已阅读5页,还剩19页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Class 2 Power Units -UL 1310 (5th Edition) (Dated May 3, 2005, Last Revise Date Jan. 31, 2006) -CAN/CSA-C22.2 No. 223-M91 (2nd Edition) (Dated June 1991)Agenda(大綱) Scope (范围) Class 2 Definition (Class 2定义) Key Construction Requirements (结构要求重点) Enclosure/Protective Devices/Coil Insulation/Input Connections/Output Connections /Accessibility of Live Parts/Separation of Circuits/Grounding/Spacing(外壳/保护装置/变压器绝缘/输入连结/输出连结/带电体可接触性 /线路隔离/间距) Key Performance Requirements (测试要求重点) Electrical Tests (电气测试) Mechanical Tests (机构测试) Caution Marking & Instruction (警告标示及使用说明) Relative SPS Standard Instruction (相关标准简介)Scope (範圍)Indoor and outdoor use Class 2 power supplies and battery chargers for use on alternating current branch circuits with a maximum potential of 150 V to ground.连接于对地最大电压150 V的交流电源上之室内及户外用 Class 2电源适配器及充电器 Portable direct plug-in units provided with 15 A blade configurations for use on nominal 120 or 240 V branch circuits Cord- and plug-connected units provided with a 15 A or 20 A attachment plug configuration(构造) Units permanently connected to the input supplyInput power does not exceed 660 W under any possible condition of output loading (最大输入功率不超过 660W)Class 2 Definition (Class 2定义)Class 2 Voltage Limitation(Class 2电压限制 ) Voltage Type Indoor-use units Outdoor-use units Sinusoidal, ac 30 V, rms 30 V, rms (UL) Non-sinusoidal, ac 42.4 V, peak 42.4V, peak (UL)Pure dc 60 V (UL) 60 V (UL) Non-sinusoidal ac or dc 42.4 V (CUL) 42.4 V (CUL) Note: For AC Systems - If the product exceeds the 15 V rms and 21.2 V peak; and is not greater 30 V rms and 42.4 V peak; For DC Systems - If the product exceeds the 30 V for continuous dc The product shall be marked as below:US “Class 2 not wet,” “Class 3 wet”Canada “Class 2 not wet,” “Class 1 wet”Max. O/P current for inherently limited units (先天限制的) (30.1)Circuit voltage (Vmax) a,b ac or dc VoltsMax. nameplate ratingsMax. o/p current(I max)c, amperesV-AAmperes0 20Over 20 to 30Over 30 to 60, dc only5.0 X V max1001005.0100/Vmax100/Vmax8.08.0150/Vmaxa V max : Maximum output voltage regardless of load with rated input voltage applied.b Voltage ranges shown are for sinusoidal alternating current and continuous direct current. For nonsinusoidal alternating current, maximum voltage shall not be greater than 42.4 volts peak. For direct current interrupted at a rate of 10 200 hertz, maximum voltage shall not be greater than 24.8 volts.c I max is maximum output current regardless of load.The maximum output volt-amperes shall not be more than 100 volt-amperes (最大输出不得超过 100VA)Max. O/P current and VA for not inherently limited units (非先天限制的) (Cl30.2)Circuit voltage (Vmax) a,b ac or dc VoltsMax. nameplate ratingsMax. o/p current(I max)c, amperesMax. o/p VA(VA max)dMax. overcurrent protection rating, AV-AAmperes0 20Over 20 to 30Over 30 to 60, dc only5.0 X Vmax1001005.0100/Vmax100/Vmax1000/Vmax1000/Vmax1000/Vmax250e2502505.0100/Vmax100/Vmaxa V max is the maximum output voltage regardless of load with rated input voltage applied.b Voltage ranges shown are for sinusoidal alternating current and continuous direct current. For nonsinusoidal alternating current, maximum voltage shall be greater than 42.4 volts peak. For direct current interrupted at a rate of 10 200 hertz, maximum voltage shall not be greater than 24.8 volts.c I max is maximum ampere output regardless of load after operation as specified in 30.2.1.d VA max is maximum volt-ampere output regardless of load after operation as specified in 30.2.1.e Maximum volt-amperes is 350 if maximum circuit voltage is 15 or less.Construction (結構)Mechanical Assembly-Direct Plug-In (机构组立-插墙式) (Cl7.11)Mechanical Assembly-Direct Plug-In (机构组立-插墙式)(7.16)Determination of perimeter of units with rounded edgesA = 5.1 mm for UL (Marking for Mounting(固定件)Tab)A = 8.0 mm for CUL (No Mounting Tab)If a mounting tab be provided, the following conditions shall be met:a) Use on a or 15-ampere, 125- 250-volt receptacle (NEMA 1-15R or 5-15R or 6-15 R);b) A screw No. 6 mounting screw (3.5 mm major diameter, 32 threads/inch) is provided and constructed to secure to a duplex (双方的) receptacle that has a center screw;c) For a unit without a grounding pin, the mounting tab is constructed to be mounted to both grounding and non-grounding receptacles; andd) Marked “CAUTION” and the following or the equivalent:1) “Risk of Electric Shock Disconnect power to the receptacle before installing or removing the unit. When removing receptacle cover screw, cover may fall across plug pins or receptacle may become displaced;”2) “Use only with duplex receptacle having center screw;” and3) “Secure unit in place by receptacle cover screw”Metal Enclosure (金属外壳 )Indoor use: A sheet metal thickness not less than that in Table 8.1. The thickness of sheet metal other than steel or aluminum shall not be less that than in Table 8.1 for uncoated steel (8.4) Iron and steel parts shall be protected against corrosion (抗蚀)by galvanizing (镀锌), plating (电镀), enameling (上釉), or other equivalent means if the corrosion (侵蚀)of such unprotected parts results in a risk of fire, electric shock, or injury to persons (9.1)Outdoor use: A type 3R, 3S, or 4X enclosure evaluated with UL 50 (CCN: CYIV or BGUZ), is not required to be subjected to the Rain Test (56.1) A metallic enclosure shall be protected against corrosion (57.5) Copper, bronze(青铜), and brass(黄铜) containing no less than 80 percent copper, or stainless steel may be used without additional protection against corrosion (57.6)Enclosure (塑料外壳)Indoor use: UL: Flammability (燃烧等级 ):Min. V-2 (UL 94) CUL: Flammability: Min. V-1 (UL 94) Resistance to arcing properties: UL 746C Moisture absorptive propertiesOutdoor use: A type 3R, 3S, or 4X enclosure evaluated with UL 50 (CCN: CYIV or BGUZ), is not required to be subjected to the Rain Test An enclosure of a unit shall be constructed to reduce the risk of electric shock due to weather exposure and shall prevent live parts, electrical components, or wiring (not identified (鉴别)for use while in contact with water) from becoming wetProtective Devices (保护装置) The protective device may be located in either the primary or secondary circuit (可在初级或次级线路 ) Type of protective device: Thermostat, Thermal Cutoff, Positive Temperature Coeffecient (PTC) Resistor, Negative Temperature Coeffecient (NTC) Resistor, Fuse, Eutectic Material (双合金材料 ) An protective device shall not open when delivering its rated output (正常额定输出时, 保护装置不可做动) A protective device for a not inherently limiting Class 2 power unit shall not be of the automatic reclosing type(自动恢复式) and shall be rated with Table 30.2 and provided in secondary circuitCoil Insulation (变压器线圈绝缘) Any type or thickness of insulation may be used if the coil withstands the induced potential test (13.2.8.b) Tape used as insulation in lieu of (代替)spacing shall provide a continuous 1/32 inch (0.8 mm) minimum wide bent up edge against the bobbin flanges (使用胶带当绝缘以抵押间距要求则须提供至少 0.8 mm宽的反折) (13.2.3)A flanged, bobbin-wound transformer shall be subjected to the output loading test continued for 15 days if the transformer has: The primary winding wound over the secondary winding or the secondary winding wound over the primary winding; and The primary winding insulated from the secondary winding by a layer of insulating material other than coil form/bobbin The test is not required to be applied for 15 days if the following requirements are met: Multiple layered winding wire UL 746A, UL 746B, UL 746C Meet spacing requirement Table 24.1, Table 24.2 Alternate spacing UL 840 Triple insulated wiring Subject 2353 (OBJT2)Input Connection (输入连结)Multiple Voltage Rated Power Unit (多输入电压电源适配器)Definition (定义): A power unit with a rated voltage range (such as 100 240 volts) or more than one discrete voltage rating (such as 120/240 volts)Intended for Use By Travellers (旅行者用电源适配器)Definition (定义): (14.1.4) A multiple voltage rated direct plug-in power unit with a 125 V, 15 A (parallel) input blade configuration, or a multiple voltage rated cord-connected power unit with a non-detachable power supply cord terminating in a 125 V, 15 A (parallel) blade plug Requirements for Intended for Use By Travellers (旅行者用电源适配器的要求): (14.1.4)a) The blade assembly shall be a 125 volt, 15 amp configuration(构造); b) The power unit shall employ a user adjustable (可调整的)voltage selector and comply with Switch Position Test, or be capable of operating at different voltages without user adjustment;c) The input voltage rating shall include nominal 120 volt;d) The power unit shall be marked as specified in 51.8; ande) The power unit shall be provided with instructions as specified in 54.4 A multiple voltage rated power unit intended for use by travelers shall be marked as follows with the following or equivalent: (51.8)a) See instruction manual for use in countries other than the U.S.A. orb) “See instructions for input voltage conversion.” orc) “See instructions if the input plug does not fit the power outlet” Instructions shall include (a) - (c) or the equivalent, as appropriate. The items shall be preceded by IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS and DANGER - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, CAREFULLY FOLLOW THESE INSTRUCTIONS in letters of 1/8 inch (3.18 mm) high or in a readily visible contrasting text (54.4)a) Be sure voltage selector is in correct voltage position before plugging in. The instructions shall also specify the procedures to follow for changing the voltage selectorb) For use in the U.S.A., the voltage selector switch must be placed in the 120 volt position. For use in countries other than the U.S.A., the voltage selector may need to be placed in other than the 120 volt position. Confirm the voltage available at each country location before using the productc) For connection to a supply not in the U.S.A., use an attachment plug adapter of the proper configuration for the power outlet, if needed. or “If the shape of the plug does not fit the power outlet, use an attachment plug adaptor of the proper configuration for the power outletDirect Plug-in Units (插墙式)Indoor use: Blade assembly meet UL 1681, UL 1310 par. 7.16 and 7.17 A direct plug-in unit employs a manually operated line connected single-pole switch or a fuse with an accessible contact, it shall employ a polarized- or grounding-type blade assembly (如有手动电压选择开关或可接触式保险丝, 则需是极性或有接地的blade) (14.1) A direct plug-in unit employs folding or retractable blades for the input connectors, it shall comply with Direct Plug-in Security of Input Contacts Test (Blade Endurance Test for 6000 cycles) (44.2)Outdoor use: Brass containing of blades no less than 80 percent copper (57.6)Cord Connected Units (桌上型 )Indoor use: Table 14.1 and cord external length shall not be less than 6 feet (1.8 m) and not smaller than No. 18 AWG (14.2.1 & 52.12)DC input units: Shall be provided with a vehicle battery adapter in compliance with UL 2089 (14.3.1)For UL: A power unit marked adjacent to the appliance coupler to inform the user to see the instruction manual for proper (适当的) selection of the power supply cord and the instructions shall specify selection of a cord complying with the requirements in 14.2.1 is not required to be provided with the detachable power supply cord. (51.7)For CUL: The detachable power supply cord shall not be optional.(分离式电线一定要随货出)Outdoor use: Shall be at least as serviceable as junior(低级的) hard service cord type SJW, SJOW, SJTW, SJTOW, SW, SOW, STW, or STOW Shall employ a 3-conductor grounding type supply cord Exception: A power unit that does not have parts required to be grounded is not required to employ a grounding type supply cord Shall be a non-detachable power supply cord with an attachment plugOutput Connection (输出连结 ) A unit shall be provided with an output cord, terminals, insulated leads, or output connectors. A battery charger with backfeed protection shall be provided with an output cord terminating in a connector, or a connector attached to or integral (完整的) with the enclosure (15.1.1)(输出线, 端子, 绝缘导线或输出接头皆可当输出连结;充电器的输出线需带有接头或是接头附在外壳上) For CUL, permanently attached cord terminating in a connector shall be providedIndoor use:Output Wiring: Shall be stranded conductors(绞线) having insulation not less than 0.013 inch (0.33 mm) thick, and permanently attached to the output circuit. The wiring shall extend at least 6 feet (1.8 m) outside the unit (15.2.1) For a cord-connected unit (桌上型 ) with a minimum 6 feet (1.8 m) power-supply cord, the output flexible cord (permanently attached to the power unit or provided in the form of a separate cord set) shall be of any desirable length. The maximum combined length of the input and output cords shall not exceed 20 feet (6.1 m) (15.2.2)Outdoor use:Output Wiring: Shall be suitable for outdoor use, “W” rated, and sunlight (UV) resistant (抗紫外线) as applicable to outdoor cords (60.1) For CUL, shall be of the type in Table 11 of the Canadian Electrical Code, Part I, and shall at least of the type SPT-2, PXWT or CXWT and suitable for wet locationsOutput Wiring:Strain Relief Bushing (套管)be suitable for outdoor use and sunlight (UV) resistant (抗紫外线) (QMFZ2) with f2 code or (QMTT2)Output terminals: A terminal plate shall be not less than 0.030 inch (0.76 mm) thick, and shall provide not less than two full threads in the metal for the binding screw (15.3.1) (安上接线螺丝或螺栓的接线板应由黄铜或其它非铁金属,或镀钢制成,厚度不少于0.030 吋 (0.76 毫米),和在金属内应提供不少于两个完全的螺纹给接线螺丝使用。 A wire-binding screw shall not be smaller than No. 6 (3.5 mm diameter) and shall not have more than 32 threads per inch (25.4 mm) (15.3.2) A multi-output unit employing output terminals the output of which exceeds the current limit (inherently limited) with outputs interconnected shall be marked with “CAUTION” and “Risk of Fire. Use only Type SPT-2 or heavier cord, minimum 18 AWG copper” (15.3.4 and 52.12)Output connectors: A unit with multiple outputs where interconnection exceeds Class 2 levels shall be provided with a polarized connector (15.4.1) Output connectors mounted on the enclosure and intended for direct connection of accessories shall be polarized if the output is direct-current or if multiple outputs are provided (15.4.2) Connectors normally used with coaxial cable shall not be used (15.4.5) USB can be as output connector by output shall not be more than 5 V dc, 500 mA Clips (夹子, 回形针) shall not be used as output connectorA battery charger shall be provided with a means to inhibit backfeed of current (反聩电流 ) which results in a risk of fire or electric shock. The means of prevention shall protect each output and shall consist of any of the following: (15.4.3)a) A fuse, calibrated located in the output connector and rated to correspond with the maximum overcurrent protection ratingb) A diode or fixed impedance located in the output connector where it will limit backfeed currentc) An overcurrent protector equivalent to (a) located in the output connectord) An output cord equivalent to that specified in Table 14.1 with respect to insulating material and thicknessOutput connectors: Outdoor use Material of connector shall be QMFZ2 with f2 code (Ultraviolet Light Resistant)(抗紫外线) or QMTT2 suitable for outdoor use (Ultraviolet Light Resistant) (抗紫外线) Accessibility of Live Parts (带电体可接触性)Indoor use:Live parts other than exposed (暴露的) wiring terminals: (16.2) (通常指内部电路 )The test pin and articulate probe shall not contact: (16.2.1)a) A primary circuit; orb) Any live part with a voltage greater than the following with respect to ground or any other live part simultaneously accessible to the test pin or articulate probe 1) 42.4 V peak for sinusoidal or nonsinusoidal AC 2) 60 V for continuous DCThe test pin and articulate probe are to be applied with a force not exceeding 1 pound (4.4 N) to determine whether the live parts are accessible (16.2.3)Outdoor use:The test pin and articulate probe shall not contact: (62.2)A primary circuit; orb) Any live part with a voltage greater than the following with respect to ground or any other live part simultaneously accessible to the test pin or articulate probe 1) 15 V for sinusoidal AC a) and 21.2 V peak for nonsinusoidal AC 2) 30 V for continuous DCExposed wiring terminals: (16.3.2)Indoor use:The accessibility probe, shall not contact an exposed wiring terminal with a voltage greater (巨)大的than the following with respect to ground or any other live part simultaneously accessible to the probe a) 42.4 V peak for sinusoidal or nonsinusoidal AC b) 42.4 V for continuous DCThe accessibility probe is to be applied with a force not exceeding 5.62 pounds (25 N) to determine whether the exposed wiring terminals are accessible (16.3.3)Outdoor use: The accessibility probe, shall not contact an exposed wiring terminal with a voltage greater than the following with respect to ground or any other live part simultaneously accessible to the probe (62.2) a) 15 V for sinusoidal AC and 21.2 V peak for nonsinusoidal AC b) 30 V for continuous DCSeparation of Circuits (线路隔离) Unless provided with insulation rated for the highest voltage involved (有关的), insulated conductors of different circuits i
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2026贵州乌江石林旅游发展有限公司招聘2人笔试备考试题及答案详解
- 2026江铜国际贸易有限公司招聘4人笔试备考试题及答案详解
- 雅安市市场监督管理局2026年面向社会公开招聘特种设备检验编外聘用人员笔试备考题库及答案详解
- 2025年星展银行校园招聘笔试考试试题及答案详解
- 2026云南云核地质环境测试有限公司招聘7人笔试备考题库及答案详解
- 2025年农业发展银行(青海省分行)人员招聘笔试考试试题及答案详解
- 2026重庆招商局交通科技有限公司招聘15人笔试备考题库及答案详解
- 2026四川凉山州布拖县总工会招聘工会社会工作者1名笔试模拟试题及答案详解
- 泸县教育和体育局2026年公开考调下属事业单位教师(99人)笔试参考题库及答案详解
- 2026年兰州银行校园招聘考试备考试题及答案详解
- 城轨安全用电-触电急救
- JJG539-2016数字指示秤检定记录格式
- 慢性肾脏病健康宣教
- 氩气安全技术说明书MSDS
- 银行保安服务投标方案(完整技术标)
- 拒绝文身主题班会课件
- 北京版八年级数学下册全册课件【完整版】
- 汽车行走的艺术学习通课后章节答案期末考试题库2023年
- 常微分方程一阶微分方程的初等解法公开课一等奖市赛课获奖课件
- 上海市临检中心 临床微生物学检验新技术及质量控制学习班课件 微生物检验新技术、新趋势
- 颈椎病的正骨推拿治疗
评论
0/150
提交评论