慢性完全性闭塞的导丝技术介绍_第1页
慢性完全性闭塞的导丝技术介绍_第2页
慢性完全性闭塞的导丝技术介绍_第3页
慢性完全性闭塞的导丝技术介绍_第4页
慢性完全性闭塞的导丝技术介绍_第5页
已阅读5页,还剩67页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

Introduction wire techniques of chronic total occlusions,Jun Dai , M.D. Coronary disease center Fuwai Hospital CAMS & PUMC Beijing,Contents,Definition Pathology Angiography imaging PCI technical challenge guidewire technology interventional devices revascularization technology,Definition of CTO,Chronic total occlusions are defined as occlusions greater than 3(1) month old with angiographic TIMI 0 or TIMI 1 flow,The Spectrum of Lumen Morphology in CTO: Clinical Challenges,Necrotic core,Proteoglycan-rich,Calcification,Large recanalization channels,Inflammation,Small recanalization channels,Fibrotic plq: Negative remodelling,Chronic Total Occlusions,Whats Blocking up the Lumen? 1. Dense Fibrotic Tissue: COLLAGEN! 2. Calcification,Intraluminal Collagen,Extracellular Matrix: Collagen, Calcium,Increased fibrocalcific plaques with age Srivatsa et al, J Am Coll Cardiol 1997:29:955-63,Intraluminal Calcification,Variables related success,Age of Occlusion Entry Length Tortuousity Calcium Collaterals Distal Vessel Size In-stent occlusion devices,Anatomic Descriptors of Procedural Success,Anatomy of a CTO Guidewire,Guidewire Operator Techniques,Simplified “Lesion-Specific” CTO Guidewire Use Algorithms,CTO Guidewire Design,CTO Guidewire Categories,Anatomy of a CTO Guidewire,Guidewire Operator Techniques,Simplified “Lesion-Specific” CTO Guidewire Use Algorithms,CTO Guidewire Design,CTO Guidewire Categories,Hallmarks of a CTO Guidewire,Tip styles - core-to-tip designs; sometimes tapered Coils and covers - some favor increased radiopacity; jointless coils for improved torque response; polymer covers for selected applications Core tapers and materials - shorter tapers for improved torque response; generally stainless steel Core diameters - larger for increased support and torque response Coatings - hydrophilic for tracking (body) and hydrophobic for torque response (body and tip),ASAHI MIRACLEBROS Family Straight Tip Guide Wires,Characteristics: Core-to-tip design (unique wire drawing process) Non-tapered tip 11 cm of radiopacity Smooth tractability & delivery with Joint-less distal coil technology Hydrophobic coating Increasing tip loads 3 -12 gm Excellent tip shape ability & shape retention,ASAHI CONFIANZA 9 Tapered Tip Guide Wires,Characteristics: Very stiff tip 9 gm tip load Tapered tip - .009“ (for enhanced penetration) 20 cm radiopacitiy - Joint-less technology Hydrophobic coating,Hydrophilic Coating,0.014”,Radiopaque Spring Coil,0.008”,PTFE,ASAHI CONFIANZA Pro “8-20” Tapered Tip Guide Wire,Characteristics: Stiffest tip - 20 gm Tapered tip - .008“ 20 cm radiopacitiy Joint-less technology Hybrid coating,Greatest penetrating force,The combination of a polymer cover and hydrophilic coating provides outstanding lubricity.,Tip coils beneath the polymer help facilitate tip shaping.,HI-TORQUE PILOTTM Family of Guide wire,Cordis SHINOBI & SHINOBI Plus CTO Guidewires,Unique flattened tip designed to cross subtotal occlusions,Flattened radiopaque coils,.0070” Corewire Support,SHINOBI,.0100” Corewire Support,SHINOBI Plus,1. Coronary CTOs have many types of lesion morphologies.,Therefore, we have to use different types of wires for different lesion morphologies.,2. During a single CTO-PCI procedure, we often encounter different kinds of situations.,Therefore, we have to use a different type of wire for each situation.,Wire selection and wire handling,Guide Wire Selection,Most important considerations Torque response Tip feel (tactile response) Tip shape curve formation,Hydrophobic vs Hydrophilic Wires,Hydrophobic wires Provide better tactile response to operator Provide operator improved tactile response to better navigate micro-channels To get into the “dimple” and use tip load to purchase fibrous cap Hydrophilic wires Hydrophilic wires with tapered tip may improve the locating of micro-channels, however micro-channels can lead to false lumens/sub-intimal spaces Hydrophilic wires tend to follow the path of least resistance and generally offer less tip control,Simplifyed sequence of wires,Easy case ( big vessel, straight ) Crossit 100 Confianza pro,Difficult case (calcifyed, tortuous, smaller) Miracle 3g Prox. Tortuosity: lubricious wires Miracle 4.5-12 g Confianza wires,Parallel wire: Confianza 6g 12g,Why so difficult to cross it ?,Sub-Intimal Path,Wire technique for locating another channel Tip Shape Is Key,Wire tip for CTO,CTO,Stenosis,Tip 1 mm,Tip 2-3mm,Anatomy of a CTO Guidewire,Guidewire Operator Techniques,Simplified “Lesion-Specific” CTO Guidewire Use Algorithms,CTO Guidewire Design,CTO Guidewire Categories,Guidewire Operator Techniques,DRILLING (controlled),Guidewire Operator Techniques,Short tip curve ( 2mm) at 45-60o; sometimes a proximal secondary curve at 15-30o Controlled rotational tip motion with gentle forward probing Start with moderate stiffness tips and stepwise increases in tip stiffness Premium on tactile responses,PENETRATION,Guidewire Operator Techniques,Similar tip shape and curves as drilling technique Precise movements of the guidewire tip Minimal rotational tip motion with more aggressive directed forward probing Tip stiffness should penetrate even heavily calcified entry cap (9-12 gms and tapered) Reduced tactile responsiveness,Allways steer towards inner curve ! Twist gently , push and pull ! Dont inject dye via OTW-catheter !,In curved vessels, the optimal site for penetrating the fibrous cap is towards the myocardium (mural ),No !,Penetration vs. Controlled Drilling Drilling,Techniques of CTO Guidewire Manipulation,Techniques of CTO Guidewire Manipulation,Penetration vs. Controlled Drilling,Directional control of the tip is more precise in “Penetration”,Advancement of the tip is easier in “Controlled Drilling”,SLIDING,Guidewire Operator Techniques,Longer and shallower tip shapes and no secondary bends Simultaneous tip rotation and probing Almost no tactile response Takes advantage of reduced guidewire surface friction requires polymer cover,Anatomy of a CTO Guidewire,Guidewire Operator Techniques,Simplified “Lesion-Specific” CTO Guidewire Use Algorithms,CTO Guidewire Design,CTO Guidewire Categories,DRILLING (controlled),CTO Guidewire Categories,Abbott CROSS-IT wires (100, 200, and 300) Asahi-Abbott MIRACLE Bros wires Medtronic PERSUADER wires (3 and 6 gm),PENETRATION,CTO Guidewire Categories,Abbott CROSS-IT 400 wire Asahi-Abbott CONFIENZA wires (regular and PRO) - 9 and 12 gm Medtronic PERSUADER wire - 9 gm,SLIDING,CTO Guidewire Categories,Abbott PILOT and Whisper wires BSC PT wires Cordis SHINOBI wires Asahi Fielder wires,Anatomy of a CTO Guidewire,Guidewire Operator Techniques,Simplified “Lesion-Specific” CTO Guidewire Use Algorithms,CTO Guidewire Design,CTO Guidewire Categories,DRILLING (controlled),Lesion-Specific CTO Approaches,Most CTOs with discrete entry point; after initial attempt with soft (intermediate) wires “Workhorse” technique,PENETRATION,Lesion-Specific CTO Approaches,Blunt entry point Heavily calcified or resistant lesions Alternative to “drilling” as workhorse technique after initial soft wire failure,SLIDING,Lesion-Specific CTO Approaches,Microchannels present or sub-total occlusion (residual channel) ISR total occlusions Some calcified and angulated lesions STAR technique (subintimal reentry),Recent Guidewire Techniques,parallel wire techniques and extra support backup catheters Sesame open,Concept of Parallel Wire Technique,Tortuousity - Lesion on Bend,Seesaw: modifyed parallel wire technique,8 F guide 2 OTW balloons /catheters 2 wires slide parallel and are advanced in an alternating manner,Seesaw Wiring Parallel Wire Method with Double Support Catheters,marker,Seesaw Wiring,guide wires can exchange their roles as marker or penetrator,marker,CTO at branch: Sesame open (Saito),And entry can still not be found: Sidebranch technique (Katoh),Side Branch Technique,Anchoring technique using OTW balloon,Subintimal Tracking and Reentry (STAR) technique,Supportive 8Fr guide Create or use existing dissection in proximal CTO (Miracle, Confianza, etc.) 1.5mm balloon into track Whisper/Pilot 50 with tight “J” tip/”umbrella tip” Advance with balloon support, avoid spinning wire if possible May need pilot 150, 200 for proximal Use softest wire possible for distal (whisper) Reentry,Anterograde Dissection and Reentry,Subintimal Tracking and Reentry (STAR) Tips,Stiffer polymer wire (“J”) proximally if needed but always softer distally “J-bend” media-to-media diameter Runoff vessels are key Visualization of target/runoff vessels is key Reentry strategy Dont lose true lumen distal branch, multiple wires if necessary PTCA pre-stent conservative size, pressures 12 ATM Bifurcation stenting only if absolutely necessary SB dissections may be OK DES Consider angiographic followup,Subintimal Tracking and Reentry (STAR) Patient Selection,Failure with conventional wire strategies (parallel, see-saw) No retrograde opportunity Relatively healthy distal vessel beyond CTO Minimal important branches in shear/dissection zone (RCA, OM) Strong clinical indication This is final measure, not first measure,Interventional techniques Improvement about CTO,Miracale 1995 Conquest 1999 Parallel and seesaw 2000 IVUS guide 2001 STAR 2003 SHOOTING and Fielder 2005 Tornus 2005 CART 2005,Retrograde approach,Anterograde failure Best septal collateral 7F shorter guide catheter 70-90cm ACT300 seconds Microcathter softer and hydrophilic wire,CTO Guide Wire Considerations(1),Start with softer guide wires Consider hydrophilic for sub-total occlusions Consider hydrophilic for heavy calcium Otherwise, start with soft, hydrophobic wires Advance to stiffer wires carefully Consider parallel wire techniques if subintimal Hydrophobic wires offer best tactile feel of lesion,Entry,Unfavorable,Favorable,Stump; no entry point; wire will favor side-branch,Well defined nipple into which wire can be directed, MIRACLEbros Family Confianza Family,Better torque performance,Less torque performance,Less penetration force,Better penetration force,Better crushing force,Less crushing force,Better tactile feeling,Less tactile feeling,Common CTO wire characters(2), MIRACLEbros Family Confianza Family,to advance in the hard CTO with tortuosity,to penetrate proximal or distal cap (parallel),to puncture from pseudo to true lumen (IVUS guide).,to puncture from pseudo to true lumen.,is more controllable,should be used,to penetrate proximal or distal cap,only when the near target is detected, Confianza Family should not be used,to seek the true channel or advance over a long distance, particularly in CTO with tortuosity.,Common CTO wire characters(3),Support Catheters,1.5mm balloon Transit ILT support catheter Spectronetics Quick Cross St Judes Venture deflecting support catheter Tornus catheter,Facilitate wire exchange Improve to

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论