版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
ParamagneticPhotometricZirconia仕富梅气体分析技术Paramagnetic仕富梅磁氧技术ParamagneticO2O2O2O2O2O2O2O2O2O2O2O2O2O2O2O2COCOCO2CO2SO2HCl
HCl
N2
NO
NO
N2
O2O2COCOCO2CO2SO2SO2HCl
N2
NO2NO2NO2O2O2O2COCOCO2CO2SO2SO2HCl
N2
氧气是唯一对磁场具有很强吸引力的气体,我们称它为“顺磁性”
LED光源
光电池接收器ServomexParamagneticCellParamagnetic磁条充满氮气的球反馈线圈悬浮的镜子Paramagnetic使用一对充满氮气的哑铃来检测氧气哑铃悬浮在一个很强的、不均匀的磁场中Paramagnetic在校验期间,通入氮气使哑铃保持静止位置,从而建立分析仪的零点Paramagnetic样气中的氧气在磁场的作用下,使哑铃发生偏转,由光学反馈系统检测O2O2O2O2O2O2Paramagnetic电流反馈回反馈线圈,产生一个反方向的力距该力距使悬浮回到零位电流正比于氧气的浓度
氧气测量原理样气中的氧气总是设法使得哑铃偏转高精度的反馈回路阻碍哑铃的旋转,给出氧浓度的直接测量值
Paramagnetic仕富梅磁氧技术:
高可靠性
高稳定性
长寿命
高精确度
不受环境气体的影响仕富梅磁氧技术用于........xendos1800/1900...andissuppliedasOEMmodulestoMedicalequipmentmanufacturers.xentra4100xentra49001100A/HPortablesParamagnetic氧分析的原理电化学式顺磁性氧的顺磁性UnpairedelectronsalignwithamagneticfieldandbehavelikesmallmagnetsOxygenmoleculesareattractedintoamagneticfieldNB-Thermalagitationknockselectronsoutofalignmentandreducesmagneticsusceptibility磁氧传感器的类型Magneto-dynamic(Servomex)热/磁风Quinkecell磁风薄的玻璃管气体出口细的铂丝气体入口环形流动室冷态的氧分子受到磁场的吸引磁风测量室的特点热装置容易受到背景气体的导热系数影响TemperaturesensitiveTiltandflowsensitivePressuresensitive(effect=1:1.5)Combustiblesmayburnonfilamentcausingerrors普通的灵敏度QuinkecellQuinkecellfeaturesConstantflowofnitrogenreferencegasrequiredPoorsamplepressuresensitivity-effectofchanges=2:1SuitableforverycorrosivegasesNotaffectedbysamplethermalconductivityServomexparamagneticcellServomexnullbalancesystemMagneto-dynamiccellNullbalancesystem-extremelylinearFastresponse,lowpressureeffect(1:1)VeryhighresolutionTemperaturecompensatedCorrosionresistantmaterialsNotsensitivetothermalconductivityofbackgroundgasesExtremelylonglife-doesnotfail“unsafe”ServomexcellfeaturesEffectofbackgroundgasessmallOperatesupto110C(with1100H)Effectofpressure(1:1)iseasilycompensatedSolventresistantversionavailable(364Ncell)Flammablesamplescanbehandled(ia)electronicsServomex Photometric TechnologiesInfraredGfxServomex Photometric TechnologiesInfraredGfx
SoftUVTransmissionWavelengthEachgasabsorbsenergyintheelectromagneticspectruminauniqueway-itsfingerprint.ServomexPhotometricTechnologiesFingerprintsareusedtoidentifyandanalysespecificcomponentsinasample.InfraredGfxTransmissionWavelengthEachgasabsorbsenergyintheelectromagneticspectruminauniqueway-itsfingerprint.ServomexPhotometricTechnologiesFingerprintsareusedtoidentifyandanalysespecificcomponentsinasample.InfraredGfx
SoftUVServomex Infrared TechnologyInfraredSO2CO2CO58152.0TransmissionWavelength(microns)ServomexSBDWInfraredForthereferencefilter,anabsorptionbandinanareaofthespectrumwherethereisnoabsorptionisselected.Forthemeasurementfilter,anabsorptionbandcorrespondingtotherequiredgasisselected.InfraredServomexInfraredcell
(SingleBeam,DualWavelength-SBDW)FilterwheelIRSource[2-15micron](Broadband,hotwirefilament)ChopperMotorLensSamplecellPyroelectricDetectorLensInfraredWhenthereferencefilterisinthebeam,thereisnoabsorptionbythetargetgasinthesample.Thisgivesazeroreading.ServomexSBDWInfraredRInfraredWhenthemeasuringfilterisinthebeam,energyisabsorbedbythetargetgasinthesample.Thisgivesthespanreading.Thedifferencebetweenthezeroandspansignalsisproportionaltotheconcentrationinthesample.ServomexSBDWInfraredInfraredRMDualBeamIRSensorsDriftresultsfromMeasurementcellcontamination.Ageingdetector,mechanicalmovementSensitiveMicrophonicDiaphramRefrence
CellMeasurementCellInOutRotatingFilterWheelIRSourceCOFilledDetectorServomex Gfx(GasFilterCorrelation) TechnologyGfxServomexGfx
(GasFilterCorrelation)FilterwheelwithgasfilledcellsIRSource[2-15micron](Broadband,hotwirefilament)ChopperMotorLensSamplecellPyroelectricDetectorLensGfxServomexGasFilterCorrelation(Gfx)Somegases-includingCO,CO2,NOandSO2-
haveaspectrumwithafinestructure.Thisallowsitsuseasaspecificandhighlyselectiveopticalfilter.3.558152.5TransmissionWavelengthfinegasstructureGfxWhenthecellfilledwithreferencegas(nitrogen)isinthebeam,thereissomeabsorptionbythetargetgasinthesample.Thisisusedasazeroreading.RGfxServomexGfx
(GasFilterCorrelation)Whenthecellfilledwiththetargetgasisinthebeam,energyisabsorbedbythetargetgasinthesample.Thisgivesthespanreading.Thedifferencebetweenthezeroandspansignalsisproportionaltotheconcentrationinthesample.RMGfxServomexGfx
(GasFilterCorrelation)GasFilterCorrelationHowItWorksUsesagasfiltertoproduceabeamwhichhasalreadyselectivelyabsorbedIRenergyabsorbedbythegastobemeasured,referencedtoabeamwhichhasnot.InfraredAbsorptionLikemanyotherpollutantgases,COabsorbselectromagneticradiationintheinfraredspectrum.TheamountofenergyabsorbedprovidesameasurementoftheCOconcentration.IR
WavelengthAbsorption4.7umCOAbsorbanceInfraredCOSensorsWecanuseaninfraredfiltertoselectonlythosewavelengthscloseto4.7um.IRSourceLensFilterSampleCellDectorInfraredCOSensorsForhighconcentrationCOmeasurements,sensorsusingfilterstoselectthe4.7umregionareideal.ForlowconcentrationCOmeasurementsdualbeamsensorsareoftenused.Thesemeasurementsaresubjecttotwolimitations.CrossSensitivityOthergasesalsoabsorbat4.7umresultingincrosssensitivityerrors.H2OCO2CO4.7umWaveLengthAbsorptionWavelengthstransmittedbyfilter.GasFilterCorrelation.OvercomesbothoftheseproblemsgivingHighsensitivityforlowlevelCOmeasurement.Stable,lowinterferencefrombackgroundgases.IRSpectrumFineStructureTheInfraredspectrumofCOisnotasmoothcurve.WaveLengthAbsorption4.7umLowResolutionAbsorptionspectrumIRSpectrumFineStructureTheInfraredspectrumofCOisnotasmoothcurvebutconsistsofanumberofdistinctlines.WaveLengthAbsorption4.7umHighResolutionDetailBeamspectrumafterNOgasfilterIRSpectrumFineStructureWecanusefiltersfilledwithCOtoselectivelyremoveonlythosewavelengthsdirectlyassociatedwithCO.ThisiscalledGasFilterCorrelationGfxSensorConstructionStableinfraredsourceemitsacollimatedbeamofbroadbandinfraredenergy.WavelengthIntensityGfxSensorConstructionBandpassfilterisolatestheregionoftheIRspectrumofinterestforCO.WavelengthIntensity4.7umGfxSensorConstructionGasfilledcells(Cuvettes)containingCOandN2rotatealternatelyintotheIRbeam.WavelengthIntensity4.7umCOfilledcuvetteN2filledcuvetteGfxSensorConstructionWhenN2cuvetteisinthebeamalloftheIRenergyistransmittedWavelength(expanded)Intensity4.7umCOfilledcuvetteN2filledcuvetteGfxSensorConstructionWhenCOcuvetteisinthebeamthentheIRenergyisremovedonlyatthewavelengthsabsorbedbyCO.Wavelength(expanded)Intensity4.7umCOfilledcuvetteN2filledcuvetteIndividualabsorptionlinesGfxSensorConstructionThealternatingbeampassesdownthesamplecell,throughthegasbeingmeasuredandontothedetector.InOutSampleCellfilledwithgasmeasuredSolidstatedetectorDetectedsignalN2CON2COGfxSensorConstructionThedifferenceinthesignallevelwhenthetwocuvettesareintheIRbeamrepresentsonlytheenergyatthosewavelengthsabsorbedbyCO.InOutDetectedsignalN2CON2COGfxSensorConstructionThesignalsforthetwocuvettesarebalancedelectricallysothatwhenthereisnoCOinthesamplegasthetwolevelsarethesame.InOutDetectedsignalN2CON2CON2CON2COGfxSensorMeasurementsWhenthesamplecontainsnoCOthenthesignalsarebalancedwithnodifference.ThemeasuredCOconcentrationwillbezero.N2CON2CONoCOingassample.GfxSensorMeasurementsWhenthesamplecontainsCOthenthesignalwiththeN2cuvetteisreducedwhilethesignalwiththeCOcuvetteisvirtuallyunchanged.ThedifferencebetweenthesignalsgivestheCOconcentrationinthesamplegas.N2CON2CONoCOingassample.N2CON2CODeltaCOinthegassampleGfxSensorMeasurementsWhenthesamplecontainsanothergaslikeCO2thenthesignalwithbothcuvettesisreducedequally.ThedifferenceinthesignalsiszeroThemeasuredCOconcentrationinthesamplegaswillbezero.N2CON2CONoCOingassample.N2CON2CODeltaCOinthegassampleN2CON2COCO2inthegassampleGfxSensorMeasurementsWhenthesamplecelliscontaminatedorthesourceintensitychangesthenthesignalwithbothcuvettesisreducedequally.ThedifferenceinthesignalsisstillzeroThemeasuredCOconcentrationinthesamplegaswillbezero.N2CON2CONoCOingassample.N2CON2CODeltaCOinthegassampleN2CON2COCellcontaminatedNO,IRfilterandwatervapourspectraPrincipleofoperationServomex SoftUV* Technology
SoftUV*SoftUVislowenergyultravioletradiationgreaterthan250nmServomexSoftUltraVioletcellFilterwheelUVSource[250-900nm](Broadband,hotwirefilament)ChopperMotorLensSamplecellSiliconPhotodiodeDetectorLens
SoftUVTransmission400500600250Wavelength(nm)ServomexSoftUVForthereferencefilter,anabsorptionbandinanareaofthespectrumwherethereisnoabsorptionisselected.
SoftUVForthemeasurementfilter,anabsorptionbandcorrespondingtothetargetgasisselected.
ChlorineWhenthereferencefilterisinthebeam,thereisnoabsorptionbythetargetgasinthesample.Thisgivesazeroreading.ServomexSoftUV
SoftUVRWhenthemeasuringfilterisinthebeam,energyisabsorbedbythetargetgasinthesample.Thisgivesthespanreading.Thedifferencebetweenthezeroandspansignalsisproportionaltotargetgasinthesample.ServomexSoftUV
SoftUVRMServomexPhotometricTechnologies: Reliable Stable Immunetoobscuration Vibrationresistant Solidstatedetector
Gfxoption (superiorselectivityforCO,CO2,NO,SO2)InfraredGfx
SoftUVServomexPhotometrictechnologyisusedin..........andissupplied
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年安全管理人员安全教育培训考试练习题附答案
- 专科护士培训与考核方案
- gb-32276-纺织工业粉尘防爆安全规程培训课件
- 2026四川成都崇州市人力资源开发有限责任公司招聘50人模拟试卷含答案详解【轻巧夺冠】
- 2026职业暴露培训考试试题(附答案)
- 2026事业单位工勤技能-陕西-陕西保育员三级(高级工)历年参考题库含答案详解3卷
- 2026一级造价工程师-建设工程造价管理(官方)-第六章工程建设全过程造价管理参考试题库历年考点答案详解3卷
- 2026重庆大学附属江津医院招聘1人笔试备考题库及答案详解
- 2026年8月浙江嘉兴市方正计量技术有限公司招聘生产操作一线人员笔试备考试题及答案详解
- 2026年广东省连州市教师发展中心公开招聘教研员笔试备考题库及答案详解
- 2026中国智能建筑行业市场分析及发展趋势与投资前景预测研究报告
- 2026江西天然气能源江西天然气能源投资有限公司所属井冈山公司、资溪公司面向社会招聘4人考试参考题库及答案详解
- 中国融通资源开发集团有限公司物资接收、仓储人员专项招聘87人笔试备考试题及答案详解
- 屋面卷材防水施工安全措施
- 第一轮-【黄磷企业检查表】-检查表
- 园区创新创业孵化基地可行性研究报告
- 散热器安装施工工艺流程
- 2026广东江门市规划勘察设计研究院有限公司招聘7人备考题库含答案详解(a卷)
- 2025年重庆市从“五方面人员”中选拔乡镇领导班子成员考试历年参考题库含答案详解
- 文书模板-中标单位情况说明
- 2026第二届全国红旗杯班组长大赛考试备考核心试题库500题
评论
0/150
提交评论