版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
GeN2调试手册
FieldEngineeringDepartmentFED
目录
1.0.总鉴.................................................4
1.1.技术总览...........................................5
1.2.系统要求...........................................5
2.0.检修模式的启动......................................6
2.1.检查接线及主电源...................................6
2.2.送电操作...........................................6
2.3.启动TCB.......................................................................................8
2.4.启动SPB......................................................................................8
2.5.确认RSL及服务器通信...............................9
2.6.启动BRE(电子释放抱闸装置)......................10
2.7.确认MCB信号及参数................................11
2.7.1,合同参数(M-3-1)....................................................11
2・7.2.运行曲线参数(M-3-2-).................................................13
2.73其它参数(M-3-4、M-3-5-2)......................................13
M
2.8.TCB参数设置..............................
2.9.编码器的调整..............................14
2.10.检查运行及编码器方向......................17
3.0.检查安全装置.................................18
.18
3.1.安全钳及其传动机构的测试.................
3.2.测试BRE(电子释放抱闸装置).............
4.0.平层感应系统................................18
5.0.第一次正常运行..............................20
5.1.串行通信链路...............................20
检查井道信号...............................20
5.2...21
6.0.启动门系统DCSS4、5...................................................21
7.0.自学习运行...................................
7.1.自学习运行...............................
7.2.厅门检测程序..............................23
8.0.启动LWB称重装置...........................24
8.1.参数确认..................................25
.25
8.2.偏移量校准................................25
8.3.增益量校准................................26
8.4.负载的监测................................26
9.0.平层精度调整................................26
9.1.•••••••••••••••••••••••••••••••••••••••••••27
9.2.平层精度.28
.28
10.0.参数储存......................................29
11.0.TCB的进一步功能启动........................
嗡
11.1.楼层位置指示器...........................
11.2.检查ADO与RLV功能......................%
11.3.远程监控系统..............................
12.0.SPB的使用...................................
12.1.介绍......................................
,30
12.2.缩写说明..................................之
12.3.接口说明..................................
12.4.状态灯LED说明...........................
12.5.电池充电显示..............................
12.6.按钮......................................,1
..37
12.7.扩展功能..................................啜
12.8.其它部件说明..............................
12.8.1.REM服务按钮..................J
12.8.2.门区显示器.....................
12.8.3,合同速度显示器.................
12.8.4.轿厢位置显示器...................39
12.8.5.轿厢速度各方向显示..............410
12.8.6.蜂鸣器.........................
।7R7通信检查
13.0.OVFww(MCB)对艮巍使前...................
..43
13.1.服务器菜单流程图.........................,
13.2.服务器显示,监测(M-1)...................................
13.3.测试......................................
13.4.缩写解释......................................4
...48
13.4.1.运行命令状态及说明..............................48
13.4.2.运行逻辑状态及说明..............................49
13.4.3.量^^♦♦•♦・•♦・・♦♦♦♦♦•♦♦・・・・♦・.♦♦♦♦♦・♦♦•♦・♦•・♦♦♦♦♦♦・♦・•50
14.0.OVFww驱动故障信息.........................................50
14.1.故障记录格式及说明(M・2・2)..........................................................................50
14.2.1系统与运行控制信息..........................................51
14.2.2驱动器警告信息..............................................51
14.2.3称重系统相关信息...........................................51
14.2.4运行指令信息...............................................51
14.2.5运行逻辑状态相关信息.......................................51
14.2.6驱动控制相关信息...........................................51
14.2.7自学习运行及PCT调整相关信息...............................51
14.3.MCB参数表..................................................59
1.
"heGen2-Systemisanmachineroomlesssystemoftheelevatorcontrol.
Therearetwocontrollercabinets;GeN2isamachine-room-lessliftwithunsurpassedlevelsofcomfort,
reliabilityandsafety.GeN2offerspassengersaquieter,smooth—andmoreelegantridethananylift
systeminitsclass.Itsdesignenablesarchitectstodesignbuildingswithoutamachineroom.Builderswill
benefitfromquickerinstallationandminimalinterferencewithothertrades.Andownerscanoperatethe
buildingmoreeconomicallyandwithmorerentablespace.
GeN2是由一个无机房电梯系统控制的,包括以下两主要控制部分:
GeN2是一种舒适的,高可靠性和安全性的无机房电梯.GeN2电梯提供给乘客更宁静的,
平滑的和一流的运行。它使建筑师无须考虑电梯的机房。所以建筑商可得益于在其贸易方面
更快的安装及更小的干扰。及业主能有更多可出租的空间,有更高的经济效益。
■thecontrollermountedinthehoistwaycontentstheOperationalcontrolandDrivecontrol.The
OperationalcontrolisrealizedbytheTractionControlBoard(TCB)andtheDriveControlbythe
MotionControlBoard(MCB)/VectorControlBoard(VCB).
主控制柜安装在井道,包括操作控制和拖动控制。操作控制通过牵引控制电子板
(TCB)实现,拖动控制通过动行控制电子板(MCB)和矢量制电子板(VCB)实现。
-theE&l-panelmountedinthehoistwaydoorpanelattoplandingcontentstheServicePanelBoard
(SPB),theBrakeReleaseBeard(BRE),theERO-ControlandtheEmergencyPowerUnit.
E&l控制屏安装在顶层厅门旁,包括检修电子板(SPB),抱闸释放电子板(BRE),
ER。一检修开关。
AfurtherBoard,theLoadWeighingBoard(LWB)ismountedintheCOP.
AndfortheDoorcontroltheDoorControlSubsystemDCSS5isused.
还有其它电子板,如电子称重板(LWB)安装于COP,门机控制板等。
,技术总览
ThefollowingChartgivesyouanoverviewabouttheusedControlSubsystemsofthewholeGen2-System.
下列图表给出一个关于整个GEN2的各个控制子系统的定位总览。
1.2.系统要求
StartingupoftheWWOVFDrive-Systemonlyshouldbeperformedbyauthorisiziedpersonal!
WWOVF驱动系统启动只应由经授权的人员执行!
"hemechanicalworksofhoistwayandcabineaswellastheelectricalinstallationinthehoistway,
controllerandE&lPanelhavetobefinishedtoensureinspectionrun.
必须完成井道和机房的机械工作以及在井道、控制柜和E&I板的电气安装以确保检修运行.
-heencoderhavetobemountedatmachineandproperlyconnectedwithMCB.
一定要将编码器安装在主机上并正确地与MCB连接
-heelectricalconnectionshavetobeinstalledcompletelyandchecked.
必须完整地安装电气连接并检查.
2.0.以检修模式运行
Thftmftchaninalworksofhostway,nahine,contrnllftr,machineandRlftctricalinstallationhavetnhn
finishedinthisway,thatthefirstinspectionruncanperformed.Theelectricalconnectionsbetween
Controller,E&l-panelandmachineandhoistway-installation(SafetyChain:TES,OS,GTCandPES)
havetobeinstalled.ConnectthetravellingcablewiththeTOCI-boxvia"FieldShunt',(AdapterToolfor
connectionoftravellingcableandTOCI-boxduringconstruction).Forconstructionmodeitispossibleto
bridgedoorcontactswithplugP4TintheE&l-panel.
井道的机械工作,轿厢,控制柜,主机和有关的电气接线等在第一次检修运行前必须完
成,在控制柜,E&I控制屏,主机和井道线间的电气连接(安全回路:TES,OS,GTC和
PES)电气连接,连接随行电缆到轿顶接线箱。
2.1.检查接线及业主电源
Ensurethatthemainswitchisswitchedoff(E&l-panel)!
SwitchtoERO-mode(E&lpanel).
首先确定在E&I检修控制柜中的主电源开关己断开,及将ERO检修开关置于检修状态.
DisconnecttheconnectionofHL1toPEandHL2toPE.
ChecktheHL1/HL2andPEwiringandinsulation.Thisisachecktotestthecleardisconnectioncfthe
HL1/HL2/PEwiring.
断开接地汇流条PE,HL1,HL2间的夸接线,检查HL1与HL2对地PE的绝缘,ERO仍置于检
修状态。
-heresistancevalueshavetobechecked(withmultimeter):
用万用表检查绝缘电阻值:
■fromPEtoHL1(>0,5MQ)
从PE至UHL1(>0,5MC)
■fromPEtoHL2(>0,5MQ)
从PE至UHL2(>0,5MQ)
■fromPEtothelineterminalsL1-L3(>0,5MQ)
从PE到三相电源线端L1-L3(>0,5MC)
■fromPEtothemotorterminalsU1-W1(>0,5MQ)
从PE到马达电源线端U1-W1(>0,5MQ)
PutintheHL1/HL2/PEconnectionagain.
完成后将夸接线装回。
2.2.送电操作
ConnectthebatterytoplugP1ontheBREboardtoensurethatthebatteryischargedforstartupof
BREboard(Chapter6).
将E&l检修控制柜中的12V电池插端P1连接到BRE板上。
Switchonthemainswitch(OCB).
Checkthelinevoltage(400VAC-L3).
SwitchonthefuseF4C(controller).
将控制柜的F4c开关闭合,送E&l检修控制柜的主电源,检查相间电压为380V。
CheckthewiringandfunctionofthesafetyswitchesTES,OS,GTCandPESwithvoltmeter.
Checkthefunctionbymeasurementofvoltageloss(110VAC)atolug2H4toHL1byopeningofthesafety
switches.
用万用表检查安全回路TES,OS,GTC及PES等开关的110V电压。
1)SwitchtheunittoEROoperation.
转为ERO操作
2)Switchonthemainswitch.
接通主开关
3)Checkthepowersupply110VAC(P1.8)andHL1connection(P1.7)accordingtothewiringdiagram.
按照接线图检查电源供应110VAC(P1.8)和HL1连接(P1.7)
4)ConnecttheServiceTool(SVT)toMCB(PlugP6)
连接服务器(SVT)至MCB(插头P6)
5)Afterswitchingon,theDR(DriveReady)-signalonSVTmustbeactive,itindicatesthereadinessof
theinverter.
接通后,在SVT上的DR(驱动准备卜信号必须是被激活的,它表示驱动器准备变绪.
6)Itmustbecheckedifthefollowinginputs/outputsoftheMCBhavethecorrectvoltageof24VDC
必须检查是否以下MCB的输入/输出有24VDC正确电压
P3.2(24V-output输出)
P4.7(/1LS-signal信号)
P4.8(/2LS-signal信号)
P3.1(DBD-signal信号)
每点对P3.3(HL2)测量
2.3启动TCB
ChecktheproperinputswiththehelpoftheTCB-LEDindications(carisinlevelandinEROmode):
在轿厢在平层位置及检修状态下,观察TCB板上的指示灯的状态。
LEDDescription描述State状态
VLC逻辑电压5VDCOn
GRP/J线电压相位错相Off
NOR/DIAG正常运行状态Off
INS检修运行状态On
ES急停状态Off
DW厅门状态On
DFC轿门状态OnQff(检修状态下不定)
DOL门全开状态OnOf((检修状态下不定)
DOB开门按钮状态OnOf((检修状态下不定)
DZ平层状态Off(只有平层时亮)
RSL远程通信链路状态闪烁
注:如在送主电源后,指示灯的状态与下表中不符,请检查相应的的电路。
2.4.启动SPB板
EnsuretheSVTconnectionbetweenTCB(PlugP3)andSPB(plugP14).
EnsuretheSVTconnectionbetweenMCB(PlugP6)andSPB(plugP17).
Remark:ThecommunicationbetweenTCB/MCBandSPBwillguaranteedwiththisconnection.
确定在TCB(P3)与SBP(14)间,MCB(P6)与SPB(P17)间的导线已连接。
注:TCB/MCB板与SPB板间的通信线必须成功连接。
ChecktheconnectionoftheSpeedencoder.
检查速度编码器的接线。
SettheRSLaddressoftheSPBtothestandard
SW1address62(switchSW1).
将SPB板上的SW1地址开关设为62。
电压检测
•SwitchontheOCB
送主电源
・Usingadigitalmultimeter,checkthevoltagesupplyofthepluggedconnectorstotheSPBasfollows:
按下袤用万用表检查SPB板下各接口的电定:
ConnectorMeasurementpointsvoltage(tolerance)
接口测试点庖压范围
P2P2:4-P2:330VDC(27-36VDC)
Pll:3-P3:210-14VDC
PHPU:2-P3:210-14VDC
Pll:l-P3:210-14VDC
P12P12:1-P12:2正常状态:14VDC(13,3-14.7VDC)
电池供电状态:10/4VDC
P13正常状态:14VDC(13.3-14.7VDC)
Gen2:Pl3:1/2notused电池供电状态:10-I4VDC
2.5.确认RSL远程及服务器通信
•ConnectP2andPl4totheSPB
•PressthebuttonREB&CCTLsimultaneous
ifthe7-segmentLEDsDISIandDIS2shows'Sr',thecommunicationof
RSLandSVTisverified
or
•PressanyButton(durationapprox.2s)ofthebuttonfield
fifthestatusLEDlitson.thecommunicationofRSLandSVTisverified
ConnecttheSVTtoplug15onSPB.
With<Module><1><1><2><GOON>checktheinputsignalsSE,/1TH,/2TH,INS,/ES,DW,DFC,the
signalsmustbeactive(capitalletters).
ConnecttheSVTtoplug16onSPB.
With<Module><1><2><GOON>checktheinputsignalsBY,DBDandBSW.
"heDR(DriveReady)-signalmustbeactive,itindicatesthereadinessoftheinverter
连接P2与P14到SPB板,同时按板上的REB与CCTL按钮,如板上LED显示为“Sr”,
则已确认RSL远程及服务器通信;或按任一按钮2秒,如其指示灯亮,则确认RSL远程及服
务器通信。
连接服务器到SPB板的P15,按〈Module><1><1><2><GOON>,检查SE,/1TH,/2TH,INS,
店S,DW,DFC,等信号是否被激活(大写有效);连接服务器到SPB板的P16,按
<Module><1><1><2><G00N>,检查BY,DBDandBSW的输入状态,DR(驱动器正待命信号)
必须有效,它表明驱动器正处于待命状态。
2.6.启动BRE板(电子释放抱闸板)
一heconnectionbetweenBRE(PlugP2)andSPB(PlugP11)hastoberealized.
连接BRE板(P2)与SPB板(P11)。
PowerChecks
电压检查
CheckthecorrectwiringofthePugsP1andP2.
CheckthevoltagesupplyofthepluggedconnectorP1byusingofamultimeter,
检查Pl与P2的接线,并用万用表接口电压。
Connectormeasurementpointsvoltage(tolerance)
接口测试点庖压范围
PlP1:5-P1:I12VDC(10,2-13,8V)(电池)
PlP1:4-P1:212VDC(10,2-13,8V)(电池)
P2P2:2-P2:512VDC(I(),2-13,8V)(电池)
按住BRB!按钮
P2P2:4-P2:512VDC(10,2-13.8V)(电池)
P4P4:1-P4:3110VDC+/-10%(抱闸)
75VDC+/-10%(维持抱闸开电压)
断开P4接口时才可测量。
LED状态灯检查
通常状态下
各状态灯定义如下:
二表示LEDoff熄灭
Z表示LEDon常亮
□表示LEDiscontinuousflickering不断闪烁
StateofbuttonsStateofLED's指示灯状态
functiondescription按钮状态LED2LED1description
功能描述BRB1BRB2*(BRB2)(BRB2)描述
BRE板不工作按下未接通£
BRE板工作按下接通££RescueoperationwithBRE
□□BRE板拯救操作
2.7.确认MCB信号及参数
用〈Module><1><2><GO0N>检查输入信号BYCHK和DBD
FundamentalParameterSetup
基本参数设置
Normallyallparametersarepreadjustedforstart-up,i.e.runsinERO-orINS-Modeshouldbeableto
carryoutimmediately.
通常所有参数在工厂都己预先调好,即应能够立即执行以ERO或INS模式的运行
ForrunsinnormalmodeaLearnRunisneccessary.
为了以正常模式运行,需要一个学习运行
OnlyincaseofShutDownyouhavetochecktheparameters.
万一停梯,你必须检查参数
(M-3-1)
CONSPE:确定的电梯合同速度
例子:合同速度是1,60米/秒=ConSpe=160
ConNmot:要求的电机R.P.M达到合同速度
例子:速度达到611RPM设ConNmot=611
注:ConNmot可与Nnom.ConNmot不同
Motortype电机类型:使用的电机类型
OPTimus630x1.6=>setMotortype=500
=setMotortype=501OPTimus630x1.0=set
Motortype=502
OPTimus1000x1.0=setMotortype=503
SysInert:总系统惯性
shouldbepreadjusteddependingonthecontract.
应根据合同预先调整
TheparameterSysInertcanbedeterminedb/followingcalculatinginstructions.
按以下计算指引确定参数Sys惯性.
SysInert=9tot=Omot+(mi+m2)
4吠2g
0tot=Systeminertia系统惯性[kgm2]
0mot=Motorinertia电机惯性[kgm2]
d=Tractionsheavediameter曳引轮直径[m]
X=Roping绳比[1]1即1:1,2BP2:1
匕=Gearratio齿轮比[1]例如:17即17:1
mi=Massofcounterweight对重质量[kg]
m2二Massofcar(empty)轿厢质量(空)[kg]
Typicalsysteminertiasareintherangeof0.5-2.5kgm2.
典型的系统惯性在至2.5kgm2范围
Encodertype编码器类型:使用的编码器类型
例子:HeidenheimSinus/Cosimis编码器设编码器类型=3
LoadWtype称重装置类型:称重装置的使用
例子:相似体称重带LWB设LoadW类型=2
Necessarytoavoidrollbackwithoutloadweighing
须避免在无称重装置时溜车,在森装装置无效时暂设置为“0”.
2LVavail.:选择1或2个感应器应用的参数
例子:假如只使用1LV设2LV=0
DDP:DDP时间(设缺省值20秒),
假如要求,必须根据铭牌速度和提升高度提高
TOPFLOOR顶层:顶楼位置
例子:对于8层楼的电梯设TOPFLOOR=7
FLOORSIN1LS:在1LS的楼层数
例子:在1LS范围之内的一楼层设FLOORSIN1LS=1
MCBoperat.:MCB的使用
例:带TCB的标准类型,设MCBoperat=0
BrakeSWtype:使用抱闸的开关类型
forOptimusnBrakeSWtype(make&breakcontacts)
GeN2的主机抱闸开关类型为“2”。
MotorDir:电机方向
0:最初的
1:相反的曲线方向和MCB速度方向编码
EncoderDir:编码器方向
改变MCB速度方向的极性方向编码对曲线方向
当出现“DRV:Encoderdir”时必须栓牢
3.7.2.曲线参数(M-3-2)
通过ConSpc的设定调整共同的速度曲线
INSSPE:检修运行速度(最大米/秒)
例似0.35米/秒检修运行设INSSPE=35
NOMSPE:持续运行的铭牌速度
能够用这个参数来降低铭牌速度
例子:对于一台应以米/秒运行的电梯,但为米/秒铭牌速度设计
参数CONSPE被调至米/秒].NOMSPE能够从160减至米/秒]运行.
2.7.3.MCB其它参数设置
Start/StopParameter(M-3-4-GOON)
ProfDelay*=10
VCBCtlParameter(M-3-5-2-GOON)
SpCFNr*=10()
SpCFN0*=100
Allparametersarepreadjusted(TCBandMCB)forNormaloperationbyfactory.Theparametersetup
shouldbecheckedincaseofmalfunctiononly.
Itisnecessaiytosetfollowingparametersforinspectionrun:
在TCB与MCB板中的蓼数已由工厂按正常运行状态预设,在遇故障时可检查参数设置,但须
设以下参数用于检修运行状态。
ServiceParameter(M-1-3-1-7-GOON)
Encodcr=13
SDI-Dir=0
SDI-Max=30
Spe-Rng=20
SPB-Temp=60
BRE-Max=20Attention!Thevalueofthisparametershouldbe
changedonlyincaseofthecardoesnotmoveduring
rescueoperation.
注意:此项参数只有万一在拯救运行中轿厢不能运动才需更改。
BRE-Min=7
BRE-Hold=20
BRE-Tout=5
SYSTEMParameter(M-1-3-1)
TOP二据实际层楼位置-1
DoorParameter(M-1-3-1-5-GOON)
Door=12
CM-Typ=0
TRO-Typ=0
2.9,编码器的调整
Toaligntheencoderaxistothemagnetaxisofthesynchronousmotortheencoderadjustmenthasto
beperformedbeforethefirstinspectionrun.NormallytheEncoderadjustmenthastobeperformedwith
mountedbelts,car,counterweightandemptycarForInspectionmodeitispossibletoperformthe
adjustmentwithoutbeltsetc.Itisaseparatelyinputforthisencodertype.Inthiscaseyouhavetoperformthe
encoderadjustmentlateragainwithmountedbeltsetc..
在第一次检修运行,主机马达或更换主PVT后,为使同步电机上的电子式编码器(主PVT)
与磁编码器(副PVT)及主机马达同步运作,必需进行电子式编码器(主PVT)调整。正常
情况下,编码器的调整必须在已安装钢带等及空负载下完成,对于这种编码器类型,它是一种
分离输入,但在检修运行情况下,可暂时不安装钢带等装置,等随后完成安装后再进行一次编
码器调整
TheencoderhastobeconnectedtoplugP10onMCB.Itisaseparatelyinputforthisencodertype.
Afterconnectionofencoderyouhavetostarttheencoderadjustment
PlugintheSVTtoplugP16onSPB.
将电子式编码器连接MCB板上的P10,是一个独立的接口,并连接服务器到SPB板的P
16进行编码器调整操作。
TheadjustmentisperformedautomaticallybystarttheSVTmenu..EncoderAdjustment*1(<M><4><2>).Follow
theinstructionontheSVTdisplay.SwitchfromEROtoNormalmodeandbackwithEROswitchintheE&lpanel
duringadjustment.Ifadjustmentnotpossible,checktheerrorlogging(M-2-1-GOON).Inthiscaselookat
thespecialFCMforMCB/VCB.
通过服务器该操作可自动完成根据服务器上的指示,在调整过程中转换ER
。检修开关。如调整被中断,检查故障记录(M-2-1-GOON),故障记录详细解释可在
MCB/VCB的第十章中查得.
Afterconnectionofencoderyouhavetostarttheencoderadjustment.
连接编码器后,开始调羲编码器
ChecktheparameterEncodertypeisproperlysetagain.
检查是否正确设定参数Encodertype
Encodertype=3,ifaSinusencoder(HeidenheimSinus/CosinusEncoder)isused
如果使mSinus编码器(HeidenheimSinus/Cosinus编码器),编码器类型二3
TheadjustmentisperformedautomaticallybystarttheSVTmenuEncoderAdjustment"(<M><4><2>)
.通过启动SVT菜单EncoderAdjustment(<M><4>v2>)自动执行调整
Learn学习=1
EncoderAdj编码器调整=3
switchonNORMALonERO-Box
按在ERO盒上的NORMAL
接通在ERO盒上的ERO
按月艮务器上的vENTER>键
按月艮务器上的〈ENTER,键
执行编码器调整
按在ERO盒上的NORMAL
成功地完成编码器调整
Learnabort!
xxxxxxxx
编码器调整被故障中断,寻找原因并重复调整
Ifadjustmentnotpossible,cheektheENGVCBParameter(<M><3><5><1><G0ON>)
Encodertype,MotorDir,EncoderDir.NowtheoperationinINS/EROmodeshouldbepossible.
假如不向*能调整,检^SENGVCB参数(VM><3><5><1><GOON»Encodertype,MotorDir,
EncoderDir.现在INS/ERO检修模式应可以运行。
2・10..检查运行及编码器的方向
AftersettingofContractparametersandencoderadjustmentyoushouldchecktherundirectionwith
theERO-Botton.
在合同参数设定和编码器调整后,你应该用ERO按钮检查运行方向。
ChecktherundirectionwiththeERObutton(E&lPanel).ForINS-orERO-operationtheMCBneedstheinput
signalsUIBorDIB(MCB:M-1-2-GOON).WiththeSVTthestateofthedrivecanbecontrolled(MCB:M-1-1).
以E&I检修控制柜的检修按钮运行,在服务器中(MCB:M-1-2/1-GOON)可监测得MC
B的UIB,DIB信号各驱动状态。
BypushingofUP-orDOWN-buttonthemotorwillstart.
Iftheerrormessage"EncoderDir"willdiplayed,thentheparameterEncoderDir(M-3-1-GOON)hastobe
changed(0/1).Iftherundirectionisnotthesameasthewanteddirection(directionofthecarisnot
correspondingtopushedUIB/DIBbutton),thentheMCB-ContractParameterMotorDir(M-3-1-GOON)
havetobechanged.Ifthecardoesnotmove,theerrorcanbedetectedbymeansofstatusdisplay.ltShutDown
(SHTDWN)isdisplayedthereasoncanbefoundoutbymeansofErrorlogging(ErrLog)(M-2-2-1-GO
ON).InthiscaselookatthespecialFCMforMCB/VCB.
CheckthedirectionalsofromtheTopofCarInspectionbypushingtheTCI-bottonUPandDOWN.Nowthe
operationinINS/EROmodeshouldbepossible.
按上或下按钮马达会启动,如服务器显示"EncoderDir(编码器方向)”,则需更改MCB板上
参数(M-3-1-GOON)“EncoderDir(编码器方向0/1)”;如上下行方向与所按运行方向不
符,则更改MCB上参数“MotorDirO/l(M・3・l・GoOn)・;如电梯不运行,会有当前故障信息显
示在服务器上,当显示“SHTDWN”表示电梯终止运行,可通过检查故障记录(M-2-2-1-
GOON)得出导致故障原因(故障记录请查第14章)。在E&I检修控制柜运行正常后,还须
在轿顶运行检修,运行超过五秒电梯不出现异常表明已成功进行检修运行。
一hestatusofthedrivecanbecontrolledviaServiceTool(<M><1><1><GOON>).
驱动状态可以通过服务器控制(vM><1><1><GOON>)
BypushingofUIB-orDIB-buttonsthemotorwillstart.
按U旧•或D旧按钮电机将会启动
Iftherundirectionisnotthesameasthewanteddirection,thenchangethedirectionbysettingofthe
ContractparameterMotorDir[Od]to1(Default=0).
假如运行方向与想要的方向不同,那么通过设定合同参数MotorDir[0/1]to1
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 新生儿低血糖:筛查·喂养·静脉补糖·持续低血糖管理(2026版)
- 内蒙古呼和浩特市2025年一级建造师考试(机电工程管理与实务)题库含答案
- 贵州安顺市2025年下半年全国英语等级考试(PETS)二级仿真试题及答案解析
- 2026年中小学德育工作培训考试试卷及答案
- 2026年网络规划设计师考试真题及答案
- 2026年煤矿安全生产管理人员安全资格证培训题库及答案
- 2026年海南师范大学公开招聘员额制专任教师11人笔试模拟试题
- 2026年儿科护士综合测试题库
- 2025专业技术人员绿色低碳创新冲刺押题实战卷
- 关于肾上腺素和副肾的考试试题及答案
- T/CHTS 10046-2021高性能沥青路面施工技术指南
- (高清版)DG∕TJ 08-67-2015 园林绿化草坪建植和养护技术规程
- 海天考研协议书
- 职业学校班主任培训材料
- 《西安市建筑工程安全生产标准化图册(2023版)》
- 2024绿色工业园区评价通则
- 《摩托车和轻便摩托车用电线束总成》
- 美容化妆培训课件生活妆
- DB43-T 2428-2022水利工程管理与保护范围划定技术规范
- 传染病学 06 艾滋病
- 医学生物学试题二(含答案)
评论
0/150
提交评论