毕 业 设 计(论 文)外 文 参 考 资 料 及 译 文译文题目: 现浇钢筋混凝土箱梁的质量控制 学生姓名: 贾一凡 学号: 0706110339 专业: 土 木 工 程 所在学院: 建 筑 工 程 学 院 指导教师: 杜杨 职称 : 讲师 2011年 2 月 21 日Reinforced Concrete Quality Control Box 1, stent design and layout1.1 Ground handlin 30m width of the box within the soft bottom of all the excavation sites, the use of stone content of 60% or more of the sand and gravel (on rocks) replacement, cleaning up the hillside section of the hard rock surface, and set the cross slope, slope control in 3% range, to facilitate and remove rainwater.If the longitudinal slope is too large, way to set the stage for easy pad support pedestal formation. Upper reaches of the drainage ditch near the sidewalk excavation, lowering the water level elevation, in order to prevent rainwater and other water flows into the stent area, causing stent sink.1.2 bracket arrangement1.2.1 Scaffold Specifications Frame by frame button steel bowl, pole mainly 3.0m, 2.4m, 1.8m3 species, a long pole then staggered arrangement, plunger length 1.5m, 1.2m, 0.9m, bar with 0.9m, 0.6mtwo components, top and bottom with adjustable prop support care.1.2.2 support arrangement Box under the pole vertical distance 0.6m, horizontal distance 0.9m, horizontal and vertical bar step 0.6m, and set the scissors truss reinforcement. Stent Xiadian 15 15cm sleepers, pole adjustable pedestal support base located in the sleeper, the pole on the set adjusted backwater, backwater above the laying of 15 15cm square wooden horizontal, vertical laying of 10 10cm square of wood. Stand for the shape of Bowl bracket, first determine the initial installation, the installation location, and according to the starting height of the ground level to determine pole placement Sleepers, the use of adjustable elevation of the leveling will be the end of care, to avoid local grievances led to uneven vacant or under Poleuneven, the installation can be installed to take the first measurement of the ground segment elevation, according to the measured data to calculate the pole bottom level, first with the adjustable bottom bracket standard will be four corner pole hang after installation of high-profile flat other end of care, aftervertical mounting rails.Notes 1.2.3 stand arrangement (1) When the pole is greater than 60cm height difference between the base, then the pole can be used to adjust the wrong section. (2) take a long pole in the joints should be staggered, the first layer of 2.4m and 3.0m with long pole in the pole staggered arrangement, and both up the pole with 3.0m, 1.5m and 0.9 to the top and thenm length of the mandrel two leveling. (3) the degree of vertical pole should be strictly controlled: 15m shelf press the following 1 / 200 control, and the full height of the vertical deviation should be less than 10cm. (4) scaffolding assembled to 3 to 5 storeys, the horizontal bar with a theodolite check the verticality of the degree and the pole.In case of no load pole-by-check for loose or empty floating base, and to tighten the adjustable seat and promptly adjust the pad Sheet implemented. (5) braced grid should adapt with the size of the shelf.Diagonal brace for the pull bar, layout direction can be arbitrary.Under normal circumstances bracing should be connected to the node with the scaffolding, but also the wrong section layout. (6) diagonal brace layout density, when the scaffold height of less than 20m, in order to frame the whole area of 1 / 2 to 1 / 4, diagonal brace must be symmetrically arranged, and should be evenly distributed.Diagonal brace for strengthening the overall scaffold stiffness and load capacity in it should not be arbitrarily removed.1.3 support After laying support, the need for pre-press, to test the strength and foundation support and stability, to eliminate the plastic deformation of the entire frame, eliminating the foundation of the settlement, the elastic deformation measured stent. Pre-press materials woven bags of sand or water tanks, pre-stent pressure, pre-press load for the beam weight of 120%. Stent assembly according to the design when the vertical and horizontal distance from the pole arrangement, the top bracket by backwater leveling, the laying ofhorizontal and vertical square wooden board, installing water tanks, or bags of sand used cranes dipping pre-stent pressure. In the center of each segment, lateral left and right side cloth 3 points for observation in the pre-pressure die before the end of the elevation of observations 1, in the process of preloading every 2h observation 1, observation date to the settlement and stability,unloading after the pre-load pressure on the Elevation of the end of observation 1, observation from the above data to calculate the elastic deformation and foundation support the sink. Preloading accurate measurement of the process can be measured under the load support beam section will have a value of elastic deformation and ground subsidence, this elastic deformation, ground subsidence and construction of control because of other factors need to put forwardcamber settings overlay, calculated construction camber should be used, according to the calculated camber adjustment Elevation of the bottom.Also note the outside of the stent at 2m temporary protective facilities to prevent water and rain water into the stent area, causing stent sink.Preloading completed, remove the tank or adjust the pole height of sand bags.1.4 Construction of pre-camber In determining the camber should consider the following factors: the box itself and after unloading planes live load vertical deflection produced by half; stent in the elastic compression loads; bracket under load of non-elastic deformation, the bracket baseloads of non-elastic subsidence; temperature changes caused by the deflection; caused by the concrete creep and creep deflection. According to the deflection and deformation of the stent camber calculated from the sum, as the highest camber, set in the mid-point of the beam span.Other points of camber to the midpoint of the highest value to both ends of the beam elastic deformation of the Ministry for the stent, according to the distribution of quadratic parabola.Calculated from the box under the bottom elevation of the box after preloading to re-adjust the Elevation of the bottom. 2, template fabrication and installation2.1 templates to create and install (1) the end of the template used chunk of plywood, shop at the top of longitudinal frame of wood, the wood and plywood with a nail fixed, transfer mode, complete the unloading mode with adjustable backwater. (2) outside the template within 5cm Heavy plate after polishing paste = 12mm 15mm bamboo, vertical spacing of 90cm set square wooden support rib, lateral distance of 50cm set channel support ribs.Stand outside the direct distribution of the beam mode, when assembled within the outer after the template on the pull with the screw on the pull-18. (3) The combination of steel used within the model, the local size change using wooden mold, the template is mainly used for pulling the fastening screw, and connected with the scaffold.Roof used in the steel box girder formwork support, direct support in the bottom bracket. (4) Plug the template due to perforation of reinforced and prestressed in the template using plywood digging holes, dug by cutting section size, perforation of reinforced and prestressed pipe must be precisely positioning the cutting.2.2 Template Installation Notes (1) Production of a template before the first familiar with the parts drawing and template processing maps, engineering structure or component to verify the detail size, complex structure should be like by zooming in order to proper preparation, processing and map production of the approved template, inspected and acceptedbefore use. (2) template to seal the joints, where the gap, the use of 107 plastic plug close to plasma leakage. (3) the arrangement of the bolt hole should be vertical and horizontal symmetry, a certain degree of regularity and decoration in good condition. (4) connecting seam tape adhesive template, templates, bent pitched complete acceptance of the invitation after the Commissioner of the next process. 3, steel processing and installation First test of reinforcing bars, meet the requirements for steel processing, welding the reinforced using double-sided welding, welding length of not less than 5d, smaller internal forces at the joint set, and staggered layout, welding joint area of not more than 50%.Based on the design drawings, will be reinforced in the next cutting plant material transported to the scene after the banding. Roof, floor, there are a large number of embedded web bellows, in order not to damage the bellows, welded bellows embedded all before, try not to weld pipe after installation, when the general location of steel bars and corrugated pipe into conflict whenMobile reinforcing bars, the appropriate and accurate positioning steel mesh installed to ensure accurate location of pipelines. Steel banding ago by surveyors retest the template location and elevation plane, which includes elevation calculated by the deflection of the hanger of the camber set, correct the rear of the steel banding. To enable accurate data protection layer, protective layer pads are not crushed, by setting plastic box pad pad construction. 4, bellows processing installation Position as shown in the drawings according to design layout bellows, and with the positioning ribs fixed, placed after the pipe must be smooth, non-chine. Length of all pipe joints 5d prevail, the use of corrugated pipe larger size socket to tighten the symmetry, and good joints wrapped with adhesive tape to prevent concrete slurry mixed with fine, when the pipeline location and conflict with non-prestressed reinforcement to takepipeline-based principles, the appropriate location of the mobile reinforcement to ensure that the correct pipe. Bellows the end of the embedded anchor plate should be perpendicular to the channel center line, and does not produce displacement during the concrete pouring.Bellows is installed, it will cover its end to prevent water or other debris to enter. Construction workers, mechanics, pipe vibrator can not crash. Before pouring concrete pipe carefully examined whether there are major holes in the pipe inspection, the joint is connected firmly, sealing, pipeline location is biased, strict check is correct, the method used air compressor ventilation pipe debris removal to ensure the smooth pipe. 5, Tongjiao Notes and health Used concrete pump concrete pumping, pouring time, first floor, after the web, and then the roof, symmetrical structure for each T, hierarchical placement, each 30cm, pouring from the front to the back end, the initial setting of the first layer of concretesub-layer before the completion of concrete placement, to ensure that no cold joints between layers, concrete vibrator vibrator in strict accordance with the role of scope, to prevent leakage pound, pound, and due to excessive vibration, when the prestressed pipe-intensive, gap hours, with a smalldiameter of 30 types of plug-in vibrators, vibrator in the steel must not drag on the flat, non-collision prestressed, template, reinforced; concrete vibrator for the first time after wiping flat surface, concrete roof should be a second hand side,the second hand side should be conducted before the initial setting of concrete, causing surface water to prevent the early dry, concrete pouring has been completed, covering wet sacks or straw bags for conservation. 6, tension and duct grouting6.1 La (1) Preparation of box pouring a sufficient quantity of test block with the conditions of health.Prestressing health conditions must be in the same strength of test block after 100% of design strength. (2) has a qualified team of prestressing operations to tension, tension before the tension response and the hydraulic jack used in precision control of the check table, calibration, and stretching equipment to uniform numbers.Sampling done on the strand and anchorage test. (3) before the clear face tension, pressure plates and steel beams twisted around the mortar, sampling tests according to relevant regulatory requirements on behalf of the actual channel friction parameters.Anchor fixture installation and check for compliance. (4) of the construction personnel are familiar with the technical training and equipment, operator certificates.Prestressing stress and tension by measuring elongation dual control method operation. (5) procedures for the prestressing: Install anchors and tensioning jack initial stress to initial control measure 15% con initial tensile elongation value to 100% con (holding charge 2min) content test and record the elongation value compared with the measured value is calculated Tensile elongation return oil from the anchor, jack Check out slide wire.The average tensile force calculation formula: Pp = P 1-e-(u + kx) / (kx + u)Theoretical value of elongation formula: L = Pp L / (Ag Eg) Tension during the measurement of each value by the person responsible, serious record, a reasonable calculation of the actual elongation value, the actual elongation value addition to measure, it should be coupled with the projected value when the initial stress:L0 = 0.15kL / (Ag Eg) Accurate calculation of each of the theoretical value of elongation of steel beams, carefully measure the actual elongation value of each beam.Prestressing stress and strain used double control, tension control that is standard under the premise of the stress, the actual elongation of steel beams were checked.Elongation values measured when the initial stress and the projected value and the theoretical value of elongation of the relative error of no more than 6%, if more than 6% to stop the tension, analyze the causes and take timely measures.6.2 Duct Grouting (1) grouting sequence.In principle, from one end to the other end of the grouting, when the pipeline when more than 35m, set the links in the pipeline, from one end to the three links grouting a slurry, and then from the links to the other end of the grouting, grouting in cycles. (2) Preparation before grouting.Air compressor blowing water pipelines; check the grouting materials used are complete enough; inspection equipment, tools are installed for good performance; check stand is solid, the effectiveness of safety facilities. (3) Grouting.Label according to the design requirements of laboratory prepared slurry, water slurry should adopt the ordinary portland cement, water-cement ratio of 0.4 to 0.45 between the control, consistency control of slurry between the 14s 18s.Grouting cement slurry mixing machine in the bucket for mixing the mortar, add water to the mixing machine first, and then into the cement, after mixing then add the full expansion agent, expansive agent dosage control in strict accordance with the ratio test,the total amount of cement generally do not exceed 0.01%. slurry ratio of 24h control the bleeding rate within 3%, less than 10% expansion rate control. Good mixing into the slurry from the mixing machine piston injection pump, the grouting from the box into one end, until the overflow from the vent hole until the consistency of a uniform slurry, grouting pipe valve closed until the slurry solidification,grouting pressure shall be controlled at 0.5MPa 0.7MPa. slurry from the mixing to the duration of pressure into the pore to control at 30min 45min range. Test in the whole grouting process must stand beside the record, and not less than 5 specimens from each working group classes 7.07 7.07 7.07cm slurry specimen, standard curing for 28 days to check the quality of its compressive strength as a slurryassessment basis.6.3 Anchor Anchor ring by cutting wheel machine outside the extra strand, and continue to sprinkle water to prevent heat transfer.Capping and cover casting concrete beams with the label, use is strictly prohibited in the casting process vibrated vibrated rods, tamping artificial smooth.Sprinkler after the final setting time of concrete curing, curing time of not less than 7 days.现浇钢筋混凝土箱梁的质量控制1、支架设计及布设1.1地基处理将箱梁下方30m宽度范围内松软地段全部挖除,采用含石量在60%以上的砂砾石(开山石)换填,山坡地段清理出坚硬的岩面,并设置横坡,坡度控制在3%范围内,便于及时排除雨水。如纵向坡度过大,采取设置台阶方式,便于底托支垫平整。上游靠近便道开挖水沟排水,降低水位标高,以防止雨水和其他水流入支架区,引起支架下沉。1.2支架布置1.2.1支架材料规格支架采用碗扣式钢管架,立杆主要采用3.0m、2.4m、1.8m3种,立杆接长错开布置,顶杆长度为1.5m、1.2m、0.9m,横杆采用0.9m、0.6m两种组成,顶底托采用可调托撑。1.2.2支架布置箱梁下立杆纵距0.6m,横距0.9m,横向及纵向横杆步距0.6m,并设置剪刀斜撑加固。支架下垫1515cm枕木,立杆底设可调底托支于枕木上,立杆上设可调顶托,顶托上方铺设1515cm横向方木,纵向铺设1010cm方木。碗扣支架为定型支架,安装时先确定起始安装位置,并根据地面标高确定立杆起始高度安放枕木,利用可调底托将标高调平,避免局部不平导致立杆不平悬空或受力不均,安装可采取先测量所安装节段地面标高,根据所测数据计算出立杆底面标高,先用可调底托将4个角标立杆高调平后挂线安装其他底托,后安装立杆。1.2.3支架布设注意事项 (1)当立杆基底间的高差大于60cm时,则可用立杆错节来调整。 (2)立杆的接长缝应错开,即第一层立杆应用长2.4m和3.0m的立杆错开布置,往上则均采用3.0m的立杆,至顶层再用1.5m和0.9m两种长度的顶杆找平。 (3)立杆的垂直度应严格加以控制:15m以下架子按1/200控制,且全高的垂直偏差应不大于10cm。 (4)脚手架拼装到35层高时,用经纬仪检查横杆的水平度和立杆的垂直度。在无荷载情况下逐个检查立杆底座有无松动或空浮情况,并及时旋紧可调座和薄钢板调整垫实。 (5)斜撑的网格应与架子的尺寸相适应。斜撑杆为拉压杆,布置方向可任意。一般情况下斜撑应尽量与脚手架的节点相连,但亦可以错节布置。 (6)斜撑杆的布置密度,当脚手架高度低于20m时,为整架面积的1/21/4,斜撑杆必须对称布置,且应分布均匀。斜撑杆对于加强脚手架的整体刚度和承载能力的关系很大,不应随意拆除。1.3支架预压支架铺设完毕后,需进行预压,以检验支架及地基的强度及稳定性,消除整个支架的塑性变形,消除地基的沉降变形,测量出支架的弹性变形。预压材料用编织袋装砂或水箱对支架进行预压,预压荷载为梁体自重的

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论