方式设计分的天馈部分全部采用无源器件,将大大提高系统在运行时的性,减少将来运行和维护成本。射频分路器件需选用宽频
34、带(800MHz2500MHz)、低损耗器件,减小信号在器件上的损耗。由于多系统合路,对宽频合路器的指标要求较高,宽频合路器需满足以下要求:1)具有优异的通带传输特性。2)通带损耗小;通带匹配特性好,即驻波比小;通带波动小;通带传输时延小。3)各网之间度要高,即合路滤波器应具有优异的阻带抑制特性。4)互调衰减抑制要高,以免造成互调干扰。5)要有足够的功率容量。4.2 、覆盖效果分析4.2.1 传播模型室内无线传播模型相对于室外无线传播模型来说,种类相对较少,目前室内传播模型应用较广的有:Keenan-Motley 模型和 ITU 推荐的 ITU-RP.1238 室内传播模型,推荐使用 ITU-
35、R P.1238 室内传播模型。ITU-R P.1238 模型7正常 CPDwPTSGPUpPTS1022子帧号0123456789DSUUDDSUUDL 20log( f )+ N log(d )+ Lf (n ) - 28dB + XdN :距离损耗系数f:频率,MHz, d > 1md :移动台与发射机之间的距离,为mLf (n )Lf (n )WWPP:穿透损耗系数,=*, :墙壁损耗参考值; :墙壁数目Xd :慢余量,取值与覆盖概率要求和室内慢标准差有关。4.2.2 边缘场强分析边缘场强 = 天线口功率+天线增益-空间传播损耗(含余量)由于室内环境的多样性,而言,进行实际模型测
36、试是比较准确的。本报告余量均根据模测经验值计取。天线增益:3dBi(吸顶天线)楼层天线覆盖半径最远为 8 米,空间传播损耗为:Lr = 28lgd + 20lgf + p*w -28 = 28lg8 + 20lgf + p*w - 28根据模测经验值余量(含墙体损耗)一面墙体时取 15dB,两面墙体取 15×2dB。由此可得楼层距离天线最远 8 米处的边缘场强为:天线口单导频功率+天线增益-空间传播损耗(含余量)= 天线口单导频功率+3-(20lg10+28lgf-28)(dBm)表 4.1-4 楼层边缘场强分析8条件天线口总功率天线口单导频功率天线增益覆盖半径传播损耗边缘场强20M
37、Hz,30dB余量(2 面墙)10-213895-11215-163895-10720MHz,15dB余量(1 面墙)10-213880-9715-163880-9210MHz,30dB余量(2 面墙)10-183895-10915-133895-10410MHz,15dB余量(1 面墙)10-183880-9415-133880-894.3、电磁辐射防护分析根据中民电磁辐射防护规定,即国标GB8702-88,电磁辐射的限值为:公众照射,在一天 24 小时内,环境电磁辐射的场量参数在任意连续6 分钟内的平均值应满足功率密度<0. 4 W/m2 (频率为 303000MHz)。职业照射,在
38、一天8 小时工作时间内,电磁辐射功率密度的平均值(连续 6 分钟) 应<2W/m2 (频率为 303000MHz)。对电磁辐射源豁免的要求为:输出功率等于或小于 15W 的移动无线通信时,电磁辐射体的等效辐射功率小于 100W。,频率为 3-300000MHz本工程天线口最强信号电平为 15dBm(0.035W)时,设活动范围为距天线 1 米以外,则最强功率密度为:0.0025W/m²,其电磁辐足公众照射防护要求,符合规定的电磁辐射标准。4.4、RRU 供电方式室内信号分有源(RRU 等)应采用有保证的-48V 直流供电或 220V 交流供电,尽量不采用无保证的市电直接供电。根
39、据各室内分现场实际情况及 RRU供电要求,建议采用以下供电方式:(1)对于 RRU 直流供电方式及要求RRU 直流应尽量从 BBU 处取电,或在 BBU所在的机房内新建1 套-48V 电源为 RRU 集中供电,其要求如下:A当 RRU 距 BBU 的线缆长度100m 时,用 RRU 厂家标配的供电电缆从 BBU 处的48V 直流电源为其供电。B当 RRU 距 BBU 的线缆长度100m 且300m 时,如果标配的供电电缆不能满足电压降的要求,可通过加粗供电电缆线径从信号源处的48V 直流电源为其供电。C当 RRU 距 BBU 的线缆长度300m 时,或无法从 BBU 处取电时,应在 RRU集中
40、的地方就地配置 1 套小型壁挂式-48V 电源为 RRU供电。(2)对于 RRU 交流供电方式及要求RRU 交流应尽量从 BBU 处取电,或在 BBU所在的机房内新建91 套UPS 电源系统为 RRU供电。如果无法从 BBU 处取电,应在 RRU集中的地方就地配置 1 套小型 UPS 电源为 RRU供电。整个供电系统容量应按远期负荷配置,配电应根据实际情况,配置总交(直)流配电箱、分交(直)流配电箱;总交(直)流电源配电箱安装于 BBU 所在的机房内,分交(直)流配电箱安装于 RRU楼层的墙壁或相应楼层的弱电井内,其配电箱内开关数量、容量应根据实际需求确定,为每个有源应提供的空气开关保护。本方
41、案中,总共有 2 台 RRU,配置 1 载波。每台 RRU 均在各自引市电接入。4.5、室内分1)对室内分设计方案天馈方案进行设计本方案为新建 TD-LTE 系统。(1) 地下停车场天线的安装:采用全向吸顶天线和定向吸顶天线方式进行覆盖。(2)楼层天线的安装:根据楼宇的特点对楼层内覆盖基本采用全向吸顶天线和定向吸顶天线方式进行覆盖,天线为外装,馈线和其他无源器件均在天花板内,结合 4.2.1 节的分析。(3)电梯天线的安装:采用定向壁挂天线方式进行覆盖。(4) 相关天馈系统技术指标参见 5.2 章节。(5)具体天线分布及走线路由情况,参见系统原理图与安装图。(6)GPS 天线的设计:本方案中
42、GPS 天线安装在基站机房顶。2)对室内分进行选择(1) 本次工程选用的无源为:GSM/TD/LTE 合路器,定向壁挂天线,功分器及耦合器。(2) 本室内分选用 2 台单通道 RRU,支持 10MHz 和 20MHz 系统带宽,最大输出功率为 12.2dBm。(3) 相关技术指标参见 5.3 与 5.4 章节。10(4)具体分布,参见系统原理图与安装图。5、主要5.1、主性能描述技术指标*5.2、天馈系统技术指标1)IXD-360/V03-NN 室内吸顶天线表 6.2-1IXD-360/V03-NN 室内吸顶天线技术指标图 6.2-1 IXD-360/V03-NN 室内吸顶天线2)IWH-09
43、0V08NN 型室内壁挂天线表 6.2-2 IWH-090V08NN 型室内壁挂天线技术指标11项目名称指标/性能标准值典型值工作频率824960MHz17102500MHz用途室内吸顶安装, 全向收发增益2.1dBi驻波比1.5水平波束宽度360°垂直波束宽度180°极化方式垂直极化功率容量100W接头N-K阻抗50体积200mm, 高 78mm重量0.5kg图 6.2-2 IWH-090V08NN 型室内壁挂天线波瓣图3)馈线百米损耗对照表12工作频段(MHz)806960 17102500增益(dBi)6.94/8.29电压驻波比8069601.4:11.317102
44、5001.4:11.3水平面半功率波束宽度(°)80696090±15º851710250065±12º63垂直面半功率波束宽度(°)806960约 65°17102500约 55°前后比80696066171025001212三阶交调(dBm)-112-113极化方式垂直极化阻抗()50功率容限(W)80接口型号N-K机械特性安装方式壁挂安装天线罩颜色灰白外形220×180×48重量约 0.5kg表 6.2-3 馈线百米损耗对照表5.3、无源技术指标1)CM-2G3GNN01 合路器表 6.3
45、-1CM-2G3GNN01 合路器技术指标图 6.3-1 CM-2G3GNN01 合路器2)RD-5*N/NP-F2 宽频带功分器表 6.3-2 RD-5*N/NP-F2 宽频带功分器技术指标13用途多系统室内信号分功率分配800960 MHz /17102170 MHz工作频段24002500MHz带内插损0.6dB阻抗50功率容量200W带外抑制CELLULAR60dB24002500 MHzWLAN80dB800960 MHz17102170 MHz回波损耗18dB接头类型N-K 型带内波动0.4dB工作温度-3575重量1.2Kg外形152×115×44mm900M
46、Hz2000MHz2400MHz8D 馈线14.0dB约 23dB约 26dB10D 馈线11.1dB约 18dB约 21dB1/2馈线6.9dB11dB12.1dB7/8馈线3.9dB6dB7.0dB图 6.3-2 RD-5*N/NP-F2 宽频带功分器3)RC-5NK-06/10/15/20F 宽频带耦合器表 6.3-3 RC-5NK-06/10/15/20F 宽频带耦合器技术指标14工作频带8002500MHz耦合度6、10、15、20(dB)插损(不包含分配比)0.1 dB工作频带8002500MHz分配损耗二功分: 3dB三功分: 4.8dB四功分: 6dB插损0.1dB800220
47、0MHz0.2dB22002500MHz阻抗50驻波比二功分:1.2三功分:1.25四功分:1.3功率容量200W接头类型N 型K 头体积二功分:202×43×25mm三功分:202×61×25mm四功分:202×61×43mm重量二功分: 0.36 kg三功分: 0.39 kg四功分: 0.42kg环境温度-40+75相对湿度95%RC-5NK-06/10/15/20F 宽频带耦合器6、室内覆盖工程施工安装要求6.1、主安装要求1)安装位置要求LTE安装位置(见系统与平面图):安装位置无强电、强磁和强腐蚀性的干扰。安装位置保证主机便
48、于调测、维护和散热需要。主机在条件的情况下尽量安装在室内。对于室外安装的主机,须做防雨水贱湿主机箱体底部、防晒、防破坏的措施。对于室内安装的主机,室内不得放置易燃物品;室内的温度、湿度不能超过主机正常工作温度、湿度的范围。2)主机固定主机机架的安装位置应符合设计方案的要求,并且垂直、牢固,并应保证机架底部距离地面 1.5 米,特殊场所除外。3)主机内要求所有的单元的安装单元安装正确、牢固,无损坏、掉漆的现象,无单元的空位应装有盖板。4)外部电缆连接(1) 电源线:15阻抗50驻波比1.2功率容量200W接头类型N-K体积141×24×58mm重量0.3 kg环境温度-305
49、5相对湿度95%主机输入交流电必须火线、零线相对应,不能反接; 连接到主机架的电源线不能和其他电缆捆扎在一起。(2) 射频线:当馈线需要弯曲时,要求弯曲角保持圆滑,其弯曲曲率不能小于下表的规定。所有与相连的电缆要求接触良好,不能有松动的现象,馈线连接处驻波比必须小于等于1.5。表 7.1-1 馈线安装弯曲半径要求5)要求所有连到主机的连线都贴有,并标明该连线的起始点和终止点。主机位置应该有警示牌照及相关服务等,特殊场所出外。6.2、GPS 的安装要求GPS 天线可安装在走线架、铁塔或女儿墙上,GPS 天线必须安装在较空旷位置,上方 90 度范围内(或至少南向 45 度)物遮挡。GPS 天线需安
50、装在避雷针保护范围内。同时建议 GPS 天线安装位置高于其附近金属物一定距离,以避免干扰。GPS 线缆长度应小于 30 米,对于 GPS 安装有的站点可采用特殊使得 GPS 线缆长度达到 200米(1/2 馈线,40dB 高增益天线)图GPS 天线的安装要求16线径二次弯曲的半径一次弯曲的半径7/8”360mm120mm1/2”普通210mm70mm1/2”120mm40mm3/8”150mm50mm6.3 、电源安装要求1) 本工程电源为:AC 220V±15%,功率为 80W,本次工程的 RRU 电源直接取自各弱电井,其电缆采用 RRU 厂家提供的标配电缆。2) 主机接地通过 1
51、6mm²铜线耳及铜线与机房地线相连。6.4、天线安装要求1)天线固定挂墙式天线必须牢固地安装在墙上,保证天线垂直美观,并且不破坏室内整体环境。吸顶式天线可以固定安装在天花吊顶外或天花吊顶内,保证天线水平美观,并且不破坏室内整体环境。如果天花吊顶为石膏板或木质,可以将天线安装在天花吊顶内,但必天线支架对天线做固定,不能任意摆放在天花吊顶内,支架捆绑所用的扎带不可少于 4 条。在天线附近须留有出口位。安装天线时干净手套操作,保证天线及天花板的清洁干净。2)天线位置天线的安装位置符合天线点位的设计要求(相对误差<1 米)。TD-LTE系统天线间隔 1.5 米。TD-LTE 系统天线与
52、 WLAN 天线间隔 2 米以上。详见安装图。3)天线安装天线放置要平稳牢固,如果垂直放置,安放位置要合理美观。天线连接容易,上紧天线时必须先用手拧紧,最后用扳手拧动的范围在 1 圈内即准确到位,要做到布局合理美观,做天线的过程中不能弄脏天花板或其他设施,摘装天花板使用干净的白手套,室内天线接头要用胶带包扎做防水处理,室外天线的接头必须使用的防水胶带,然后用黑胶带缠好,胶带做到平整、少皱、美观,安装完天线后要擦干净天线。6.5、馈线布放要求1)馈线布放馈线必须按照设计文件(方案)的要求布放,要求走线牢固、美观, 不得有交叉、扭曲、裂损情况。跳线或馈线需要弯曲布放时,要求弯曲角保持平滑,弯曲曲率
53、半径不超过下表的规定:17表 7.2-1 馈线安装弯曲半径要求竖线布放要求合理安装,方便器件的制作。穿 PVC 管时,每 1一个扎带固定。横线穿放 PVC 管,要求布放平整,不可捆绑在细的线缆上。在天花板内每 1.5一个扎带固定,明线每 0.6 米一个扎带固定。布放馈线经过的线井应为电井,通常指弱电井,不能使用风管或水管管井。馈线尽量避免与强电高压管道和消防管道一起布放,避免强电、强磁的干扰。对于不在机房、线井和天花吊顶中布放的馈线,应套用 PVC 管。要求所有走线管布放整齐、美观,转弯处使用 PVC 软管连接。走线管靠墙布放,用线码或馈线夹进行固定,其固定间距如下表:表 7.2-2 馈线安装
54、固定要求馈线布放不能有交叉和空中飞线。若走线管无法靠墙布放(如地下停车场),馈线走线管可与其他线管一起走线,并用扎带与其他线管固定。馈线进出口的墙孔应用防水、阻燃的材料进行密封。2)馈线接头馈线的连接头必须牢固,使用的做头工具,严格按照施工工艺制作,保证驻波比小于 1.3,并做防水密封处理。本工程中的所有新增馈线均按照上述安装标准进行安装,工程量表中的馈线长度为估算值,馈线所用的 PVC 管型号及长度详见预算表表。6.6、无源安装要求1)严格按照设计图纸中要求的位置安装。2)应用扎带、固定件固定,不悬空无固定放置。标明编号、建设3)要求:每个器件都要贴的标志。18<1/2"线径
55、馈线>1/2"线径馈线馈线水平走线时1.0m1.5m馈线垂直走线时0.8m1.0m线 径二次弯曲的半径弯曲的半径1/4"软馈30mm-1/2"软馈40mm-1/4”100mm50mm3/8”150mm50mm1/2”210mm70mm7/8”360mm120mm4)接头应做防水密封处理。6.7、有源有源安装要求主要是指干线放大器、光纤分的主机单元、远端单元等。1)安装位置要求的安装位置符合设计文件(方案)的要求;尽量安装在馈线走线的线井内,安装位置应便于调测、维护和散热需要。安装位置确保无强电、强磁和强腐蚀性的干扰。电源插板至少有两芯及三芯插座各一个,工作状
56、态时放置于不易触摸到的安全位置。2)电源线安装有源的电源线接在不间断电源的输出开关,电源线必须走线槽或铁管,线槽或铁管要牢靠固定、保持良接地,配电箱内的走线要美观可参照配电箱内原有的走线,要使用硬线,线槽要美观、牢固。电源线要有移动标志和方向标识。有源3)的安装箱电源必须接到电闸前,不可从电源线剥接。严格按照说明书的进行,使用合理的工具,安装牢固平整。设备上要有移动标志,安装时应用相应的安装件进行牢固固定。要求主机内所有的单元安装正确、牢固、无损伤、掉漆的现象。对于光纤分的主机单元,各模块的安装数量应符合设计文件(方案)的规定。4)接地对于干线放大器、光纤分的主机单元必须接地,并应用16 平方
57、毫米的接地线与。物的主地线连接,保证接地电阻必须小于 56.8、防雷接地要求1)主机接地通过 16mm²铜线耳及铜线。接地铜排与弱电井内的主地线相连;2)馈线接地时用接地卡,通过 16mm²铜线耳及铜线引至弱电井内的地线铜排上;接地卡与馈线连接处理;防水胶和防水胶带做防水处3)地线铜排安装在主主地线相连;的下方,通过铜线耳及铜线与弱电井内的6.9、19如果业主没有特殊要求,需使用统一的,编号应与设计方案保持一致,内容要每个器件的名称、线的方向和长度(两头都要有),馈线每隔 2 米贴一张移动的标志,每个器件和每条馈线都必须有,必要时要用透明胶带加固。主、干放应贴移动通信标识,
58、电梯、地下室在业主同意情况下应粘贴、安装志。移动网络信号覆盖标6.10、其他注意事项1)施工过程中要建立、执行严格的安全管理,现场施工确保全。安2)施工严格按照设计要求进行,做到设计和施工的一致。由工程督导现场负责,如对设计有疑问,应及时和相关设计。三、预算部分预算依据1、本方案不计列信源部分的预算。其中 RRU 和 GPS 的装调测计入室内分的预算。2、暂按 1995 版的预算定额进行计算。因为其中涉及到的需集团或省公司的指导为准。定额室内分安装工程量表各项目说明如下:20序号项目名称执行标准备注1室内天线安装DS7-0182室内天线拆除DS7-0183布放射频同轴电缆 7/8以下DS7-0
59、204拆除射频同轴电缆 7/8以下DS7-0205布放射频同轴电缆 7/8以上.DS7-0216拆除射频同轴电缆 7/8以上.DS7-0217安装调测室内分布式天馈线辅属放大器或中继器DS7-0278安装调测室内分布式天馈线辅 属分路器(功分器,耦合器)DS7-0289拆除室内分布式天馈线辅属设备分路器(功分器,耦合器)DS7-02810分布式天、馈线系统调测DS7-03411安装调测全球天线(GPS)DS7-019用于安装 GPS 天线12安装调测光纤分布远端单元DS7-031适用于安装 RRU3、表四分为需要安装的表、零小安装工程包干费用表、国内主材表,暂不计列仪器仪表工具表:需要安装的表
60、主要:lRRU,各类天馈线、接头、耦合器,以及 GPS 天线和安装材料。l可能用到的各类电缆。零小安装工程包干费用表适用于采用包干方式计列部分小型安装工程费用的省份,主要的项目有:lll避雷针及安装包干费室外走线架安装包干(包工包料)费开墙洞或馈线洞包干费等国内主材表主要:室外走线架(含安装件)、L 型馈线支撑架、封波导材料、室外接地排、密封材料、PVC 管、防火材料及其他零星材料等。4、预备费。其中预备费按(工程费工程建设其他费)的 3计取5、设计费、监理每站估列。6、根据工信厅通(2009)22 号文,取消通信建设工程质量监督费。2 工程量及工程总投资2.1 、主要安装工程量地铁 7 号线
61、龙井站 F-HLW 室内覆盖工程主要安装工程量如下21RRU3161-fae移动集采台1¥0.00¥0.0032光纤跳线()尾纤(15 米/条)移动集采条210.84¥21.6849馈线连接器1/2N移动集采个4¥5.89¥23.5553馈线连接器NM-NF 直角转弯头移动集采个2¥5.13¥10.2659(一)主材计¥55.4960普通阻燃馈线1/2 普通阻燃馈线移动集采米20¥7.42¥148.3661普通阻燃馈线7/8 普通阻燃馈线移动集采米¥17.39¥0.0062(二)馈线计¥148.3685电源线3*2.5mm2金龙羽米10
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年黑龙江省黑河市某学校语文高职单招阅读专项练习测试试题(含答案)
- 《预防医学》试题库与答案
- 编织花束课程设计
- 深度强化学习游戏AI(如Atari)教程课程设计
- 数据可视化数据可视化趋势课程设计
- 基于同态加密的隐私计算原型设计方法课程设计
- 保险专业课程设计
- 采矿学课程设计教学视频
- SolidWorks减速器分析技巧课程设计
- 基于Spark的实时日志分析平台优化与建议课程设计
- 2026年消防设施操作员(初级)考试练习题库附答案详解
- 2026海南热带海洋学院招聘员额制辅导员8人参考题库及完整答案详解【考点梳理】
- 浙江省宁波市2025-2026学年高二下学期6月期末考试政治试题(含答案)
- 夏季食品安全风险与防控
- 2026年国开电大《医药商品营销实务》试题(附答案)
- 2025年威海桃威铁路有限公司招聘笔试参考题库含答案解析
- 中药饮片法律法规培训
- CJJT155-2011 建筑给水复合管道工程技术规程
- 城管协管员笔试考题试题(含答案)大全五篇
- 环卫清扫保洁、垃圾清运及绿化服务投标方案(技术标 )
- 武汉市建筑物停车配建指标
评论