版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
GB/TXXXXX.9—XXXX/IEC61010-2-031测量、控制和实验室用电气设备的安全要求第9部分:能测量电网电源电压的家用和专业用手持万用表和其他仪表的特殊要求本文件规定了能测量电网电源电压的家用和专aa)IEC61557(所有部分)交流1000V和直流1500V以下的低压配电系统的电气安全防护措施的);againstvoltagedisturbancesandelectromagneticdistGB/TXXXXX.9—XXXX/IEC61010-2-032探头组件的安全要求(Safetyrequirementsforelectricalequipmentformeasurement,controlelectricalmeasurementanIEC61180-1低压设备的高压试验技术第1部分:定义、试验和程序要求(High-voltagetestagainstvoltagedisturbancesandelectromagneticdist手持式和手动探头组件的安全要求(Safetyrequirementsforelectricalequipmentformeasurement,control,andlaboratoryuse—Part031:Safethand-manipulatedprobeassembliesforelectricaltestandmeasurementechniquesforlow-voltageequipment—Definitions,testandproced路的特殊要求(Safetyrequirementsforelectricalequipmentformeasurlaboratoryuse—Part2-030:SpecialrequirementsfortestingandIEC61010-2-032:2023测量、控制和实验室电气设备的安全要求第2-030部分:用手持和手操电流传感器的特殊要求(Safetyrequirementsforelectricalequipmentforheldandhand-manipulatedcurrentsensorsforelGB/TXXXXX.9—XXXX/IEC61010-2-033测量类别measurementcatec)用交流和直流供电的手持万用表应连接到一个交流或直流电源;d)由单相电源供电的手持万用表交流电应以正常极性和反向极性连接;4.3.2.6输入和输出电压4.3.2.6输入和输出电压或电流4.4.2.101浪涌保护装置5.1.2标识GB/TXXXXX.9—XXXX/IEC61010-2-034注101:一些国家法规可以要求标志显5.1.5端子、连接件和操作装置5.1.5.1通则5.1.5.2端子5.1.5.101测量电路端子应按适用的情况标记预定一起使用的测量电路端子对或端子组的额定电压或者额定电流。定相线-中线交流有效值或直流电压。用这两种类型,并且只有这两种类型的测量类别及其对地额定电压来标记端子是允许的。不允许标记测量类别Ⅱ。其他测量电路端子应标记额定对地电压注:测量类别的电气间隙和固体绝缘基于被测电网电源的标称交流有效值相如果有识别测量电路端子的方法,仅连接到其他设当手持万用表在正常使用时警告标志应清晰可辨。如果一个警告适用于手持万用表的一个特定部b)在材料上模注、模压或蚀刻的符号或文字的高度应至少为GB/TXXXXX.9—XXXX/IEC61010-2-035如果为了保持手持万用表提供的防护而需要责任者或操作人员去查阅文件,则手持万用表应标有aa)文件应说明,电网电源测量使用的如果手持万用表能够测量同一测量电路的多个测量类别额定值,文件应明确说明手持万用表适用用下面的内容、符合性声明和图4代替原来的内容、符可触及零部件在单一故障条件下应避免变为危险带电。应提供a)或b)中的一种作为初级防护措施(见6.4)。或者,应采用c)或d)中的一通过目视检查,如果适用,通过6.5.3、6.5.GB/TXXXXX.9—XXXX/IEC61010-2-036双双重绝缘危险带电零部件6.4.1a)外壳或挡板绝缘加强绝缘6.4.1a)外壳或挡板绝缘加强绝缘6.4.1c)6.5.和6.5.1b)6.5.1b)限流或限压装置6.4.基本绝缘6.56.5.可触及零部件当确定仅连接到符合GB/T42125.7—XXXX的手持万用表或符未装配位置、部分装配或装配位置的测量电路端子的要求分别在6.6.101.2、6.6.101.3和当额定电压施加到手持万用表的任何其他端子时,以下要求适用于处于未装配位置的测量电路端未装配测量电路端子的可触及零部件与危险带电零部件应通过保护阻抗或满足a)和b)要求的电GB/TXXXXX.9—XXXX/IEC61010-2-037施加在端子导电零部件的最大电压V电气间隙交流有效值mm直流mm对于最大电压超过30V交流有效值或60V直流,不超过600V,电气间隙为0.600V以上允许线性内插法。i)检查和测量从最不利位置接触端子外部零部件的试验b)爬电距离值应至少为6.6.101通过检查和测量从最不利位置接触端子外部零部件的试验指的最接近位置的爬电距离来检验是否6.6.101.3测量电路端子处于部分处于部分装配位置的测量电路端子零部件的可触及零部件应以基本绝缘方式与危险带电零部件绝6.6.101.4处于装配位置的测量GB/TXXXXX.9—XXXX/IEC61010-2-038在其他测量电路的处于装配位置的端子可触及零部件应通过双重绝缘或加强绝缘与危险带电零部专用测量电路端子的元器件、传感器和装置不应是可触及且危险行连接。如果适用,当以下的电压施加到测量电路端子之间时,进行6.3的测量以确定不超过6.3.1和a)任何额定电网电源频率下的最大额定交流电压;c)最大额定测量频率下的最大额定交流电压。对于不由电网电源或测量电路供电的手持万用表,材料组别Ⅰ的爬电距离适用值允许适用于所有1)最大可能瞬态过电压由供电电源或手持万用表内部限制在低于电网电源电路假设等级的3)工作电压是多个电路的电压之和,或者是混注1:与电网电源类型和标称电压有关的相线-中线GB/TXXXXX.9—XXXX/IEC61010-2-039对于测量未装配端子的电气间隙[见6.6.101.22)a)ii)],使用试验指在最不利位置以最接近的防止闪络的最小距离。有关这些最小距离的指南见表预定用于电网电源电压测量的测量电路端子额定电压至少为交流有效值相线-中线电压300V,或9.101测量电路的保护GB/TXXXXX.9—XXXX/IEC61010-2-039.101.1概述9.101.2输入和量程不匹配的防护9.101.2.1概述在正常条件及在可合理预见的误用时,当测量端子的最大额定电压或电流施加在端子或任何兼容端子上,在任意功能和量程设置组合的情况下,不应导显然不属于类似类型且探头组件或附件的连接器不固定的端子不需要进行试验,且仅可通过使用手持万用表应提供针对这些危险的保护。应使用以下a)或b)中的技术a)使用经过认证的过电流保护装置,在危险发生前中断短路电流(见b)使用未经认证的限流装置、阻抗或两者的组合,以防止危险发生(见9.101.29.101.2.2由经认证的过流保护装置进行防护如果过流保护装置经认可的测试机构认证并且满足以下a)~c)中的所有要求,则认为a)过电流保护装置的交流和直流额定电压至少应分别与设备上任何测量电路端子的最大交流和b)过流保护装置的额定时间-电流特性(速度)应确保额定输入电压、端子和量程选择的任何可c)过流保护装置的交流和直流额定分断9.101.2.3用未经认证的电流限制装置或阻抗进行防护用于限流的装置应能够安全地承受、耗散或中断在正常条件下以及在可合理预见的误用情况下应GB/TXXXXX.9—XXXX/IEC61010-2-031)额定电压为正常状态下或合理可预见误用事件期间可能出现的最大电压;2)如果是电阻器,额定值为正常状态下或合理可散的两倍;b)元器件的组合应:1)承受正常条件下或合理可预见的误用可能的交流和直流短路电流计算按照任何端子的最高额定电压除以电流限制测对任何端子来说,将与最大额定电压相同的电压施加在测量电路端子两端1min。试验电压源应能够按适用的情况提供至少是可能的交流或直流短路电流。如果功能或量程控制件对输入电路的电特性注2:该试验可能极其危险。可以使用爆炸防护板或其他措施来保护9.101.2.4用于试验的试验引线制造商没有指定试验引线,试验应使用符合下列a)~e)规范的试验引线按照这些规格制造的试验引线的直流电阻大约为每根15mΩ,或每对30mΩ。为了计算9.101.2.2当6.8.3的试验程序应用于手持万用表时,试验引线可以是未经更换的随试验9.101.3电网电源过电压防护GB/TXXXXX.9—XXXX/IEC61010-2-03额定测量类别的电压测量电路在电网电源相反极性的导电零部件间,包括用于限当电路在正常使用条件下工作时,脉冲电压与电网电源电压结合施加在每对额定用于电源电压测按照IEC61000-4-5:2014,6.2,脉冲电压测试。发生器产生1.2/50µs的开路用于试验的电网电源电压是被测电网电源的最大额定相线-中线电压。对于测量额定电压大于相线-中线交流400V或直流400V的电网电源电压,试验可以使用电压至少为交流400V或直流400V的电网被测标称交流有效值相线-中线电压VV>150≤300>300≤600>600≤1000>1000≤1500>1500≤2000>2000≤3000不超过1000V的值来自IEC60664-1:2超过1000V的值来自IECTS62993:2017GB/T42125.1—XXXX的第10章GB/TXXXXX.9—XXXX/IEC61010-2-03GB/T42125.1—XXXX的第11章GB/T42125.1—XXXX的第12章GB/T42125.1—XXXX的第13章GB/T42125.9—XXXX范围内的探头组件和附件,以及IEC61010-2-032:2023范围内的电流传感器随手持万用表提供的一组试验引线的额定值至少应符合IEC61010-031:2022的最GB/TXXXXX.9—XXXX/IEC61010-2-03手持万用表应提供在测量电路正常使用和可合理预见的误用情况下的危险防护措施,规定a)~c)手持万用表与预定用于手持万用表的其他设备或附件之间的任何互连不应引起危险,即使文件或标志禁止在手持万用表用于测量目的时进行互连(见对带有预定连接到没有内部保护的电流互感器的电流测量电路的设备应有足够的防护表通断最大额定电流6000次,来检验是否合格。试验当手持万用表用于测量电网电源电压时并且在可合理预见的误用情况下,读取电压值不会产生危在试验期间,施加于端子的交流有效值电压频率为50Hz或6GB/TXXXXX.9—XXXX/IEC61010-2-03连接到电池连接器的直流电源的供电电压从电池最大电压降低到零不超过20mV/s。在考手持万用表应能够承受永久过电压,并持续给出不超过最大额定电压的任何危险2)测量一个等于受试端子额定电压上GB/TXXXXX.9—XXXX/IEC61010-2-03假定接地二次电路的最大瞬态过电压等级比具有相同过电压类别或测量类别的一次电路的或K.3涵盖的这些电路具有以下a)~f)中的一个或多个特性:b)最大可能瞬态过电压大于表K.1d)工作电压是多个电路的电压之和,或者是混合电压;e)工作电压包括重复峰值电压,其可包括周期性非正弦波形或具有某种规律的非周期波通过目视检查和测量,或者通过6.8.3.1的脉冲电压试验,使用表K.16要求的电气间隙适用的GB/TXXXXX.9—XXXX/IEC61010-2-03表K.15K.3.2计算的电气间隙值最大电压UmV电气间隙最大电压UmV电气间隙D1mmD2mmD1mmD2mm14.1~2660.0100.01040003.003.802830.0100.01045303.534.803300.0100.01056604.997.153540.0120.01360005.507.904530.0300.03070706.849.555000.0400.04080008.0011.05660.0530.05389109.3712.97070.0810.0971130013.017.78000.100.131410016.823.28910.120.191770021.829.911300.220.362260029.239.214100.430.662830037.651.315000.500.763540050.866.917700.771.044530068.089.222601.261.555660085.025001.501.807070028301.832.208910035402.543.16100000215允许线性插值。要求的电气mm峰值脉冲1.2/50µsV交流有效值50/60HzV交流峰值50/60Hz或直流V要求的电气mm峰值脉冲1.2/50µsV交流有效值50/60HzV交流峰值50/60Hz或直流V0.01033023033016.5140007600107000.02544031044017.0143007800110000.04052037052017.514700800011300GB/TXXXXX.9—XXXX/IEC61010-2-030.06360042060018.0150008200116000.180650070019.0158008600121000.21140620880164009000127000.3131071010101990010800153000.515508401200233001260017900195010601500265001440020400244013301880402970016200229002.0310016902400453290017900253002.53600196027703600019600277003.04070221031303900021200300003.54510245034704200022900323004.04930268037904500024500346004.55330290041004790026100369005.05720311044005090027700391005.5610033204690805370029200413006.0650035204970855661030800435006.5680037105250905940032300457007.0720039005510956220033800479007.57500408057806500035400500008.07800430060307050038400542008.58200440063007600041300584009.08500460065008130044200626009.588004800680086600471006670010.0910049507000919005000070700GB/TXXXXX.9—XXXX/IEC61010-2-0310.595005200730097100528007470011.0990054007600102300556007870011.51030056007900107400584008260012.01060058008200112500612008650012.51100060008500200117500639009040013.01140062008800210122500666009420013.51180064009000220127500693009800014.012100660093002301325007200010200014.512500680096002401373007470010600015.012900700099002501422007730010940015.5132007200102002641490008110011500016.013600740010500允许线性插值。BID是基本绝缘的电气间隙。BIUm=Uw+Ut=(3500+4500)V=800Uw/Um=3500/8000=0.44将K.4现有的标题改为以下标题:GB/TXXXXX.9—XXXX/IEC61010-2-03测量电路用于测量电网电源时,瞬态应力可以根据进行测量时的安装位置来估计,当测量电路测量类别考虑了过电压类别、短路电流水平、试验或测量的位置以及建筑安装中包含的某些形式的能量限制或瞬态保护。当测量电路与电网电源相连接时,会有闪弧爆炸的风险。根据对于预定由被测电路供电的手持万用表,电网电源电路的电气间隙应按照额定测量类别的如果手持万用表额定用于在海拔2000m以上工作,其电气间隙应乘以GB/T42125.1中表对于基本绝缘、附加绝缘和加强绝缘,污染等级2的最小电气间隙是0.2mm被测电网电源的标称交流有效值相线-中线电压或直流电压V电气间隙mm基本绝缘或附加绝缘加强绝缘测量类别Ⅲ测量类别IV测量类别Ⅲ测量类别Ⅳ≤3003.05.56.010.4>300≤6005.58.010.4>600≤10008.014.015.023.9>1000≤150011.018.022.0>1500≤200018.022.044>2000≤300022.025.044通过目视检查和测量,或者通过6.8.3.1的脉冲电压试验,使用表K.16要求的电气间隙适用的GB/TXXXXX.9—XXXX/IEC61010-2-03),表K.102额定测量类别的测量电路中固体绝缘的介电强度脉冲试验电压被测电网电源的标称交流有效值相线-中线电压或直流V峰值脉冲试验电压V基本绝缘和附加绝缘加强绝缘测量类别Ⅲ测量类别Ⅳ测量类别Ⅲ测量类别Ⅳ≤3004000600064009600>300≤60060008000960012800>600≤10008000120001280019200>1000≤150010000150001790027100>1500≤200015000180002710032000>2000≤300018000200003200036000表K.103额定测量类别的测量电路中固体绝缘的介电强度交流试验电压被测电网电源的标称交流有效值相线-中线电压或直流V交流试验电压V基本绝缘和附加绝缘加强绝缘测量类别Ⅲ测量类别Ⅳ测量类别Ⅲ测量类别Ⅳ≤3002200330035005100>300≤6003300430051007000>600≤100043006600700010000>1000≤150054008200970015000GB/TXXXXX.9—XXXX/IEC61010-2-03>1500≤2000820097001500018000>2000≤30009700110001800020000K.101.4.2长时应力试验电压值计算基本绝缘和附加绝缘的试验电压值按以下公UN——被测量的电网电源的标称交流相线-中线电压或直流电压;A和B——如下确定的参数:N>1000V时,A=1.5且B=750V。注:不超过1000V的参数值源自IEC60364-4-44:2007,442.2.2,大于1000V的参数值源自IECTSK.101.4.3.1概述固体绝缘材料还应满足以下适用要求:如适用,按照K.101.4.3.2~K.K.101.4.3.2模制和模压零部件对于基本绝缘、附加绝缘和加强绝缘,位于K.101.4.3.3印制线路板的内部绝缘层对于基本绝缘、附加绝缘和加强绝缘,在位于相同两层之间的导体(见图K.2,L)应分开表K.104额定测量类别的测量电路用固体绝缘距离或厚度的最小值标称交流有效值相线-中线电压或直流电压V最小厚度amm最小距离L(见图K.1和图K.2)a,bmm≤3000.40.4>300≤6000.60.6GB/TXXXXX.9—XXXX/IEC61010-2-03>600印制线路板内部绝缘层的加强绝缘,对各个单独的层应具有足够c)绝缘至少由印制线路板材料的两个分离的层组成,组合层的介电强度值都会被材料制K.101.4.3.4薄膜绝缘对于基本绝缘、附加绝缘和加强绝缘,位于相同两层之间的导体(见图K.3,L)应至少间b)绝缘至少由薄膜材料的两个分离的层组成,任一层的介电强度值都会被材料制造商规c)绝缘至少由薄膜材料的三个独立层组成,任意两层都要通过试验来证明具有合适的介为了完成该试验,可以组装一个只有两层材料GB/TXXXXX.9—XXXX/IEC61010-2-03AA.1概述AA.2测量类别AA.2.1测量类别Ⅱ测量类别Ⅱ适用于在直接连接低压电网电源设施的使用端(插座和类似部位)的试验和测AA.2.2测量类别Ⅲ测量类别Ⅲ适用于连接到建筑物的低压电网电源设施的配电部分的试验和测量电路(见表对于是固定设施一部分的设备,设施中的熔断器或断路器可以认为提供了足够的对短路电AA.2.3测量类别Ⅳ测量类别Ⅳ适用于连接到低压电网电源设施的建筑物源端试验和测量电路(见表AA.1和图由于伴随这些高短路电流的高能量,在这些位置进行的测量是非常危险的。应该有足AA.2.4无额定测量类别的设备许多类型的试验和测量电路不预定直接连接到电网电源。其中一些测量电路是预定用于非常低的能量的应用中。但是其中的其他测量电路由于高短路电流或高开路电压也许会经受非常高的能量。对于这些电路没有定义标准瞬态级别。为了确定绝缘要求和短路电流要求,这些电GB/TXXXXX.9—XXXX/IEC61010-2-03表AA.1测量类别的特征测量类别短路电流(典型的)(kA)a建筑设施的位置Ⅱ连接到低压电网电源设施的插座和类似部位的Ⅲ建筑物的电网电源配电部分Ⅳ电网电源设施的源端处a环阻抗(装置阻抗)的值不考虑试验引线的电阻和GB/TXXXXX.9—XXXX/IEC61010-2-03本附录为设备制造商提供关于设备在特定环境下测量电气参数宜考虑的危险的指南。危险试验和测量电路在测量或试验期间承受工作电压和与它们连接的电路的瞬态应力。当测量行测量。制造商宜提供足够信息提醒操作人员防范电击危险,宜确保满足本部分和其他相关文件的设计要求(例如,见5.4和IEC61010-031中的电压闪弧是通过材料的蒸发和电离从电弧释放热能。闪爆是电弧释放的机械能、声能、热能和这可以导致电离空气的电弧。电离的空气是导电的,电流能够在导体附近连续流如果有足够的可利用能量,空气的离子化将连续传播,电流的流动将持续增加。结果类似于一个爆炸,能引起操作人员或者旁观者巨大的伤当测量电路用于测量带电电网电源时,存在闪弧的风险。测量类别(见附录AA)定义了可当有电流时,连接两个高能导体的任何导体(例如首饰)也许会变热。这会引起靠近导体电信网络中持续产生的电压和电流是低于被认为是危险带用于试验和测量电信网络的设备的制造商宜意识到来自“振铃”电压的危险和宜采取合适的步骤来减少危险。可能通过限制接触导体;在其他情况下,通过为操作人员提供足够的使用GB/TXXXXX.9—XXXX/IEC61010-2-03会发生危险。这样的突然事件能在电路的非故意断开时产生感性电压尖峰。这些电压尖峰可以是电路工作电压值的许多倍,能引起绝缘的失效或使操作人员受到电制造商宜向使用人员提供足够的使用说明,确保电流测量装置不与电感电路串连使用,或电池能对进行电池试验或者其相关电路试验的人员产生电击、爆炸和着火危险。示例电池端子短路引发的电击、爆炸或者在电池充电期间气体电弧点火引发的爆炸可能引BB.6在较高频率下的测量一些测量装置依靠感应连接到被测电路(见IEC61010-2-0的性能取决于被测信号的频率。如果测量装置用来测量的频率高于其设计频率,那么通过的电BB.7使用带功能接地端子的测量电路的测量示波器和光谱分析器是经常包含测量电路中功能接地端子的设备的例子。一个在测量电路中的可预见的误用的例子是操作人员可能会断开保护接地导体以至于功能接地端子的
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 柳州市三江侗族自治县2025-2026学年第二学期五年级语文第八单元测试卷(部编版含答案)
- 延安市子长县2025-2026学年第二学期二年级语文第八单元测试卷部编版含答案
- 宜昌市西陵区2025-2026学年第二学期五年级语文期末考试卷(部编版含答案)
- 曲靖市宣威市2025-2026学年第二学期四年级语文期末考试卷(部编版含答案)
- 印刷设备机械装调工岗前教育考核试卷含答案
- 锁零件制作工岗前工作技巧考核试卷含答案
- 工具钳工岗前离岗考核试卷含答案
- 裁剪工岗前活动策划考核试卷含答案
- 2026年智慧检察听证系统的功能实现路径
- 合肥市西市区2025-2026学年第二学期三年级语文第八单元测试卷(部编版含答案)
- 2026届新高考物理考前冲刺复习电磁感应中的单杆模型
- 2026国家药品监督管理局药品和医疗器械审评检查京津冀分中心、华中分中心、西南分中心第一批编外招聘122人笔试参考题库及答案解析
- (二模)东北三省三校2026年高三第二次模拟考试 语文试卷(含答案及解析)
- 2026年青岛金家岭金融聚集区管理委员会公开选聘工作人员考试参考题库及答案解析
- 河北省石家庄市2026届高三一模考试化学试卷(含答案)
- 工程计量监理实施细则
- 2025年工业废水处理AI工程师的污水处理厂智能控制案例
- VMware6培训教学课件
- 初中历史新课程标准解读
- 人员被困应急预案(设备内部、深基坑、罐体等)
- 自然特征与农业课件2025-2026学年人教版八年级地理下册
评论
0/150
提交评论