1、Waters UPLC Troubleshooting Training AgendaACQUITY UPLC Family :UPLC & H-ClassWaters UPLC SystemUPLC Solvent Management (BSM)UPLC Sample Management (SM)Waters ACQUITY H-Class SystemQuaternary Solvent Manager (QSM) Sample Manager-Flow Through Needle (SM-FTN)Waters UPLC Detector Troubleshooting Traini
2、ngWaters UPLC PDA and PDAeTUVFLRELSDOpen DiscussionACQUITY UPLC FamilyACQUITY UPLC SystemACQUITY UPLC SystemDetectors:Optical and/or Mass SpecTunable UV or Photodiode ArrayOptimized flow cell for UPLCHigh speed data samplingColumn Manager:Innovative pivot designPositions column to detectorE-Cord con
3、nectionSample Manager:Low dispersion XYZZ FormatFast cycle timesLow carryoverPlates and/or vialsOptional Sample OrganizerBinary Solvent Manager:High pressure blendingBinary gradientsFour solvent choicesOn-line degassingLow dispersion designUPLC pressure capabilitiesSample Organizer: (option)Expands
4、capacity (22/15/8)Shuttles plate feedHeated/chilledSystem Considerations:Small FootprintRedesigned tubing and fittingsConsolidated waste managementIntegrated system diagnosticsConnections Insight remote diagnosticsA1 A2B1B2WasteFluidics and ConnectionsTubing management Chromatographic solvents:A1/A2
5、, B1/B2Two Sample Manager wash solventsSeal WashCommon fittings and tools for usersColumn inlets/outlets and fittings Finger tight, turn (use 1/4” wrench)Dedicated tubing3 piece compression screw and ferruleSmall footprint 13” wide24.25” with Sample OrganizerUPLCSolvent ManagerACQUITY UPLC System So
6、lvent Delivery 15 K psi performanceAccurate and precise flow ratesAccurate and precise compositionLow delay volume for gradient applications5% Ethyl AcetateToluene Chlorinated solvents: (Trichlorobenzene) UPLCSample ManagerSample Manager Fluidics Tray Pressure Transducer Valve Manifold Drive Gears W
7、ash SyringesWeak Wash Strong WashMetering Syringe Drive Assembly Metering Syringe Valve3 Way Rotary ValveMetering Syringe AssemblySample Syringe50 uL volume PN 410001348100 L volume PN 700002570250 L volume PN 410001347for use with 50 L loopColumn Heating CompartmentACQUITY In-Line Filter18Column In
8、-Line Filter AssemblyColumn In-Line Filter AssemblyColumn HeatingSample Manager Flow PathAvailable Loops DescriptionP/NStatus1 L Loop430001516Optional2 L Loop430001264Optional5 L Loop430001233Optional10 L Loop430001326Standard20 L Loop430001320Optional 50 L Loop430001325Optional100 L Loop170001792(K
9、it) Optional250 L Loop176001780(Kit) OptionalVolume Configuration MenuBefore running the Characterize Needle and Loop Volume function, make sure the proper volumes are configured in the Volumes Configuration menu. The above values are standard for currently shipping ACQUITY system.Recommended Inject
10、ion Volumes,Loop Sizes and Injection ModesLoop Volume (uL)Partial Loop w/Needle Overfill Mode Recommended sample injection volume range (uL)Partial Loop (Pressure Assist Mode) Recommended sample injection volume range (uL)Full Loop Mode Recommended sample injection volume (uL0Automatic overfill fact
11、or1uL0.2 to 0.75Not Recommended1.05.82uL0.4 to 1.5Not Recommended2.05.65uL1.0 to 3.8Not Recommended5.0510uL2.0 to 7.52.0 to 5.010.0420uL4.0 to 15.04.0 to 10.020.0350uL10.0 to 37.510.0 to 25.050.02100uL20.0 to 75.020.0 to 50.0100.02250uL40.0 to 150.040.0 to 125.0250.01.5Recommended PLNO injection vol
12、ume 20% to 75% of loop volumeRecommended Partial Loop Injection 20% to 50% of loop volumeACQUITY H-Class SystemQSMQuaternary Solvent Manager SM-FTNSample Manager-Flow Through Needle CH-AHigh Temperature Column HeaterActive Pre-Heating DetectorsTUV, PDA ePDA, FLR, ELSDThe ACQUITY H-Class System consi
13、sts of the following:Quaternary Solvent Manager (QSM)Four solvent low pressure gradient mixing Supports UPLC PressuresLow gradient delay volumeSM-FTN (Sample Manager-Flow Through Needle)One injection mode- direct inject typeMuch simpler- Just specify injection volumeExcellent recovery and precisionC
14、H-AHigh temperature column heater with active pre-heatingACQUITY H-Class SystemQSM Fluidics-Front ViewPrimary HeadAccumulator HeadVent Valve100ul MixerGradient Proportioning Valve PairsLow PressureManifoldDegasser ChambersSeal Wash PumpQSM Console Top Level MenuACQUITY H-Class SystemSMDI Front Panel
15、 FluidicsMetering Syringe ValveCheck Valve and UnionInject ValveWash Solvent Inlet Line (not degassed)Leak Sensor ConnectionsSample Metering SyringeSDMI Inject Valve ConnectionsTo Check ValveTo CH-A and ColumnStationary Side TubeFrom PumpTo Pressure TransducerTo Sample NeedleSample CompartmentPower
16、and Status LEDsPlate Selector SwitchRotary Tray(Plate Holder)Magnetic Door SensorPower SwitchSM-FTN Interactive Display MenuCH-AImproved Door GasketAdded Tubing Gasket (top and bottom)For 3rd party Mass Spec at left side ofACQUITY Stack.Allows use of existingPassive Pre-heaterNo wires to connectActive Pre-heaterInstalling the Active Pre-HeaterGold Plated Compression ScrewPEEK FerruleStainless Steel Cap NutStainless Steel Tubing (with brazed on collet)Installing the Active Pre-HeaterUPLCDetectorsDetectorsSupports all current ACQUITY detec
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 初中垃圾分类设计
- 外研版四年级英语上册复习知识点归纳总结
- 家校共育实施方案完整范文
- 医药行业员工薪资结构报告
- 公司股权激励方案与实施细则
- 第二节 滑冰说课稿2025学年高中体育人教版2019必修第一册-人教版
- 高中化学实验教学方案参考
- 小学数学简便计算技巧专项训练
- 高中留守儿童自强说课稿
- 初中2025自然奥秘发现说课稿
- GB/T 18984-2026低温管道用无缝钢管
- 2026年上海市浦东新区初三下学期二模道德与法治试卷和答案
- 河北石家庄市2026届普通高等学校毕业年级教学质量检测(二)数学试题+答案
- 金昌市金川区玉石沟冶金用石英岩矿产资源开发与恢复治理方案
- 2026年及未来5年市场数据中国钢板桩行业市场深度分析及投资潜力预测报告
- 医院多学科会诊模式优化研究
- 2026年消防安全管理人员资格证考试题库
- 新能源汽车充电桩建设中的法律问题与规制路径研究毕业答辩汇报
- 2025年卫健委工作人员岗位招聘面试参考题库及参考答案
- 数据中心机柜布置方案
- 中国重质氯化镁项目投资可行性研究报告
评论
0/150
提交评论