全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
NMR FacilityEquipment Protocols - NMRINOVA-399Collect a 1D 1H spectrum Log in Click the Vnmr icon Lock, shim and collect a 1D 1H spectrumtype gain? and write down the gain value Set temperature and spin go to start tab and spin/temp move slider to desired temperature (must be greater than room temperature) move spin slider to 0 and press spin off (make sure spin goes off) Get pulse sequence and optimize parameterstype Doneshot (or any of the other DOSY experiments)go to start tab and give file namecheck solvent change gain to the value found above by typing gain=# type gzlvl1=5000,15000,23000 type gatype nt=8set delay to 10s when data collection is finished type dssh to see all datatype ds(1)type f full*WARNING Poor signal to noise can result in incorrect diffusion values (high)*tupe aph type dsshmake sure that the last data set has about 5% -15% of the S/N as the first data setif there is not sufficient delay increas gt1 or del (type del? to find current value then increase a little- type ga to try again) Collect dosy datatype setup_dosyanswer: 30 500023000make sure spinner is off (press acqi press lock press spin off)type gawait for data collection to finishSAVE THE DATA by pressing the acquire tab, future actions and save fid nowData processing Press Main menu Dataand find and load the datatype fn=100000type wfttype ds(1)type f fulltype aph0 (if spectrum needs phase correction)integrate spectrumtype fbctype dosy or press calculate entire dosynote down the values for each resonance. The diffusion coefficient reported is the center of the peakand the error bar is half the width of the widest peak- up to 20% error is acceptableTrouble shooting and hintsCommon data collection problems:1) do not get decay down to 15%:adjust diffusion delay or gradient diffusion length (*careful adjusting the length- too long of a length can fry the probe) adjust these two in very increments (increase gt1 by .001 and del by .01) if you do not get all the way down to 15% you will not have a well defined curve and your signal will be broad2) data does not decay in a linear fashion:maybe too much gt- try lowering gt and raising delay (so you still get 15%) but be careful because raising the delay introduces additional error signals have weird phase problems there may be a temperature gradient across the sample- try turning heater off you may have a system in chemical exchange- this make DOSY very tricky and usual fails gt1 and del are wrong- try lowering del and increasing gt1 4) too wide a spread of diffusion rates from the same compound:increase d1 value (calculated rate depends on T1) but keep the D1 delay as short as possible- too long of a delay the greater the band of diffusion rates for different protons if you need a tighter band you need to try greater gradient strength spread or try using inept (very insnesitive)note: a compound moving in and out of a gel will have a wider band for different protons on the same molecule could be .4 m2/s difference in diffusion rates- not surprising- should be smaller difference if the same compound were free in solution5) final signal too broad (too big of an error):sample volume may be too much- the more sample volume the less EVEN the gradient along the Z axis will beCommon data processing problems: 1) Program bombs: check line broadening- it cannot be zero- should be 3-5 program will bomb if there is insufficient signal to noise peaks do not phase well and there is significant signal below the baseline-see Spectrum-does not phase (above) 2) Need to run fiddleplace cursor on reference peak ( a nice clean singlet)and type rlpress Ref and give it the correct reference value for that peakpress Th and move threashold close to baselinepress fullplace cursors on either side of the reference peaktype lb=-4 gf=.05make sure full spectrum is on the screentype fiddle(writefid,filename) and wait till it corrects every spectrumwritefid is types exactly and filename is a file you are going to write the data tointegrate each individual peak you want to include in the DOSY analysismake sure full spectrum is on the screenmake sure that threashold line is on screen and cursors suround reference peaktype fbctype dosy or press calculate entire dosyUncommon problems:1) full range of rates is not covered:you many need to recalibrate gcal for the probe2) one of the spectra does not phase well:remove that spectrum3) signal do not phase well:check to see that the solvent is correct- it must know the correct solvent since the 90s for each solvent are different in the probe file and the 90 being off will effect whethe
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026年陕西省选调生招录备考题库(面向中国政法大学)附答案详解
- 2026中国储备粮管理集团有限公司吉林分公司招聘备考考点题库及答案解析
- 2025重庆市永川区陈食街道办事处非全日制公益性岗位招聘1人备考题库(含答案详解)
- 2026广东深圳证券交易所人员招聘参考模拟试题及答案解析
- 2026年陕西省选调生招录备考题库(面向陕西师范大学)及一套完整答案详解
- 2026农银人寿保险股份有限公司校园招聘71人备考题库附答案详解(综合卷)
- 2025贵州安顺镇宁县总工会招聘工会社会工作者2人备考题库及答案详解(易错题)
- 2025四川凉山金阳县招聘社区专职工作者10人备考题库附答案详解(能力提升)
- 2025山东济南新旧动能转换起步区社工招聘30人备考题库附答案详解(研优卷)
- 赣州市总工会2025年度公开招聘工会社会工作者备考题库【14人】附答案详解(基础题)
- 基于两电平VSC换流器平均值模型的建立与仿真
- 银行保安业务知识培训课件
- 新疆图木舒克市2025年上半年公开招聘辅警试题含答案分析
- 电梯井钢结构施工合同(2025版)
- 2025年石油工程师重点练习:油藏数值模拟
- 公墓扩建工程项目可行性研究报告-标准案例
- 俱乐部年末活动方案
- 保安服务台账资料相关表格
- 《住院患者身体约束的护理》团体标准解读课件
- 中国著名作家叶圣陶代表作《稻草人》名著知识点梳理作品解析课件
- 工业自动化项目设计合同
评论
0/150
提交评论