文稿分析案例d023a spe001 specification for clean room finishing_第1页
文稿分析案例d023a spe001 specification for clean room finishing_第2页
文稿分析案例d023a spe001 specification for clean room finishing_第3页
文稿分析案例d023a spe001 specification for clean room finishing_第4页
文稿分析案例d023a spe001 specification for clean room finishing_第5页
已阅读5页,还剩14页未读 继续免费阅读

付费下载

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

D023A-SPE001

REV.A

CONTENT

SUBJECT 3

DESCRIPTION 3

REFERENCEDRAWINGSANDS 3

Codes 3

Referencedrawings 3

DEFINITIONS 4

MINIMUMTECHNICALREQUIREMENTS/ERECTIONTOLERANCES 4

Airtightness(underapressureof50Pa): 4

Flatness(underdeadloadsonly): 4

Verticality 4

Imntation 4

Doors 4

Mechanical /Loadingdata 4

Deflection 5

GENERALREQUIREMENTS(FORCLASSC/D/BSL2ROOMS) 5

Scopeofwork 5

Partitions 6

Ceilings 8

Joinery 8

Floor 10

Miscellaneous 11

Protectionduringsiteworkphase 13

Cleaning 14

SPECIFICREQUIREMENTS 14

Coldroom5° 错误!未定义书签。

Noclassifiedarea 14

APPENDIX 14

SUBJECT

Vaccineproductionbuildingextensionproject.

DESCRIPTION

Workingseedslabisseparatedindifferentworkingzones,whichhavedifferentleveloffinishingandcleannesswithregardtotheirfunctionality.

Workingzonesarethefollowing:

Classifiedareas:

ClassB,withairlockandassociatedrooms,

ClassC,withairlockandassociatedrooms,

ClassD

ClassBSL2andassociatedrooms,

Notclassifiedareas(or“greyareas”):

Thiszoneincludesallroomsaroundtheclassifiedroomswherepharmaceuticaloperationsoccur:Entry,Toilet,changingroometc…

REFERENCEDRAWINGSANDS

Codes

codes

Codeofdesignonbuildingfireprotectionandprevention GB50016-2014

Codefordesignofcleanroom GB50073-2001

Codefordesignofpharmaceuticalindustrycleanroom GB50457-2008

Codeforfirepreventiondesignofinteriordecorationofbuildings

GB50222—95(2001Revision)

CGMP(CurrentGoodManufacturingPractice)

ReferencedrawingsLayouts:

D023A-L01013:1STFLOOR N

D023A-L02013:2NDFLOOR N

D023A-LR1013:ROOF N

D023A-C01013:1STFLOORCEILING N

D023A-A05001:DOORS&WINDOWSLIST&DOOR&WINDOWSDETAILS

DEFINITIONS

-: SanofiPasteur

-Contractor: Therofequipmentand/orserviceforthe

MINIMUMTECHNICALREQUIREMENTS/ERECTIONTOLERANCES

Thepartitionandceilinghavetomeetthefollowingsminimumcharacteristicsregardingtheclassifiedrooms(classB,C,D,BSL2).

Airtightness(underapressureof50Pa):

Allwallsandceiling airleakage<1.m3/h.m²

Doorwithrein d airleakage<1.m3/h

Standarddoors airleakage<3m3/h

Flatness(underdeadloadsonly):

Theassemblysystemsbetweenpanelsandbetweenwindowsandpanelsshallensurethefollowingflatnesstolerances:

Flatnessdefault(undera2mruler)<3mm

Offsetbetween2adjacentpanels<1mm

Verticality

umtoleranceofverticalityis5mmforaheightof3m.

Imntation

Squaringandparallelismhavetobestrictlyrespected. umoutofnetoleranceisabout5mm umoverthelengthofpartition.

Doors

umtoleranceofverticalityissetat2mm.

Mechanical/Loadingdata

Partitionsandceilingshallresisttothefollowingloads:

DeadLoads:

Selfweightof partition/ceilingpanels,includingrein mentsforinserts/reservations

Lightingequipments

Electricalequipments(cabletrays,controlpanel,junctionboxes)

Ventilationequipments(Filters,Exhaust)

LiveLoads:

Maintenanceloads:pointloadof150daN

(correspondingtoonoccasionalmaintenance–for1 –withequipment)

Ceilingshallnotbeconsideredasapermanentaccess,usedforheavymaintenanceordensetrafficduringerectionworks.

Airpressure(duetodifferentialpressurebetweenadjacentrooms):130Pa

Deflection

Deflectionshallbelimitedto1/200thofthespan,includingliveloads,forpartitionsandceilings.

GENERALREQUIREMENTS(FORCLASSBC/D/BSL2ROOMS)

Scopeofwork

Scopeofworkincludesallobligationsarisingfromtheapplicationofnormsandregulationsaswellasthatresultingrepairwork.

Particularlytheseinclude:

Installingthestructures

Surveys,design,constructiondrawingsanddetaildrawingsneededforpartition/ceilingerectionandfortheco-ordinationwiththeothersubcontractorsinvolved(includingparticularlytheissueofsynthesisdrawing,coveringallreservationsinthepartitionandceilingsrequestedbyothersubcontractors)incompliancewiththeprojectguidens.

Supplyandinstallationofpartitionsandceilingspecification,asdefinedinthefollowingspecificationsectionsandinthecontractor’sguidedrawings.

Appropriateprotectionofstructureswithregardtotheactivitiesofothersubcontractors.

Interpretation,understandingandacceptanceofgraphic sdefiningtheworks.Anydifficultyinunderstanding,contradiction,omission,impossibilityorerrorfoundbythesubcontractoristobestatedwhensubmittedhisoffer.

Modificationsmadebythesubcontractorcomparedwiththecontractual s.

Acceptanceofthesupportsneededtoworkthesematerials.

SupplyofsamplesattherequestoftheContractoror .

Cleaningofstructures.

Partitions

Generalrequirements

PolyurethaneorStyrenefoamisbanned.Allpartitionandceilingmaterialsshallhavethefollowingcharacteristics:

Notfl ble,

Firestabilityrating:30minutesminimum,Thepartitionwalloftheevacuationcorridorshouldreachonehourfire rating.

Nodischargeorcollectofparticles(allsteelelementshavetobeconnectingtoearthingsystemtodischargestaticelectricity)

Inerttodevelopmentofmicro-organisms,

Resistanttohumidity,

InsensitivetoUVlight,

Resistanttoacidsandalkalis.

Kcoefficient:2,0W/°C.m2fornotclassifiedrooms,o.58W/°C.m2forclassifiedC/Drooms.

Resistanttocleaninganddecontamination,andshallbeeasytoclean(byusingdetergentsandbleach)

Listofpotentialdecontaminationproducts:

Formaldehydefumigation.

H2O2gasandnebulaedform.

Distributionpartitions

Design

Panelsshallbeprefabricatedandself-bearing.Minimumthicknessofthepartitionshallbe60mm.

TheyshallbeerectedandsetwithaU-Shapefixedonconcretefloor.

Additionalrequirements:

Airtightness:

Upperarea,belowtheceilingandlowerareaatfloorlevelbydoublejointmasticcompound.

Betweenpanelsoneachsideofthechamferedsharpedgesbyamasticcompoundseal.

Allverticalandhorizontalangles(exceptontheground)willbecoveredbyaluminiumsectionepoxyprotectedquarter-circleanglemouldings,sealingwillbeprovidedbyasiliconemasticsealbetweenthesectionandthepanel;atthefootofthepartition ofthesectionwillbeadaptedincaseofaverticalplinth.

ThepanelswillbelaidatgroundlevelinaUchannelmadeofgalvanisedsheetsteelfixedtotheground(includingtheuseofshimstoovoiddifferencesinlevel).

Penetrationsshallbeprovidedfor:

Electricity(sandvariouspowers).

Fluidsinlet/outlet.

Switchesandsignalsforinterlocking,

Measuringequipmentforenvironmentalcontrolineachclassifiedroomstorage,coldroomandfillingcoldroom,

Smokedetectors,Sprinklers,extinguishers,motionsensorandsafetyshowers,

Variousaccessoriesandalltheirconstraints.

Materials

Thepanelsshallconsistoftwosmoothsidesmadeofgalvanisedsteelsheet,pre-enamelledfinishwithamineralwoolinsulatingcore.

Non-fl bleand bustible-firerated30minutesminimumatleast(withtestreport).

Hot-dipgalvanised(mini:class2,Z225).

Pre-enamellingistobehouseholdgrade:5+20microns,colourtobeselectedbyfromthemanufacturer’sstandardrange.

Steelsheetthickness:6/10e(0.6mm)minimum.

Themetalfacingofthepanelshallbecoveredbyanadhesivetransparentprotectivefilmwhichwillberemovedonlyaftererectionandbeforesealing.

Doublepartition

Theseshallhavethesameappearanceanddesignasdistributionpartitions.

Theinvisiblesideshallbesmoothandgalvanised.

Liningpartitions

Thesewillbeofidenticalappearanceanddesigntothe(distribution)(double).

Theinvisiblesideistobesmoothandgalvanised.K=2.0W/°C.m2

Sheetmetallinings

Thesheetmetalliningsaretobeofthesametypeasforpartitionfacings,

Colouristobeidenticaltothatofthepartition,

Thedesignoftheliningsshallprovideperfectorslightlyprojectingflushtothepanelswithnovisiblemeansofatta ents(e.g.rivets)

Allfacingsshallbesealedwithasiliconecompound.

Ceilings

Design

Prefabricatedpanelshavetobeself-supportingorsuspended.Theirminimumthicknesswillbe100mm(unles ceptionallystatedotherwiseinthespecifications)

ThebraceswillbeOmegatypeorother.

Panels’assemblywillbedonebymeansofsingleordoubleinterlock(maleandfemaleedges),invisibleonbottomface.

Jointsalongthechamferededgesonbothsidesofthepanelwillbedoublesealedwithsiliconecompound.

Alluppersealsaretobeprotectedbygalvanisedmetalsealcovers.

Asuitablecornerpiecewillcoveralljointsbetweenhorizontalandverticalpanels.Itshallconsistofaquartercircleshapedepoxyprotectedaluminiumsheeting,withsealingbymeansofsiliconecompoundbetweenthesheetmetalandthepanel.SuitablefinishingpiecesaretobeincludedoppositethePVCrisingplinthandatthemeetingpointsoftheverticalandhorizontalcorners.

Remark:Alltheverticalandhorizontalcornerpiecesshallbeinstalledwithoutintermediatecutouts.

K=0.43W/°C.m2(classifiedandnoclassified)

Materials

Thepanelsshallconsistoftwosmoothsidesmadeofgalvanisedsteelsheet,pre-enamelledfinishwithamineralwoolinsulatingcore.

Hot-dipgalvanised(mini:class2,Z225).

Pre-enamellingistobehouseholdgrade:5+20microns,colourtobeselectedbyfromthemanufacturer’sstandardrange.

Steelsheetthickness:6/10e(0,6mm)minimum.

Non-flbleand bustible-firerated15minutesminimumatleast(withtestreport).Theceilingoftheevacuationcorridorshouldreachthefire ratingofonehour.

Themetalfacingofthepanelshallbecoveredbyanadhesivetransparentprotectivefilmwhichwillberemovedonlyaftererectionandbeforesealing.

Joinery

Windows

Theframesaretobeflushonbothsideswiththefollowingcharacteristics:

Punch-outsandfittedglassaretobecarriedoutinthefactory.

Airistobeextractedfrombetweentheglasspanelsandtheareaistobedehydratedandsealed.

Windowsaretobedouble-glazedwithtoughenedglassbothsidesflushandminimumthicknessofeachglasspanel:6mm.

Siliconcompoundwillbeusedforperipheralsealingoftheframe.

Doors

Bothsidesofdoorsaretobeflushandmeetthefollowingminimumcharacteristics:

Frame:

Thesolidblockcasingshallbeingalvanisedsteel,pre-enamelledfinishedandsetintothepartition.

Leaf

Thepanelshallconsistoftwosmoothfacesingalvanisedsteel(minimumthickness75/100ths)andofaninsulatingcore,thickness60mm.Pre-enamelledfinished.

Thesubcontractorshallsupplyadjustablelouver(“clonet”)inthelowersectionforair-tightness.

Enamelling

ThecolourwillbespecifiedbySanofiPasteur.

Ironmongery

Rein mentoftheleafbystainlesssteelhinges(thetywilldependuponthedoorweightanddimensions).

Fortwo-leafeddoors,thesemi-fixeddoorwillbefastenedwithonecontrolbutton.Thefloorlevellatchisincludedinthescopeofwork.

Thenylondoorstopssetintotheflooringormountedonthepartitions,colourshallmatchwithotherfittings.

Thefittingswillconsistoflockingbarsanddouble-lockingknopsmadeofrein dnylonwithasteelcoreandreturnspringsetinthelockingbars.

Colourwillbeselectedby ,fromthemanufacturer’sstandardrange.

Sealing

Sealsaroundtheperipheryoftheleaf(3sides)and“Clonet”onthefeet,

Eyepiece

Rectangularshapedeyepiecetypeglasswithflushdoubletoughenedglass,glued,dittofortheglassframes,sizewillbestatedinthespecification.

Doorcasesandframes

Thedoorcoatinginthebasewillhavethesamecharacteristicsasthoseofthepartitions.Sealingwillbeensuredbytubulargasketssetintotheframeandbyaseal.Theframesaretobeequippedwithabrand,lockpin,fittedbytherandcontrolledbyabadge-reader;connectionwillbeunderresponsibilityoftheelectricalr.

Whenorderingthesignallights,itipectedthataproximitydetectorwillbemountedonateinthecrosspieceofthedoor.Ametalflatpiecewillbegluedabovethedoorframe.Thecontractorforthisworkwillhavetoallowforthepassageoftheproximitydetectorinthecrosspieceandallowspaceforthejunctionboxandfurtherspaceabovethedoortocompensatefortethicknessandenclosureofthisspaceinthepartition.Oneothersystemcouldbeinstalled.

Whitecolouredbuildinghardwareistobeused.Safetyorlaminatedglassistobeusedinthebullseyewindows,thesewillbemountedinthedoorfacingandsiliconesealed.

Closedoor

Allthedoorsofthisprojectmusthaveoneautomaticclosedoor.

Airtightdoor

ATDstructure.

Thereareair-filledbarsinthedoorframetoguaranteethesealingofthedoor.

Thereisavisionportonthedoor.

Thedoorcanbeinterlockedtoensurenomorethanonedoorisopenedatthesametime.

Inanemergency,thedoorshouldbecutoffandcanbeopened.

Emergencydoor

Theemergencydoorshouldmeettherequirementsof"buildingglassapplicationtechnologyspecificationJGJ113-2009".

Theglassshouldusesafeglass.

Thereshouldbeobvioussignsontheemergencydoor,topreventthestaffhittheglassbymistake.

Betweenthedoorframeandwallshouldbesealedtight,thegapusesfoodgradesiliconetoseal.

Emergencydoorshouldsetupsafetyhammer.

Floor

Afterpolishingconcretefloors,thewholecleanroomssurfaceshallbecoveredwithaPVCflooringwhichwillmeetthefollowingcharacteristics:

Flooringinwidthselementstype

Mechanicalperformancesgrading:PVCmaterialshallresisttocirculationofmanualtrolleys.

Maxpointload:200daN

Maxbearingpressure:30daN/cm²

Soundproofing:>3dB

Thickness:2mm

Layingbygluingwithacrylicemulsion

Bacteriologicalandfungistatictreatment(inManufacturer’sfactory)

CarryingoutaccordingtotheManufacturerspecifications

againstmechanicalshocks,loads(trolleywithnylonwheels),punching,scratchesandwear

JointtreatmentbyPVCcordheatweldedandofcolourmatchedwiththeflooring.

Colourchosenby inther’srange

Workswillalsoinclude:

allthenecessaryjointsaroundholesandsealingsiftheyarecarriedoutbeforeorduringthelayingofthefloorings,

allthenecessaryjointsoncleanroompartitions,including:PVClayingoncurvedplinth,perfectlylevelledandflushwiththepartitionsexternalleavesandfinishedwithsiliconjoint.

allthesurfaceshallbecovedbyPVCsheet.

Miscellaneous

Siliconcompound

Themasticistobecategory1asperqualification,forapplicationwithoutprimeronglass,aluminiumandcoatings.

Themasticwillbeantifungalandbactericidalwithexcellentageing properties,particularlytoUV(noyellowing)andwillwithstandconventionalcleaningproductsaswellasformaldehydegas,ammoniaandH²O².

Themasticistobetranslucent,whiteorgreydependinguponthezonestobetreated.Innocasehisstripwidthwillexceed10mm.

Pre-cutinpartitions

Mostcuttingwillbecarriedoutintheworkshopinaccordancewiththeconstructiondrawingstobedbyothersubcontractorsforthetechnicallotsaftercontractorapproval.

Reservationshallcover:

Air-conditioningextractorgrids,tobeconfirmedbytheair-conditioningcontractor,

Fluidpipecrossings,

Smallelectricappliance(wallsockets,switches,signallights)

Spaceforadjustingstructurealreadyinsitu

Forequipmentpenetrations,

Forenvironmentcontrolmeasuringdevices.

Thecuttingedgeswillhavetobeprotectedbyagalvanizedsheetwhichwillbefoldedoverthesurfaceandunderthepanelfaceandwillbeadjustedtotheequipmentinordertobeinvisible

Nobareedgeswillbeaccepted.

Pre-cutinceilings

Mostcuttingwillbecarriedoutintheworkshopinaccordancewiththeconstructiondrawingstobedbytheothersubcontractorsaftercontractorapproval.

Penetrationshallcover:

laminarflowequipment,

lightingequipment,forventilatorgrids,(blowerandextractor)forprocessequipment,

LaminarAirFlowinthewraproom

environmentcontrolmeasuringdevices,

Firedetectorsandsprinkler

Pipepenetrationsandsuspendedequipment

Motionsensor

Theedgesresultingfromcuttingaretobeshieldedbyenamelledsheetingthesizeofwhichwillfitwiththeequipmentandwillbeinvisible,

Sharpedgeswillnotbeaccepted.

Peripheralsealingofthisequipmentisincludedinthescopeofworkandistobeimplementedwithsiliconestriponthegridsandwithadjustedsteelsheetssealedwithsiliconescriponthecableandpiperuns.

Reinmentshallbesupply,ifpenetrationislocatedonabracingdevice.

Hepafilterbox

Thefilterboxincorporatedintheceiling,madeofgalvanizedsteelpre-enamelledfinished,musthaveone umoverflushingof2mmmustbefixedabovetheceiling,andsealedwithsiliconcompoundattheperipheralbetweenboxandceiling.

Light

Thelightingequipmentincorporatedandfixedontheceiling,madeofgalvanizedsteelpre-enamelledfinished,musthaveone umoverflushingof2mm,andwithpossibilitytoremovethelampsandballastfromaboveoftheceiling,andsealedwithsiliconcompoundattheperipheralbetweenboxandceiling.

Thelightingequipmentshallprovide350luxat1mroomthefloorallproductionroomand300luxat1mfromthefloorforthestorage,coldroomandchangeroom.

Electricalequipment

Theelectricalequipmentswitchesasocket;pushbuttonect…incorporateandfixedonthepartitionpanelmusthaveone umoverflushingof2mmifpossible.

Trans-wallorPassthru

Thetrans-wallincorporateandfixedonthepartitionpanelmadeofstainlesssteelshalleasiercleaningandopeningshallbesealedwithfireproofsiliconcompoundattheperipheralbetweenboxandceiling.

Fireproofpenetrationmaterials:anywallpenetrations,suchasairductsandcabletrays,shouldbesealedwithFMapprovedfirestopmaterials.

Locatedaccordingtolayoutdrawing.

Protectionduringsiteworkphase

Safetyprotectiononceilings

Assoonasaholehasbeenmadeintheceilingthesubcontractorshallsupplyandfitashutterorplugconsistingofawoodpanelboard,minimumthickness30-mmforaholeofsize:

0.60mifnormalpanelsareused,

0.75mifCTB-Hpanelsareused.

Thesizeofthesealingpanelswillbeatleastequaltothepenetrationsection+0.10m(e.g.holes0.50x0.50=0.60x0.60panel)

Thesepanelsshallbelockedwithsidestop-piecestoensurethattheyareheldincewithnoriskofslippage.

Protectionofceilingpanels

Supplyandinstallationoftemporaryclipboard

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论