版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
A.0.4管桩常用桩型桩身配筋和力学性能表A.0.4-1预应力高强混凝土(PHC)管桩桩身配筋和力学性能见表A.0.4-1。代号外径D壁厚t(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)管桩横截面积Amm2x103配筋率(%)预应力钢棒分布直径dp(mm)保护层厚度mm管桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式或锤击式植入法施工抱压式或锤击式植入法施工PHC30070A7~116Φ7.1240412.5750.60.472302751.62.4811324.151271154494111441726AB6Φ9.03840.762652.22.5086.37B8Φ9.05121.012652.82.5328.19C8Φ10.77201.422553.62.57210.87PHC40095A7~127Φ9.0448412.57910.493083792.95.9162374.3022882778169520583104AB7Φ10.76300.693693.75.9625.87B7~1310Φ10.79000.993694.86.0308.03C13Φ10.711701.293696.06.10010.01PHC500100A7~1411Φ9.0704519.63125.70.5640637128.610.9233274.8431583835233928414286AB7~1511Φ10.79900.7936129.811.0246.59B11Φ12.613751.0935131.511.1608.75C13Φ12.616251.2935132.511.24710.06PHC500125A7~1412Φ9.0768519.63147.30.5240637150.511.7693834.5337014494274133295024AB7~1512Φ10.710800.7336151.811.8786.18B12Φ12.615001.0235153.612.0268.24C15Φ12.618751.2735155.212.1589.93表A.0.4-1PHC桩桩身配筋和力学性能表(1)代号外径D壁厚t(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)管桩横截面积Amm2x103配筋率(%)预应力钢棒分布直径dp(mm)保护层厚度mm管桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式或锤击式植入法施工抱压式或锤击式植入法施工PHC600110A7~1514Φ9.0896519.63169.30.5350637173.118.1924404.6042555167315138275775AB14Φ10.712600.7436174.618.3586.26B14Φ12.617501.0335176.718.5818.34C17Φ12.621251.2535178.318.7519.81PHC600130A7~1516Φ9.01024519.63192.00.5350637196.319.4754994.6348245857357343396546AB16Φ10.714400.7536198.019.6646.31B16Φ12.620001.0435200.419.9198.40C20Φ12.625001.3035202.520.14610.12备注:1.管桩混凝土强度等级为C80,ƒc=35.9N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm2;2.桩身轴心受压承载力设计值未考虑压屈影响;3.混凝土有效预压应力计算值按《先张法预应力混凝土管桩》(GB13476)附录计算;4.预应力钢筋的有效拉应力=σce(A-Aa/Aa);5.桩身受弯承载力设计值按《混凝土结构设计规范》(GB50010)附录计算;6.桩身轴心受压承载力特征值按桩身轴心受压承载力设计值除以1.35计算。表A.0.4-1PHC桩桩身配筋和力学性能表(1)(续表)代号外径D壁厚t(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等直径实心圆截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)截桩部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ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表A.0.4-1PHC桩桩身配筋和力学性能表(2)代号外径D壁厚t(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等直径实心圆截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)截桩部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHC600110A191205277796762365311373226288352245330233332AB22427837510941071378337399230292405B26536549314741488394368430233295457C29542357117501806405388450238300443PHC600130A205225304909870414348398250300351245330233332AB24030641312491224429379429254304405B28540254316831700447414464258308457C32347764420502125462441491265315441备注:1.管桩混凝土强度等级为C80,ƒc=35.9N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm2;2.桩身轴心受压承载力设计值未考虑压屈影响;3.混凝土有效预压应力计算值按《先张法预应力混凝土管桩》(GB13476)附录计算;4.预应力钢筋的有效拉应力=σce(A-Aa/Aa);5.桩身受弯承载力设计值按《混凝土结构设计规范》(GB50010)附录计算;6.填芯混凝土强度等级C30;7.等直径实心圆截面受剪承载力设计值按《混凝土结构设计规范》(GB50010)计算,λ=3;D=300mm时,箍筋采用6,其它采用8;箍筋间距S=200mm,混凝土取C30;8.等直径实心圆截面桩身受弯承载力设计值按全截面配筋率均匀配筋计算,钢筋抗拉强度设计值fy=360N/m2,混凝土取C30。表A.0.4-1PHC桩桩身配筋和力学性能表(2)(续表)A.0.4-2厚壁预应力高强混凝土(PHCtk)管桩桩身配筋和力学性能见表A.0.4-2。表A.0.4-2PHCtk桩桩身配筋和力学性能表代号外径D壁厚t(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)管桩横截面积Amm2x103配筋率(%)预应力钢棒分布直径dp(mm)保护层厚度mm管桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式锤击式植入法施工抱压式或锤击式植入法施工PHCtk400110A7~1210φ7.1400412.57100.170.4029047101.876.1122603.5425173057186422643416AB10φ9.06400.6946102.896.1665.45B7~1310φ10.79000.9045104.06.2247.38C13φ10.711701.1745105.156.2859.23PHCtk500145A7~1412φ9.0768519.63161.630.4838647164.912.1284204.1640624932300836535512AB7~1512φ10.710800.6746166.212.2275.68B12φ12.615000.9345168.012.3607.59C15φ12.618751.1645169.612.4799.18PHCtk600175A7~1516φ9.01024519.63233.540.4748647237.920.9866073.8658697126434752797965AB16φ10.714400.6246239.721.1605.28B16φ12.620000.8645242.121.3957.08C20φ12.625001.0745244.221.6058.58备注:1.管桩混凝土强度等级为C80,ƒc=35.9N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.混凝土有效预压应力计算值按《先张法预应力混凝土管桩》(GB13476)附录计算4.预应力钢筋的有效拉应力=σce(A-Aa/Aa)5.桩身受弯承载力设计值按《混凝土结构设计规范》(GB50010)附录计算6.填芯混凝土强度等级C30表A.0.4-2PHCtk桩桩身配筋和力学性能表(续表)代号外径D壁厚t(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等直径实心圆截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)截桩部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHCtk400110A5855734383362111671811271412791281666693AB7086113604540220189203130144346B83115152835764229207221132146396C951411891053993237224238136150381PHCtk500145A122130172686653346295314216235355183241132188AB142178236944918357322341219238409B16723631512751275371352371222241464C18828237815571594382374393228247449PHCtk600175A205211281918870496406433296323357245330233332AB23729038612651224511441468300327412B27838952017141700530483510304331469C31346662620952125546515542312339455备注:1.管桩混凝土强度等级为C80,ƒc=35.9N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.混凝土有效预压应力计算值按《先张法预应力混凝土管桩》(GB13476)附录计算4.预应力钢筋的有效拉应力=σce(A-Aa/Aa)5.桩身受弯承载力设计值按《混凝土结构设计规范》(GB50010)附录计算6.填芯混凝土强度等级C307.等直径实心圆截面受剪承载力设计值按《混凝土结构设计规范》(GB50010)计算,λ=3;D=300mm时,箍筋采用6,其它采用8;箍筋间距S=200mm,混凝土取C30;8.等直径实心圆截面桩身受弯承载力设计值按全截面配筋率均匀配筋计算,钢筋抗拉强度设计值fy=360N/m2,混凝土取C30。A.0.4-3厚壁预应力超高强混凝土(PHCts)管桩桩身配筋和力学性能见表A.0.4-3。代号外径D壁厚t(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)管桩横截面积Amm2x103配筋率(%)预应力钢棒分布直径dp(mm)保护层厚度mm管桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式锤击式植入法施工抱压式或锤击式植入法施工PHCts400110A7~1210φ7.1400412.57100.170.4029047101.876.1082603.5132463942240429204406AB10φ9.06400.6946102.896.1595.45B7~1310φ10.79000.9045104.06.2157.43C13φ10.711701.1745105.156.2729.31PHCts500145A7~1412φ9.0768519.63161.630.4838647164.912.1164204.1552386360388047117109AB7~1512φ10.710800.6746166.212.2115.70B12φ12.615000.9345168.012.3387.63C15φ12.618751.1645169.612.4529.24PHCts600175A7~1516φ9.01024519.63233.540.4748647237.920.9666073.85586971264347527910272AB16φ10.714400.6246239.721.1325.30B16φ12.620000.8645242.121.3567.11C20φ12.625001.0745244.221.5568.63备注:1.管桩混凝土强度等级为C105,ƒc=46.3N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.混凝土有效预压应力计算值按《先张法预应力混凝土管桩》(GB13476)附录计算4.预应力钢筋的有效拉应力=σce(A-Aa/Aa)5.桩身受弯承载力设计值按《混凝土结构设计规范》(GB50010)附录计算6.填芯混凝土强度等级C30表A.0.4-3PHCts桩桩身配筋和力学性能表代号外径D壁厚t(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等直径实心圆截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)截桩部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHCts400110A6556733573402521872011451592771281666693AB7887114560544260209223147161346B90118155771765269230244150164398C103147194977995278248262154168384PHCts500145A137131173684653411327346245264354183241132188AB157180239944918422356375248267411B18224232112751275436389408251270466C20429238915571594447413432257276452PHCts600175A230213283915870590452479339366356245330233332AB26329439112691224605492519343370414B30439652717181700624537564348375471C34048164121032125640571598355382457备注:1.管桩混凝土强度等级为C105,ƒc=46.3N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.混凝土有效预压应力计算值按《先张法预应力混凝土管桩》(GB13476)附录计算4.预应力钢筋的有效拉应力=σce(A-Aa/Aa)5.桩身受弯承载力设计值按《混凝土结构设计规范》(GB50010)附录计算6.填芯混凝土强度等级C307.等直径实心圆截面受剪承载力设计值按《混凝土结构设计规范》(GB50010)计算,λ=3;D=300mm时,箍筋采用6,其它采用8;箍筋间距S=200mm,混凝土取C30;8.等直径实心圆截面桩身受弯承载力设计值按全截面配筋率均匀配筋计算,钢筋抗拉强度设计值fy=360N/m2,混凝土取C30。表A.0.4-3PHCts桩桩身配筋和力学性能表(续表)A.0.4-4薄壁预应力高强混凝土(PHCtn)管桩桩身配筋和力学性能见表A.0.4-4。代号外径D壁厚t(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)管桩横截面积Amm2x103配筋率(%)预应力钢棒分布直径dp(mm)保护层厚度mm管桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式锤击式植入法施工抱压式或锤击式植入法施工PHCtn30055A≤95φ7.1200412.5742.30.472402243.162.2641104.11106312917879561443PHCtn40065A≤106φ7.1240412.5768.70.353302769.405.0461783.1117182086127215452332AB10-126φ9.03840.562670.015.0884.84PHCtn50065A<108φ7.1320412.5788.780.364302790.158.7142303.1922312709165220063028AB10-148φ9.05120.584402690.978.7904.96备注:1.管桩混凝土强度等级为C80,ƒc=35.6N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.混凝土有效预压应力计算值按《先张法预应力混凝土管桩》(GB13476)附录计算4.预应力钢筋的有效拉应力=σce(A-Aa/Aa)5.桩身受弯承载力设计值按《混凝土结构设计规范》(GB50010)附录计算6.填芯混凝土强度等级C307.本桩型箍筋加密区长度500mm;箍筋加密区间距50±5mm;非加密区间距150±5mm表A.0.4-4PHCtn桩桩身配筋和力学性能表表A.0.4-4PHCtn桩桩身配筋和力学性能表(续表)代号外径D壁厚t(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等直径实心圆截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)截桩部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHCtn30055A232435177170908095627727864852839PHCtn40065A4640592162041431331641101412791281666693AB556291339326148146177111142349PHCtn50065A7969103288272186171230140199279183241132188AB96108157451435193187246142201348备注:1.管桩混凝土强度等级为C80,ƒc=35.6N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.混凝土有效预压应力计算值按《先张法预应力混凝土管桩》(GB13476)附录计算4.预应力钢筋的有效拉应力=σce(A-Aa/Aa)5.桩身受弯承载力设计值按《混凝土结构设计规范》(GB50010)附录计算6.填芯混凝土强度等级C307.本桩型箍筋加密区长度500mm;箍筋加密区间距50±5mm;非加密区间距150±5mm8.等直径实心圆截面受剪承载力设计值按《混凝土结构设计规范》(GB50010)计算,λ=3;D=300mm时,箍筋采用6,其它采用8;箍筋间距S=200mm,混凝土取C30;9.等直径实心圆截面桩身受弯承载力设计值按全截面配筋率均匀配筋计算,钢筋抗拉强度设计值fy=360N/m2,混凝土取C30。A.0.4-5预应力混凝土方箱形截面桩(PHS)桩身配筋和力学性能见表A.0.4.5。代号边长B内径D(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)方桩横截面积Amm2x103配筋率(%)预应力钢棒分布边长Bp(mm)保护层厚度mm方桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式或锤击式植入法施工抱压式或锤击式植入法施工PHS300160A7~108Φ7.1320412.5769.90.462302771.34.3761793.8417562133130115802384AB8Φ9.05120.732672.14.4305.96B8Φ10.77201.032573.04.4898.12PHS350170A7~118Φ9.0512412.5799.80.5125738102.07.0662504.2825083045185822563404AB8Φ10.77200.7237102.97.1295.88B8Φ12.610001.0036104.17.2147.92PHS400220A7~128Φ9.0512412.57122.00.4230738124.210.2853053.5530663722227127574160AB8Φ10.77200.5937125.110.3634.90B8Φ12.610000.8236126.310.4696.64PHS450260A7~1312Φ9.0768412.57149.40.5135738152.714.5173744.3037554559278133775096AB12Φ10.710800.7237154.014.6505.91B12Φ12.615001.0036155.814.8287.97PHS500310A7~1312Φ9.0768519.63174.60.4440737177.819.4024363.7243865326324939455952AB12Φ10.710800.6236179.119.5575.13B12Φ12.615000.8635180.919.7666.94表A.0.4-5PHS桩桩身配筋和力学性能表(1)代号边长B内径D(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)方桩横截面积Amm2x103配筋率(%)预应力钢棒分布边长Bp(mm)保护层厚度mm方桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式或锤击式植入法施工抱压式或锤击式植入法施工PHS550310A7~1416Φ9.01024519.63227.10.4545737231.426.6515683.8157056928422651327743AB16Φ10.714400.6336233.226.8825.25B16Φ12.620000.8835235.627.1947.10PHS600360A7~1520Φ9.01280519.63258.30.5050737263.734.0476464.1664897879480758378806AB20Φ10.718000.7036265.934.3705.73B20Φ12.625000.9735268.934.8057.73备注:1.管桩混凝土强度等级为C80,ƒc=35.6N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.预应力损失及混凝土有效预压应力计算值按《预应力混凝土空心方桩》(JG/T197)有关条文计算4.桩身轴心受压承载力特征值RVK=桩身轴心受压承载力设计值Rp/1.355.单节允许长度最大值为两端勾吊法起吊控制值表A.0.4-5PHS桩桩身配筋和力学性能表(1)(续表)代号边长B内径D(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等边长实心方截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)填芯部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHS300160A1738492742729376876576267851352341AB26607943043510084956677327B3686123593612109921036677376PHS350170A307092436435131107119881013361151844053AB429912960561214011512889101390B5713819782585015112613990102444PHS400220A37801064414351491211421021233411492396483AB51113148613612158130150103124397B69166206838850169141162104124455PHS450260A6213617365765318515017912715633718730198123AB87192243911918197163192129158391B11827439212421275214180209131160446PHS500310A72152193661653224186227162204341230370140176AB100214271919918237199240164205397B13729737612551275254215257166208454表A.0.4-5PHS桩桩身配筋和力学性能表(2)代号边长B内径D(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等边长实心方截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)填芯部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHS550310A101224278881870295241283210252340277447159239AB14131539112231224312259300213254396B19345954216721700335281322216257453PHS600360A14230637810981088331272328233289339328530212267AB19743053115231530352293349236292393B26972173620782125380321376240296448备注:1.管桩混凝土强度等级为C80,ƒc=35.6N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.预应力损失及混凝土有效预压应力计算值按《预应力混凝土空心方桩》(JG/T197)有关条文计算3.桩身填芯受剪承载力设计值=桩身受剪承载力设计值+填芯混凝土抗剪承载力设计值,按C30混凝土填芯计算4.按标准组合计算的开裂弯矩为裂缝控制等级一级时数值5.等边长实心方桩混凝土强度等级为C406.填芯混凝土强度等级C307.等边长实心方桩截面受剪承载力设计值按《混凝土结构设计规范》(GB50010)计算,λ=3;B=300mm时,箍筋采用6,其它采用8;箍筋间距S=200mm;8..等边长实心方桩截面桩身受弯承载力设计值按全截面配筋率均匀配筋计算,钢筋抗拉强度设计值fy=360N/m2。表A.0.4-5PHS桩桩身配筋和力学性能表(2)(续表)A.0.4-6厚壁式高强预应力混凝土方箱形截面桩(PHStk)桩身配筋和力学性能见表A.0.4.6。代号边长B内径D(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)方桩横截面积Amm2x103配筋率(%)预应力钢棒分布边长Bp(mm)保护层厚度mm方桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式或锤击式植入法施工抱压式或锤击式植入法施工PHStk350160A7~118Φ9.0512412.57102.40.5024842104.67.1062664.1725733125190623143492AB8Φ10.77200.7041105.57.1655.74B8Φ12.610000.9840106.77.2447.74PHStk400195A7~118Φ9.0512412.57130.20.3928847132.310.4823393.3432703971242229424438AB8Φ10.77200.5546133.210.5514.61B8Φ12.610000.7745134.410.6446.26PHStk450220A7~1212Φ9.0768412.57164.50.4733847167.814.9694283.9341345019306237185610AB12Φ10.710800.6646169.115.0885.41B12Φ12.615000.9145170.915.2487.31PHStk500240A7~1212Φ9.0768519.63204.80.3838647208.020.5255333.1951466248381246286983AB12Φ10.710800.5346209.420.6654.42B12Φ12.615000.7345211.220.8536.00备注:1.管桩混凝土强度等级为C80,ƒc=35.6N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.预应力损失及混凝土有效预压应力计算值按《预应力混凝土空心方桩》(JG/T197)有关条文计算4.桩身轴心受压承载力特征值RVK=桩身轴心受压承载力设计值Rp/1.355.单节允许长度最大值为两端勾吊法起吊控制值表A.0.4-6PHStk桩桩身配筋和力学性能表(1)代号边长B内径D(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等边长实心方截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)填芯部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHStk350160A307091437435134109120901013371151844053AB4110512960561214311712891102391B5613719582685015412813992103445PHStk400195A35801054424351591281441091253421492396483AB49112147614612168137153110126399B67165204841850179148164111127458PHStk450220A5913517265965320616518614216333918730198123AB82190242915918218178199144165394B11127138712491275235195215146167451PHStk500240A66151192664653268217241193218344230370140176AB91212270924918281230254195220401B12529537412661275298247272197222461备注:1.管桩混凝土强度等级为C80,ƒc=35.6N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.预应力损失及混凝土有效预压应力计算值按《预应力混凝土空心方桩》(JG/T197)有关条文计算3.桩身填芯受剪承载力设计值=桩身受剪承载力设计值+填芯混凝土抗剪承载力设计值,按C30混凝土填芯计算4.按标准组合计算的开裂弯矩为裂缝控制等级一级时数值5.等边长实心方桩混凝土强度等级为C406.填芯混凝土强度等级C307.等边长实心方桩截面受剪承载力设计值按《混凝土结构设计规范》(GB50010)计算,λ=3;B=300mm时,箍筋采用6,其它采用8;箍筋间距S=200mm;8..等边长实心方桩截面桩身受弯承载力设计值按全截面配筋率均匀配筋计算,钢筋抗拉强度设计值fy=360N/m2。表A.0.6-6PHStk桩桩身配筋和力学性能表(2)A.0.4-7厚壁式超高强预应力混凝土方箱形截面桩(PHSts)桩身配筋和力学性能见表A.0.4-7。代号边长B内径D(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)方桩横截面积Amm2x103配筋率(%)预应力钢棒分布边长Bp(mm)保护层厚度mm方桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式或锤击式植入法施工抱压式或锤击式植入法施工PHSts350160A7~128Φ9.0512412.57102.40.5024842104.57.0992664.2233194030245829854504AB8Φ10.77200.7041105.37.1555.83B8Φ12.610000.9840106.57.2307.90PHSts400195A7~128Φ9.0512412.57130.20.3928847132.210.4743393.3742185121312437945724AB8Φ10.77200.5546133.110.5404.67B8Φ12.610000.7745134.210.6286.36PHSts450220A7~1312Φ9.0768412.57164.50.4733847167.614.9554283.9753316473394947957235AB12Φ10.710800.6646168.915.0695.49B12Φ12.615000.9145170.615.2217.45PHSts500240A7~1312Φ9.0768519.63204.80.3838647207.920.5095333.2266368058491659699006AB12Φ10.710800.5346209.120.6424.47B12Φ12.615000.7345210.920.8216.09备注:1.管桩混凝土强度等级为C105,ƒc=46.3N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.预应力损失及混凝土有效预压应力计算值按《预应力混凝土空心方桩》(JG/T197)有关条文计算4.桩身轴心受压承载力特征值RVK=桩身轴心受压承载力设计值Rp/1.355.单节允许长度最大值为两端勾吊法起吊控制值表A.0.4-7PHSts桩桩身配筋和力学性能表(1)`代号边长B内径D(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等边长实心方截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)填芯部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHSts350160A3072944414351531221331041152821151844053AB42107131614612161131142105116329B57142201841850173142153106117377PHSts400195A35821074454351821441611261422861492396483AB49115151621612191153170127143335B68169239853850203165181128144386PHSts450220A5913817766565323518620716518628418730198123AB83195248926918248199220167188332B11328039712711275265217237170191381PHSts500240A66154197669653305243268222246287230370140176AB92217277934918318257281224249336B12730138412841275336274299227251388备注:1.管桩混凝土强度等级为C105,ƒc=46.3N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.预应力损失及混凝土有效预压应力计算值按《预应力混凝土空心方桩》(JG/T197)有关条文计算3.桩身填芯受剪承载力设计值=桩身受剪承载力设计值+填芯混凝土抗剪承载力设计值,按C30混凝土填芯计算4.按标准组合计算的开裂弯矩为裂缝控制等级一级时数值5.等边长实心方桩混凝土强度等级为C406.填芯混凝土强度等级C307.等边长实心方桩截面受剪承载力设计值按《混凝土结构设计规范》(GB50010)计算,λ=3;B=300mm时,箍筋采用6,其它采用8;箍筋间距S=200mm;8..等边长实心方桩截面桩身受弯承载力设计值按全截面配筋率均匀配筋计算,钢筋抗拉强度设计值fy=360N/m2。表A.0.4-7PHSts桩桩身配筋和力学性能表(2)A.0.4-8高强混凝土薄壁空心方箱形截面桩(PHStn)桩身配筋和力学性能见表A.0.4-8。代号边长B内径D(mm)型号桩身配筋构造桩身轴心抗压力学性能单节允许长度L(m)预应力钢棒直径与数量(mm)预应力钢棒面积Aa(mm2)螺旋箍筋直径和面积(mm)(mm2)方桩横截面积Amm2x103配筋率(%)预应力钢棒分布边长Bp(mm)保护层厚度mm方桩截面换算面积A0mm2x103换算截面抵抗矩Wo(mm3x106)理论重量kg/m混凝土有效预压应力σceN/mm2桩身轴心受压承载力设计值Rp≤(kN)桩身轴心受压承载力特征值RVK≤(kN)桩身抱压允许压桩力pjmax≤(KN)抱压式或锤击式植入法施工抱压式或锤击式植入法施工PHStn300170A7~94Φ7.1160412.5767.30.242302768.04.2871752.0416912054125315212295AB4Φ9.02560.382668.44.3233.22备注:1.管桩混凝土强度等级为C80,ƒc=35.6N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.桩身轴心受压承载力设计值未考虑压屈影响3.预应力损失及混凝土有效预压应力计算值按《预应力混凝土空心方桩》(JG/T197)有关条文计算4.桩身轴心受压承载力特征值RVK=桩身轴心受压承载力设计值Rp/1.355.单节允许长度最大值为两端勾吊法起吊控制值表A.0.4-8PHStn桩桩身配筋和力学性能表(1)代号边长B内径D(mm)型号桩身抗弯力学性能桩身抗拉力学性能桩身抗剪力学性能等边长实心方截面桩身力学性能按标准组合计算的开裂弯矩Mk≤(kN.m)桩身受弯承载力设计值Rm≤(kN.m)桩身受弯承载力极限值Mu≤(kN.m)按标准组合计算的开裂拉力Rta≤(kN)桩身轴心受拉承载力设计值Qt≤(kN)按标准组合计算的开裂剪力RV≤(kN)桩身受剪承载力设计值RV≤(kN)桩身填芯受剪承载力设计值RV≤(kN)截桩部位受剪承载力设计值RV≤(kN)填芯部位填芯斜截面受剪承载力设计值RV≤(kN)截桩后桩端预应力传递长度Ltr(mm)桩身受剪承载力设计值[V]≤(kN)桩身受弯承载力设计值M≤(kN.m)N=0N=0.3fcAρ=1%ρ=1.5%PHStn300170A918261391368267796173274851352341AB1430422202188671836174342备注:1.管桩混凝土强度等级为C80,ƒc=35.6N/mm2;预应力钢筋抗拉强度设计值ƒpy=1000N/mm2;箍筋采用乙级冷拔低碳钢丝,抗剪计算时强度设计值ƒyV=320N/mm22.预应力损失及混凝土有效预压应力计算值按《预应力混凝土空心方桩》(JG/T197)有关条文计算3.桩身填芯受剪承载力设计值=桩身受剪承载力设计值+填芯混凝土抗剪承载力设计值,按C30混凝土填芯计算4.按标准组合计算的开裂弯矩为裂缝控制等级一级时数值5.等边长实心方桩混凝土强度等级为C406.填芯混凝土强度等级C307.等边长实心方桩截面受剪承载力设计值按《混凝土结构设计规范》(GB50010)计算,λ=3;B=300mm时,箍筋采用6,其它采用8;箍筋间距S=200mm;8..等边长实心方桩截面桩身受弯承载力设计值按全截面配筋率均匀配筋计算,钢筋抗拉强度设计值fy=360N/m2。表A.0.4-8PHStn桩桩身配筋和力学性能表(2)PAGEPAGE0附录B按桩顶水平位移控制的单桩水平承载力特征值计算表B.0.1当桩的水平承载力由水平位移控制时,PHC管桩可按表B.0.1估算单桩水平承载力特征值。表B.0.1PHC单桩水平承载力特征值估算表(桩顶位移10mm控制)m(MN/m4)α(l/m)桩顶约束情况桩换算埋深(αh)Rha(kN)m(MN/m4)α(l/m)桩顶约束情况桩换算埋深(αh)Rha(kN)PHC-300-AB-70PHC-400-AB-9520.676铰接自由4.011.51020.552铰接自由4.019.9413.010.3033.017.8502.47.9682.413.805固接4.029.890固接4.051.7833.027.3313.047.3502.425.6592.444.45340.776铰接自由4.017.44640.634铰接自由4.030.2253.015.6173.027.0552.412.0782.420.924固接4.045.304固接4.078.4883.041.4263.071.7692.438.8922.467.37860.842铰接自由4.022.25160.688铰接自由4.038.5503.019.9183.034.5062.415.4042.426.687固接4.057.782固接4.0100.1063.052.8363.091.5372.449.6032.485.936100.932铰接自由4.030.232100.762铰接自由4.052.3763.027.0613.046.8822.420.9292.436.259固接4.078.506固接4.0136.0093.071.7863.0124.3672.467.3942.4116.757151.011铰接自由4.038.558150.826铰接自由4.066.8013.034.5153.059.7952.426.6932.446.245固接4.0100.129固接4.0173.4703.091.5583.0158.6202.485.9552.4148.915201.071铰接自由4.045.823200.875铰接自由4.079.3873.041.0173.071.0612.431.7232.454.958固接4.0118.993*固接4.0206.152*3.0108.807*3.0188.504*2.4102.1502.4176.970*251.120铰接自由4.052.398250.915铰接自由4.090.7783.046.9033.081.2572.436.2742.462.844固接4.0136.068*固接4.0235.732*3.0124.420*3.0215.553*2.4116.807*2.4202.364*301.161铰接自由4.058.455300.949铰接自由4.0101.2723.052.3253.090.6502.440.4682.470.109固接4.0151.797*固接4.0262.983*3.0138.803*3.0240.471*2.4130.310*2.4225.757*351.197铰接自由4.064.120350.979铰接自由4.0111.0853.057.3953.099.4352.444.3892.476.903固接4.0166.507*固接4.0288.466*3.0152.253*3.0263.773*2.4142.937*2.4247.633*401.230铰接自由4.069.468401.005铰接自由4.0120.3513.062.1833.0107.7292.448.0922.483.317固接4.0180.396*固接4.0312.529*3.0164.953*3.0285.776*2.4154.860*2.4268.290*451.259铰接自由4.074.555451.029铰接自由4.0129.1643.066.7363.0115.6182.451.6142.489.419固接4.0193.606*固接4.0335.415*3.0177.032*3.0306.702*2.4166.200*2.4287.936*备注:1.m—桩侧土水平抗力系数的比例系数;α—桩的水平变形系数;Rha—单桩水平承载力特征值。2.带*号数值表示单桩水平承载力特征值已超过表A.0.4中桩身受剪承载力设计值。表B.0.1(续表)PHC单桩水平承载力特征值估算表(桩顶位移10mm控制)m(MN/m4)α(l/m)桩顶约束情况桩换算埋深(αh)Rha(kN)m(MN/m4)α(l/m)桩顶约束情况桩换算埋深(αh)Rha(kN)PHC-500-AB-100PHC-500-AB-12520.479铰接自由4.030.10220.472铰接自由4.031.0143.026.9453.027.7622.420.8392.421.471固`接4.078.169固接4.080.5393.071.4773.073.6442.467.1042.469.13840.550铰接自由4.045.62640.542铰接自由4.047.0093.040.8413.042.0792.431.5862.432.544固接4.0118.482固接4.0122.0743.0108.3393.0111.6242.4101.7102.4104.79460.597铰接自由4.058.19260.588铰接自由4.059.9573.052.0893.053.6692.440.2862.441.507固接4.0151.115固接4.0155.6963.0138.1793.0142.3682.4129.7242.4133.657100.661铰接自由4.079.063100.651铰接自由4.081.4603.070.7713.072.9172.454.7342.456.394固接4.0205.312固接4.0211.5373.0187.7373.0193.4292.4176.2502.4181.593150.717铰接自由4.0100.839150.706铰接自由4.0103.8973.090.2643.093.0002.469.8102.471.926固接4.0261.860固接4.0269.8003.0239.4443.0246.7042.4224.7932.4231.609200.760铰接自由4.0119.838200.748铰接自由4.0123.4713.0107.2693.0110.5222.482.9622.485.477固接4.0311.195*固接4.0320.630*3.0284.556*3.0293.1832.4267.145*2.4275.244250.794铰接自由4.0137.033250.782铰接自由4.0141.1873.0122.6613.0126.3802.494.8662.497.742固接4.0355.848*固接4.0366.637*3.0325.386*3.0335.251*2.4305.477*2.4314.738*300.824铰接自由4.0152.874300.811铰接自由4.0157.5093.0136.8413.0140.9902.4105.8322.4109.041固接4.0396.984*固接4.0409.020*3.0363.001*3.0374.007*2.4340.790*2.4351.122*350.849铰接自由4.0167.688350.837铰接自由4.0172.7723.0150.1013.0154.6522.4116.0882.4119.607固接4.0435.453*固接4.0448.655*3.0398.177*3.0410.249*2.4373.814*2.4385.147*400.872铰接自由4.0181.676400.859铰接自由4.0187.1843.0162.6223.0167.5522.4125.7712.4129.585固接4.0471.777*固接4.0486.080*3.0431.391*3.0444.470*2.4404.996*2.4417.274*450.893铰接自由4.0194.979450.880铰接自由4.0200.8903.0174.5303.0179.8222.4134.9812.4139.074固接4.0506.323*固接4.0521.674*3.0462.981*3.0477.017*2.4434.652*2.4447.830*备注:1.m—桩侧土水平抗力系数的比例系数;α—桩的水平变形系数;Rha—单桩水平承载力特征值。2.带*号数值表示单桩水平承载力特征值已超过表A.0.4中桩身受剪承载力设计值。表B.0.1(续表)PHC单桩水平承载力特征值估算表(桩顶位移10mm控制)m(MN/m4)α(l/m)桩顶约束情况桩换算埋深(αh)Rha(kN)m(MN/m4)α(l/m)桩顶约束情况桩换算埋深(αh)Rha(kN)PHC-600-AB-110PHC-600-AB-13020.427铰接自由4.042.50020.421铰接自由4.043.6853.038.0433.039.1042.429.4222.430.243固接4.0110.365固接4.0113.4433.0100.9183.0103.7322.494.7432.497.38440.490铰接自由4.064.41940.484铰接自由4.066.2153.057.6633.059.2702.444.5962.445.839固接4.0167.283固接4.0171.9473.0152.9633.0157.2282.4143.6032.4147.60760.532铰接自由4.082.16160.524铰接自由4.084.4523.073.5443.075.5952.456.8792.458.465固接4.0213.357固接4.0219.3053.0195.0933.0200.5322.4183.1552.4188.262100.589铰接自由4.0111.629100.581铰接自由4.0114.7413.099.9213.0102.7072.477.2792.479.433固接4.0289.878固接4.0297.9603.0265.0643.0272.4542.4248.8452.4255.783150.639铰接自由4.0142.374150.630铰接自由4.0146.3433.0127.4423.0130.9952.498.5632.4101.311固接4.0369.717固接4.0380.0253.0338.0693.0347.4942.4317.3832.4326.232200.676铰接自由4.0169.197200.667铰接自由4.0173.9153.0151.4523.0155.6752.4117.1332.4120.399固接4.0439.373*固接4.0451.623*3.0401.761*3.0412.963*2.
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 湖南省A佳教育湖南G10、H11教育联盟2026年11月高二年级11月期中考试政治+答案
- 2026年网络监控运维员实操考核试题及答案
- 2026年二、试卷征订
- 小学美术9年教龄教育硕士个人发展三年规划
- 小学科学教育学硕士个人发展三年规划
- 植筋专项施工方案
- 四川省德阳市2026届三年级数学下学期期末检测模拟试题(含答案)
- 2026年金融财务考试题库及参考答案
- 2026年新交安安全员c证考试题库及参考答案
- 2026年河南单招职测题库及答案
- 2026年餐饮管理专业知识结构评估试题及答案
- 2026年医疗卫生公基考试题库(附答案)
- 2026初中数学教师课标考试模拟试卷附参考答案三套
- 非法营运案例课件
- 2026年土建主管考试题库及答案
- 理性上网辨别网络谣言 大学生网络文明课件
- 2026-2027学年教科版四年级上册科学第一单元《空气》单元素养测评卷含答案
- 瓶装液化气配送制度规范
- EGFR 20外显子插入突变非小细胞肺癌中国专家共识(2025版)要点解读
- 中华人民共和国治安管理处罚法(2025年修订)学习与解读
- 教育学原理 第二版 课件 第10章 教育科学研究
评论
0/150
提交评论