《HighVoltageEquipmentTesting》LoopResistanceTest主讲人:何发武(副教授)OperatingWorksheet:OperatingWorksheet:TableofContents01Followme02Workshop03Training01FollowmeFollowMeThedifferencebetweenloopresistanceandDCresistanceliesintheelectricalequipmentandtherangeoftestcurrentsused.Aloopresistancetestercanmeasurewithintherangeof100–600

A,whileaDCresistancetestertypicallymeasuresatthepositionof1/3/5/10/30

A.DCresistanceismainlyusedintransformertesting,whileloopresistanceisprimarilyappliedtodevicessuchascircuitbreakersanddisconnectswitches.Ⅰ.PurposeofLoopResistanceTestingTheconductivecircuitofhigh-voltageswitchgeariscomposedofmultipleconductorsthatallowelectricalconductionthroughcontact.TheDCresistanceoftheconductivecircuitincludesnotonlytheDCresistanceoftheconductormaterialitselfbutalsothecontactresistanceofvariouselectricalcontacts.TheconductivecircuitofGasInsulatedSwitchgear(GIS)isevenmorecomplex.Theresistanceoftheconductoritselfdependsontheresistivityoftheconductormaterialanditsgeometricdimensions.Ⅰ.PurposeofLoopResistanceTestingInthelong-termoperationofelectricalswitchequipment,thecontactresistanceisaffectedbychemicalcorrosion,mechanicalwear,electricalwear,shortcircuitcontactweldingandotherfactors.Ifthecontactresistanceistoolarge,theheatgeneratedunderthelong-termoperatingcurrentwillincreasewiththeincreaseinresistance,thetemperatureoftheelectricalcontactrisessharply,whichmayresultinadeclineintheinsulatingpropertiesoftheinsulatingmaterialandmechanicalstrength,Theoxidationofthecontactsurfaceleadstofurtherdeterioration.Inseverecases,itmaycausepartialweldingofthecontact,affectingthenormalopeningandclosingoftheswitch.Whenpassingtheshort-circuitcurrent,itwillalsoaffectthedynamic,thermalstabilityandinterruptionperformanceoftheswitch.Ⅰ.PurposeofLoopResistanceTestingIfthecontactresistanceistoohigh,theheatgeneratedbytheworkingcurrentwillincreasewiththeincreasingresistanceovertime.Thetemperatureoftheelectricalcontactwillsharplyrise,whichmaycausetheinsulationperformanceandmechanicalstrengthoftheinsulatingmaterialtodecrease,andthecontactsurfacetooxidizefurther,resultinginmoreseveredeterioration.Inseverecases,localweldingofthecontactmayoccur,whichcanaffectthenormalswitchingoftheswitch.Whenshort-circuitcurrentflowsthrough,itcanalsoaffectthedynamicandthermalstabilityperformanceandbreakingperformanceoftheswitch.Ⅰ.PurposeofLoopResistanceTestingContactresistanceisaffectedbyfourmainfactors:materialproperties(aluminum,copper,silver,tin),contactform(pointcontact,linecontact,surfacecontact),contactpressure,andprocessingtechnologyofcontactsurfaces.Therefore,currentandresistancemeasurementsoftheconductivecircuitareastandardtestingitemintypetests,factorytests,handoveracceptancetests,andpreventivetestsofhigh-voltageswitches.Theresistancevalueofeachphase’sconductivecircuitofelectricalswitchgearisanimportantdataforinstallation,maintenance,andqualityacceptance.Bymeasuringthecontactstateofelectricalcontacts,safeoperationoftheswitchgearcanbeensured.TakeFigure3-6asanexample.Ⅰ.PurposeofLoopResistanceTestingFigure3-6

35

kVcircuitbreakeranddisconnectswitchⅠ.PurposeofLoopResistanceTestingTheloopresistancetestistomeasurethecontactresistanceoftheconductivecircuitoftheswitchwhenitisintheclosedposition.Itchecksforanycontactdefects,whetherthecircuitiswell-connected,andifthereisanyoxidationonthecontactsurface.Theresistanceoftheconductivecircuitoftheswitchgearmainlydependsonthecontactresistancebetweenthemovingandstaticcontactsofthecircuitbreaker(disconnectswitch).Thepresenceofcontactresistanceincreasesthelossoftheconductorduringpowertransmission,raisingthetemperatureatthecontactpoint.Themagnitudeoftheresistancedirectlyaffectsthecurrent-carryingcapacityduringnormaloperation,andtosomeextent,theabilitytointerruptshort-circuitcurrents.Ⅱ.ConductiveCircuitTestinHighVoltageSwitchElectricalswitchgearrequiresthatthetemperaturerisedoesnotexceedacertainvaluewhentheelectricalcontactpassesthroughtheratedcurrentforalongtime,andthecontactresistancemustbestable.Whenashort-circuitcurrentpassesthroughtheswitchgearforashortperiod,itisrequiredthattheelectricalcontactdoesnotresultinweldingorsplashingofcontactmaterials.Duringtheclosingandopeningprocessoftheswitch,thecontactshouldbeabletohandletheshort-circuitcurrentwithoutcausingweldingorseveredamage.Duringtheopeningprocess,itisrequiredthatthecontactwearshouldbeminimizedasmuchaspossiblewhenbreakingthecurrent.Ⅱ.ConductiveCircuitTestinHighVoltageSwitchTheDCresistancevalueoftheconductivecircuitinahigh-voltageswitchisdeterminedthroughtypetestingoftheproduct.AccordingtotheGB/T11022standard,DCresistancemeasurementshouldbeconductedbeforeandaftertemperature-risetests.Themeasurementshouldbetakenunderthesameconditionsasthetestcycle’stemperatureofthetestconductorandambientairtemperature.Thedifferenceinresistancebetweenthetwomeasurementsshouldnotexceed20%oftheresistancevalueobtainedbeforethetemperature-risetest.Ⅱ.ConductiveCircuitTestinHighVoltageSwitchThisregulationrequiresthattheDCresistancevaluemustbedeterminedbyactualmeasurementstoensurelong-termcurrent-carryingcapacityandperformancewhenpassingthroughextremeshort-timecurrents.WhenmeasuringDCresistanceduringfactorytests,itisnecessarytoobtainameasurementassimilaraspossibletothetypetestconditions(ambientairtemperature,locationofthemeasurement).Themeasuredresistanceshouldnotexceed120%oftheresistanceobtainedbeforethetemperature-risetest.Ⅱ.ConductiveCircuitTestinHighVoltageSwitchThemeasurementmethodmainlyadoptsthedirectcurrentvoltagedropmethod.Acertaindirectcurrent(generallynotlessthan100

A)ispassedthroughtheconductivecircuit,andthevoltagedropoftheconductivecircuitismeasuredusingadirectcurrentvoltmeter.ThedirectcurrentresistanceoftheconductivecircuitisthencalculatedusingOhm’sLaw.Sincethecurrentpassingthroughthetestspecimenisrelativelylarge,itissufficienttobreakdownthemetaloxidefilmonthecontactsurface,therebyreducingmeasurementerrors.Thedataobtainedfromthemillivoltmeterinthecircuitresistancemeterisrelativelyaccurate.TheprincipleofthedirectcurrentvoltagedropmethodisshowninFigure3-7.Ⅱ.ConductiveCircuitTestinHighVoltageSwitchFigure3-7

SchematicdiagramofthedirectcurrentvoltagedropmethodⅡ.ConductiveCircuitTestinHighVoltageSwitchWhenmeasuringtheDCresistanceoftheconductivecircuitinopen-typehigh-voltageswitchgearsuchasvacuumcircuitbreaker,SF6circuitbreaker,anddisconnectswitch,pleasenotethefollowing:Thevoltageleadsshouldbeconnectednearthecontactside.Thecurrentleadsshouldbeconnectedtotheoutsideofthevoltageleads.Ensuregoodcontactbetweenthevoltageandcurrentleads.Ifnecessary,polishthecontactsurfacewithsandpaper.Beforemeasuring,theswitchshouldbeoperatedseveraltimesatitsratedoperatingvoltageandgaspressure(oroilpressure)toensuregoodcontactwiththecontacts.Ⅱ.ConductiveCircuitTestinHighVoltageSwitchThisallowsthemeasurementresultstoreflecttheactualconditions.Theshort-circuitbreakingcurrentsthattheSF6circuitbreakercanhandlearerelativelylarge.Thenameplateofa220

kVSF6ZF16-252GCBcircuitbreakerisshowninFigure3-8.(a)220

kVSF6

CircuitBreakerZF16-252GCBNameplate(b)220

kVDisconnectorZf16-252DSNameplateⅡ.ConductiveCircuitTestinHighVoltageSwitch(c)

220

kVEarthSwitchZF16-252ESNameplateFigure3-8

TheNameplateⅡ.ConductiveCircuitTestinHighVoltageSwitchThewiringdiagramfortheloopresistancetestisshowninFigure3-9.Figure3-9

WiringDiagramforLoopResistanceTestⅡ.ConductiveCircuitTestinHighVoltageSwitchThetestprocedureisshowninTable3-3.Table3-3

PreventiveTestProcedureforConductiveCircuitResistance02WorkshopⅠ.MethodformeasuringthemainloopresistanceofGISThemainloopresistanceofGISismainlymeasuredusingthegroundingswitchcircuit.Ifthereisinsulationattheconnectionpointbetweenthegroundingswitchandtheshell,themeasurementcanbetakenbyopeningtheconnection.Ifthereisnoinsulationattheconnectionpointbetweenthegroundingswitchandtheshell,firstmeasuretheresistanceR1oftheGISshell,thenmeasuretheresistancevalueR2afterthecircuitisinparallelwiththeshell,andthencalculatethemainloopresistanceR=R1R2/(R1-R2).Forasleevewithoverheadlinesenteringit,themeasurementcurrentcanalsobeinjectedfromthesleeveside,andthemeasurementpointsshouldbeasdenseaspossible.Ⅰ.MethodformeasuringthemainloopresistanceofGISFigure3-10showsahigh-precisioncircuitresistancetester.Figure3-10

HighPrecisionLoopResistanceTesterⅠ.MethodformeasuringthemainloopresistanceofGISThewiringprincipleformeasuringtheGISloopresistanceisshowninthefigure3-11.(a)Schematicdiagramofresistancemeasurementwiring(b)WiringdiagramforinjectingcurrentfromthesleeveandmeasuringvoltagefromthegroundingswitchⅠ.MethodformeasuringthemainloopresistanceofGISThewiringprincipleformeasuringtheGISloopresistanceisshowninthefigure3-11.(c)Wiringdiagramforinjectingcurrentfromthegroundingswitchandmeasuringvoltagefromthegroundingswitch(d)WiringdiagramforinjectingcurrentandmeasuringvoltageatthesamelocationFigure3-11

ThewiringprincipleformeasuringtheGISloopresistanceⅡ.LoopResistanceMeasurementAftercorrectwiring,themeasurementmaininterfacewillbedisplayedwhenthedeviceisturnedon.ThisisshowninFigure3-12.Figure3-12

MeasurementmaininterfaceⅡ.LoopResistanceMeasurementClickthe“Measure”buttontostartthemeasurement.Themeasuredresultis20,indicatingthatthedataisqualified.ThisisshowninFigure3-14.Figure3-14

MeasurementresultsⅡ.LoopResistanceMeasurementTheloopresistancetestprocedureisshowninTable3-4.Table3-4

LoopResistanceTestProcedureⅡ.LoopResistanceMeasurementTestNotes:(1)ApplyanyvalueofDCcurrentbetween100

Aandratedcurrentinthecircuitandmaintainitfor1minute.(2)Measurementshouldbeperformedusinginstrumentsthatreflectaveragevalues,withaprecisionofnotlessthan0.5gradeformeasuringmeters.(3)Thevoltmeterisconnectedontheinnersideofthetestedcircuitandisswitchedonafterthepowercircuitisconnected,topreventmeasurementinterruptioncausedbysuddentrippingofthecircuitbreakerorsuddendisconnectionofthemeasurementcircuitthatmayresultindamage.Ⅱ.LoopResistanceMeasurement(4)Iftheinfraredthermalimagingdisplaysabnormaltemperaturesatfracturesurfaces,abnormaltemperaturedifferencesbetweenphases,oriftherehavebeenmorethan100switchingoperationsofthecircuitbreakerafterthetest,thistestshouldalsobeconducted.(5)Theloopresistancetestinginstrumentshouldbereliablygrounded.Ensuregoodcontactontheclampingsurfaceofthemeasurementcable,andthetestcurrentshouldnotbelessthan100

A.Removepaintandmetaloxidelayersfromthecontactsurfacesofthetestedequipment’sterminalconnections.Performseveralopeningandclosingoperationsonthecircuitbreakerbeforethetesttominimizetheimpactoftheconductivecircuitoxidefilmonthetestresults.Ⅱ.LoopResistanceMeasurementItisnotallowedtoenergizewhenthetestcableisopen-circuited,asitmaydamagetheinstrument.Tominimizevoltagedropinthemeasurementcable,trytoreducethelengthofthecableandusethecablewithasufficientlylargecross-sectionalarea.(6)Duringthemeasurement,preventsuddentr

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论