Foreword

AccordingtotherequirementsofDocumentGONGXINTINGTONG〔2012〕No.160issuedbytheGeneralOfficeoftheMinistryofIndustryandInformationTechnology"NoticeonArrangingtheDevelopmentPlanofCommunicationEngineeringConstructionStandardsin2012",thisrevisedcodehasbeendevelopedbyamendingtheProvisionalAcceptanceSpecificationsfor2GHzWCDMADigitalCellularMobileCommunicationSystem(YD/T5173-2009)issuedbytheMinistryofIndustryandInformationTechnology.

Thiscodeiscomprisedofgeneralprovisions,termsandsymbols,pre-acceptanceinspection,preliminaryacceptance,commissioning,finalacceptanceandappendixes.

Articles3.4.2and3.6.3printedinboldtypearecompulsoryprovisionsandmustbeenforcedstrictly.

TheCommunicationDevelopmentDepartmentofMIITisresponsibleforexplainingandsupervisingimplementationofthiscode.Ifanysupplementsorrevisionsarefoundtobenecessarilysupplementedorrevisedduringtheimplementationprocess,pleasecontacttheCommunicationDevelopmentDepartmentandpostthesupplementsorrevisionstotheDepartment(Address:No.13Xichang'anAvenue,Beijing,Postcode:100804).

FormerChiefDevelopmentOrganization:

ChiefDevelopmentOrganization:

ChinaInternationalTelecommunicationConstructionCorporation

ChiefDrafters:

MengRuiwenZhangXingwuRenRongWangJianguo

ParticipatingOrganizations:

LiaoningPlanningandDesigningInstituteofPostandTelecommunicationCo.Ltd.ChinaInformationTechnologyDesigningConsultingCo.,Ltd.andHuaxinConsultingCo.,Ltd.

ChiefParticipants:

LiSuzhiLiZhichaoChangHeLiMengWangBin

Translators:

LianRongrongLiQuanfaZhaoHangLiWeimin

TranslationProofreader:

WangFengwuMengYongyeWangChaoJiangShaodong

NotesonRevision

TheAcceptanceSpecificationsforWCDMADigitalCellularMobileCommunicationSystemEngineeringYD5173-2015hasbeendevelopedbyrevisingtheProvisionalAcceptanceSpecificationsfor2GHzWCDMADigitalCellularMobileCommunicationSystemYD/T5173-2009accordingtotherequirementsoftheMinistryofIndustryandInformationTechnologyofthePeople'sRepublicofChina.

Duringtherevisionofthiscode,thedraftingteamhasconductedcomprehensiveinvestigationandresearchbyconsultingconstructorsonsitesandequipmentsuppliers,byorganizingseminarsanddiscussionsparticipatedbyrelevanttechniciansandbyfullysolicitingopinionsandadvicesfromtherelevantexperts.Thelatestspecificationhasbeenrevisedandconsummatedonthebasisofnewtechniquesadopted,newstandardsimplementedandnewrequirementsoftheoperatorsonengineeringimplementations.

ThiscodespecifiesWCDMAnetworkconstructionstandardsonequipmentroomconditions,relevantoutdoorfacilities,indoorequipment,acceptancecodes,etc.TheProvisionalAcceptanceSpecificationsfor2GHzWCDMADigitaLCellularMobileCommunicationSystemicmainlyrevisedasfollows.

1.Thecodeisrenamedas"AcceptanceSpecificationsforWCDMADigitalCellularMobileCommunicationSystemEngineeringYD5173-2015".

2.Compulsoryprovisionsarestreamlinedbydeletingandaddingsomecompulsoryprovisions.Thearticlenumbersofthecompulsoryprovisionsarelistedintheforeword,andtheprovisionsareexplainedindetailsintheExplanationofProvisions.

3.Thestructuresandcontentsof<Pre-acceptanceinspection>areadjusted.

4.Somerevisionsandsupplementsaremadeonthetestingitemsinaccordancewithnewtechnologydevelopments.

5.Someunnecessarycontentsaredeleted.

Contents

1GeneralProvisions (1)

2TermsandSymbols (2)

3Pre-AcceptanceInspection (4)

3.1EquipmentRoomInspection (4)

3.2TowerandMastInspection (4)

3.3CableConduitandCableTrayInspection (4)

3.4EquipmentInstallationInspection (5)

3.5AntennaandFeederInspection (6)

3.6CabeLayingInspecion (6)

3.7PowerSupplySystemandMonitoringSystemInspection (7)

4PreliminaryAcceptance (8)

4.1PreliminaryAcceptanceTestingRequirements (8)

4.2PreliminaryAcceptanceItems (8)

5Commissioning (13)

5.1CommissioningRequirements (13)

5.2MonitoredItemsDuringCommisioning (13)

6FinalAcceptance (14)

6.1As-BuiltTechnicalDocuments (14)

6.2AcceptanceRequiemenusandConients (14)

AppendixAExplanationofWordinginThisCode (16)

AppendixBTablesofWorkCompletionAcceptance (17)

·1·

1GeneralProvisions

1.0.1ThiscodeisapplicableforacceptanceofWCDMAdigitalcellularmobilenetworks.Itisthetechnicalbasisforconstructionqualityexamination,follow-upcheckandhandoveracceptance.

1.0.2TheProjectOwnershallstrengthenthesupervisionofconstructiontechniques/andskills,organizefollow-upchecksandsignrelevantcertificates,bydelegatingProjectSupervisor(orOn-siteRepresentativeoftheOwner)accordingtotherequirementsofthiscodeandengineeringdesigns.

1.0.3TheconstructiontechnologyandqualityoftheConstructorshallmeettherequirementsofthiscode.

1.0.4TelecommunicationequipmentusedshallbequalifiedwithnetworkentrylicensesissuedbytheMIIT;non-licensedonesmustnotbeused.

1.0.5Anti-seismicperformancesofequipmentsuchasswitches,transmissions,basestations,powersupplies,accessfacilities,serversandgateways,usedinpublictelecommunicationnetworksinareaswithstipulatedseismicresistanceatandabove7degrees,shallbetestedandqualified;otherwise,thenon-qualifiedequipmentmustnotbeused.

1.0.6Thecontentsofas-builtacceptanceitemsshallbeinaccordancewiththerequirementsofengineeringdesignsandthiscode.

1.0.7Therelevantnationalpoliciesandregulationsonenergyconservationandemissionreductionshallbecarriedoutthroughthewholeprocessofprojectconstruction.

1.0.8Therelevantnationalstandards(codes),lawsandregulationsshallbesuperiortothiscodeincaseofanydiscrepancy.

1.0.9Underspecificconditions,ifitsdifficulttoimplementspecificprovisionofthiscode,theveryreasonsshallbeaddressedsufficientlyandduesolutionsandmeasurestobetakenshallbesubmittedtothecompetentdepartmentforexaminationandapproval.

·2·

2TermsandSymbols

Abbreviation

A-GPS

AMR

AUC

BG

BLER

CELL_IDCG

C/I

CN

CQT

CS

DT

EIR

FTP

GGSN

GPRS

GSM

HLR

HSPA

IMSI

MGW

MSC

OMC

PDP

P-CPICH

PLMN

PS

PSTN

P-TMSI

QoS

RAB

RNC

RRC

RSCP

SGSN

SMS

Term

Assisted-GPS

AdaptiveMultiRate

AuthenticationCenterBorderGateway

BlockErrorRate

Cell_identity

ChargingGatewayCarrier/InterferenceCoreNetwork

CallQualityTestCircuitSwitchedDriveTest

EquipmentIdentityRegister

FileTransferProtocol

GatewayGPRSSupportNodeGeneralPacketRadioService

GlobalSystemforMobileCommunicationsHomeLocationRegister

HighSpeedPacketAccess

InternationalMobileSubscriberIdentityMediaGateway

MobileServiceSwitchingCenter

OperationsandMaintenanceCenterPacketDataProtocol

PrimaryCommonPilotChannelPublicLandMobileNetwork

PacketSwitched

PublicSwitchingTelephoneNetwork

PacketTemporaryMobileSubscriberIdentityQualityofService

RadioAccessBearer

RadioNetworkController

RadioResourceControl

ReceivedSignalCodePowerServingGPRSSupportNodeShortMessageService

·3·

TDMA

UE

URA

VLR

WCDMA

TimeDivisionMultipleAccessUserEquipment

UTRANRegistrationAreaVisitedLocationRegister

WidebandCodeDivisionMultipleAccess

·4·

3Pre-AcceptanceInspection

3.1EquipmentRoomInspection

3.1.1Theconstructionofequipmentroomsshallmeettherequirementsofengineeringdesigns,andshallbecompleted,qualifiedandaccepted.Thewallsandfloorsoftheequipmentroomshallbefullydry.Thedoorsandwindowsshallbewell-sealed,dust-proofandanti-theft.

3.1.2Thelocationandsizeofreservedholesintheequipmentroom,andthemodel,quantityandlocationofembeddedpiecesshallmeettherequirementsofengineeringdesigns.

3.1.3Ifanunderfloorconduitisconstructedintheequipmentroom,itsrouteandmodelshallmeettherequirementsofengineeringdesigns,andtheconduitcovershallbefirm,neatandsealed,andtheconduitshallbewater-proof.

3.1.4Powersupplyshallbeavailableintheequipmentroom.Thelightingsystemhasbeenoperatingnormally.220VACpoweroutletsshallbeprovided.

3.1.5Theventilatingsystem,air-conditioningsystemandfire-fightingsystemshallbeinstalledandworkwell.Theindoortemperatureandhumidityshallmeettherequirementsofengineeringdesigns.

3.1.6Themonitoringsystemintheequpmentroomshallworkwell.

3.1.7Thelightningprotectionandearthingsystemoftheequipmentroomisinstalled,completedandqualified.Earthingresistancevalueshallmeettheengineeringdesignrequirements.

3.1.8FireprotectionfacilitiesfortheequipmentroomshallmeettherequirementsofthecurrentnationalfireprotectionspecificationsandthecurrentDesignStandardforFireProtectionofPostsandCommunicationsBuilding.Hazardousarticlessuchasflammableandexplosivearticlesmustnotbestoredinorneartheequipmentroom.

3.2TowerandMastInspection

3.2.1TheinspectionofsteeltowerandmastshallbeconductedaccordingtotheprovisionsofCheckandAcceptanceofStructureforMobileCommunicationSteelTowerandMastYD/T5132andtherequirementsofengineeringdesigns.

3.2.2Wherescalableantennamounts(rooftowers,pedestalsorlattice-stylemasts),mountingpolesorothersareusedtoinstallantennas,theinstallation,loads,anti-seismicpropertiesandlightning-proofmeasuresofthoseshallmeettherequirementsofengineeringdesigns.

3.3CableConduitandCableTrayInspection

3.3.1Thelocation,heightandearthingofcableconduitsandcabletraysshallmeettherequirementsofengineeringdesigns.

3.3.2Themountingofcableconduitsandcabletraysshallbeincompliancewiththefollowingrequirements.

1Entirecableconduitsandcabletraysshallbefixedstraightwithoutfluctuationorinclination.

2Cableconduitsandcabletraysshallremainparallelwithwallsorrowsofequipmentframes.Horizontaldeviationshallnotbelargerthan2.0‰.

·5·

3Cableconduitsandcabletraysshallbehungandfixedinaccordancewiththerequirementsofengineeringdesigns.Thehungandfixedcableconduitsandtraysshallbevertical,tidy,neatandfirm.

4Thepostssupportingcableconduitsandtraysshallbeixedverticallyandfirmlyontheground,theverticaldeviationshallnotbelargerthan1.5‰.Allpoststowardsthesamedirectionshallbefixedinthesameline.Thelocationofapostmaybeproperlymovedifequipmentinstallationisobstructedbythepost.

5Theflanksupportsofcableconduitsandreinforcedprofile-fixingsatconduit(tray)endsshallbemountedfirmly,neatlyandstraight.

6Thehorizontalcableconduitandcabletrayalongthewallshallbeparallelwiththefloor,andtheverticalcableconduitandcabletrayalongthewallshallbeverticalwiththefloor.

7Protectiveframesshallbeusedwherecableconduitsandtrayspassthroughtheholesoffloorsorwalls.Aftercablesbeinglaidandbound,theholesshallbesealedwithfire-resistantcoversorfireproofsealants.Theprotectiveframesandthecoversshallbepaintedwiththesamecolorasthatofthefloorsorthewalls.

3.3.3Theconduitsshallbemountedstraight,neatlyandfirmly.Theconduitsaboveandalongtherowsofequipmentframesshallbeinstalledinline,andthehorizontaldeviationsofjointsatadjacentconduitsshallnotbelargerthan2mm.

3.3.4Theexposedlengthofexpansionboltsusedforsupportandreinforcementshallbethesame(about5mmafternutsbeingfastened).

3.3.5Iron-wearsshallbepaintedwiththelsamecolor.Paintcoats(orpaintpatches)shallbeevenanduniformwithoutbrushmarksandbubbles.

3.3.6Thecableconduitandcabletrayshallbeearthedreliably.

3.4EquipmentInstallationInspection

3.4.1Equipmentinstallationshallbeincompliancewiththefollowingrequirements.

1Installation/locationsshallmeettherequirementsinthelayoutdrawingsofengineeringdesigns.

2Equipmentframeshallbesetvertically,andtheverticaldeviationshallnotbelargerthan1‰.

3Frontpanelsoftheequipmentframesinthesamerowshallbeinaverticalplane,andthedoorsshallbeopenedandclosedfreely.Thegapsbetweenadjacentframesshallnotbelargerthan3mm.

4Protectionmeasuresofelectrostaticdischargeoftheequipmentshallmeettherequirementsofengineeringdesigns.

5Allsigns,symbolsandlabelsshallbeclear,intactandaccurate.

6Aftertheinstallationoftheequipment,allaccessoriesshallbefixedfirmly,withoutanylooseness.

3.4.2Anti-seismicmeasuresandreinforcementofequipmentframesmustmeettherequirementsoftheDesignSpecificationforAnti-SeismicInstallationofTelecommunicationEquipmentYD5059andengineeringdesigns.

3.4.3LightningprotectionandearthingsystemsforequipmentshallmeettherequirementsofTheSpecificationsofEngineeringDesignforLightningProtectionandEarthingDesignforTelecommu-nicationBureaus(Stations)GB50689.

·6·

3.5AntennaandFeederInspection

3.5.1Theinstallationlocationsandreinforcementmethodsofantennasandfeeders,thedistancebetweenantennas(includingantennasofothersystems)andthedistancetonear-fieldobstaclesshallmeettherequirementsofengineeringdesigns.

3.5.2Antennaazimuthandpitchangleshallmeettherequirementsofengineeringdesigns.Theallowableazimuthdeviationshallbe±5°,andtheallowablepitchangledeviationshallbe±1°.

3.5.3Thelightningprotectionandearthingsystemoftheantennaandfeedershallworkwell,andtheearthingresistancevalueshallmeettherequirementsofengineeringdesigns.Antennashallbewithintheprotectiveumbrellazonewith45°coneangleagainstandunderthelightningrod.

3.5.4Thegauge,model,routingdirection,cabling,bindingandearthingoffeedersandalloutdoorwires,cablesandcontrolcablesshallmeettherequirementsofengineeringdesigns.Thebendingradiusoffeedersshallnotbelessthan20timesoftheexternaldiameter(thebendingradiusofflexiblefeedersshallnotbelessthan10timesoftheexternaldiameter).Feederbendsforpreventingrainwaterinvasionshallbemadebeforefeedersareledintotheequipmentroom.Thefeederbendsshallbesmoothanduniform.Thelowestpointofthebendsshallbe100mmlowerthanthelowedgeofcableentrance.

3.5.5Antennaandfeedersystemperformanceinspection:

1Feederattenuationshallmeettherequirementsofengineeringdesigns.

2Voltagestandingwaveratio(VSWR)oftheantennaandfeedersystemshallnotbegreaterthan1.5.

3.5.6ThelightningprotectionandearthingsystemforantennasandfeedersshallmeettherequirementsofTheSpecificationspfEngineeringDesignforLightningProtectionandEarthingDesignforTelecommunicationBureaus(Stations)GB50689andengineeringdesigns.

3.5.7Theinstallationlocationsofoutdoorequipmentshallmeettherequirementsofengineeringdesigns.Thefirmandsteadyinstallationshallbemadetomeettherequirementsofanti-seismic,windproof,rain-proof,lightning-protective,anti-theftandheat-dissipatedperformance.

3.5.8Cables(includingopticalfiber)ofoutdoorequipmentshallbelaidfirmly,neatlywithwater-proofmeasuresandreliableconnections.Allcablesshallbelaidseparatelywithoutcrossingaccordingtotheirclassifications.Remainedcablesshallbeixedneatlyandtheirbendingradiusesshallmeetrequirements.

3.5.9Beautificationofantennasshallbecarriedouttomeettherequirementsofengineeringdesigns.

3.5.10Labelsofthefeedersandalloutdoorwiresandcablesshallbecorrectlychosen,clearlymarked,standardlyfixedandneatlyarranged.

3.5.11Cableentryholesintheequipmentroomshallbesealedaftercableinstallationwithfireproofmaterialswhosefireproofratingsarenotlowerthanthoseofthebuildingwalls.Waterproofsealingforfeedercableentrypanelsshallmeettherequirementsofengineeringdesignsandinstallationspecifications.

3.6CableLayingInspection

3.6.1Thelayingofthesignalwireandcontrolwireshallbeincompliancewiththefollowingrequirements.

1Thegauge,modelandquantityofcablesshallmeettherequirementsofengineeringdesigns.

·7·

2Thesignalwire,controlwireandpowerlineincableconduitsandcabletraysshallbelaidseparatelyandorderlyaccordingtoengineeringdesigns.

3Thecablesshallbelaidstraightlyandneatlywithoutanycrossingandtwisting.

4Thecablesshallbetieduniformlyandmoderatelytothetransversebeamsofcableconduitandcabletray,neithertooloosenortootight.

5Thebendsofcablesshallbeuniformandsmooth,andthebendingradiusshallnotbelessthan

20timesofthecableexternaldiameter.

6Bothendsofthecableshallbemarkedobviously.

7Fiberpigtailgroovesorcorrugatedprotectivesleevesshallbeusedwhenopticpigtailcablesaredistributedoutsidethecabinets.Theprotectivesleevesshallextendintothecabinetsandanycutsoftheprotectivesleevesshallbewrappedwithadhesivetapes.Whenopticalfiberpigtailcablesarecoiledandwiredincabinets,thebendingradiusshallnotbelessthan40mm.

3.6.2ThelayingofpowerlinesshallbeincompliancewiththefoHowingrequirements.

1Thegaugeandmodeloffeederbusbarshallmeettherequirementsofengineeringdesigns,andthepowerlinesshallbelaidneatlyandaesthetically,withoutanycrossingandtwisting.

2Thesheathsofmainpowersupplycablesshallbeintact;theinsulationresistanceofcablecoretoground(ormetalscreenlayers)shallmeetthetechnicalrequirementsforthecables.

3Thebendsofpowercablesshallbeumiformandsmooth.Thebendingradiusofarmoredpowercablesshallnotbelessthan12timesoftheexternaldiameter.Thebendingradiusofplasticcladpower

cablesorotherflexiblecablesshallnotbelessthan6timesoftheexternaldiameter.

4Thelayingofpowerlinesforequipmentshallbeincompliancewiththefollowingrequirements.

1)Powerlinesmaybebundledandstraightlylaidalongtheframesfromtoptobottomifthelead-inholesforpowercablesareatthetopoftheframes.

2)Theterminallugsatbothendsofpowerlinesshallbeweldedtogetherfirmly,neatlyandreliablysoastolensuregoodelectricalconnections.Bothendsofpowerlinesshallbeobviouslymarked.

3.6.3Powercablesusedformainpowersupplymustbeintact,entireandcomplete,withoutanyjoint.

3.7PowerSupplySystemandMonitoringSystemInspection

3.7.1Thepowersupplysystemshallmeettherequirementsofengineeringdesigns.Thepowerlinesshallbeconnectedreliablywithcorrectpolarity.Allairswitchesandfusesshallbeconnectedandclampedfirmlywithobviousandaccuratemarks.

3.7.2Thebuilt-inmonitoringsystem,allauxiliaryequipmentandalarmfacilitiesshallbeinagoodworkingstate.

·8·

4PreliminaryAcceptance

4.1PreliminaryAcceptanceTestingRequirements

4.1.1Preliminaryacceptanceshallbeconductedonlyaftertheequipmentissuccessfullyinstalledandqualifiedbycheckingandtesting.

4.1.2Afterreceivingthehandovernotificationandas-builtdocumentsfromtheconstructor,theownershallorganizeanacceptanceteamforpreliminaryacceptanceinaccordancewiththerelevantdocumentaryinstructions,whiletheconstructor,designer,supervisorandequipmentsupplieroragentshallactivelycooperatewith.

4.1.3Testingcontentsforpreliminaryacceptanceshallbepreparedaccordingtothiscode,andparameterstobetestedshallmeettherequirementsofbothdesigndocumentsandtechnicalspecifications.

4.1.4Ifanykeyparameterorperformancefallingshortoftherequirementsisfoundduringpreliminaryacceptancetesting,theresponsiblepartyshallsolvetheproblemsintime.Re-testingshallbecarriedoutaftertheproblemsbeingsolved.

4.2PreliminaryAcceptanceItems

4.2.1Preliminaryacceptanceitemsforwirelessnetworkscontain:

1Inspectionofbasestationconfigurations:

1)Softwareandhardwareareinstalledcorrectly,andindicatorsofallindividualunitsareworkingproperly,

2)Theconfigurationsoffrequency,coderesource,channelandpowershallmeettherequirementsofengineeringdesigns.

3)Systemparametersareconfiguredproperly.

4)Adjacentcellsshallbeallocatedproperly.

2ThecontentsofOMC-RfunctionsandperformancestobetestedforacceptanceshallbesetrespectivelyinaccordancewithAppendixB.0.1:OMC-RfunctionacceptancetableandAppendixB.0.2:OMC-Rperformanceacceptancetable.

3PerformanceIndicators.

1)ThecontentsofwirelessnetworkfunctionstobetestedforacceptanceshallbesetinaccordancewithAppendixB.0.3:Wirelessnetworkfunctionacceptancetable.

2)ThecontentsofwirelessnetworkperformancestobetestedforacceptanceshallbesetinaccordancewithAppendixB.0.4:Wirelessnetworkperformanceacceptancetable.

4.2.2Preliminaryacceptanceitemsforcorenetworkscontain:

1Thecontentsoftheperformanceacceptancetestforcircuit-switchingdomainshallbesetinaccordancewithAppendixB.0.5:Circuit-switchingdomainperformanceacceptancetable.

2Thecontentsoftheperformanceacceptancetestforpacket-switchingdomainshallbesetinaccordancewithAppendixB.0.6:Packet-switchingdomainperformanceacceptancetable.

3Thecontentsoftheperformanceacceptancetestfornetworkmanagementsystemshallbeset

·9·

inaccordancewithAppendixB.0.7:Networkmanagementsystemperformanceacceptancetable.

4.2.3PreliminaryacceptancetestitemsforCallQualityTest(CQT)contain:

1CallQualityTest.

Thecallqualitytest(CQT)shallbecarriedoutatassignedindoorlocations.Thetestingforcircuit-switchingservicesshallbeaccomplishedbyindoorCQTtestersbycallingtestcellphonesmutually.Thetestingforpacket-switchingservicesshallbeaccomplishedbyindoorCQTtestersbyuploadinganddownloadingdataatassignedlocations.

PleaserefertoAppendixB.0.8:CQTperformanceacceptancetableforthecontentsofCQTperformanceacceptancetest.

2Networkperformancetesting.

1)ThecontentsofCQTperformancetestingarelistedinTable4.2.3:

Table4.2.3ContentsofCQT

Item

Content

Description

Coveragerate

RSCPcoveragerate

TestingpointswithqualifiedRSCPcoverage/totaltestingpoints×100%

Ec/Iocoveragerate

Ec/locoveragequalifiedtestingpoints/totaltestingpoints×100%

Voice

Callcompletionrate

Callcompletiontimes/callattempttimes×100%

Calldroprate

Calldroptimes/callcompletiontimes×100%

Inconsecutivevoiceandbackgroundnoiseoccurrencerate

(Inconsecutivevoiceoccurrencetimes+backgroundnoiseoccurrencetimes)/callcompletiontimes×100%

Unilateralcall,echoandcrosstalkoccurrencerate

(Unilateralcalloccurrencetimes+echooccurrencetimes+crosstalkoccurrencetimes)/callcompletiontimes×100%

Videophone

Callcompletionrate

Callcompleniontimes/callatempttimes×100%

Callinterruptionrate

Callinterruptiontimes/callactivationtimes×100%

Voicedelay(s)

Theend-to-endvoicedelayinaconversation

Videoandvoiceasynchronizationrate

Asynchronizationtimes/callcompletiontimes×100%

Data

PDPactivationsuccessrate

PDPactivationsuccesstimes/callattempttimes×100%

Interruptionrate

Interruptiontimes/PDPactivationtimes×100%

Averagedownloadthroughputrate(kbps)

Totalthroughput/downloadtime

Integratedservices

Completionrate

Completiontimes/callttempttimes×100%

Droprate

Droptimes/completiontimes×100%

Inconsecutivevoiceandbackgroundnoiseoccurrencerate

(Inconsecutivevoiceoccurrencetimes+backgroundnoiseoccurrencetimes)/callcompletiontimes×100%

Unlateralcall,echo,crosstalkoccurrencerate

(Unilateralcallccurrencetimes+echooccurrencetimes+crosstalkoccurrencetimes)/callcompletiontimes×100%

PDPactivationrate

PDPactivationtimes/callattempttimes×100%

Interruptionrate

Interruptiontimes/PDPactivationtimes×100%

Averagedownloadthroughputrate(kbps)

Totalthroughput/downloadtime

2)Testingrequirements:

LocationselectionofCQTtesting:Transportationjunctionssuchasairports,trainstationsanddock,businessandentertainmentcenters,hotelsandotherhightrafficareasshallbechoseninurbanareas.Customerscomplaintsaboutnetworkqualityrecordedby

·10·

customerservicecentersshallbetakenintoconsiderationforthelocationselectionofCQTtesting,Multi-storybuildingslikethehighestbuildingandthelargestbusinesscenterinuseshallalsobethecandidates.Testingshallbecarriedoutatleastatthetopfloor,themiddlefloorandthebottomfloorinmulti-storybuildings.

Testingmethod:20timestestingateachassignedindoorlocationshallbeexecutedbytheCQTtestersactedrespectivelyascallingpartyorcalledparty,whileeachcalldurationshallnotbeshorterthan30secondswithabout10secondscallinterval.Thetestersshallrecordandlogtherawdataofrelevanttestingandcomeupwiththerequiredresultsintheformofpercentageaftercalculation.Nolessthan3timestestingofsuccessful(complete)uploadanddownloadwithnolessthan8MBdatapackageshallbemadeateachassignedlocation.PDPshallinitiativelyreleaseitselfassoonaseachdownloadcompletes,andnewPDPprocessshallnotbeactivatedinabout2

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论