文档简介

实验数据记录与处理1、实验原始数据记录表次序项目、123456789水蒸气压强MPa0.020.020.020.020.020.020.020.020.02空气进口温度t1°C32.730.328.024.622.121.420.82121.6空气出口温度t2°C74.172.971.970.770.470.771.972.674空气进口处蒸汽温度T1°C103.2103.2103.2103.2103.2103.2103.2103.2103.2空气出口处蒸汽温度t2°c102.3102.3102.3102.3102.3102.3102.3102.3102.3空气流量V(m3/h)23.022.021.018.515.012.6108.57空气进口处密度p(kg/m3)1.15511.16441.17341.18691.19701.19981.20231.20151.1982空气质量流量ms(kg/s)0.00740.00710.00680.00610.00500.00420.00340.00280.0023空气流速u(m/s)31.791830.409629.027325.571720.733817.416413.822511.74929.6758计算公式:①空气进口处密度:p=10-512—4.5义10-311+1.2916空气质量流量:m=Vxp空气流速:u=比九d2

2、给热系数K的计算次序项目123456789空气定性温度t°C平均53.4051.6049.9547.6546.2546.0546.3546.8047.90定性温度下的空气密度P'kg/m31.07981.08601.09181.09991.10481.10571.10451.10291.0989冷、热流体间的对数平均温差At°Cm46..443548.179249.701451.857753.014553.071752.456451.885850.5873总给热系数Kw/(m2°C)151.704125.962120.948108.55990.97278.10065.13356.48248.132计算公式:①空气定性温度:t=1(t+1)(t<60)平均2 1 2空气比热:Cp=1005J/(kg・°C)'定性温度下的空气密度:P'=10-512-4.5X10-31 +1.2916平均 平均冷、热流体间的对数平均温差:At=71T2;-(T2―Jm T-tln^ 2-T-11传热面积:A=冗d21=3.14x0.016x1=0.0502m2对流传热系数:K=,心2-t1)AAtm、近似法求给热系数hh=K=103.1096w/(m2・°C)

4、h理论值的计算序项目、、123456789对流给热系数hw/(m2-°C)151.704125.962120.948108.55990.97278.10065.13356.48248.132空气黏度〃(x10-5Pa-s)1.87821.86651.85531.83871.82641.82301.82001.82101.8249空气导热系数2W/(m-K)0.02700.02680.02660.02630.02620.02610.02610.02610.0261雷诺数Re29243283092732924474200681689913421113659332普兰特数Pr0.69970.69990.70030.70110.70170.70180.70200.70190.7017努赛尔数Nu78.063376.166572.684065.901355.644447.872339.997034.663029.4673努赛尔数理论值Nu'74.643472.654670.659164.717255.232848.143840.041035.102229.9122理论h'W/(m2.°C)125.767121.722117.577106.60590.30078.54365.20557.19748.859h各点的相对误差%-4.72-3.48-2.86-1.82-0.740.560.111.251.4810g.tu/ProJ1.95461.93811.92331.88061.80701.71461.66351.60131.5309log10ge)4.46604.45194.43664.38884.30254.22794.12784.05633.96计算公式:①空气粘度:H=(-2X10-6112+5X10-3t1+1.7169)X10-5②空气导热系数:九=2X10-812+8X10-51+0.0244④普兰特数:Pr=§卢⑤努赛尔数:Nu二㈣九⑥对于流体在圆形只管内做湍流时的对流传热系数若符合以下条件:Re=1.0x10411.2x105,Pr=0.7g120,管长与管内径之->60,则Nu=0.023Re0.8Prnd本实验中,-二=62.5>60,而Re,Pr也基本在这个范围内,n=0.4。所d0.016以可以用上述公式计算Nu的理论值:Nu,=0.023Re0.8Prn⑦理论给热系数:h'二处d⑧相对误差:x⑧相对误差:x100%实验结果与分析1、冷流体给热系数的实验计算值与理论值(Nu/Pro.4=0.023Re0.8)列表比较,计算各点误差,并分析讨论次序项目123456789努赛尔数Nu78.063376.166572.684065.901355.644447.872339.997034.663029.4673努赛尔数理论值Nu'74.643472.654670.659164.717255.232848.143840.041035.102229,9122对流给热系数hw/(m2-°C)151.704125.962120.948108.55990.97278.10065.13356.48248.132理论h'W/(m2.°C)125.767121,722117.577106.60590.30078.54365.20557.19748.859h各点的相对误差%-4.72-3.48-2.86-1.82-0.740.560.111.251.48误差分析:①由于是接着上一组做实验,没有等待仪器冷却,导致实验数据存在误差,前几组数据温度过高。②迪图斯-贝尔特公式(Nu=0.023Reo.8Prn)的条件Re=1.0x104—1.2x105而实验数据有一个没有在此范围之内。所以用此公式算出的Nu'和a2'存在误差。③实验过程中,流量存在波动时,没有取平局值,导致实验误差过大2、冷流体给热系数的准数式:Nu/Pro.4=ARem,以lnNuPr0.4为纵坐标,lnGe)为横坐标,将实验数据的结果标绘在图上,由实验数据作图拟合曲线方程,确定式中常数A及m;并与教材中的经验式Nu/Pr。,=0.023Re0.8比较。29S76一-11-11-11-1QoCE/nsMQIIog(Re) 1og(Nu/Pr0.4))冷流体给热系数的准数式:Nu/Pro.4=丫Rem由图表得拟合曲线方程:y=0.8478x-1.8377贝Um=0.8478(理论值

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论