石径毕业设计计算书.doc

总建筑面积为3773.6平米5层教学楼(计算书、建筑、结构图)

收藏

资源目录
跳过导航链接。
压缩包内文档预览:

资源预览需要最新版本的Flash Player支持。
您尚未安装或版本过低,建议您

总建筑面积为3773.6平米5层教学楼(计算书、建筑、结构图),建筑面积,平米,教学楼,计算,建筑,结构图
编号:22378422    类型:共享资源    大小:6.10MB    格式:ZIP    上传时间:2019-10-16 上传人:乐****! IP属地:广东
15
积分
关 键 词:
建筑面积 平米 教学楼 计算 建筑 结构图
资源描述:
总建筑面积为3773.6平米5层教学楼(计算书、建筑、结构图),建筑面积,平米,教学楼,计算,建筑,结构图
内容简介:
PRESCRIPTIVE METHOD FOR RESIDENTIAL COLD-FORMEDSTEEL FRAMINGSecond EditionPrepared forThe U.S. Department of Housingand Urban Development Office of Policy Development and ResearchWashington, DCCo-Sponsored by The American Iron and Steel InstituteWashington, DCandThe National Association of Home BuildersWashington, DCbyNAHB Research Center, Inc.400 Prince Georges BoulevardUpper Marlboro, MD 20774-8731 August 1997CONTENTS5.0STEEL FLOOR FRAMING215.1Floor Construction215.2Floor to Foundation or Bearing Wall Connection215.3Allowable Joist Spans215.4Joist Bracing215.5Floor Cantilevers225.6Splicing225.7Framing of Floor Openings225.8Floor Trusses225.0STEEL FLOOR FRAMING5.1Floor ConstructionCold-formed steel framing members shall comply with the provisions of Section 2.0. Steel floors shall be constructed in accordance with this section and Figure 5.1.5.1.1Applicability LimitsThe applicability limits of Section 1.3 and Table 1.1 shall apply.5.1.2In-Line Framing. Load bearing steel floor framing, wall framing, and ceiling/roof framing shall be constructed in-line with the vertical load bearing members (i.e. studs) located below. A maximum tolerance of 3/4 inch (19 mm) between the centerlines of the in-line members shall be permitted in accordance with Figure 1.2.5.2Floor to Foundation or Bearing Wall ConnectionCold-formed steel floor framing shall be anchored to foundations, wood sills, or load bearing walls in accordance with Table 5.1 and Figures 5.1 through 5.10. Fastening of steel joists to other framing members shall be in accordance with Table 5.2. 5.3Allowable Joist SpansThe clear span of cold-formed steel floor joists shall not exceed the limits set forth in Table 5.3 for single spans and Table 5.4 for multiple spans. When continuous joist members are used for multiple spans, the interior bearing supports shall be located within two feet (0.6 m) of mid-span of the steel joists, and the individual spans shall not exceed the applicable spans in the table. Floor joists shall have a bearing support length of not less than 1.5 inches (38 mm) for exterior wall supports and 3.5 inches (89 mm) for interior wall supports. Bearing stiffeners shall be installed at each joist bearing location in accordance with Section 2.9. The thickness of joist tracks shall be a minimum of 33 mils (0.84 mm) thick except when used as part of floor header or trimmer in accordance with Section 5.7.5.4Joist BracingThe top flanges of floor joists shall be laterally braced by the application of floor fastened to the joists in accordance with Table 5.2. Floor joists with spans that exceed 12 feet (3.7 m) shall have the bottom flanges laterally braced in accordance with one of the following:1. Gypsum board installed with minimum#6 screws in accordance with the applicable building code, or2. Continuous steel strapping installed in accordance with Figure 5.1 and 5.2. Steel straps shall be at least 1-1/2 inches (38 mm) in width and 33 mils (0.84 mm) in thickness. Straps shall be fastened to the bottom flange of each joist with at least one #8 screw and shall be fastened to blocking with at least two #8 screws. Blocking or bridging (X-bracing) shall be installed between joists at a maximum spacing of 12 feet (3.7m) measured along the continuous strapping (perpendicular to the joist run). Blocking or bridging shall also be located at the termination of all straps.5.5 Floor CantileversFloor cantilevers for the second floor of a two-story building or the first floor of a one-story building shall not exceed 24 inches (610 mm) as illustrated in Figure 5.1. Cantilevers shall support interior floor loading only. Cantilevers, not exceeding 24 inches (610 mm) and supporting one floor and roof (first floor of a two story building), shall be permitted provided that all cantilevered joists are doubled (nested or back-to-back). The doubled cantilevered joists shall extend a minimum of 6 feet (1.8 m) toward the inside and shall be fastened with a minimum of two #8 screws spaced at 24 inches (610 mm) on center through the webs (for back-to-back) or flanges (for nested joists). Approved design is required for cantilevered areas supporting uniform live loads greater than 40 psf (1.92 kN/m2). 5.6SplicingJoists and other structural members shall not be spliced without an approved design. Splicing of tracks shall conform with Figure 5.11.5.7Framing of Floor OpeningsOpenings in floors shall be framed with header and trimmer joists. Header joist spans shall not exceed 8 feet (2.4 m) in length. Header and trimmer joists shall be fabricated from joist and track sections, which shall be of a minimum size and thickness as the adjacent floor joists and shall be installed in accordance with Figures 5.1, 5.12, and 5.13. Each header joist shall be connected to trimmer joists with a minimum of four 2 inch x 2 inch (51 mm x 51 mm) clip angles. Each clip angle shall be fastened to both the header and trimmer joists with four #8 screws evenly spaced on each leg of the clip angle. The clip angles shall have a thickness not less than that of the floor joist.5.8Floor TrussesCold-formed steel floor trusses shall be designed, braced, and installed in accordance with an approved design. Truss members shall not be notched, cut, or altered in any manner unless by an approved design. All trusses shall be aligned with load carrying members (i.e. studs) in the wall. Refer to AISI publication RG-9518 17 “Design Guide For Cold-Formed Steel Trusses” for additional guidance.Table 5.1Floor to Foundation or Bearing Wall Connection RequirementsFraming ConditionWind Speed (mph), Exposure, and Seismic Zones 1,2 Up to 90 A/B or 70 C or Seismic Zones 0, 1, 2, & 3Up to 110 A/B or 90 C or Seismic Zone 4Up to 110 CFloor joist to wall track of exterior steel load bearing wall per Figure 5.32 - #8 screws 3- #8 screws 4- #8 screws Joist track or end joist to bearing wall top track per Figure 5.31- #8 screw at 24 o.c1- #8 screw at 24 o.c.1- #8 screw at 12 o.c.Floor joist track or end joist to wood sill per Figure 5.4Steel plate spaced at 4 o.c. with 4-No. 8 screws and 4-10d or 6-8d common nailsSteel plate spaced at 2 o.c. with 4-No. 8 screws and 4-10d or 6-8d common nailsSteel plate spaced at 1 o.c. with 4-No. 8 screws and 4-10d or 6-8d common nailsFloor joist track or end joist to foundation per Figure 5.51/2 minimum diameter anchor bolt and clip angle spaced at 6 o.c. with 8- #8 screws1/2 minimum diameter anchor bolt and clip angle spaced at 4 o.c. with 8- #8 screws 1/2 minimum diameter anchor bolt and clip angle spaced at 2 o.c. with 8- #8 screws Cantilevered joist to foundation per Figure 5.61/2 minimum diameter anchor bolt and clip angle spaced at 6 o.c. with 8- #8 screws1/2 minimum diameter anchor bolt and clip angle spaced at 4 o.c. with 8- #8 screws 1/2 minimum diameter anchor bolt and clip angle spaced at 2 o.c. with 8- #8 screws Cantilevered joist to wood sill per Figure 5.7Steel plate spaced at 4 o.c. with 4-No. 8 screws and 4-10d or 6-8d common nailsSteel plate spaced at 2 o.c. with 4-No. 8 screws and 4-10d or 6-8d common nailsSteel plate spaced at 1 o.c. with 4-No. 8 screws and 4-10d or 6-8d common nailsCantilevered joist to wall track per Figure 5.81/2 minimum diameter anchor bolt and clip angle spaced at 6 o.c. with 8- #8 screws 1/2 minimum diameter anchor bolt and clip angle spaced at 4 o.c. with 8- #8 screws 1/2 minimum diameter anchor bolt and clip angle spaced at 2 o.c. with 8- #8 screws For SI:1 inch = 25.4 mm, 1 psf = 0.0479 kN/m2, 1 mph = 1.61 km/hr, 1 foot = 0.3m.1Use the highest of the wind speed and exposure or the seismic requirements for a given site.2All screw sizes shown are minimum Table 5.2Floor Fastening Schedule1Description of Building ElementsNumber and Size of FastenersSpacing of FastenersFloor joist to track of an interior load bearing wall per Figures 5.9 and 5.102 - #8 screwsEach joistFloor joist to track at end of joist2- #8 screwsOne per flange or two per bearing stiffenerSubfloor sheathing to floor joists#8 screws26 inches on center on edges and 10 inches on center at intermediate supportsFor SI:1 inch = 25.4 mm1All screw sizes shown are minimum.2Head styles shall be bugle-head, flat-head, or similar with a minimum head diameter of 0.29 inch(7 mm). Table 5.3Allowable Spans For Cold-Formed Steel Floor Joists1,2,3,4Single Span33 ksi SteelNominal Joist30 psf Live Load40 psf Live LoadSize 5 SSpacing (inches)Spacing (inches)1216241216242 x 6 x 3311-710-79-110-79-78-12 x 6 x 4312-811-610-011-610-59-12 x 6 x 5413-712-410-912-411-29-92 x 6 x 6814-613-211-613-212-010-62 x 6 x 9716-114-712-914-713-311-72 x 8 x 3315-813-38-1014-010-77-12 x 8 x 4317-115-613-715-614-112-32 x 8 x 5418-416-814-716-815-213-32 x 8 x 6819-817-1115-717-1116-314-22 x 8 x 9721-1019-1017-419-1018-015-92 x 10 x 4320-618-815-318-816-813-12 x 10 x 5422-120-117-620-118-315-112 x 10 x 6823-821-618-1021-619-717-12 x 10 x 9726-423-1120-1123-1121-919-02 x 12 x 4323-520-314-120-1116-1011-32 x 12 x 5425-923-419-723-421-317-62 x 12 x 6827-825-121-1125-122-1019-112 x 12 x 9730-927-1124-527-1125-422-2For SI: 1 inch = 25.4 mm, 1 psf = 0.0479 kN/m2, 1 foot = 0.3m.1Table provides the maximum clear span in feet and inches.2Bearing stiffeners shall be installed at all support points and concentrated loads.3Deflection criteria: L/480 for live loads; L/240 for total loads.4Floor dead load = 10 psf (0.479 kN/m2)5For actual size refer to Table 2.1. Table 5.4Allowable Spans For Cold-Formed Steel Floor Joists1,2,3,4,5,6Multiple Spans33 ksi SteelNominal Joist30 psf Live Load40 psf Live LoadSize 7Spacing (inches)Spacing (inches)1216241216242 x 6 x 3312-1010-67-1011-09-06-72 x 6 x 4315-813-611-014-012-19-102 x 6 x 5417-715-312-515-913-811-22 x 6 x 6819-617-214-017-815-412-62 x 6 x 9721-719-716-819-717-1014-112 x 8 x 3312-910-27-110-98-65-82 x 8 x 4319-516-812-617-514-310-82 x 8 x 5423-019-1116-320-617-914-62 x 8 x 6825-1022-518-323-220-016-42 x 8 x 9729-426-721-1126-724-019-72 x 10 x 4320-316-512-117-313-1110-22 x 10 x 5425-622-118-022-1019-915-62 x 10 x 6830-626-521-727-423-819-32 x 10 x 9735-431-925-1132-128-523-22 x 12 x 4319-815-911-316-713-39-02 x 12 x 5427-823-917-1024-920-415-22 x 12 x 6832-728-323-029-225-320-72 x 12 x 9741-336-729-1037-532-926-9For SI: 1 inch = 25.4 mm, 1 psf = 0.0479 kN/m2, 1 foot = 0.3m.1Table provides the maximum clear span in feet and inches to either side of the interior support.2Interior bearing supports for multiple span joists shall consist of structural (bearing) walls or beams.3Bearing stiffeners shall be installed at all support points and concentrated loads.4Deflection criteria: L/480 for live loads; L/240 for total loads.5Floor dead load = 10 psf (0.479 kN/m2)6Interior supports shall be located within two feet (610 mm) of mid span provided that each of the resulting spans does not exceed the appropriate maximum span shown in the table above.7 For actual size refer to Table 2.1.冷弯型钢框架结构设计方法第二版为美国住房发展政策开发部门和华盛顿研究中心所准备由美国华盛顿钢铁研究所联合主办国家建筑协会,华盛顿NAHB研究中心,乔治王子的大道400号Marlboro.MD 20774-87311997.8目录5.0 钢楼板结构215.1 楼板结构215.2 楼板与基础或承重墙连接215.3安装托梁的允许间距215.4托梁支撑215.5 悬臂楼板225.6 接合22 5.7开洞楼板框架225.8 楼板桁架225.0钢楼板结构5.1 建筑楼板 冷弯钢结构应该符合2.0部分提供的要求。钢楼板应该按图5.1的标准来修建。5.1.1适用性极限适用性极限应该参考第1.3部分和表1.1。5.1.2 线性结构承重的钢楼板和屋顶应建造时应和竖向荷载的大小紧密联系。轴线的最大的容许间距是3/4英寸(19mm)在图1.2中是可以的。5.2 楼板与基础或承重墙连接 冷弯钢结构楼板和基础、木基石或者承重墙的锚固长度参考表5.1或者图5.1。钢托梁和其他框架的锚固参考表5.2。5.3 允许的安装托梁间距冷弯钢楼板托梁的净跨在单跨时不应超过表5.3所规定的极限跨度,多跨时不应超过表5.4所规定的极限跨度。当连续的托梁用到多跨时,跨中支座应该被固定在2英尺内,并且其余个跨跨距不应超过表中所要求的长度。楼板托梁在外墙上的支撑长度至少为1.5英寸,在内墙上的支撑长度不应少于3.5英寸。根据第2.9部分,每个托梁必须安装受力钢筋。除了用在板头时根据第5.7结选取,托梁的最厚处至少应该是33米尔。5.4 安装托梁支撑根据表5.2,托梁的顶端应该被楼板的侧面支撑。根据下面的要求,楼板托梁当超过12英尺时应该有底面侧向的支撑。1根据建筑条例石膏板和直径最小为#6的螺丝安装时,或者2 连续的钢约束安装应根据图5.1和5.2。当托梁厚度为33米尔时钢约束的长度至少为11/2英寸。托梁的底部应该至少安装1个#8的螺丝,挡板必须安装2个#8的螺丝。固结并且最大跨度为12英尺时必须安装挡板。每个约束的端点处也必须安装挡板。5.5 楼板悬臂像图5.1表示的那样,两层楼的第二层或者单程楼的第一层的悬臂楼板不应超过24英寸。悬臂只支撑内楼板荷载。不超过24英寸并且支撑一层楼面或屋顶(两层楼的第一层)的悬臂,悬臂的托梁应该被容许加倍。跨度为24英寸的加倍的悬臂托梁必须向内深入至少6英尺并且用#8的螺丝加固。活载大于192 kN/m2时的悬臂是必须得到批准才能设计的。5.6 接合托梁和其他结构构件在没有设计容许时是不能接合的。轨道接合参照图5.11。5.7楼板开口的框架托梁接头的长度不应超过8英尺。在安装时托梁的接头的最小尺寸和厚度应该遵循图5.1,5.2,5.13。每个托梁的顶部应该以不低于四个2英寸2英寸的构件和托梁连接。每个构件应该和托梁的顶部连接时用四个#8的螺丝甚至在构件的每个角上。构件的厚度不应小于托梁的。5.8 楼板桁架冷弯钢楼板桁架必须按照有效的方案来进行设计和安装。在没有设计批准时,每个桁架处不应被刻痕、截断、或者替换。每个桁架应该与墙内承载荷载构件共同排列。参考ASIS出版的“冷弯钢桁架设计指南”表 5.1基础或承重墙所地板的连接要求结构情况风速 (mph), 暴露,地震地区1,2地震 A/B地区 90以下或者C地区70以下 地震 A/B地区 110以下或者C地区90以下110 C以下钢结构墙的地板托梁承载能力 2 - #8 螺丝3- #8螺丝4- #8螺丝墙顶部的绗架轨道或顶部轨道如图5.31- #8且螺丝间距为24 o.c1- #8且螺丝间距为24 o.c.1-#8且螺丝间距为 12 o.c.楼托梁轨道或木梁底轨道如图5.4钢板间隔为4 o.c 的用4-个 8 号螺丝和 4-10个6-8d普通钉子钢板间隔 2 o.c 用4-个 8 号螺丝和 4-10个6-8d普通钉子钢板间隔1 o.c 用4-个 8 号螺丝和 4-10个6-8d普通钉子楼托梁轨道 或基础托梁末端如图5.5最小锚杆直径为1/2的 和修正的角度为6o.c.的用8- #8螺丝最小锚杆直径为1/2 和修正的角度为4o.c的用8- #8螺丝最小锚杆直径为1/2 和修正的角度为2o.c.的用8- #8螺丝基础的悬臂托梁如图5.6 最小锚杆直径为1/2的 和修正的角度为6o.c.的用8- #8螺丝最小锚杆直径为1/2 和修正的角度为4o.c的用8- #8螺丝最小锚杆直径为1/2 和修正的角度为2o.c.的用8- #8螺丝木的悬臂托梁如图5.7钢板间隔为4 o.c 的用4-个 8 号螺丝和 4-10个6-8d普通钉子钢板间隔 2 o.c 用4-个 8 号螺丝和 4-10个6-8d普通钉子钢板间隔1 o.c 用4-个 8 号螺丝和 4-10个6-8d普通钉子木轨道的悬臂托梁如图5.8最小锚杆直径为1/2的 和修正的角度为6o.c.的用8- #8螺丝最小锚杆直径为1/2 和修正的角度为4o.c的用8- #8螺丝最小锚杆直径为1/2 和修正的角度为2o.c.的用8- #8螺丝注明 :1 英寸 = 25.4 mm, 1 psf = 0.0479 kN/m2, 1 mph = 1.61 km/hr, 1 foot = 0.3m.1表中所给的尺寸都是根据最高的风速和递增影响下得出的2所有螺丝给出的均是最小限值 表 5.2楼板固定表建筑外形连接件的尺寸和类型连接件间距托梁在承重结构的内部2 - #8螺丝每个托梁楼板在托梁末端2- #8 螺丝每个加固结构两个底层楼板在托梁的上端#8 螺丝支撑中间和边缘的间距6英尺 主要支撑的中心间距10英尺注明:1英寸= 25.4 毫米1所有螺丝给出的均是最小限值2螺丝顶部的形状应该是 喇叭型, 扁平型, 或最小直径是0.29英寸(7 mm). 表 5.3冷弯薄壁型钢的容许间距1,2,3,4单一间距33 ksi Steel托梁型号活载 30 pft活载 40pft尺寸 5 S间距 (英寸)间距 (英寸)1216241216242 x 6 x 3311-710-79-110-79-78-12 x 6 x 4312-811-610-011-610-59-12 x 6 x 5413-712-410-912-411-29-92 x 6 x 6814-613-211-613-212-010-62 x 6 x 9716-114-712-914-713-311-72 x 8 x 3315-813-38-1014-010-77-12 x 8 x 4317-115-613-715-614-112-32 x 8
温馨提示:
1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
2: 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
3.本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
提示  人人文库网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
关于本文
本文标题:总建筑面积为3773.6平米5层教学楼(计算书、建筑、结构图)
链接地址:https://www.renrendoc.com/p-22378422.html

官方联系方式

2:不支持迅雷下载,请使用浏览器下载   
3:不支持QQ浏览器下载,请用其他浏览器   
4:下载后的文档和图纸-无水印   
5:文档经过压缩,下载后原文更清晰   
关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

网站客服QQ:2881952447     

copyright@ 2020-2025  renrendoc.com 人人文库版权所有   联系电话:400-852-1180

备案号:蜀ICP备2022000484号-2       经营许可证: 川B2-20220663       公网安备川公网安备: 51019002004831号

本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知人人文库网,我们立即给予删除!