



全文预览已结束
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
TD SX460 GB 05 03 02 SX460 AUTOMATIC VOLTAGE REGULATOR AVR SPECIFICATION INSTALLATION AND ADJUSTMENTS General description Technical specification SX460 is a half wave phase controlled thyristor type Automatic Voltage Regulator AVR and forms part of the excitation system for a brush less generator In addition to regulating the generator voltage the AVR circuitry includes under speed and sensing loss protection features Excitation power is derived directly from the generator terminals Positive voltage build up from residual levels is ensured by the use of efficient semiconductors in the power circuitry of the AVR The AVR is linked with the main stator windings and the exciter field windings to provide closed loop control of the output voltage with load regulation of 1 5 In addition to being powered from the main stator the AVR also derives a sample voltage from the output windings for voltage control purposes In response to this sample voltage the AVR controls the power fed to the exciter field and hence the main field to maintain the machine output voltage within the specified limits compensating for load speed temperature and power factor of the generator A frequency measuring circuit continually monitors the generator output and provides output under speed protection of the excitation system by reducing the output voltage proportionally with speed below a pre settable threshold A manual adjustment is provided for factory setting of the under frequency roll off point UFRO This can easily be changed to 50 or 60 Hz in the field by push on link selection Provision is made for the connection of a remote voltage trimmer allowing the user fine control of the generator s output INPUT Voltage Jumper selectable 95 132V ac or 190 264V ac Frequency 50 60 Hz nominal Phase 1 OUTPUT Voltage max 90V dc at 207V ac input Current continuous 4 A dc Intermittent 6 A for 10 secs Resistance 15 ohms minimum REGULATION 1 5 see note 1 THERMAL DRIFT 0 05 per deg C change in AVR ambient note 2 TYPICAL SYSTEM RESPONSE AVR response 20 ms Filed current to 90 80 ms Machine Volts to 97 300 ms EXTERNAL VOLTAGE ADJUSTMENT 10 with 1 k ohm 1 watt trimmer see note 3 UNDER FREQUENCY PROTECTION Set point 95 Hz see note 4 Slope 170 down to 30 Hz UNIT POWER DISSIPATION 10 watts maximum BUILD UP VOLTAGE 4 Volts AVR terminals ENVIRONMENTAL Vibration 20 100 Hz 50mm sec 100Hz 2kHz 3 3g Operating temperature 40 to 70 C Relative Humidity 0 70 C 95 see note 5 Storage temperature 55 to 80 C NOTES 1 With 4 engine governing 2 After 10 minutes 3 Applies to Mod status F onwards Generator de rate may apply Check with factory 4 Factory set semi sealed jumper selectable 5 Non condensing DESIGN DETAIL TD SX460 GB 05 03 02 The main functions of the AVR are Potential Divider and Rectifier takes a proportion of the generator output voltage and attenuates it This input chain of resistors includes the range potentiometer and hand trimmer which adjust the generator voltage A rectifier converts the a c into d c for further processing The Amplifier Amp compares the sensing voltage to the Reference Voltage and amplifies the difference error to provide a controlling signal for the power devices The Ramp Generator and Level Detector and Driver infinitely control the conduction period of the Power Control Devices and hence provides the excitation system with the required power to maintain the generator voltage within specified limits The Stability Circuit provides adjustable negative ac feedback to ensure good steady state and transient performance of the control system The Low Hz Detector measures the period of each electrical cycle and causes the reference voltage to be reduced approximately linearly with speed below a presettable threshold A Light Emitting Diode gives indication of underspeed running The Synchronising circuit is used to keep the Ramp Generator and Low Hz Detector locked to the generator waveform period The Low Pass Filter prevents distorted waveforms affecting the operation of the AVR Power Control Devices vary the amount of exciter field current in response to the error signal produced by the Amplifier Suppression components are included to prevent sub cycle voltage spikes damaging the AVR components and also to reduce the amount of conducted noise on the generator terminals The Power Supply provides the required voltages for the AVR circuitry Suppression Low Pass Filter Synchronising Ciruit Low Hz Detection Power Control Devices Level Detector Driver Reference Voltage Stability Circuit Potential Divider Rectifier Power supply Ramp Generator Generator Amp Voltage Sensing Hand Trimmer Exciter Field FITTING AND OPERATING TD SX460 GB 05 03 02 SUMMARY OF AVR CONTROLS CONTROL FUNCTION DIRECTION VOLTS TO ADJUST GENERATOR OUTPUT VOLTAGE CLOCKWISE INCREASES OUTPUT VOLTAGE STABILITY TO PREVENT VOLTAGE HUNTING CLOCKWISE INCREASE THE DAMPING EFFECT UFRO TO SET THE UFRO KNEE POINT CLOCKWISE REDUCES THE KNEE POINT FREQUENCY ADJUSTMENT OF AVR CONTROLS VOLTAGE ADJUSTMENT The generator output voltage is set at the factory but can be altered by careful adjustment of the VOLTS control on the AVR board or by the external hand trimmer if fitted Terminals 1 and 2 on the AVR will be fitted with a shorting link if no hand trimmer is required Terminals L and L are linked only for special low voltage applications CAUTION Do not increase the voltage above the rated generator voltage If in doubt refer to the rating plate mounted on the generator case CAUTION Do not ground any of the hand trimmer terminals as these could be above earth potential Failure to observe this could cause equipment damage If a replacement AVR has been fitted or re setting of the VOLTS adjustment is required proceed as follows CAUTION 1 Before running generator turn the VOLTS control fully anti clockwise 2 Turn remote volts trimmer if fitted to midway position 3 Turn STABILITY control to midway position 4 Connect a suitable voltmeter 0 300V ac across line to neutral of the generator 5 Start generator set and run on no load at nominal frequency e g 50 53Hz or 60 63Hz 6 If the red Light Emitting Diode LED is illuminated refer to the Under Frequency Roll Off UFRO adjustment 7 Carefully turn VOLTS control clockwise until rated voltage is reached 8 If instability is present at rated voltage refer to stability adjustment then re adjust voltage if necessary 9 Voltage adjustment is now completed VOLTS F2 F1 6 7 8 L L 3 2 1 60 C 50 UFRO Under Frequency Roll Off INDICATOR LED STABILITY FREQUENCY SELECTION SX460 REFER TO GENERATOR WIRING DIAGRAM FOR CONNECTION DETAILS FITTING AND OPERATING TD SX460 GB 05 03 02 PO Box 17 Barnack Road Stamford Lincolnshire PE9 2NB Tel 00 44 0 1780 484000 Fax 00 44 0 1780 484100 Website www newage 2003 Newage International Limited Reprinted with permission of N I only Printed in England STABILITY ADJUSTMENT The AVR includes a stability or damping circuit to provide good steady state and transient performance of the generator The correct setting can be found by running the generator at no load and slowly turning the s
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 公司环境与安全培训课件
- 行政人事转正工作总结
- 卤菜店铺转让合同6篇
- 新农村建设工作总结
- 《祖国在我心中》课件
- 2025建筑施工租赁合同范本
- 解读义务教育均衡发展
- 第二季度护理工作总结
- 广东省肇庆市德庆县2022-2023学年高三上学期期中考试地理题库及答案
- 广东省汕头市金平区2023-2024学年高二上学期第二次月考思想政治试题及答案
- (2025年标准)教师定岗协议书
- 8 回忆鲁迅先生(课件)语文统编版2024八年级上册
- 2025年蜀道投资集团有限责任公司招聘笔试备考题库附答案详解(达标题)
- 美术基础 课件 第1、2章 美术简介;素描
- 2025年廉价航空行业研究报告及未来发展趋势预测
- 新能源企业盈利能力分析-以比亚迪股份有限公司为例
- 国家奖学金申请答辩汇报
- 2025年“学宪法讲宪法”知识竞赛题库含答案
- 2024年辽宁省地矿集团招聘真题
- 2025年绿化工技师试题及答案
- 【《基于哈佛分析框架的爱尔眼科公司财务分析(数据图表论文)》13000字】
评论
0/150
提交评论