瑞银-NVIDIA GTC大会结论:对科技供应链的影响-NVIDIA'S GTC conclusion:Implications for the Tech Supply Chain-20260323_第1页
瑞银-NVIDIA GTC大会结论:对科技供应链的影响-NVIDIA'S GTC conclusion:Implications for the Tech Supply Chain-20260323_第2页
瑞银-NVIDIA GTC大会结论:对科技供应链的影响-NVIDIA'S GTC conclusion:Implications for the Tech Supply Chain-20260323_第3页
瑞银-NVIDIA GTC大会结论:对科技供应链的影响-NVIDIA'S GTC conclusion:Implications for the Tech Supply Chain-20260323_第4页
瑞银-NVIDIA GTC大会结论:对科技供应链的影响-NVIDIA'S GTC conclusion:Implications for the Tech Supply Chain-20260323_第5页
已阅读5页,还剩41页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

GlobalResearch

23March2026

APACTechnology

NVIDIA’sGTCconclusion:ImplicationsfortheTechSupplyChain

GTCtechsupplychainconclusionsandadditionalpaneltakeaways

NVIDIA’s16thGTCwasheldMarch16-19inSanJosewith30,000in-personand300,0000virtualaccessattendeesacross1,000sessionsand450+exhibits.Inthisreport,weincludeadditionaltakeawaysfromtheexhibitionfloorandsummarybulletsfrompanelsacrosscoolingandpower(CoolIT,Eaton,Delta,LiteOn,Schneider),ODMs(ASRock,Compal,GigaComputing,SupermicroandWistron)andmemory(Micron,Samsung,SKHynixandSolidigm)withothersessionscoveredinTimArcuri’sDay1,Day2,Day3,andDay4reportsandourGTCkeynotesupplychainimplicationsandAPACTechTourrecap(link,link).

Strongdemandandconstrainedsupply,thoughwithsmallpush-outsfromtheMiddleEast

NVIDIA’sopeningkeynotehighlighted2025-27BlackwellandRubinorderswerenowUS$1trn(vs.US$500bnfor2025-26lastfall)andthatpositivesentimentwasechoedonthefloorassupplybottlenecks(memorymostnotablybutalsooptics,PCB/substrate,andadvancedwafers)remainmoreaconcernthandemand.ThehighercomponentcostsalsolooktobepushinguprackpricingtoUS$6-7mnforVR200(vs.ourUS$6mnexpectation),upfromUS$4-4.5mnforGB300.DemandfeedbackisstrongbothfromCSPsandNeocloudssupportingourNVL72rackassumptionrampingfrom65kin2026to83kin2027(60kRubin+23kBlackwell)butalsopickingupfromenterprise,sovereignandtier2cloudforHGXdemandasusecasesforAIbroaden.MorerecentlytheUS-Iranconflictisopeningupprocurementconcernsformaterialdelivery.ODMsnotedsomedelaystoMiddleEastprojects/deliveriesandnetworkingsupportfromIsrael.

HardwareassemblysmootherandautomatedforRubin,Heliosracktimingabitlater

HardwareODMsonthefloorincludingHonHai,Wistron/Wiwynn,Quanta,Inventec,Compal,Lenovo,Pegatron,Asus,DellandSupermicroallechoedNVIDIA’scommentsonfasterandsmootherautomatedassemblyofthecomputetrayfrom2hoursto5minutesandimprovedmodulardesign.Rackassemblyandtesttimehaspulledinfrom4-6weekslastyearto2-3daysto1week(systemlevelburn-intest)thisyear.Whileinvestorsworryoncommoditization,leadODMshaveengagedinthatstandardizationmodelthroughouttheirhistoryinPCsandserversandwouldstillearnhigherGP$(albeitlowerGM%)onRubinvs.Blackwellforautomation,overseasproductioncosts,handlingandworkingcapitalfinancing,L11andverticalcomponentintegration.MostvendorsexpecttobeinmassproductionofVR200rackswithearlyvendorsfromAugustand2ndtiersuppliersfromOctoberalthoughconfidenceonmeetingthattimelineisloweronAMDHeliosgiventhenewdoublewiderackarchitectureandcouldpushitlateinto2026or2027atsomevendors.

RubincomponentstandardizationshowingupinNVIDIA’sMGXecosystem

NVIDIAonceagainshowcaseditsexpandingMGXsupplierboardintheGTCconcourse.TheMGXisdesignedtostreamlineandacceleratehardwareassembly,improveabilitytoupgradetonewgenerationsonannualcadence,andbuildaresilientsupplychainwithmultiplesuppliersatcompetitivecostalthoughdoesraiseinvestorfearofstandardizationequalingcommoditization.WhiletheMGXspecsarestandardized,vendorsstillhavedifferentwaystoimplementtoimprovereliabilityandcost,varyon

Equities

Global

Technology

RandyAbrams

Analyst

randy.abrams@

+886-2-87227338

NicolasGaudois

Analyst

nicolas.gaudois@

+65-64955148

SunnyLin

Analyst

sunny.lin@

+886-2-87227346

TimothyArcuri

Analyst

timothy.arcuri@

+1-415-3525676

DianaChang

Analyst

diana.chang@

+886-2-87227335

JerrySu

Analyst

jerry.su@

+886-28-7227306

ZoeXu

Analyst

zoe-za.xu@

+852-29717724

ThisreporthasbeenpreparedbyUBSSecuritiesPte.Ltd.,TaipeiBranch.ANALYSTCERTIFICATIONANDREQUIREDDISCLOSURES,iNcLuDiNGiNFoRmAtioNoNtHEQuANtitAtivEREsEARcHREviEwpuBLisHEDByUBS,BEGiNoNpAGE17.UBSdoesandseekstodobusinesswithcompaniescoveredinitsresearchreports.Asaresult,investorsshouldbeawarethatthefirmmayhaveaconflictofinterestthatcouldaffecttheobjectivityofthisreport.Investorsshouldconsiderthisreportasonlyasinglefactorinmakingtheirinvestmentdecision.

APACTechnology23March2026婚§2

timetomarket,serviceability,andcustomerserviceandsupport.Componentsondisplayincludepower(powershelf,distributionboardandsidecar),cooling(coldplates,rackmanifolds,innermanifolds,in-rowCDU,liquidcooledandHPMbusbar,powerwhip,UQD/MQD-universal/multiquickdisconnect),sliderails,rackchassis,andvoltageregulatormodule.

Powersupplyhasa50%+contentgainwithRubin,withpowerracksreadying

fasterforRubinUltra

TheAC-DCpowersupplyisupgradingfrom833kWpowershelvesdelivering264kWpowercapacityforGB300tosupporttherack’s130-140kWpowerwithredundancyto4110kWshelvesfor440kWpowercapacityforVR200NVL72rackstosupportits180kWMax-Qand227kWMax-PTDP.Rubinisa50%+contentgainforPSUcontenttosupportourestimatesforDeltatomaintainlastyear’s30%+YoYsalesgrowthonthebackofpowerandcoolinggrowth.Onemid-termriskisChinacompetitionwithMegmeetqualifiedbyNVIDIAandshowingupatUScustomersasaback-upsourcebyshiftingproductiontoThailandandalsosamplingitspowerrackfromApril.Westillviewspecsadvancingtoprotecthighershareforincumbents,withsteeperupgradewithRubinUltra,wherevendorsuniversallyseethehighercomputedensitymovingthepowercomponentsintoaseparatesidecarnexttotheITrack.Thefirstgenerationpowersidecarwouldfeature6x110kWpowershelvestoservea500-600kWITrackandalsointegrate5x90kWbatteryback-upshelves,powerdistributionunittoandoptionalcapacitorback-upunitsforhighercontentperwatt.VendorsarenotingNVIDIAbeingaggressivetopull-inthepowerracktoH226althoughlikelysmallvolumetobereadyforasteeperrampalongsideRubinUltrainH227.Aseparate400VsidecarsolutionisalsobeingreadiedforASICservers.Feynmancouldextendto1GWandrequirehigherdensityshelvesinthepowersidecar.

SolidStateTransformers(SST)abattlegroundforpowercontentin2-4years

800VDCtimingtostartintroducingasolidstatetransformerisstillinthe2028-2030timeperiod(potentiallyfirstwithNVIDIA’sFeynmangeneration)subjecttosafetystandardsalthoughDeltahasinitialsampleswithChinacustomersandfeedbackonthefloorshowsthepulliscomingfromthefieldsooner.TheSSTwillbeadisruptivebattlegroundasthatnewcontentdisplacestraditionaltransformersalongwithcontentfromUPSandAC-DCconversionneartherack.NewopportunitiesalsocomeinforBESS(batteryenergystorage)orfuelcells(DeltadevelopingwithCeres)and800Vto48VDC-DCconversioninrack.Vendorspursuingthisopportunitycouldincludegreyspacesuppliers(Vertiv,Schneider,Eatonetc),transformersuppliers(Siemens,MitsubishiandHitachi)andwhitespacesuppliersneartheITrack(Delta,LiteOn,Megmeet,Flex).Deltaviewsitsearlydevelopment,powerintegrationexpertiseandSiCmoduleworkwiththesiliconvendorsgivingitanopportunity.

CoolingarchitecturesstilldominatedbydirectchipcoolingandL2Asidecarsfor

RubinwhileL2LCDUsrampwithRubinUltra

ThecoolingarchitectureisstreamliningmovingfromBlackwelltoRubin,withliquidcoolingnowcovering100%oftheactivecomponents,fromhybrid80%liquid/20%airwithBlackwellto100%withRubinasnowboththehotsilicon(GPU,CPU)andfront-endcomponents(NICs,SSD,optics,VRMs)extendtothemajorcomponentsonthetraywithoutfansandimprovedinnermanifoldseparatinginflowandoutflowofliquid.Forthesidecar,L2AwhichisledinmarketsharebyDeltaextendsthroughtheRubingenerationthroughH127withDeltanowsupporting300kWcooling,LiteOndeveloping280kWCPUandSupermicroplanninganL2Asupporting500kW.L2LCDUsarebeinginstalledfornewbuildsandshouldbecomemainstreamwiththehigherpowerRubinUltrawithL2LCDUsprovidingcapacityfor2.4kWtosupport8VR200racksor4Kyberracks.L2LshouldseemorecompetitionfromsystemvendorslikeVertivandSchneider,althoughDeltaisalreadyqualifiedbyNVIDIAandemphasizingprovenreliability,maintenance,costefficiencies,DC-DCpumpsforlessnoiseandtrackrecordfromL2A.

MemoryinshortagebutacriticalcomponentforAIworkloads

ThekeynoteNVIDIAroadmapchangesandmemorysessionsechoedtherisingimportanceofmemoryasagentic,reasoningandmultimodalinferenceincreases.

Agentsandreasoningalongwithlongercontextlengtharecallingforhigherthroughputandmoretokenstopremiumusers,drivingincreasedcapacityandthroughputbothforHBMandforKvcacheoffloadtolargerpoolsofsystemmemory(shiftingtoLPDDRforlowerpower)andhighcapacityNANDSSDs.WeviewtheGroqLPUonlysupplementingtheVeraRubinGPUratherthandisplacingit.NVIDIAnotedfor

APACTechnology23March2026婚§3

itstop10customers(~60%ofrevenue)thattheseworkloadscoulddrive25%oftraffictoa220kWLPUserverusingonboardSRAMcacheandDDRassystemmemory.NVIDIArepresentativesfromGroqattheexpostillrecommendheavyVR200mixleveragingHBM,withsuggestionfora1:2mixofGPUstoLPUs.Inthissetup,GPUshandlethecomputeintensiveprefill,whiledecodeissplitsuchthatGPUsexecutetheattentionstageandLPUsexecutetheFFN(FeedforwardNetwork)stagetoimproveinferenceefficiency(9NVL72racks=648VeraRubinGPUsto5LPUracksx256LPUs(32traysof8LPUsx5racks=1,280LPUs)).BasedonfeedbackfromGTC,webelieverackpartnersfortheLPUserverareHonHaiandWistronandat10-15%oftherevenuecouldbeUS$50bnofincrementalhardwarerevenueata~2-3%OpM).

CPUscomplementingGPUcomputetodeliveragenticandmultimodalinference

NVIDIAreleasedaseparateCPUrackserverwith32traysof8CPUstohandletheincreasingcomputedemandsfororchestratingAIandalsohandlingtraditionalcomputetasksexecutedbyagents.TheCPUvolumeisseeingapick-upfortheseusesandconsolidationofolderlessefficientserverswiththeindustrystillcomputeconstrainedacrosschannels.CPUdemandisliftingsuppliersupstreamincludingAspeedrecentlyrevisingupguidance(link)andshouldsupportODMsmoreheavilytiltedtotraditionalserversincludingWiwynn(45%ofsales),Inventec(25%ofsales),Quanta(20%ofsales)andHonHai(10-15%ofsales).

NextgenrackdesignswithRubinUltra/Feynmanadjustingtoaccommodate

powerdensityandoptical

NVIDIAmodifiedandextendeditsroadmapvs.the2025GTC.TheRubinUltraKyberarchitecturehascompressedsincelastyearfrom4cannistersandmidplanePCBsto2cannistersandmidplanePCBseachcontaining4cabinetsof18computeblades,cuttingtheGPUsinthecabinetfrom288to144.WhileNVIDIA’sroadmapstillshowedadieshotwith4diesperGPU,powerandcoolingvendorsaredrivingtowardamoremanageable2-3xpowerupgradefrom227kWwithRubinto500-600kWpowerand

288diesforRubinUltrasupportedby660kWpowerrack.Thevendorsstillhaveonofferracksscalingover1MWsocouldindicatewestillseea576dierackin2027oritpushestoFeynmanin2028.NVIDIAalsointroducedanewNVL576‘scale-up’optionwithRubinUltraconnectingtogether8NVL72OberonrackswithopticaltransceiverandaNVL1,132optionwithFeynmanusingCPOtoconnect8NVL144Kyberracks.UBSviewsopticalgrowthfromthatlayoutadvancingforthemanyracktorackcommunicationsin2028withcopperstillusedforthebetweenrackconnections(link).WealsoseeKyberintroducingamidplaneconnectormodulesuppliedbyFIT,TEConnectivity,AmphenolandLuxshareversusthecartridgecablesinplaceforBlackwellandRubin.

StockoutlookintheAsiatechsupplychain

NVIDIA’sGTCkeptuspositiveontheAIsupplychainbarringprotractedMiddleEastconflictwithrelativepreferenceforsupplychaincomponentsandsemiconductorswithtightsupplyandrisingpricesversushardwarebrandsandtolesserextendODMshavingtopassthroughhighercomponentcostwithsomemarginpressure.WekeeppositiveonadvancedfoundrythroughTSMC,advancedpackaging(ASE,KYEC,HonPrecision),GPU/ASIC(Mediatek,Alchip,Aspeed),memory(Samsung,SKHynix,Micron),datacenterpowerupgrades(Delta),PCB/substrate(Unimicron,ShennanandShengyiTech).

Withinhardware,westillseepositiveperformancealbeitlaggingsemiswithearningsgrowthandsupportiveP/EforHonHai,Quanta,WistronandWiwynn.

APACTechnology23March2026a§4

Figure1:NVIDIAroadmap

Source:NVIDIA

Figure2:NVIDIAMGXreferencedesignsstandardizingcomponentassembly

Component

InRowL2LCDUColdPlate

RackManifoldInnerManifoldUQD/MQD

SlideRail

LiquidCooledBusbarHPMBusbar

PowerWhipChassis

PowerShelf

PowerSidecar

VoltageRegulatorModule

Supplier

Beehe,Boyd,Delta

AVC,CoolerMaster,Delta,Foxconn,JenTech

AVC,Boyd,CoolerMaster,CoolIT,Delta,Foxconn,LeadWealth,LiteOn,Pinda

Auras,AVC,Boyd,CoolerMaster,CoolIT,Delta,Foxconn,Readore

Auras,Beehe,Danfoss,Envicool,Fositek,LeadWealth,Lotes,Netonx,Nidec,Parker,Readore,Staubli,TaichengAccuride,ChengFwa,Fositek,Kingslide,Repon,YuansTech

Amphenol,Bizlink,Delta,Foxconn,Interplex,LeadWealth,Pinda

Amphenol,Bizlink,Foxconn,JPC,Lotes

Bizlink,Foxconn,JPC,Longwell

AVC,Chenbro,Foxconn,Interplex,Karrie,

Delta,Flex,LeadWealth,LiteOn,Megmeet,Schneider,Vertiv

APC,Delta,Eaton,Flex,LeadWealth,LiteOn,Megmeet,LeadWealth,Vertiv

ADI,Delta,Infineon,Innoscience,Megmeet,MonolithicPower,Navitas,OnSemi,Renesas,STM,TI

Source:CompanyData,UBS.Note:Vendorsondisplayonly-listnotexhaustiveofallsuppliers

APACTechnology23March2026a§5

APACTechnologyUBSResearch

PowerandCoolingPresentations

CoolIT:LiquidCooling:HowtoAchieve100%HeatCaptureon500kW+Racks

Speaker:AndrewBuckrell,PhD,SeniorThermalMechanicalEngineer,CoolITSystems

CoolITsolutions.CoolIThassolutionsrangingfromcoldplates,coldplateloops,manifolds,CDUsandpipingbetweenCDUandmanifolds.Itisworkingon100%heatcapturedesignsforHBM,voltageregulatormodules,SSDsandNICs.Itsportfolioincludescoldplatesthatcansitonprocessorsupto4kW,serverboardswith20kWpowerandCDUsthatcanhandle2MW+ofpowerandinthenextgenerationwouldscaleto3-4MW.

Coolingtheprocessor.CoolITdiscussedtechniquestoimprovethecoldplateincludingathermalinterfacematerial(TIM)madeofliquidmetal,finbondingwith50micronverticalfinsandlidbondingaroundthecoldplate.CoolIThasasplitflowtechnologytodirectcoolanttothehotspotsonachipandaunibodyprocessforreliability.Thecompanyalsooffersdoublesidedcoldplatesthatcancoolthetopsideandbottomsideofcomponents.Theindustryisalsomovingtoward2-phasecomponentswhichintegratevaporchamberandheatpipes.ThecompanyusesvaporchamberstocoolmemoryDIMMswhicharenowapproaching40W.

Coolingtheserver.Thecompanyoffersamonolithiccoldplateassemblywithmachinedchannelsforhigherflowratesandbettercontacttothecomponents.Ithasanallaluminumdesignforweightreduction.

Singlephasecoolingstillthebestapproachforheatcaptureinthenextdecade.

Thecompanyseessinglephasecoolingasthepathforwardforthenextdecadewithstrengthsofbestheatcaptureacrossdie(300W/cm-squared),chip(4kWTDP),server(20kW+)andrack(500kW+)plusbenefitsofinteroperability,multi-vendorusageanddifferentcoolantoptions.CoolITalsoexpectstointroducea15kWcoldplateasits6thgenerationinH126with100%heatcapture.

Capabilitiesadvancing.CoolITplanstoincreasedieheatfluxfrom300Wto500W/squarecentimeterinQ326,from4kW+to15kW+forcoldplatesinQ126,forserversfrom20kW+to50kW+inQ126andCDUsfrom2MW+to10MW+inrowin2027.

Eaton:ASafe,EfficientandScalableApproachto800VDCArchitecture

Speaker:JoshuaBuzzell,VP,DataCenterChiefArchitect

Eatonvisionforthedatacenter.Eaton’svisionissystemlevelco-designintegratingpower,ITandcoolingforhighdensitydeployments.Eatonnotedtrendsforrackpowertorampupfrom10-50kWperrackupto1MWanddatacenterpowerto1GW,requiringmodular,scalableandfaulttolerantinfrastructure.

Modulararchitecturestrategyfordatacenters.Eaton'sstrategytobuilddatacentersbyblocks:1)powergeneration/gridconnection,2)grayspacepowerconditioning(generation,substations,BESS),3)isolationandstability(switchgear,mediumvoltagetransformers,UPS,cablemanagement),4)whitespacepowerconditioning/delivery/stability(800VDCsidecar,busbars,supercapacitors),5)cooling.Sidecaraninterimsolution.ThecurrentgenerationdatacenterhasaUPSwhichrequiresAC-DCandDC-ACconversionat97.5%efficiency.ThenextphaseisanAC-DCsidecartotransfer480VACto800VDCpowerat98%efficiency.Thefinalstepisthemediumvoltagesolidstatetransformerat98.5%efficiencytoconvertthemediumvoltACtolowvoltageDCandthenhaveDCdistributionthroughoutthedatacenter.EatonseesthisSSTdeliveringpowertotherackoramoduleinthewhitespace.

APACTechnology23March2026婚§6

Eaton’splanforamediumvoltageSST.Eatonisdesigningamediumvoltagesolidstatetransformertotakein9-500kV,transformthatvoltagedownto9-35kVandthenuseaSSTtoconvertthevoltageto800VDCpower.ThebenefitofanSSTisthatitcanfitinthebackofatruckandconsolidatealotofdevices(padmountedtransformer,mainswitchboard,UPS,lowvoltagedistribution).FeaturesofEaton’sSSTwillincludeintelligentpowermodule,reconfigurableandselfhealingpowerdeliverywithredundancy,abilitytowithstand2xvoltagesurgefor2minutes,magneticlink/synchronousswitchingandlowcapacitanceintheDCbuswithArcflashfreefortheoutputports.Challengeshistoricallyincludecost,reliabilityandstressesfrominternalandexternalfaultslikepowersurgesandshortcircuits.Largeloadsathighvoltagecancreaterisksoffaultcurrents,arcflashenergy,malfunctionofdeviceprotection,andfaults.

Buswaydistributionsystem.Ahighcapacitybusbarcandistributethe800VDCacrossthedatahallwithplug-inrackfeeds.Thebuswaycansupportthousandsofamps,plugandplayrackfeesandlesscablingcomplexity.ThedistributionpointcandeliverthepowereithertoaDCremotesidecarorremotepowerpaneltosplitthe800VDCfeedintodifferentcircuitsfortheracks.Rackdensityisgoingfrom150kWto250-350kWbutwilleventuallygetto1.5MW.Todeliverthat,abuswaysystemwithplug-intapboxescouldbeusedtodeliverpowertoracksalongthebuswayorremotepowerpanelscanbeusedtoservegroupsofsmallerracks.

Delta:800VDCPowerandModularDataCenterSolutions

forNextGenAIInfrastructure

Speakers:RalfPieper,R&DDirector(26yearsatDelta)andJasonAgee,DirectorofDataCenterSolutions&Architecture(25yearsindatacenterinfrastructure)

Evolutionofthepowersupplyinthedatacenter.Deltadiscussedtheevolutionofthepowerdistributioninthedatacenter,startingwithFacebook’sOpenComputeProjectwithitsOpenRackversion2(ORV2)whichpoweredarackwith12voltstodeliver25-30kWofpower.TheORV3upgradedthatto50Vtoraisethepowerlevelto200-250kWnowinmassproductionforBlackwellandthecomingRubingenerations.

ThespeakernotedtheplanswithRubinUltraandbeyondtoreachupto1MWofpowertotherackmakes50Vinsufficient,asitwouldrequire20,000ampstodeliverthatmuchpower.Anupgradeto800VDCisnowintheworkstobringthoseampstoamorerealisticlevel.Deltaviewsitselfaleaderforthistransitionas#1inpowersupplyandbrushlessfanswithUS$17.9bnsalesin2026(upfromUS$13bn)and>8%ofrevenuereinvestedinR&D.

ScaleupoftheAIserverrequiringhigherdensitypowershelvesand800VDC

Power.TheAIserverrackpoweriscurrentlydeploying33kWpowershelveswithsinglephasepowersuppliersx4shelvesfor120kWofpower.ForVR200,itwillupgradeto110kWx4shelvestodeliver440kWofpower.WithaclusterofITracksinthefutureat

576GPUs,itwillrequire800Vdatacentertodeliverover1MWofpower.

Chiptodatacenterpowerdemandallscalingup.ThepowerlevelscalesupfromtheAIchipwhichhas500W-1.5kW,AIserverboardwith4-8chipsontheboardwith2-10kW,AIserverrackwith18boardsat30-120kWandaclusterforthedatacenterreaching30-120MW.Inthefuture,theselevelswillincreaseforthechipto2kW,serversto15kW,racksfrom250kWto1MWandthedatacenterupto1GW.Arackisnowtheequivalentof100housesand1datacenterupto100,000houses.Delta’spowersuppliesnowreach98%efficiency,up2%vs.the12Vunitsadecadebacktohelpconservesomeofthispower.

800Vdatacentertransitionplan.Thecurrentdatacenterstepsdownfromalinefrequencytransformerfrom34.5kVto400-480VAC.AGB300singlephasepowershelfconvertsthe480VACto50VDCtodeliverappropriatepowertherackbusbartothengointotheservertodownconverttoa12Vandthen<1VtodeliverthepowertotheGPU.ForVeraRubin,unitswillmovetoa3phaseACunitat18kWand50Voutputtothebusbar.Forover250kWracksfromRubinUltra,Deltarecommendsthe800Vsidecarforthe3phaseACtogenerate800V.ThatisdistributedthroughacrosslinkcableratherthanbusbartotheITrack.Intherack,itwillneedanewDCtoDCconvertertoconvertthe800Vto50Vandthencandownconvertto50V/12Vand0-1VtotheDatacenter.Inthefinalstage,anSSTtransceiverdirectlyconvertsthe34.5kVACpowerdirectlyto

APACTechnology23March2026a§7

800VDCwhichthenisdistributedinsidethedatacentertoaDCtoDCconvertertolowerthevoltagefrom800Vdownto12Vand0-1V.

Delta’sproductfamilytoNVIDIA.Deltashoweditsroadmapforpowerdelivery:1)GB200/30033kWpowershelfmadeupof5.5kWx6powersuppliersat50Vwith75Jperpowersupply,2)VeraRubin100kWpowershelfmadeupof18.5kWpowershelvesand1,200JperPSU(10xincrease)andRubinUltra+with110kWpowershelfx6andintegrated5integrated16kWBBUs.The110kWpowershelfis3RU(3.3xthe33kWlevelofBlackwellinthesamespace)forthe400-480kWinputvoltageconversionto52-54Vwith12Vand6Ampsstandbyvoltageandcurrentand1,200Jenergybuffertoflattentheinputcurrentperfectly.

Gridtochippowersolutions.Deltamappedoutthepowerconversionforthedatacenter.Thepowerisdeliveredfromthegridat34.5kVACfromthegridtotransformertostepdownto400-480VACintoanATSmodule,storedasACtoACintheUPSmodulebackedbyLi-Ionbatteries,thendeliveredtoapowerdistributionunittothepowershelvestoformtheconversionfromACtoDCandthenonvoltageregulatormodulesmaketheconversiondownfrom50Vto6/12Vto1Vonthecomputeboard.

Optionstosmoothoutthecurrent-highenergypowersupplyunitanew

solutiontosmoothvoltage.Oneoptionforasmoothcurrentistoaddanoptionalpowercapunit(PCS)orcapacitorback-upunit(CBU)whichcanbehookeduptosmooththeinputoftheACpower.Itdoeshavedisadvantageofconsumingrackspaceandisalsoexternaltotherackwhichsometimeshasabitoflatency.TheotheroptionbeingpromotedbyDeltaistouseahighenergypowersupplyunitwhichadds16energystoragealuminumcapacitorsinthePSUandsoftwarecontroltosmooththehighfrequencydynamicloadandflattenthepowervariationsdeliveredtotheGPU.

Powershelvesunabletoscalefurtherup,requiringaseparatepowerrack.AtypicalAIracknowhas4powershelvesatthetopandbottomaroundthe18computetraysand9switchtrays.Thechallengescalingforwardisnoroomleftforadditionalshelves,batteryback-uporsupercapacitorPCSshelvestopowerbufferforsmoothpowertotheGPU.Thesolutionistheseparatepowerrackorsidecarcontainingpowershelf,powerdistributionunit,batteryback-upunitandcapacitorback-upunit.

Delta’s800VDC660kWpowersystemwithBBU.Deltaisqualifyingits660kWpowersystemthatcantake415-480VACpowerandconvertto800VDCpowerinaseparatesidecarnexttotherack.Thesystemcontains6110kW(6piecesof18.5kW)powershelves(660kWpower)and5shelveswith518kWbatteriesfor450kWback-uppower,hotpluggablepowersupplyandbatteryback-upand98%efficiencyinarackat600x1,200,2,235mmdimensions.Eachshelfis6Uhighwith3rowsofPSUsandDCfanforairflowand5rowsofBBUs.Forconversiontolowervoltageintherack,DeltaisalsoofferinganIT-racklevel800VDCto50Vconversionina1RUconceptthatoutputtoabusbarclipandcontrolledthroughEthernet.

Long-termevolutiontoaGWdatacenter.Delta’slong-termvisionfortheAIdata

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论