某综合楼自动喷水灭火系统设计计算过程案例目录TOC\o"1-3"\h\u733某综合楼自动喷水灭火系统设计计算过程案例 1118421.1系统的设计流量计算 1276721.2管道水力计算 1274441.3减压措施 81.1系统的设计流量计算喷头流量按下式计算:公式(3-11)式中:工作压力P;流量系数K。1.2管道水力计算(1)沿程水头损失公式(3-12)(2)局损采用当量长度法。(3)水泵扬程公式(3-13)(4)压力最难满足的点处作用面积选取和水力计算1)中危险级Ⅰ级区域压力最难满足的点处位于十二层,截取面积为178.51m2>160m2。图3-16压力最难满足的点计算图(十二层)表3-13自动喷水灭火计算表(十二层)管段编号总水头损失
(mH2O)q
(L/s)当量长度(m)L
(m)Kiv(m/s)DN
(mm)终点压力(mH2O)1-20.531.110.601.93802.071.90257.532-30.151.110.200.52802.071.90257.693-40.592.281.800.85802.202.31328.284-50.732.280.902.35802.202.31329.0113-50.291.240.800.30802.542.12259.045-61.503.522.100.90804.923.573210.5114-61.071.290.902.95802.722.202510.476-71.694.812.701.30804.143.594012.2015-70.441.441.000.30803.342.462512.207-81.366.253.103.40802.052.865013.5616-171.141.430.802.60803.282.442512.6718-81.131.481.002.15803.532.532513.6019-170.391.470.800.30803.472.512512.64续表3-13管段编号总水头损失
(mH2O)q
(L/s)当量长度(m)L
(m)Kiv
(m/s)DN
(mm)终点压力(mH2O)17-80.892.902.250.30803.432.943213.568-92.2910.633.850.25805.474.875015.8520-210.861.210.802.70802.412.06259.1021-220.612.471.800.55802.562.51329.7225-220.781.260.802.15802.602.15259.7522-232.683.732.252.55805.483.793212.4026-271.061.350.802.70802.982.312511.4527-230.912.782.250.55803.172.823212.3628-231.041.421.002.15803.242.422512.4223-241.997.923.602.55803.183.635014.3929-301.221.460.802.70803.432.492513.3130-241.102.992.400.55803.653.043214.4131-241.201.531.002.15803.732.612514.4324-91.4512.444.302.45802.103.426515.849-102.4723.074.603.90802.854.498018.3132-330.261.310.600.32802.792.23259.9333-340.911.310.802.40802.792.232510.8437-340.351.360.800.32803.012.332510.8534-351.342.671.802.65802.952.713212.1735-363.614.132.103.25806.624.203215.7938-360.501.640.900.25804.262.812515.8136-102.525.783.001.25805.814.314018.3010-114.4428.844.605.50804.315.618022.7539-401.381.850.801.75805.303.162520.7441-401.381.850.801.75805.303.162520.7440-112.013.702.401.25805.393.763222.7511-124.0232.544.602.73805.386.338026.77位于十二层选取的面积中,压力最难满足的点处所需压力为0.2677MPa,流量为32.54L/s。危险级为中危险级Ⅱ级,截取面积为161.23m2>160m2。图3-17压力最难满足的点计算图(负一楼)表3-14自动喷水灭火计算表(负一楼)管段编号总水头损失
(mH2O)q
(L/s)当量长度(m)L
(m)Kiv
(m/s)DN
(mm)终点压力(mH2O)1-20.671.110.802.40802.071.90257.672-30.602.271.800.87802.202.31328.2711-30.541.170.801.53802.282.00258.313-41.593.452.251.05804.733.50329.8712-130.841.200.802.65802.392.06259.0513-40.822.472.250.92802.552.51329.8714-40.741.271.001.73802.642.17259.874-51.807.183.603.05802.653.295011.6615-160.981.310.802.65802.792.232510.6616-51.012.682.400.92802.972.723211.6717-50.861.381.001.73803.102.362511.69续表3-14管段编号总水头损失
(mH2O)q
(L/s)当量长度(m)L
(m)iKv
(m/s)DN
(mm)终点压力(mH2O)5-60.8711.243.701.201.74803.096512.5318-190.981.360.802.403.01802.332511.4819-61.062.782.400.873.19802.833212.5520-60.861.441.001.533.33802.452512.566-72.2015.464.302.553.14804.246514.7321-221.191.470.802.553.47802.512513.4422-71.303.012.401.073.68803.063214.7423-70.981.561.001.483.87802.662514.767-81.8120.036.201.902.19803.908016.5424-250.681.110.802.402.07801.90257.7025-260.732.281.801.472.20802.31328.4331-260.411.190.800.932.34802.03258.4026-271.613.462.251.054.78803.523210.0432-330.831.210.802.552.42802.07259.1433-270.872.482.251.072.58802.523210.0134-270.681.281.001.482.70802.192510.0327-281.797.233.602.952.69803.315011.8335-360.971.320.802.552.83802.252510.8136-281.072.702.401.073.01802.743211.8837-280.801.401.001.483.15802.382511.8428-290.9011.323.701.301.77803.116512.7338-390.981.360.802.403.01802.332511.4839-291.262.782.401.473.19802.833212.7440-290.671.461.000.933.41802.492512.7029-302.1315.574.302.253.18804.276514.8641-421.201.480.802.553.50802.522513.5542-301.323.022.401.073.72803.073214.8743-300.991.571.001.483.90802.672514.8830-81.6820.156.201.202.22803.928016.548-90.3340.189.201.960.29802.0215016.88续表3-14管段编号总水头损失
(mH2O)q
(L/s)当量长度(m)L
(m)Kiv
(m/s)DN
(mm)终点压力(mH2O)9-100.2440.184.303.84800.292.0215017.12位于负一楼选取的面积中,压力最难满足的点所需压力为0.1711MPa,流量40.18L/s。(5)水力计算校核1)本建筑十二层工作压力最难满足的喷头压力P=0.07MPa,喷头流量:计算平均喷水强度为:q=32.54×60/178.51=10.94L/(min·m2)>6L(min·m2)2)本建筑负一楼工作压力最难满足的喷头压力P=0.07MPa,喷头流量:计算平均喷水强度为:q=40.18×60/161.23=14.95L/(min·m2)>8L(min·m2)(6)自动喷水灭火系统压力计算1)中危Ⅰ级压力最难满足的点处压力计算①距离泵的长度为77.62m,取DN80,则:i=6.05(qi=6.05(qg1.85×Ch-1.85×dj-4.87)×107=0.3351(kPa/m)h=iL=0.3351×h=iL=0.3351×77.62=0.0260MPa34.55③局损按沿程水头损失的10%计,水流指示器和湿式报警阀水损分别取0.02MPa和0.04MPa,总损失为:Σh=1.1×0.0260+0.04+0.02=0.0886MPaΣh=1.1×0.0260+0.04+0.02=0.0886MPa34.55⑤系统到入口管水平中心线的高差Z=0.4750MPa。⑥则所需水泵扬程为:H=Σh+P0+Z=0.0886+0.07+0.4750=0.6336MPa34.55H=Σh+P0+Z=0.0886+0.07+0.4750=0.6336MPa34.55①距离泵的长度为53.73m,取DN150,则:i=6.05(qi=6.05(qg1.85×Ch-1.85×dj-4.87)×107=0.2019(kPa/m)h=iL=0.2019×h=iL=0.2019×53.73=0.0108MPa34.55Σh=1.1Σh=1.1×0.0108+0.04+0.02=0.0719MPa34.55④喷头工作压力P0=0.07MPa⑤系统到入口管水平中心线的高差Z=0.0399MPa。H=Σh+PH=Σh+P0+Z=0.0719+0.07+0.0399=0.1818MPa34.55(7)自动喷水灭火系统加压泵选用负一楼的消防泵房内所设置的加压泵共有两台,包含一台用作备用的加压泵,单台:XBD8/40-W150,180m3/h,H=99m,N=75KW,n=1480r/min,(运行工况Q=0m3/h,H=127m;Q=126m3/h,H=110m;Q=270m3/h,H=66m),当出现系统压力大于0.96MPa的情况时,将自动开启泄压阀,消防水池将接收泄压后产生
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 平潭县消防救援大队招聘政府专职消防员考试真题2025
- 2026年小学六年级语文第二学期期末考试卷及答案(二十)
- 2026年防范非法集资知识竞赛试卷及答案(共十六套)
- 神经影像弥散张量成像(DTI)
- 模板:六年级语文常规正式教案
- 社工如何持续跟踪和评估服务对象的变化和进展
- 嵌入式天线系统全球前18强生产商排名及市场份额(by QYResearch)
- 译林版英语四年级下册Unit 6Jobs 课时作业一
- 任务4.4混凝土梁运输与架设
- (2026版)医院内部采购监督制度范本
- 主生产计划(MPS)编制案例
- 皮质醇增多症患者的麻醉管理
- 沧州交通学院《智能制造专业英语》2023-2024学年第二学期期末试卷
- (高清版)DB62∕T 4704-2023 医养结合机构基本服务规范
- 可信数据空间解决方案星环科技
- 2025中国建设银行的贷款合同范本
- 项目经理讲安全课件
- 酒店妆容培训
- 第一章体育与健康基础知识 第一节 科学发展体能 课件 2024-2025学年人教版初中体育与健康八年级全一册
- 2025年浙江宁波市粮食收储有限公司招聘笔试参考题库含答案解析
- 二零二五年度高校毕业生论文保密及知识产权保护协议3篇
评论
0/150
提交评论