BMS_B Configuration_第1页
BMS_B Configuration_第2页
BMS_B Configuration_第3页
BMS_B Configuration_第4页
BMS_B Configuration_第5页
已阅读5页,还剩18页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

GE-FANUC SERIES 90-70 (v7.04) Page 1Auxiliary Boiler - Burner Management - B Processor Config.GGGG EEEEE FFFFF AAA N N U U CCCC G E F A A NN N U U C G GGG EEEE FFF AAAAA N N N U U C G G E F A A N NN U U C GGG EEEEE F A A N N UUU CCCC AAA U U TTTTT OOO M M AAA TTTTT IIIII OOO N N A A U U T O O MM MM A A T I O O NN N AAAAA U U T O O M M M AAAAA T I O O N N N A A U U T O O M M A A T I O O N NN A A UUU T OOO M M A A T IIIII OOO N N (*)( )( CENTRAL PLC CONFIGURATION )( )( )( TOTAL DISCRETE I/O (%I + %Q): 144 )( )( HIGHEST CONFIGURED REFERENCES )( - )( DISCRETE INPUT (%I) : 136 )( DISCRETE OUTPUT (%Q) : 16 )( )( ANALOG INPUT (%AI) : 0 )( ANALOG OUTPUT (%AQ) : 0 )( )( REGISTER MEMORY (%R) : 0 )( )(*)Folder: C:LM90BMS_B GE-FANUC SERIES 90-70 (v7.04) Page 2Auxiliary Boiler - Burner Management - B Processor Config. RACK 0 PS 1 2 3 4 5 6 7 8 9 = P R O G R A M M E D C O N F I G U R A T I O N = PWR711CGR 772BEM 713RCM 711BEM 731CMM 742 100W FLOAT XMTR RCM GBC1 ETHNET 512 KB DevicesRef Adr BUS: 2%I00057 Folder: C:LM90BMS_B RackGE-FANUC SERIES 90-70 (v7.04) Page 3Auxiliary Boiler - Burner Management - B Processor Config.SERIES 90-70 MODULE IN RACK 0 SLOT 0 SOFTWARE CONFIGURATION SLOT Catalog #: IC697PWR711 POWER SUPPLY 120/240 VAC 100W 0 PWR711 100W SERIES 90-70 MODULE IN RACK 0 SLOT 1 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CGR772 772 CGR REDUNDANT CPU 512K FXD 1 CGR 772 IOScan-Stop: NO Baud Rate : 19200 FLOAT Passwords : DISABLED Parity : ODD Redund Type: SECNDARY Stop Bits : 1 SFC Faults : DISABLED Data Bits : 8 Modem TT : 0 1/100 Second / Count 512 KB Idle Time : 10 Seconds Mode : SNP Watchdg Tmr: 200 msec Folder: C:LM90BMS_B SlotGE-FANUC SERIES 90-70 (v7.04) Page 4Auxiliary Boiler - Burner Management - B Processor Config.SERIES 90-70 MODULE IN RACK 0 SLOT 1 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CGR772 772 CGR REDUNDANT CPU 512K FXD 1 CGR 772 Sweep Mode : NORMAL Bkgnd Tmr : 5 msec FLOAT Prg Window : COMPLETE Prg Wnd Tmr: 255 msec Syscomm Mde: COMPLETE SysComm Tmr: 255 msec Chksum Wrds: 16 512 KB SERIES 90-70 MODULE IN RACK 0 SLOT 1 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CGR772 772 CGR REDUNDANT CPU 512K FXD 1 CGR 772 Ctrl Strgy : GHS FLOAT Fail Wait : 60 msec - SHARED I/O - Ref Adr : %I00001 LENGTH : 1024 512 KB Ref Adr : %Q00001 LENGTH : 1024 Ref Adr : %M00001 LENGTH : 2048 Ref Adr : %R00001 LENGTH : 1024 Ref Adr : %AI0001 LENGTH : 0 Ref Adr : %AQ0001 LENGTH : 0 Folder: C:LM90BMS_B SlotGE-FANUC SERIES 90-70 (v7.04) Page 5Auxiliary Boiler - Burner Management - B Processor Config.SERIES 90-70 MODULE IN RACK 0 SLOT 1 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CGR772 772 CGR REDUNDANT CPU 512K FXD 1 CGR 772 Port 1 Mode: SNP Port 2 Mode: SNP FLOAT SNP Mode : SLAVE SNP Mode : SLAVE Baud Rate : 19200 Baud Rate : 19200 Flow Contrl: N/A Flow Contrl: N/A Parity : ODD Parity : ODD 512 KB Stop Bits : 1 Stop Bits : 1 Timeout : LONG Timeout : LONG TurnA Delay: 0 TurnA Delay: 0 SNP ID : SNP ID : SERIES 90-70 MODULE IN RACK 0 SLOT 2 SOFTWARE CONFIGURATION SLOT Catalog #: IC697BEM713 BUS TRANSMITTER 2 BEM 713 Remote RCM : YES XMTR Rev A Bus Transmitter Module (IC697BEM713A) must be placed to the right of all modules that can generate interrupts in the main rack. Folder: C:LM90BMS_B SlotGE-FANUC SERIES 90-70 (v7.04) Page 6Auxiliary Boiler - Burner Management - B Processor Config.SERIES 90-70 MODULE IN RACK 0 SLOT 3 SOFTWARE CONFIGURATION SLOT Catalog #: IC697RCM711 REDUNDANT COMM MODULE 3 RCM 711 RCM SERIES 90-70 MODULE IN RACK 0 SLOT 5 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CMM742 ETHERNET I/F FOR 90-70 HI PERF 5 %I, %Q lengths are bits; %AI, %AQ, %R are words CMM 742 Config Mode : TCP/IP ETHNET Status Address : %I00057 Status Length : 80 IP Address : 192.168.101.92 Subnet Mask : 255.255.255.0 Gateway IP Address : 0.0.0.0 Name Server IP Address : 0.0.0.0 Network Time Sync : NONE Folder: C:LM90BMS_B SlotGE-FANUC SERIES 90-70 (v7.04) Page 7Auxiliary Boiler - Burner Management - B Processor Config.SERIES 90-70 MODULE IN RACK 0 SLOT 5 SOFTWARE CONFIGURATION SLOT Catalog #: IC697CMM742 ETHERNET I/F FOR 90-70 HI PERF 5 CMM 742 - PORT CONFIGURATION - ETHNET - Station Mgr Port - - S/W Load Port - Data Rate : 9600 Data Rate : 19200 Parity : NONE Parity : ODD Stop Bits : 1 Stop Bits : 1 Flow Contrl: NONE Flow Contrl: NONE TurnA Delay: NONE TurnA Delay: NONE Timeout : LONG Timeout : LONG Folder: C:LM90BMS_B SlotGE-FANUC SERIES 90-70 (v7.04) Page 8Auxiliary Boiler - Burner Management - B Processor Config.There are no GENIUS blocks configured in the Bus Address range 0. 7There are no GENIUS blocks configured in the Bus Address range 8. 15There are no GENIUS blocks configured in the Bus Address range 16. 23Rack 0 Slot 4 Bus 1 BUS ADR BUS ADR BUS ADR BUS ADR BUS ADR BUS ADR BUS ADR BUS ADR 24 25 26 27 28 29 30 31 BEM 733 BEM 731 BEM 731 REMSCAN GBC1 GBC1 DROP033 I/O MAP Devices %I00001 BUS: 2 %Q00001 Folder: C:LM90BMS_B BusGE-FANUC SERIES 90-70 (v7.04) Page 9Auxiliary Boiler - Burner Management - B Processor Config.Rack 0 Slot 4 Bus 1 SOFTWARE CONFIGURATION BUS ADR Catalog #: IC697BEM731 90-70 GENIUS BUS CONTROLLER 30 BEM 731 Bus #1 Addr: 30 Redund Mode: R

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论