aShanghaiElectronicsCo.

Page1of10

*

withoriginalsignaturesarchivedattestlab.

Thetestresultsareonlyvalidfortheequipmenttested.Responsibilityforcomponent-specifictestequipmentislefttothe

.This

issare

.

Itscontentsarenottobeexploited,passedonordisclosed–notinextractseither–tothirdpartieswithoutourexpresspermission.aShanghaiElectronicsCo.,.,411JianYeRoad,PudongNewArea,Shanghai201201,P.R.

.

(2013-08)

TEST REPORT

VacuumPumpSGMEpsilon&258

8TG312.150-29/32

Validationtest(C-sample)SequenceB

PDMNo.:

10001092053_003_01

Date: 16.Dec.2013

Createdby:

GaoYu

Org.-Unit:

HSE-T-TLC

Sign.*:

Reviewedby

HarryHe

Org.-Unit:

HSE-T-TLC

Sign.*:

Releasedby:

DingChunyan

Org.-Unit:

HSE-T-TLC

Sign.*:

TEST

REPORT

Org.-Unit: HSE-T-TLC

Createdby:

*

GaoYu

Date:

16.Dec.2013

Page

PAGE

10

of

NUMPAGES

10

withoriginalsignaturesarchivedattestlab.

Thetestresultsareonlyvalidfortheequipmenttested.Responsibilityforcomponent-specifictestequipmentislefttothe

.This

issare

.

Itscontentsarenottobeexploited,passedonordisclosed–notinextractseither–tothirdpartieswithoutourexpresspermission.aShanghaiElectronicsCo.,.,411JianYeRoad,PudongNewArea,Shanghai201201,P.R.

.

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

DistributionList: toMs.YanLi

Mr.HarryHe

Ms.DingChunyan

HSE-T-PCIHSE-T-TLHSE-T-TL

ccMs.ChrisZhuangMr.MalteWis ann

HSE-T-QD

HSE-T-TL

Mr.SebastianGajdaE-C-D-T3

Test: SequenceB

Electro-patickeyvaluesatRT

Temperaturestorage

Noiseoutputrequirementsatcoldstart

Electro-patickeyvaluesat-40°C/+100°C

Thermaloverload +100°C

Thermaloverload +120°C

Changingtemperatures

Thermalshock

Surfacetoinfluencesfromenginecompartment

ResultSummaryIncl.TestEvaluation:

ThevalidationtestsequenceBwaspassed.

Orderedby: Ms.YanLi,HSE-T-PCI

Reference: Testinstruction(General):Testinstruction(Variant):Testn:

10000335379dated22.Feb.2012

10000498319dated22.Feb.2012

10000896546_001_01dated30.Aug.2012

TestObject: 5pcs.PumpUP288TG174.979-34

SampleNo.:B01~05,MudocNo.:474374-474378

TypeofSample: C-sample

ManufacturingDate:CW02/2013

TestReason: Validationtest(C-sample)

TestPeriod: 20.Jan.2013~06.Sep.2013

TestRequirement/EvaluationCriterion

Seerespectivesection

(2013-08)

TestParameter: Seerespectivesection.

(2013-08)

Meas.-/Testequipm.:

Vacuumpumpfunctiontester

HSE-T-TL

Testequipmentno.:

E

Climatechamber

HSE-T-TL

Testequipmentno.:

E

Powerboxdurabilitytester

HSE-T-TL

Testequipmentno.:

E

Thermalshockchamber

DAVIS

Testequipmentno.:--

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

Result: ThevalidationtestsequenceBwaspassed.Detailsarelistedintheirrespectivesections.

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

Electro-p atickeyvaluesatRT

TestReference: Testinstruction(General):10000335379Point4.1.1

Testinstruction(Variant): 10000498319Point4.1

TestRequirement: Thetechnicalrequirementmustmeetthefunctionrequirementintestinstruction.

TestParameter: Testvoltage:

Testvolume:Testtemperature:Testduration:

12V±0.1V

3.2L

23°C±5°C

40s

(2013-08)

TestResult: Thetestwaspassed.

Allperformancevaluesmetthespecification.(Seetable1)

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

8TG174.979-34

Ratedvalue

Actualvalue

Evaluation

Testpoint

Unit

Condition

Min

Max

Min

Max

Avg.

MeancurrentbetweentheswitchingthresholdsP1-P2

[A]

Newstate

-

10.0

7.3

8.1

7.7

o.k.

Aftertemperaturestorage

-

10.0

7.3

7.8

7.7

o.k.

Afteroverload +100°C

-

10.0

7.5

8.0

7.8

o.k.

Afteroverload +120°C

-

10.0

7.7

8.3

7.9

o.k.

Afterchangingtemperatures

-

10.0

7.1

7.9

7.4

o.k.

Afterthermalshock

-

10.0

7.0

8.0

7.5

o.k.

Aftersurface

-

10.0

7.1

8.0

7.5

o.k.

umcurrentfort<100ms

[A]

Newstate

-

60.0

43.2

45.8

44.9

o.k.

Aftertemperaturestorage

-

60.0

38.5

40.6

39.4

o.k.

Afteroverload+100°C

-

60.0

43.1

46.1

44.4

o.k.

Afteroverload+120°C

-

60.0

41.7

43.5

42.3

o.k.

Afterchangingtemperatures

-

60.0

42.6

46.9

45.4

o.k.

Afterthermalshock

-

60.0

40.2

46.3

43.0

o.k.

Aftersurface

-

60.0

40.1

42.3

40.8

o.k.

umcurrentfor100ms≤t<400ms

[A]

Newstate

-

16.0

8.6

9.4

9.1

o.k.

Aftertemperaturestorage

-

16.0

8.7

9.4

8.9

o.k.

Afteroverload +100°C

-

16.0

8.3

9.2

8.9

o.k.

Afteroverload +120°C

-

16.0

8.3

9.2

8.8

o.k.

Afterchangingtemperatures

-

16.0

8.2

9.4

8.9

o.k.

Afterthermalshock

-

16.0

7.5

9.9

8.4

o.k.

Aftersurface

-

16.0

7.8

9.4

8.6

o.k.

umcurrentfort≥400ms

[A]

Newstate

-

11.0

8.5

9.5

9.0

o.k.

Aftertemperaturestorage

-

11.0

8.7

10.0

9.2

o.k.

Afteroverload+100°C

-

11.0

8.6

9.2

9.0

o.k.

Afteroverload+120°C

-

11.0

8.8

9.3

9.1

o.k.

Afterchangingtemperatures

-

11.0

8.4

9.3

8.9

o.k.

Afterthermalshock

-

11.0

7.8

10.3

9.4

o.k.

Aftersurface

-

11.0

8.6

9.7

9.1

o.k.

Lowpressurefromtherespectiveambientpressureaf nevacuationtimeof

≤40s

[%]

Newstate

86.0

100.0

90.7

92.3

91.6

o.k.

Aftertemperaturestorage

86.0

100.0

90.5

92.4

91.5

o.k.

Afteroverload+100°C

86.0

100.0

90.6

92.6

91.7

o.k.

Afteroverload+120°C

86.0

100.0

90.3

92.7

91.6

o.k.

Afterchangingtemperatures

86.0

100.0

91.2

93.0

92.2

o.k.

Afterthermalshock

86.0

100.0

91.1

93.3

92.4

o.k.

Aftersurface

86.0

100.0

87.4

89.0

88.3

o.k.

PressureGenerationtime50%fromambientpressure

[s]

Newstate

-

5.5

4.1

4.1

4.1

o.k.

Aftertemperaturestorage

-

5.5

4.1

4.6

4.2

o.k.

Afteroverload+100°C

-

5.5

4.0

4.1

4.1

o.k.

Afteroverload +120°C

-

5.5

4.0

4.3

4.1

o.k.

Afterchangingtemperatures

-

5.5

3.9

4.1

4.0

o.k.

Afterthermalshock

-

5.5

4.1

4.4

4.2

o.k.

Aftersurface

-

5.5

4.4

4.7

4.5

o.k.

PressureGenerationtime30%fromambientpressure

[s]

Newstate

-

12.0

8.0

8.1

8.1

o.k.

Aftertemperaturestorage

-

12.0

8.0

9.1

8.4

o.k.

Afteroverload +100°C

-

12.0

7.8

8.2

8.0

o.k.

Afteroverload +120°C

-

12.0

7.9

8.5

8.1

o.k.

Afterchangingtemperatures

-

12.0

7.5

8.1

7.8

o.k.

Afterthermalshock

-

12.0

7.7

8.6

8.1

o.k.

Aftersurface

-

12.0

8.6

9.4

9.0

o.k.

(2013-08)

Table1:Electro-p atickeyvaluesatRT

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

Temperaturestorage

TestReference: Testinstruction(General):10000335379Point5.2.1

TestRequirement: Thetechnicalrequirementmustmeetthefunctionrequirementintestinstruction.

TestParameter: Testtemperature:

Testduration:

120°C±2°C/-40°C±2°C

Eachtemperaturefor24h,keethesamplesatroomtemperature1hbetweeneverytime.

TestResult: Thetestwaspassed.

Allperformancevaluesmetthespecification.(Seetable1)

Noiseoutputrequirementatcoldstart

TestReference: Testinstruction(General):10000335379Point5.7.2

TestRequirement: Duringthe1stmotorstart-upa“bearingscreech”ispermitted.

TestParameter: Storagecondition:

Testvoltage:

4hstorageat-40°C±2°C

13.5V±0.1V

(2013-08)

TestResult: Thetestwaspassed.

Afterthestartoftheelectricmotorofthepumpshadnointrusivefeelingofanoperatingnoiselevel.

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

Electro-p atickeyvaluesat-40°C/+100°C

TestReference: Testinstruction(General):10000335379Point4.2

Testinstruction(Variant): 10000498319Point4.1

TestRequirement: Thetechnicalrequirementmustmeetthefunctionrequirementintestinstruction.

TestParameter: Storagetemperature:

Storageduration:Storageoperatingmode:Testvoltage:

-40°C/+100°C

2h

devicenotoperating12V±0.1V

(2013-08)

TestResult: Thetestwaspassed.

Allmeasuringvaluesmetthespecification(seetable2).

8TG174.979-34

Ratedvalue

Actualvalue

Evaluation

Testpoint

Unit

Condition

Min

Max

Min

Max

Avg.

MeancurrentbetweentheswitchingthresholdsP1-P2

[A]

At-40°C

-

11.0

5.6

6.6

6.0

o.k.

At+100°C

-

11.0

7.7

8.2

8.0

o.k.

umcurrentfort<100ms

[A]

At-40°C

-

60.0

49.9

51.3

50.5

o.k.

At+100°C

-

60.0

37.0

38.7

37.9

o.k.

umcurrentfor100ms≤t<400ms

[A]

At-40°C

-

16.0

7.6

8.9

8.2

o.k.

At+100°C

-

16.0

8.3

9.8

9.0

o.k.

umcurrentfort≥400ms

[A]

At-40°C

-

12.0

7.5

9.1

8.0

o.k.

At+100°C

-

12.0

8.5

9.6

9.0

o.k.

Lowpressurefromtherespectiveambientpressureaf nevacuationtimeof≤40s

[%]

At-40°C

83.0

100.0

91.3

93.2

92.4

o.k.

At+100°C

83.0

100.0

89.3

91.8

90.7

o.k.

PressureGenerationtime50%fromambientpressure

[s]

At-40°C

-

6.0

3.7

4.2

3.8

o.k.

At+100°C

-

6.0

3.9

4.2

4.0

o.k.

PressureGenerationtime30%fromambientpressure

[s]

At-40°C

-

13.0

7.0

8.3

7.4

o.k.

At+100°C

-

13.0

7.9

8.3

8.1

o.k.

Table2:Electro-p atickeyvaluesat-40°C/+100°C

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

Thermaloverload +100°C

TestReference: Testinstruction(General):10000335379Point5.2.4

TestRequirement: Thetechnicalrequirementmustmeetthefunctionrequirementintestinstruction.

TestParameter: Testvoltage:

Pressurerange:Temperature:Totaltesttime:

12.5V±0.1V

500mbar(on)…300mbar(off)100°C±2°C

20minat10%on-time

TestResult: Thetestwaspassed.

Allmeasuringvaluesmetthespecificationafterthistest(seetable1).

Thermaloverload +120°C

TestReference: Testinstruction(General):10000335379Point5.2.5

TestRequirement: Thetechnicalrequirementmustmeetthefunctionrequirementintestinstruction.

TestParameter: Testvoltage:

Pressurerange:Temperature:Totaltesttime:

14V±0.1V

800mbar(on)…250mbar(off)100°C±2°C

20minat10%on-time

(2013-08)

TestResult: Thetestwaspassed.

Allmeasuringvaluesmetthespecificationafterthistest(seetable1).

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

Changingtemperatures

TestReference: Testinstruction(General):10000335379Point5.2.3

TestRequirement: Thetechnicalrequirementmustmeetthefunctionrequirementintestinstruction.

TestParameter: Testvoltage:

Pressurerange:

Cycletimeperloadprocess:Pumpoperation:

Testprofile:

12.5V±0.1V

500mbar(on)…300mbar(off)100s

on–time=approx.5%

TestResult: Thetestwaspassed.

(2013-08)

Allmeasuringvaluesmetthespecification(seetable1).

Project:

VacuumPump

Customer:

SGMEpsilon&258

PDMNo.:

10001092053_003_01

Customer-Part-No.:

--

a-Part-No.:

8TG312.150-29/32

Thermalshock

TestReference: Testinstruction(general):10000543034point5.2.2

TestRequirement: Thetechnicalrequiremen

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论