浙江金港小区燃气管网设计摘要:随着生活水平的不断提高,城市化进程的脚步越来越快;使居民对生活环境以及生活条件要求越来越高的情况下。燃气成为人们经济便捷、环保清洁的生活保障,其具有高效率使用安全等优点使燃气已然是城市家庭不可缺少的基本设施。在城镇中,除了工商业,小区是最具代表的燃气使用区域。本设计小区位于浙江,针对该小区进行燃气官网的设计与规划;该设计采用凝析气田气为气源,选取气密性好,管内壁平滑、成本低且卫生无毒;还能节省防腐成本的PE管作为管材。根据用户需求用气量、以及经济安全的情况下,对该小区进行燃气管网设计。关键词:天然气;金港小区;燃气管网;用气需求Design
of
gas
pipe
network
in
jingang
community,
zhejiangAbstract:Withthecontinuousimprovementoflivingstandard,thepeaceofurbanizationisgettingfaster.Makeresidentslivingenviromentandlivingconditionsincreasinglyhighrequiremengts.Gashasbecomepeople’seconomicconvenience,environmentalprotection,clean,efficientuseofsafetyandotheradvantagessothatgashasbecomeanindispensablebasicfailitiesforurbanfamilies.Inthetown,apartfromtheindustryandcommerce,thecommunityisthemostrepresentativegasusearea.Thisdesigncommunityislocatedinzhejiangprovince,forthecommunitytocarryoutthedesignandplanningoftheofficialgaswebsite;ThedesignUSESgasfromcondensategasfieldasthegassource,withgoodairtightness,smoothinnerwall,lowcostandnontoxicsanitation.CanalsosavethecostofcorrosinasaPEpipe.Accordingtothedemandofusersandeconomicsecurity,thegasnetworkdesignofthecommunityiscarriedout.Keywords:naturalgas,jingangcommunity,gaspipenet,gasdemand目录1.绪论 11.1浙江省地理位置 11.2自然和社会经济发展条件 11.3天然气市场现状 11.4城市燃气需求量统计 11.5燃气供需矛盾即解决办法 22.原始资料 32.1气源资料 32.2燃气用户情况 33.燃气物化性质的计算 43.1本设计中燃气的基本性质 43.2平均分子量 53.3密度 53.4黏度 63.5燃气的低发热值 73.6华白指数 73.7爆炸极限 74.燃气负荷的计算 84.1燃气输配对象 84.2用户用气量的确定 84.3小区管道设计 94.4城镇燃气用气负荷及分类 124.5调压设备选择 135.小区室外燃气管网水力计算 155.1管段阻力损失的计算 155.2确定允许压力降 195.3校核 195.4举例对管道进行水力计算并核算小区管段总压力降 205.5庭院各管段水力计算表 256.燃气负荷的计算 306.1燃气室内布置依据 306.2水力计算 306.3室内各管段计算表 35设计总结 40参考文献 42致谢 43绪论1.1浙江省地理位置浙江省地处亚热带季风气候区;资源丰富、风景宜人,有许多的名胜古迹,比如闻名中外的杭州西湖;西溪国家湿地公园、西塘古镇等等。雨水充沛、地处平原,所以形成了许多的河流,也因为区域条件形成了很多的古镇、江南水乡;比如宋代戴立元的《东篱湖州泊南浔》中的“张帆出东郭、沽酒问南浔”的南浔古镇、还有著名文学大师矛盾的故乡、浙江乌镇;以及刚才所说的西塘古镇。除了古镇之外,享受“七山一水二分田”的美誉;所谓山河湖海无一不有。浙江省四季分明、空气湿润、雨热季节同步;综合以上,浙江省是一个集多种区位形式的一个省市,这也造就了它得天独厚的地理位置;为他的经济建设,提供了不少有利的地理位置条件。交通发达、雨水充沛;在农业、工业、服务业都有很多的良好基础;使之的经济实力在全国都名列前茅;使其经济实力在全国都名列前茅,与江苏、上海并称江浙沪。1.2自然和社会经济发展条件提起《鱼米之乡》大多数人都会想到浙江省;其产的茶叶、大米、蚕茧、竹品都在祖国占重要地位。蚕茧、绿茶在的产量在国内都是数一数二的。浙江因为临海、其使中国的渔业大省,水产品丰富、应有尽有;渔业业从最初的传统生产到如今的、养殖、捕捞、加工一体化。中国最早的四大中心渔港、浙江所占一半,海洋捕捞局中国之首。当然在生物资源方面,浙江省还有一个美誉,那就是“东南植物宝库”之称。森林覆盖率为省面积的60.5%;除了植被,还有许多种类的野生动物。在其他方面,浙江省矿产资源丰富且种类繁多除了常见的矿产资源,还有许多的稀有矿产资源;像辉绿岩、莹石矿的储量都居中国第二。其在海洋方面,资源格外的丰富,它的海岸线占中国的20.3%,其面积不大,但是沿海面积广。所以渔业、港口、旅游、油气资源得天独厚;其海域辽阔、水质肥沃、气候宜人温和。生物种类繁多。浙江省地理特征丰富,无论是从哪一方面都为经济发展提供了良好的先天条件,使其的经济发展迅速、稳定;还能再固有且发展的产业中开发出新的产业。水资源、土地资源、矿物资源以及能源资源都让浙江省成为经济发展的高光区。1.3天然气市场现状浙江的拥有良好的先天条件,使其的产业链丰富且稳定;除了固有的天然资源,在发展经济的快车道上,还是存在能源资源不够。很明显的一个就是在省内的的区域条件下,成煤地质条件差,煤炭资源缺乏;虽然海域油气有不错的前景,但是陆地尚未发现油气资源;在这种情况下,只能对外依存。能源消费的话多以煤炭和石油为主;能源的压力和发展经济所产生的环境压力是浙江省得反正有了一定的影响,而天然气作为当下的一种快捷高效清洁的优质能源;被全世界的人广泛使用;对于能源缺乏的浙江省来说,这无疑是一个新的能源结构;所以正大力引进天然气,提高天然气的利用率;而且国家还有相关的天然气政策,比如“西气东输”等举措。这样浙江省得能源得到保障,而且对环境保护、产业升级起到很好的积极作用。1.4城市燃气需求量统计表1-1居民生活天然气用气量指标(亿立方米/户*年)年份2009年2015年用气量19.054798表1-2规划人口及户数年份20018年2019年规划区总人口(万人)57375850规划区总户数(万户)19111940表1-3居民燃气普及率年份20052017居民燃气普及率83.86%96.26%燃气用气人口(万人)2585.84104.51.5燃气供需矛盾及解决办法浙江省天能源应用有很大的需求,目前情况是供不应求;市场局限于特定的地区;省内存在很大的地区因地使用的普遍现象;而且在工业方面、生活方面;用气严重不足。在为保障天然气的供应保障能力,浙江省人民政府办公厅于17年年末关于浙江省天然气发展三年行动的计划,从2018年到2020年。通过这三年实现保障有力、价格平稳、高效安全的天然气用气体系;且要对居民区域性使用天然气做出改变,提高天然气用气普及。且要建设好天然气的管网建设,加大全省的天然气供气格局;还要从大到小建立城镇的配气管网建设。积极建设城乡天然气管网,开展村村通示范点。在推进天然气的体制革命,还需要建立公平开放的机制,不仅加强政府支持、加快项目建设、也需要加强监督考核,确保工作落到实处、取得良好的效果;解决当下的天然气供需矛盾。2原始资料2.1气源资料表2-1燃气组分表燃气CH4C3H8C4H10CmHnCO2N2凝析气田气74.36.751.8714.911.620.55地点:浙江气源参数:凝析气田气2.2燃气用户情况a)气化站燃气出口压力:表压力0.2MPab)居民用户耗气指标(3000MJ/(人·a))气化率95%3燃气物化性质的计算3.1本设计中燃气的基本性质各种混合燃气的特性是通过对其组分的单一气体进行计算而得出的,下表为设计中使用的天然气凝析气田气的各组分在标准状态下的主要物理热力特性值。表3-2各组分气体基本性质汇总表组分名称甲烷丙烷正丁烷丙烯二氧化碳氮气体积分数(%)74.36.751.8714.911.620.55分子式CH4C3H8C4H10CmHnCO2N2分子量M16.04344.09758.12442.08144.009828.014摩尔容积VM22.362121.936221.503621.9922.260122.403密度ρ0.71742.01022.7031.91361.97711.2504相对密度S(空气=1)0.55481.5542.091.479————气体常数R517.1184.5137.2193.8188.74296.66临界温度TC191.05368.85425.95364.75304.2126.2临界压力PC4.64074.39753.61734.76237.38663.3944临界密度ρC
162226225232468.19310.91高热值Hh39.842101.266133.88693.667————低热值HL35.90293.24123.64987.667————爆炸上限Lh(体积%)159.58.511.7————爆炸下限LL(体积%)52.11.52————组分名称甲烷丙烷正丁烷丙烯二氧化碳氮气动力黏度10.3957.5026.8357.64914.02316.671运动黏度14.53.812.533.997.0913.3无因次系数C164278377321266112沸点t(℃)-161.49-42.05-0.5-47.72-78.2-195.78定压比热CP1.5452.964.132.6751.621.302绝热指数K1.3091.1611.1441.171.3041.402导热系数λ0.030240.015120.013490.014670.013720.02489[273.15K、101325Pa]3.2平均分子量利用下列计算公式算出混合气体的平均分子量:M=r1M1+r2M2…+rnMn=1/100×(16.043×74.3+44.097×6.75+58.124×1.87+42.081×14.91+44.0098×1.62+28.014×0.55=23.1式中:M——混合气体平均分子量。计算得到M=23.13.3密度3.3.1平均密度=1/100×(0.7174×74.3+2.0102×6.75+2.703×1.87+1.9136×14.91+1.9771×1.62+1.2504×0.55)=1.04kg/m3式中::混合气体的平均密度,kg/m3;:燃气中各单一气体的容积比,%;:各单一气体在标准状态下的密度,kg/m3。3.3.2相对密度=1.04/1.293=0.80式中::混合气体的相对密度,空气为1;:混合气体的平均密度,kg/m3;1.293:标准状态下空气的密度,kg/m3。3.4黏度3.4.1运动黏度首先计算各组分的分子量:gCH4=16.043×74.3/23.1=0.516gC3H8=44.097×0.0675/23.1=0.128gC4H10=58.124×0.0187/23.1=0.047gCmHn=42.081×0.1491/23.1=0.272Gco2=44.010×0.0162/23.1=0.031gN2=28.014×0.0055/23.1=0.006gCH4+gC4H10+gC4H10+gCmHn+Gco2+gN2=1=100×10^-6/0.516/10.395+0.128/7.502+0.047/6.835+0.272/7.649+0.031/14.023+0.006/16.671)=8.96×10^-6Pa·s:混合气体的动力粘度,:混合气体各组分的质量成分,%;:混合气体各组分的动力粘度,。3.4.2运动粘度=8.96×10^-6/1.04=8.62×10^-6:流体的运动粘度,m2/s;:相应流体的动力粘度,;:流体的密度,kg/m3。3.5燃气的低发热值该燃气为凝析气田气,查《建筑燃气设计手册》得凝析气田气的低发热值为48358KJ/m3在本设计中的CmHn使用燃气的性质。3.6华白指数QH=(74.3×39752+6.75×101039+1.87×133580+14.91×93456)/100=52788KJ/m3W=QH/=52788/=59018KJ/m33.7爆炸极限可燃成分的爆炸极限L下=100/(74.3/5+6.75/2.1+1.87/1.5+14.91/2.0)=3.73%L上=100/(74.3/15+6.75/9.5+1.87/8.5+14.91/11.7)=13.97%含惰性气体后的爆炸极限L’下=3.73×(1+0.0217/0.9783)×100100+3.73×0.0217/0.9783=3.89%L’上=13.97×(1+0.0217/0.9783)×100100+13.97×0.0217/0.9783=14.54%4燃气负荷的计算4.1燃气输配对象该金港小区是位于浙江省内的小区;其地理位置身处平原,所以在小区内地势平坦;此次的燃气设计所设计的小区楼栋除去11#的小区杂物间,其余有13栋楼层进行燃气输送。各楼栋户数见下表:表4.1各楼栋居民户数分配情况表楼栋1#楼2#楼3#楼4#楼5#楼6#楼7#楼合计户数28282432282816350楼栋8#楼9#楼10#楼12#楼13#楼14#楼户数1632284224244.2用户用气量确定该小区总户数350户,每户燃气灶和热水器的总功率:1.8kw1.居民生活用气量为:Qy=0.95(气化率)×350(户数)×3.5(每户平均人数)×3000(生活用气量标准)/48.36(燃气热值)=72193m³/a2.用同时工作系数法,按计算月的高峰时小时最大用气量来计算燃气管的流量Q=KtΣKQnN==68.5m3/h式中:Q燃气管中的计算流量(m3/h);Kt不同类型用户的同时工作系数,当缺乏资料时,可取Kt=1;N、K、Qn分别是相同燃具或相同组合燃具的数量、同时工作系数和额定流量(m3/h)4.3小区管道设计4.3.1小区管道选材城市室外天然气输配应考虑到用户终端,根据输配的压力要求;进行输配管材的选取。铸铁管在低中压管道中使用较为普遍,高压或次高压一般使用钢管比较适宜。我国的燃气管道根据其压力的不同,可以将按燃气设计压力P(MPa)分为以下表中的七级。4.2压力分级表(燃气设计)名称压力(MPa)高压燃气管道A2.5<P≤4.0B1.6<P≤2.5次高压燃气管道A0.8<P≤1.6B0.4<P≤0.8中压燃气管道A0.2<P≤0.4B0.01≤P≤0.2低压燃气管道P<0.01燃气管网输入到用户,最重要的就是在输配过程中的输送管材;可以用来输送燃气的管材种类繁多,但是不可以随意使用;必须要根据燃气的性质,使用的压力范围、还有要根据施工要求等一系列要求来选用管材。并且还要满足一些基本的要求,比如:要有良好的抗震及气密性,抗腐蚀、还要满足一定的机械强度。而常见的管材有钢管、聚乙烯管、铸铁管等;各有各的优缺点,所以个适用于不同的压力等级、设计范围。钢管本身可塑性好、安装方便、承载应力大;但一般需进行可靠的防腐措施,延长其使用寿命。聚乙烯管又称为PE管,是定当下使用广泛的一种新型管材,其具有耐腐蚀、流体流动的阻力小、本身质轻、使用的寿命也长、费用低、施工简单便捷的一系列优点。使之成为各国大力发展天然气以来的常用管材。铸铁管的抗腐能很强,便于切割和钻孔。其综合性能都不如钢管好,所以也将进行自身不足的改善,提高自己的利用率。根据以上常见的管材优缺点,在结合本设计中的小区位置,压力范围,管网敷使用等一些了综合因素。小区位于平原区域,压力为中低压;小区的燃气输送管道一般埋地敷设;所以管材容易受到腐蚀,地下埋设及管材不容易受到损坏、碰撞。综合以上的情况分析,在本次的设计中使用耐腐蚀、容易安装、流体流动阻力小的聚乙烯(PE)管。查阅资料根据PE管材的长期液压强度可分为PE80的中密度的聚乙烯和高密度的聚乙烯PE100;词设计为小区,选择PE80,。中密度的PE管又分为SDR11和SDR17.6两种。SDR为公称外径与壁厚之比。本设计的燃气种类为凝析气田气,考虑到今后可能会根据使用的情况更换燃气的种类,故选择使用SDR11的聚乙烯的燃气管材。随着塑料管的广泛应用,它的连接方式也越来简单便捷和多样化;聚乙烯管道通常使用的连接方式为热熔连接、电熔连接。4.3.2燃气管网布线在小区地处平原区域,且为生活小区,故小区内没有河流或厂区;所以管网采用埋地进行敷设。而地下燃气管道一般沿道路敷设,则将管道敷设在人行便道或绿化带内。本设计为十三栋居民楼供应燃气,由小区的平面图可以确定使用枝状管网进行布置。(一)布线原则应考虑:管道输配到的终端(用户)燃气在管道输配中的压力;了解街道地下是否有其他管网,有了解其密集程度与布置情况;路面结构的情况、交通运行以及运输干线的分布情况;输送过程中燃气的含湿量的多少,管道坡度是则需要根据输送的燃气性质进行考虑,一般输送燃气需考虑,输送干燃气则不用考虑。地下埋设会由于地质条件,施工情况所遇到的障碍物情况;考虑区域的土壤性质、埋设的腐蚀情况和冰冻线深度;该管道除非正常情况使用下,对人民起居的影响。低压管网的燃气布置直接向各类用户配气是低压管网的主要功能,其在燃气布置时一般应考虑:低压燃气管网的输气压力和沿程压力降得允许值都不高,故每环的边长一般在300m到600m之间。为确保和提高低压管网的供气可靠性,给低压管网供气的相邻调压站之间的管道应该以环状管网布置。直接输配的用户的低压管网;在有条件时需尽可能的将管网布置在街坊内同作为庭院管道,以节省投资。低压干管一般不设置阀门,检修或处理故障时可以使用橡胶球堵塞管道,低压管道。通常一般仅将阀门在调压室出口表4.3地下燃气管与建筑物之间的最小水平净距项目低压中压BA建筑物的基础0.71.01.5给水管0.50.50.5排水管1.01.21.2电力电缆0.50.50.5通讯电缆直埋0.50.50.5在导管内1.01.01.0其它燃气管道Dg<300mm0.40.40.4Dg>300mm0.50.50.5热力管直埋1.01.01.0在导管内1.01.51.5电杆的基础<35KV1.01.01.0>35KV5.05.05.0通讯照明电杆1.01.02.0铁路钢轨5.05.05.0有轨电车的钢轨2.02.02.0街树1.21.21.24.3.3该小区室外燃气管道布置(一)管线绘制:1.首先绘制室外平面图、画出用户、以及管线位置、调压站等2.对各节点进行编号,在有管径、计算流量、气流方向改变或变化的位置按所定的顺序编上接点号。3.在图中标出管道附件的地坪及埋地的标高。4.图上应标示出燃气流动的方向,以及坡度方向。5.图中应将和管网设计有关的建(构)筑物名称表示出来,如调压站。(二)纵断面管道布置地下燃气管道与构筑物和相邻管道之间的垂直净距(m)也有一定要求。因为为新建小区,未给出其他管线布置则本设计暂时先不考虑与其他管线的间距问题,但会给其他管线布置留下适当空间。要求:1.埋设在车行道下时,不允许小于0.9m;2.埋设在非车行道(包括人行道)下时,不允许小于0.6m;3.埋设在庭院(指绿化地及货载汽车不能进入之地)内时,不得小于0.3m;由于地下燃气管道中不可避免有冷凝水或轻质油,为了排除液体,须在管道低处设置排水器,设置相邻排水器两两的距离一般不大于500m,管道应有不小于0.003的坡度,本设计取用0.005。布线时应尽量使管道坡度与地面坡度方向一致,以减少土方量。本设计地面坡度未给出,则取坡度为0。4.4城镇燃气用气负荷定义及分类燃气负荷的含义比较广泛。燃气系统所输送到的用户对天然气的需求,即为在燃气系统中最基本的负荷,即燃气用气负荷,简称作燃气负荷。在设计计算工程中,最根本的资料就是负荷数据,本次工程设计也不除外。燃气系统设计中,燃气负荷数据对设备选择、容量大小、如何合理施工安装、、进行项目规划、运行和调整、技术分析都具有极其重要的的意义。进行城市天然气管网管道设计时,首先要先确定天然气的用气负荷,这是确立气源的位置,设备和管网是否能够承载以及是否具有通过的能力。燃气用气按供给的对象可分为:a)小区居民用于食宿、生活的用气;称为生活用气。b)指学校、宾馆、商业用户、餐饮、医院等用气;称作商业用气c)把燃气作为原料或燃料用于工业企业生产过程中,称之为工业企业用气。d)室内采暖、通风的用气。e)汽车用燃气作为动力能源的的燃气;称为燃气汽车用气。f)电站用气。在某些发电站利用用城镇燃气发电或者供热。即为电站用气电站用气。本设计的供给对象是居民小区,所以只考虑居民的生活用气4.5调压设备选择调压室的主要构成设备是调压器,调压器通常可分为直接作用式和间接作用式两种。为保证调压器的正常运行,一般设有过滤器,套筒,安全阀或安全水封、放散管、专用管、进出口阀门以及压力检测仪表等设备。调压计量室则还设有计量装置。调压室室内工艺布置应考虑以下要求:1.中、低压调压室应设有安全水封,高中压调压室用设置安全阀。2.调压室的内的放散管在被顺引出室外的情况下,那需要满足高出建筑物顶部2米以上。3.调压室必须设有管径比调压器进口管径小一到二级的弯通道,4.在弯通管上应设有安全阀门,可采用闸阀或者截止阀。5.一般在调压器前设置闸阀,控制压力降。6.一般会在调压室外墙10-15的地上阀门的进出口管道上设置阀门,一般使用闸阀,7.一般安装一台调压器在中低压调压室。8.可将备用调压器设置在重要的用户调压室内。此设计选择FQ调压器,其广泛应用于民用小区楼调压及小型公寓设施;FQ调压器产品特点:
1、FQ系列调压器性能优良、造价低、维修安装极其方便。信号管为内置式的模块化结构设计;使其高效、可靠。2、拥有超压会自动切断的安全保障。
3、下图为FQ系列调压器的主要结构。
4、该调压器还可配置成单路旁通(1+1)、双路加旁通(2+1)柜式调压系统。本设计中燃气进口为中压0.2MPa,出口为3000Pa,处于临界状态,只需进行密度修正。标况下空气密度为1.293kg/m3,燃气密度为0.75kg/mQUOTE=0.5QQUOTE=101.64(m3/h)能够满足正常供气要求,设计选RTZ-31/80FQ型的调压器。5:小区室外燃气管网水力计算5.1管段阻力损失的计算5.1.1计算管道计算流量城市燃气输配系统重点在于输配对象使用的情况,以及管网在输送过程中管径的确定,需要根据燃气用具的使用量,来合理的选出合适的管径输送到用户;且输送过程要经济安全合理。而根据燃具、使用人数来确定燃气计算流量是后面水力计算的关键,一般确定燃气小时计算流量的方法有两种,不均匀系数法和同时工作系数法。由于居民住宅使用燃气的数量和使用时间变化较大,故庭院燃气管道的计算流量一般按燃气用具的额定耗气量和同时工作系数来确定。用同时工作系数法求管道计算流量的公式如下:式中::燃气管道的小时计算流量();:不同类型用户的同时工作系数,取1;:相同燃具或相同组合燃具的同时工作系数;:相同燃具或相同组合燃具的额定流量();:相同燃具或相同组合燃具数。可查表查得居民生活用燃具的同时工作系数k。5.1.2预选管径预选管径有平均压降法或经济流速法这两种方法来进行预选。在该设计的庭院管段流量变化频繁,即选用合适设计的经济流速法;以天然气按照6m/s的经济流速预选管径。公式如下:式中::管段的计算流量();:管道内径();:经济流速()。算出预选管径后,可从下表中确定管道内径。表5.1(埋地用聚乙烯PE直管尺寸表)内径(mm)最小壁厚 (mm)公称外径(mm)9.03.01514.03.02019.03.02526.03.03232.63.74040.84.65051.45.86361.46.8755.1.3确定管道的实际流速根据计算流量以及预选管道的内径,由下列公式确定实际流速。式中::实际流速();:庭院及室内燃气管道的计算流量();:管道内径()。5.1.4确定燃气摩擦阻力系数及单位管长摩擦阻力损失燃气处于各种流态时,需要选用不同的阻力计算公式。流态是通过雷诺数来判别的。通过下列公式计算出雷诺数: 式中::雷诺数;:管道内径();:实际流速();:运动粘度(㎡/s)(根据上面计算得v=0.00000862)各管段燃气的雷诺数的不同,将从以下三个区间选择对应的摩擦阻力系数及单位管长的摩擦阻力的公式进行计算;当<2100时为层流;当>3500时为紊流;当21003500时为临界状态;式中::燃气管道摩擦阻力损失(Pa);:燃气管道的摩阻系数;:燃气管道的计算长度(m);:燃气管道的计算流量(Nm3/h);:管道内径(mm);:1㎏/m;:运动粘度(㎡/s);:管壁内表面的当量绝对粗糙度(mm)。PE管一般取=0.01mm【1】;:雷诺数;:实际的燃气温度,本设计取当地年平均气温16度;:273K。5.1.5单位管长摩擦阻力损失的密度修正在使用上述单位管长摩擦阻力损失的公式后,通过下列公式进行密度修正。密度为1kg/m3在输送天然气时,只需在上述阻力损失的基础上乘以天然气的密度数值。5.1.6确定管段计算长度的管段的实际管段长度加上当量长度算长度,组成管段的计算长度:实际管段长度:当量长度当量长度的计算公式如下【1】:式中::当量长度(m);:计算管段中局部阻力系数的总和。各附件阻力系数值见表5-2:管道内径(mm);:燃气管道的摩阻系数。表5-2名称ξ名称不同直径(mm)的ξ1520253240≧50变径管0.35直角弯头2.22.22.01.81.61.1三通直流1旋塞阀4.02.02.02.02.02.0三通分流1.5截至阀11.07.06.06.06.05.05.1.7计算管段阻力损失管段的计算长度同经过密度修正的单位长度管道阻力损失的乘积称为管段的总压力损失。该值即为本管段的阻力损失与前面已经计算过的管段的阻力损失累计值。至此,管道阻力损失计算完毕。5.2确定允许压力降根据设计资料及计算公式:式中:从调压站到最远燃具的管道允许阻力损失(Pa):低压燃具的额定压力(Pa)计算得:根据文献查得多层建筑室内允许压力降为400Pa,即庭院燃气管道允许压力降为1650-400=1250Pa。5.3校核第一次预选的管径计算出的压力降过高为1172Pa,小于庭院燃气管道允许压力降1250Pa。通过校核,即得出的管径符合要求。5.4举例计算下面以0-1管段为例,对其进行流量计算以及水力计算。如下画出庭院管道水力计算图,标出所需参数(2)先将水力计算表中的参数进行说明:N、K——使用双眼灶的用户数和用户同时使用系数Qh、Qn、——使用双眼灶的用户的计算流量(Nm3/h)及额定流量(Nm3/h);d——管道内径(mm);dn——公称直径(mm);L1——管段长度m;v——实际流速(m/s);——运动粘度(㎡/s);Re——雷诺数;——燃气管道的摩阻系数;——计算管段中局部阻力系数的总和。l2——单位的当量长度m;L2——当量长度m;L——计算长度m;——燃气的温度;——单位管长的摩擦阻力损失;——燃气管道摩擦阻力损失(Pa);——累计燃气管道摩擦阻力损失(Pa);(3以附表1中0-1管段为例,按照Excel表格中各项的计算顺序说明表格中含有的程序、公式。a.计算用户的计算流量=91.98b.确定实际流速确定在预选管径时假定的经济流速定为6m/s,根据计算流量以及预选管径所对应内径来确定实际流速。73.65mm查5-1表选用外径dn75的管道,以下公式中的d用对应于外径70mm的内径61.4mm计算。根据下列式子计算管段0-1的实际流速:≈5.78m/sc.计算单位管长摩擦阻力损失根据管段的Qh、V实以及运动粘度,求出雷诺数、判别流态;并选择对应的计算公式计算得出单位摩擦阻力损失并进行密度修正。管段0-1,雷诺数为:=(0.75/1000)×5.78/0.00000862≈50322.32的计算需要选用公式,该过程由下列语句来实现:如果(Re<2100,,IF(Re>3500,,))如果Re值如果小于2100,就用这一公式;如果不小于2100,并且大于3500,则套用公式,如果Re大于2100小于3500时,套用公式。因为雷诺数为50322.32,大于3500,采用与紊流相对应的公式:=≈0.02和的计算过程一样,需要根据雷诺数来判断流态从而选定公式。所用语句为:(Re<2100,,(Re>3500,))因为雷诺数为50322.32,大于3500,采用与紊流相对应的公式:≈5.09Pa/m密度修正后单位管长摩擦阻力损失为:Pa/m燃气管道的管段计算长度确定 =32.5m式中:——计算管段中局部阻力系数的总和,在管段0-1中的局部阻力见下表(管段0-1局部阻力明细表)名称 数量 局部阻力系数截止阀15d.计算长度确定管段0-1的计算长度:L=L1+L2=49.87me.压力损失计算管段0-1的总压力损失及0-13的累计压力损失:=×L=187.30Pa:管段从节点0到节13为止的管段累计阻力损失为1372Pa,f.校核经过校核通过,最后确定0-1管段管径为dn75累计管段总压力损失为1319,见表0-13。通过校核,则确定管径。至此,管段0-1的水力计算完成。其余管段均按照以上步骤完成。下表为管道0-13的局部阻力损失表.表5.4.2(局部阻力损失表)管段附件名称局部阻力系数×数量累计局部阻力系数0-1截止阀5.0×151-2三通直流变径管1.0.×10.35×11.352-3三通直流1.0×113-4三通直流1.0×114-5三通分流1×115-6三通直流变径管1.0×10.35×11.356-7三通直流变径管截至阀1.0×10.35×16.0×17.357-8三通直流1.0×118-9三通直流变径管1.0×10.35×11.359-10三通直流截止阀1.0×16.0×1710-11三通直流变径管1.0×10.35×11.3511-13直角弯头截止阀三通直流2.0×16.0×11.0×195.5庭院各管段水力计算结果(详见下表)管道0-13庭院低压管网最不利环路水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和当量长度(m)计算长度(m)管段阻力损失(pa)0-13506300.14691.9873.63755.7850322.320.025.093.7632.5517.3749.87187.301-2294529.20.1579.3874.93754.9943428.850.023.922.899.113.3612.463640.15767.2668.98754.2336797.340.022.932.1641.913.2345.1397.423-4182327.60.16152.7461.08634.7034352.450.024.393.248.41.353.6012.0038.814-51502700.16444.2855.97633.9540096.930.023.222.3736.912.7639.6694.195-6901620.17127.7044.27503.9222733.670.034.253.1322.81.352.5825.3879.516-74886.40.17615.2132.80502.1512479.150.031.481.0923.9711.6135.5138.667-840720.18513.3230.70402.9413663.840.033.392.5013.41.351.8315.2338.078-93257.60.19511.2328.19402.4811521.940.032.511.852111.3022.3041.299-102443.20.229.5025.93323.2812186.670.035.434.0069.87.357.7277.52310.2810-111628.80.236.6221.65253.7510871.980.039.346.89211.351.0722.07152.0311-13814.40.323.8416.48252.176302.600.043.572.6415.996.2922.1958.481172管道0-1-2-3-4-5-6-7-8-9-10-11-12-13的压力降为=1172Pa,而规范要求的最大压力降为1250Pa,能够满足压力的要求。管道4-23和1-34庭院低压管网环路水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和当量长度(m)计算长度(m)管段阻力损失(pa)4-193257.60.19511.23225.73323.8814402.430.037.295.3725.266.5531.75170.6719-202443.20.229.50423.67323.2812186.670.035.434.001511.0516.0564.2420-211628.80.236.62419.76253.7510871.980.039.346.8998.77.355.85104.55720.0521-23814.40.324.60816.48252.617563.120.034.933.6317.196.5723.6785.991-2756100.80.17417.539232.15403.8817991.950.035.514.0640.268.6648.86198.4827-284886.40.17615.206429.94403.3615598.930.034.283.1620.811.4022.207018513.3228.02324.6017079.800.039.857.2613.91.351.5315.43112.1229-303257.60.19511.23225.73323.8814402.430.037.295.374477.6551.65277.5830-312443.20.229.50423.67255.3815598.930.0317.6813.0413.71.351.1714.87193.8631-321628.80.236.62419.76253.7510871.980.039.346.8920.910.8021.70149.4232-34814.40.324.60816.48252.617563.120.034.933.6317.496.5723.9787.08管道2-56庭院低压管网环路水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和当量长度(m)计算长度(m)管段阻力损失(pa)2-4156100.80.17417.5432.15403.8817991.950.035.514.0620.368.6628.96117.6441-434988.20.17515.4430.16325.3319791.790.0312.799.4312.11.351.5913.69129.0543-454275.60.18213.7628.54324.7517642.970.0310.437.6915.611.1516.75128.8245-4735630.19112.0326.63324.1615429.520.038.236.0712.311.1113.4181.4047-492850.40.19910.0324.31323.4612860.630.035.974.4034.477.4441.84184.1749-512137.80.228.3222.14254.7113649.070.0313.9610.2912.51.351.1313.63140.3451-531425.20.256.3019.27253.5710340.200.038.556.3015.210.7915.99100.7853-56712.60.324.0315.42252.286617.730.043.892.8720.696.3626.9677.43管道3-72庭院低压管网环路水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和当量长度(m)计算长度(m)管段阻力损失(pa)3-5756100.80.17417.5432.15403.8817991.950.035.514.0619.268.6627.86113.1757-594988.20.17515.4430.16325.3319791.790.0312.799.4311.21.351.5912.79120.5759-614275.60.18213.7628.48324.7517642.970.0310.437.6920.511.1521.65166.5261-6335630.19112.0326.63324.1615429.520.038.236.0712.111.1113.2180.1963-652850.40.19910.0324.31323.4612860.630.035.974.4029.877.4437.24163.9265-672137.80.228.3222.14254.7113649.070.0313.9610.2911.81.351.1312.93133.1367-691425.20.256.3019.27253.5710340.200.038.556.3017.110.7917.89112.7569-72712.60.324.0315.42252.286617.730.043.892.8719.596.3625.8674.28管道5-88和6-101庭院低压管网环路水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和当量长度(m)计算长度(m)管段阻力损失(pa)5-73601080.17619.0133.47404.2019498.670.036.354.6815.968.8224.72115.7673-755395.40.17716.8931.55403.7317321.690.035.153.8013.61.351.9315.5359.0075-774682.80.17914.8229.56403.2815210.520.034.093.0219.311.3920.6962.4477-793970.20.18512.9927.67324.4916660.170.039.426.9512.111.1313.2391.9079-813257.60.19511.2325.73323.8814408.800.037.295.3731.67.358.0339.63212.9981-832443.20.229.5023.67323.2812192.060.035.434.0012.411.0513.4553.8483-851628.80.236.6219.76253.7510876.790.039.346.8916.41.351.0717.47120.3585-88814.40.324.6116.48252.617566.470.034.933.6322.596.5729.07105.61821.896-904275.60.18213.7628.48324.7517650.780.0310.437.6933.77.88.9342.63327.9890-9235630.19112.0326.63324.1615436.350.038.236.0711.711.1112.8177.7692-942850.40.19910.0324.31323.4712866.320.035.974.4011.811.0612.8656.6294-962137.80.228.3222.14254.7113655.110.0313.9610.2910.710.8411.54118.7996-981425.20.256.3019.27253.5710344.780.038.556.3012.510.7913.2983.7698-101712.60.324.0315.42252.286620.660.043.892.8719.2096.3625.5673.42738.315)从调压站选取最不利环路为最远点阻力损失;即从节点0到节点13之间管段的阻力损失,最终累加结果为1372Pa.。该值在庭院管道的允许压损失范围内。6.室内燃气管网水力计算6.1燃气室内布置依据建筑燃气供应系统的组成,一般由用户引入管、水平干管、立管、用户支管、燃气计量表、用具连接管和燃气用具等组成。引管。用户引入管与城镇或庭院低压分配管道连接。在分支管处设阀门。在非采暖地区或用径小于75mm的管道输送干燃气时,可由地上直接引入室内。水平干管。引入管上可连一根燃气立管,也可连若干立管,后者应设水平干管。水平干管可沿楼梯间或辅助房间的墙壁敷设,坡向引入管,坡向不小于0.003.燃气立管。立管一般敷设在厨房或靠近厨房的阳台、走廊内。当由地下引入室内时,立管在第一层内设阀门。阀门一般设在室内,对重要用户应在室外另设阀门。立管在下端应装丝堵,其管径一般小于25mm。立管通过各层楼板处应设套管。套管高出地面至少50mm,套管与燃气管道之间的间隙应用沥青和油麻填塞。用户支管。由立管引出的用户支管,在厨房内其高度不小于1.7m。敷设坡度不小于0.002,并由燃气计量表分别坡向立管和燃具。支管穿过墙壁时也应安装在套管内。6.2水力计算金港小区共有13栋住宅楼,1、2、5、6、10#为七层;4户/层,各28户;3、13、14为八层;3户/层,各24户;4、9#为8层,4户/层,各32层;7、8#为8层,2户/层,各16户;12#每层6户,共7层,共有42户。每户灶具配置:(1)每户用户同时安装双眼灶和热水器(2)燃具的用气量:每户燃气灶0.8m3/h,热水器1m3/h(3)管道附件局部阻力损失表名称ξ名称不同直径(mm)的ξ1520253240≧50变径管0.35直角弯头2.22.22.01.81.61.1三通直流1旋塞阀4.02.02.02.02.02.0三通分流1.5截至阀11.07.06.06.06.05.0现以十二号住宅楼为例进行水力计算:首先对住宅楼进行管线布置,画出十二栋系统图:管段按顺序编号,凡管径变化或流量变化处均需编号,并标上各计算管段的实际长度QUOTE。求出各管段的额定流量,在通过同时工作系数法计算各管段的计算流量。Q=KtΣKQnN(3)管段按顺序编号,凡管径变化或流量变化处均进行编号,并标上各计算管段的实际长度QUOTE。根据计算流量设定各管段的管径(用户支管的最小管径为DN15)。查表得各管段的局部阻力系数,查图得=1时的值,并求出当量长度QUOTEQUOTEL2=在计算各管段的计算长度L=L1+L2QUOTE。计算燃气压降值,且因为设计中燃气密度为0.75kg/m3,需进行修正,即得到的修正后的管段的单位长度的压降值ΔP/L,乘以管段计算长度L,管段的阻力损失ΔP。计算各管的的附加压头QUOTE即QUOTEΔH=求各管段的实际压力损失,即。求室内燃气管道的总压力降,天然气一般不超过400Pa(不包括燃气表的压力降)。将室内燃气管道的总压力降与允许的压力降进行比较,如不合适,则可调整个别管段的管径。室内燃气管网的水力计算都以以上步骤进行计算,现举例以十二栋进行计算。1:编号完成后,求出各管段的额定流量,根据同时工作系数法计算其他各管段的Qh。以0-1为例,计算公式为Q=KtΣKQnN=1.0×7×1.8×0.29=3.652:由系统图求得各管段的长度并根据计算流量预选管径,以L1=6.1;预选管径DN25的PE管。3:算出管段的局部阻力系数,并求出当量长度QUOTEQUOTEL2=从而可得到各管段的计算长度L=L1+L2QUOTE。管段0-1中燃气的流速W:W==4×3.65/3600×3.14×0.025^2=2.07m/s则Re=dW/v=0.025×2.07/0.00000862=5997当>3500时为紊流,则=0.04l2=d/=0.015/0.04=0.69m各管件局部阻力系数可由表6-1查得管段0-1产生局部阻力得管件主要由DN25直角弯头一个=2.0,三通分流一个=1.5,管段0-1局部阻力系数为:Σξ=2.0+1.5=3.5管段0-1的局部阻力的当量长度为L2=l2Σξ0-1=0.69×3.7=2.42m管段0-1的实际长度为L1=6.1m,则管段0-1的计算长度为L=L1+L2=6.1+2.42=8.524:燃气管道单位长度压力降可通过下式计算:以管段0-1为例,管内燃气计算温度以15℃计,根据下式求得其单位长度压降为:;=3.28Pa管道0-1的压力损失为:△P0-1=△P0-1/L×L=3.28×8.52=27.9Pa5:计算各管的的附加压头,该管段沿燃气流动的方向的终始端标高差为△H=(0mQUOTE)即QUOTEΔP附==9.81×(1.293-0.75)×(-0.1.5)=-8.436:求各管段的实际压力损失,为:△P实=△P0-1-△P附=27.9-(-8.43)=36.33Pa7:按照求管段0-1的流程对其他立支管进行水力计算,最后求出十二栋引管1的室内燃气管段的计算总压力降为343Pa(见下表);根据规范在多层建筑室内计算压力降一般不超过400Pa(不包括燃气表的压力降),符合标准。12#引入管1室内管网水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和l2当量长度(m)计算长度(m)管段阻力损失(pa)△H附加压头损失(Pa)管段实际压损损失管段局部阻力系数说明0-1712.60.293.6514.68252.075997.320.043.282.426.13.50.6902.428.5227.90-1.5-8.4336.33三通分流ξ1.5,直角弯头ξ2.01-2610.80.313.3514.05251.895495.080.042.812.072.91.50.6761.013.9110.99-2.9-16.3027.29三通分流ξ1.52-3590.353.1513.65202.796462.630.047.315.392.91.850.5611.043.9428.80-2.9-16.3045.10三通分流ξ1.5,变径管ξ0.353-447.20.382.7412.70202.425613.250.045.714.212.91.50.5430.813.7121.19-2.9-16.3037.49三通分流ξ1.54-535.40.442.3811.83202.104874.670.044.453.282.91.50.5240.793.6916.41-2.9-16.3032.71三通分流ξ1.55-623.60.562.0210.90153.175514.770.0413.159.702.91.850.4040.753.6547.97-2.9-16.3064.27三通分流ξ1.5,变径管ξ0.356-711.811.8010.30152.834923.910.0410.777.942.91.50.3930.593.4937.59-2.9-16.3053.89三通分流ξ1.57-811.811.8010.30152.834923.910.0410.777.942.15.50.3932.164.2645.9100.0045.91三通分流ξ1.5,旋塞阀ξ4十二栋的1-6单元室内官网压力损失都与十二栋引入管1相同;及使用以上的表表示。以下是各楼栋单元根据室内官网压力损失计算的压力降,各支管立管的最大压降都小于室内多层建筑的最大的允许压降值400Pa.6.3室内各管道水力计算表4、9#室内管网水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和l2当量长度(m)计算长度(m)管段阻力损失(pa)△H附加压头损失(Pa)管段实际压损损失管段局部阻力系数说明0-1814.40.273.8915.14252.206381.380.043.652.696.13.50.7012.458.5531.25-1.5-8.4339.68三通分流ξ1.5,直角弯头ξ2.01-2712.60.293.6514.68252.075997.320.043.282.422.91.50.6901.043.9412.89-2.9-16.3029.19三通分流ξ1.5,2-3610.80.313.3514.05251.895495.080.042.812.072.91.50.6761.013.9110.99-2.9-16.3027.29三通分流ξ1.53-4590.353.1513.63202.796462.630.047.315.392.91.850.5611.043.9428.80-2.9-16.3045.10三通分流ξ1.5,变径管ξ0.354-547.20.382.7412.70202.425613.250.045.714.212.91.50.5430.813.7121.19-2.9-16.3037.49三通分流ξ1.5,5-635.40.442.3811.83202.104874.670.044.453.282.91.50.5240.793.6916.41-2.9-16.3032.71三通分流ξ1.5,6-723.60.562.0210.90153.175514.770.0413.159.702.91.850.4040.753.6547.97-2.9-16.3064.27三通分流ξ1.5,变径管ξ0.357-811.811.8010.30152.834923.910.0410.777.942.91.50.3930.593.4937.59-2.9-16.3053.89三通分流ξ1.58-911.811.8010.30152.834923.910.0410.777.941.205.500.392.163.3636.220.000.0036.22三通分流ξ1.5,旋塞阀ξ4四栋和九栋的各单元室内官网压力损失都与举例计算的引入管1相同;为压力降为366,小于400Pa;符合标准。1、2、5、6、10#室内管网水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和l2当量长度(m)计算长度(m)管段阻力损失(pa)△H附加压头损失(Pa)管段实际压损损失管段局部阻力系数说明0-1712.60.293.6514.68252.075997.320.043.282.427.23.50.6902.429.6231.50-1.5-8.4339.93三通分流ξ1.5,直角弯头ξ2.01-2610.80.313.3514.05251.895495.080.042.812.072.91.50.6761.013.9110.99-2.9-16.3027.29三通分流ξ1.5,2-3590.353.1513.63202.796462.630.047.315.392.91.850.5611.043.9428.80-2.9-16.3045.10三通分流ξ1.5,变径管ξ0.353-447.20.382.7412.70202.425613.250.045.714.212.91.50.5430.813.7121.19-2.9-16.3037.49三通分流ξ1.5,4-535.40.442.3811.83202.104874.670.044.453.282.91.50.5240.793.6916.41-2.9-16.3032.71三通分流ξ1.5,5-623.60.562.0210.90153.175514.770.0413.159.702.91.850.4040.753.6547.97-2.9-16.3064.27三通分流ξ1.5,变径管ξ0.356-711.811.8010.30152.834923.910.0410.777.942.91.50.3930.593.4937.59-2.9-16.3053.89三通分流ξ1.5,7-811.811.8010.30152.834923.910.0410.777.941.75.50.3932.163.8641.6000.0041.60三通分流ξ1.5,旋塞阀ξ4一、二、五、六、十栋和的各单元室内官网压力损失都与所计算的引入管1相同;为压力降为342,小于400Pa;符合标准。3、13、14#室内管网水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和l2当量长度(m)计算长度(m)管段阻力损失(pa)△H附加压头损失(Pa)管段实际压损损失管段局部阻力系数说明0-1814.40.273.8915.14252.206381.380.043.652.696.13.50.7012.458.5531.25-1.5-8.4339.68三通分流ξ1.5,直角弯头ξ2.01-2712.60.293.6514.68252.075997.320.043.282.422.91.50.6901.043.9412.89-2.9-16.3029.19三通分流ξ1.5,2-3610.80.313.3514.05251.895495.080.042.812.072.91.50.6761.013.9110.99-2.9-16.3027.29三通分流ξ1.53-4590.353.1513.63202.796462.630.047.315.392.91.850.5611.043.9428.80-2.9-16.3045.10三通分流ξ1.5,变径管ξ0.354-547.20.382.7412.70202.425613.250.045.714.212.91.50.5430.813.7121.19-2.9-16.3037.49三通分流ξ1.5,5-635.40.442.3811.83202.104874.670.044.453.282.91.50.5240.793.6916.41-2.9-16.3032.71三通分流ξ1.5,6-723.60.562.0210.90153.175514.770.0413.159.702.91.850.4040.753.6547.97-2.9-16.3064.27三通分流ξ1.5,变径管ξ0.357-811.811.8010.30152.834923.910.0410.777.942.91.50.3930.593.4937.59-2.9-16.3053.89三通分流ξ1.58-911.811.8010.30152.834923.910.0410.777.941.505.500.392.163.6639.450.000.0039.45三通分流ξ1.5,旋塞阀ξ4三、十三、十四栋和的各单元室内官网压力损失都与所计算的引入管1相同;为压力降为369,小于400Pa;符合标准。7、8#室内管网水力计算管段户数(户)额定流量同时工作系数计算流量实际管径(mm)管径d(mm)实际流速(m/s)雷诺数Re摩擦阻力系数λ摩擦阻力损失(Pa/m)密度修正(Pa/m)管段实际长度(m)局部阻力系数之和l2当量长度(m)计算长度(m)管段阻力损失(pa)△H附加压头损失(Pa)管段实际压损损失管段局部阻力系数说明0-1814.40.273.8915.14252.206381.380.043.652.695.53.50.7012.457.9529.06-1.5-8.4337.49三通分流ξ1.5,直角弯头ξ2.01-2712.60.293.6514.68252.075997.320.043.282.422.91.50.6901.043.9412.89-2.9-16.3029.19三通分流ξ1.5,2-3610.80.313.3514.05251.895495.080.042.812.072.91.50.6761.013.9110.99-2.9-16.3027.29三通分流ξ1.53-4590.353.1513.63202.796462.630.047.315.392.91.850.5611.043.9428.80-2.9-16.3045.10三通分流ξ1.5,变径管ξ0.354-547.20.382.7412.70202.425613.250.045.714.212.91.50.5430.813.7121.19-2.9-16.3037.49三通分流ξ1.5,5-635.40.442.3811.83202.104874.670.044.453.282.91.50.5240.793.6916.41-2.9-16.3032.71三通分流ξ1.5,6-723.60.562.0210.90153.175514.770.0413.159.702.91.850.4040.753.6547.97-2.9-16.3064.27三通分流ξ1.5,变径管ξ0.357-811.811.8010.30152.834923.910.0410.777.942.91.50.3930.593.4937.59-2.9-16.3053.89三通分流ξ1.58-911.811.8010.30152.834923.910.0410.777.941.605.500.392.163.7640.530.000.0040.53三通分流ξ1.5,旋塞阀ξ4七、八栋的各单元室内官网压力损失都与所计算的引入管1相同;为压力降为367,小于400Pa;符合标准。设计总结时光总会留给当时的你太多的美好和难忘;若不登高山,则不知天之高也,若不临深溪,且不知地之厚也;在做毕业设计的过程中,自己有了很多深刻的认识。在做毕业设计的时间里,自己了解到了自己的许多的不足;也从此次的毕业设计中学到了太多有用的知识。这次自己的毕业设计内容是设计浙江金港小区的燃气管网设计;通过燃气性质的计算、管网布置、管网室外、室内的燃气计算等完成此次的毕业设计。面对这些所需要设计的内容,当然也遇到了不少的问题。当出现问题的时候,自己首先会查文献,查阅相关的资料进行知识的了解;且避免在设计过程中出现问题,从小的方面来看,这是对知识的不严谨;从长远方面来看,当设计到真正去实地设计的时候,不认真,以及不找到准确忧科学依据的知识;会造成很大的危险。而且我是设计燃气的,落实到实地的时候;一点误差就会在极大的危险,后果是无法估量和承担的;而且作为一个设计者,对不起自己学
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 电子商务网站安全防护检测方法
- 2026年AI手机安全与伦理规范亟需完善重点问题解析
- 2026年玉湖冷链“数智护年味”经验:5万吨冻品自动化立体库运营复盘
- 2026年改善型住房宽厅设计得房率提升至93%技术解析
- 2025年前台服务规范模拟训练卷
- 2026年未来能源产业:绿色氢能核聚变能技术突破与产业化路径解析
- 2026年智能家电数据管理与人机交互关键能力要求
- 2026年省级财政支持城市片区更新项目申报书模板
- 2026年电离层杂波对低空雷达影响分析
- 2026年节能门窗在住宅与商业建筑领域应用需求潜力对比
- (高清版)DB62∕T 4668-2022 农村单罐直通式和积肥式户用卫生旱厕建设技术规范
- 企业文化课件讲解内容
- DB13(J)-T 8349-2020 城市精细化管理标准(2024年版)
- 高效团队建设的技巧与案例
- 《旅行社经营与管理》课件 第三章 旅行社产品营销
- 高中三年教学规划:一体化教学策略研究
- ORACLE-EBS财务模块操作手册
- DBJ50-T-157-2022房屋建筑和市政基础设施工程施工现场从业人员配备标准
- 运动对学生情绪调节的作用机制研究
- 地磅及地磅房施工方案
- 家长学校的组织架构及职责
评论
0/150
提交评论