房产销售中心装饰CAD施工图及含效果图.rar
收藏
资源目录
压缩包内文档预览:
编号:53843276
类型:共享资源
大小:16MB
格式:RAR
上传时间:2020-03-05
上传人:活***
认证信息
机构认证
宁夏凯米世纪网络科技有限公司
宁夏
统一社会信用代码/组织机构代码
91640100MA774ECW4K
IP属地:宁夏
12
积分
- 关 键 词:
-
房产
销售
中心
装饰
CAD
施工图
效果图
- 资源描述:
-
房产销售中心装饰cad施工图及含效果图.rar,房产,销售,中心,装饰,cad,施工图,效果图
- 内容简介:
-
-1-bardoninstallation instructionsvitreous china touchlessurinaltmk-4915t/k-4915t-wa. how to use these instructionsplease read these instructions carefully to familiarizeyourself with the required tools, materials, and installationsequences. follow the sections that pertain to yourparticular installation. this will help you avoid costlymistakes. in addition to proper installation, read alloperating and safety instructions.all information in these instructions is based upon thelatest product information available at the time ofpublication. kohler china reserves the right to makechanges in product characteristics, packaging, oravailability at any time without notice.these instructions contain important care, cleaning, andwarranty information -.please leave instructions for theconsumer?a.?b. notes?observe all local plumbing and building codes.urinal flushes efficiently with less than 0.8 gallon of water.stop valve has a 1/2npt inlet supply connection.fixture dimensions are nominal and conform to tolerancesby ansi standard a112.19.2m.b.?31/2npta112.19.2mc. required tools and materials?open end/adjustable wrenchessupply piping and connectorstape measurethread sealant tapebasin wrenchscrewdriverc.?/d. roughing-inturn off cold water supplies.install or relocate supply tubing and waste pipe to conform toroughing-in dimensions.for roughing-in dimension requirements.* urinal complies with ada requirement when rim is mountedno higher than 17from finished floor.see fig. #1d.1*432mm528137, 2008copyright kohler china ltd., 20081066532-t01-b22-32mm70mm610mm533mm603mm76mm*610mm2n.p.s. tap1/2 n.p.s. inletfor stop valve362mm14620mm464mm305mm838mm1029mmto floor12mm2n.p.s. tap152mmoutlet detailsnote: roughing-in dimension requirements forsupply tubing as shown.supply tubing is 22-32mm out of the wall.otherwise, stop valve can not be installed andadjusted properly.:22-32mmfig. #11installationa. mount urinalsee fig. #2caution: risk of chipping or breaking urinal.note:install hangers per roughing-in illustration.apply sealant tape to pipe threads and install female collar onwaste pipe.place washer on female collar with bevelled surface facingaway form collar.install urinal. secure urinal to female collar with screws andwashers.donot overtighten screws.do not caulk top surface of urinal. caulk may preventtank cover from seating properly.a.2:hangerscollarapply sealant tapewasherfig. #22-2-+10mm01066532-t01-bb. connect supplysee fig. #3note:note:note:apply sealant tape to pipe thread and install stop valveassembly and tighten connection.stop valve should face left side of tank whentighten.it is recommended that a temporary rubber or plastic hose isattached to the stop valve, and the water supply line shouldbe flushed clean of dirt and debris.plug seal ring into inlet hole of urinal.remove the nuts for fixing the bezel and the two clamps.while removing the nuts, avoid dropping bezel,which may break urinal.take off the protection cap of the sensor window. put thesensor window into the bezel, fix sensor window with theclamp and the nuts.tighten the nuts slightly to prevent damagesensor window (do not over tighten the nuts.)b.3:fig. #33clampnutstop valvesensor windowbezel-3-1066532-t01-bsee fig. #4note:loose the pipe clamp and adjust the position of plastic pipeand outlet pipe. do not tighten for the future adjustment. putthe g1/2 washer into the connector of the pipe assy. connectthe pipe assy with the valve assy.take off the protection cap from the connector assy.do not screw the part between the connectorassy and the valve assy. do not lose the filter assywhen taking off the protection cap.4g1/25g1/220mmsee fig. #5note:put the valve assy and the pipes into the tank of urinal. adjustthe distance of outlet pipe and plastic pipe. then make theoutlet pipe aim at the sealing washer and make the valveassy aim at the outlet of stop valve.plug the other end of outlet pipe into the sealing washer andconnect the valve assy with the stop valve.at this time, all the pipes, valve assy and stop valve shall beplaced orderly. tighten the pipe clamp and the nut.do not lose the filter assy during theinstallation. the distance between pipe clamp and theend of outlet pipe shall be more than 20mm.fig. #44fig. #55-4-plastic pipepipe clampvalve assyprotection capoutlet pipeg1/2 washerg1/2connector assy.filter assy.outlet pipepipe clamp20mmnutsealing washer1066532-t01-bsee fig. #6note:turn on stop valve. inspect pipes for leakage in not flushing.connect the connector of sensor window with the connectorof solenoid valve.remove the battery box cover and insert alkaline batteriesinto the battery box. reinstall the cover of battery box andtighten it with battery box with screws. connect the connectorof battery box with the connector of sensor window.see the section replacing batteriesdo not lose the screws when removing thecover of battery box. tighten the screws, otherwise thebatteries may be affected with damp.“”.6:fig. #66the state of distance adjustment has been last about 10minutes after power on. no flushing during this period. beforepower on, clear the unwanted objects in front of the sensorwindow to shortening the sensing distance.the sensor will begin to work normally after about 10 minutes.if flushing water volume is not enough, reset the flushing timereferring to flushing duration setting in order to changingthe flushing water volume.“”-5-1066532-t01-bscrewhooksleevenutwasherc. install tank coversee fig. #7note:caution: risk of chipping or breaking urinal.open tank cover lock package and remove contents.place tank cover upside down on a protected surface toprevent damage to tank cover finish.place hooks inside tank cover.if necessary, engage the hooks facing opposite thedirection illustrated.using a 5/8wrench, assemble and tighten nut, washer andlock nut on both sides of urinal.donot overtighten screws on urinal.put tank cover on the urinal.using supplied locking tool, install and tighten screw.check that tank cover is properly locked.c.75/8:fig. #77-6-1066532-t01-bdon t use this system after 10 minutes power on.the induction distance will be adjusted and the system willnot work during this time.10user s guideuser s guide-7-working status flushingbefore power on, clear the unwanted objects in front of thesensor window to shortening the induction distance.replacing batterieswhen the batteries are nearly exhausted, the indicator willflash every 2 seconds, the sensor stop working until newbatteries are changed.when changing the batteries, open the cover of battery boxand insert new batteries.: pay attention to the pole of batteries and donot use new and old batteries at the same time.note2clean the filter assyif the flushing volume is reduced, the filter assy must becleaned.remove the nut and take out the filter assy. clean it with abrush and reinstall.: turn off the stop valve before cleaning.notescrewscover of battery boxbatteriesbattery boxvalve assynutfilter assystop valve1066532-t01-b-8-flushing duration settingif the flushing volume is reduced, the flushing duration can beadjusted.power off until the indicator stops flashing. during the first 10minutes after power on, approach the flushing control stick tothe center of the sensor window for about 8 seconds.remove the flushing control stick after a flushing cycle.: the inducting distance will be adjusted. anyobject shall move from in front of the sensor window.note()108deodorizing flushingthe urinal will take a flush automatically when it s used 3 or 4times in 2 minutes.23-4care & cleankeep the sensor window clean. wipe with soft cloth and mildcleaner.a. do not use dust-removing powder, abrasive powderor cleaner containing oli, acid or alkaline ingredient.b. do not spray air-refresher, disinfect, or otherdeodorizing, cleaning solvent directly into thesensor window.c. keep wire away from water.d. don t attack the sensor window.notice:a.b.c.d.flushing control stick1066532-t01-bsensor specificationsensor specificationpower supplypower consumptioninduction distancedetection durationflushing modeflushing water volumedeodorization flushingstarting pressureoperation temperature2 piece of aaa sized alkalinebatteries27the batteries can be used abouttwo years (4000 times a month)(4000)automatic adjustment accordingto the ambient circumstanceabout 2 seconds or 5 seconds(automatic adjustment)double flushingaverage flushing volume is notmore than 3 l at pressure0.180.55mpaone forced flushing will beconducted if the urinal is beingused continuously for 2 minutes.0.05-0.7mpa.ambient (water) temperature of1 c-55 coo25()0.180.55mpa3l20.05-0.7mpa.1 c-55 c(1 c-55 c)oooo-9-recommended water supply pressure (dynamic pressure atinlet): 0.1-0.55mpa.(): 0.1-0.55mpa1066532-t01-btroubleshootingsymptomscorrective actionprobable causesmake sure to complete the prcedures following before asking for repair:no flushing(indicator lamp fails to work)()indicator lamp flashingbut little or no waterwhen user or object detected()water does not stopindicator lamp does not flash()battery indicator lamp flashingcontinuously and no waterafter the check above, the problem still exist, contact us through dealer.1. no batteries or batteries reversed.2. there are other objects are being detected.3. dirty sensor window.1.2.3.1. initial 10 minutes.2. stop valve is not opened.3. low water pressure.4. dirty filter.1.2.3.4.the valve is clogged.batteries are exhausted.1. check the batteries.2. remove objects or adjust the inductiondistance.3. clean the sensor window.1.2.3.1. wait 10 minutes.2. turn on the stop valve.3. increase water supply pressure.4. clean the filter or remove restrictor.1.102.3.4.clean fliter and cause unit to flush severaltimes. if filter clogs again, turn off stopvalve, flush to clean off water supply line.replace the batteries.1. urinal is designed for use with potable water. avoid waterthat includes a lot of contaminants or with acid/alkali waterand impure water.2. if you live in a hard water area, make certain that the holedin the toilet rim are kept clean to ensure proper bowlflushing. toilet bowl cleaners should be used at least oncea week. use a long-handled brush to clean the rim holes,and to clean as far into the trap as possible to preventmineral deposits from forming.3. most toilet bowl cleaners are not harmful to the surface ofthe urinal. please follow the bowl cleaner manufacturesinstructions carefully.4. do not use abrasive cleaners for china surface.5. do not directly flush the wire connector of sensor withwater.6. do not make sensor window near strong ultraviolet andelectromagnetism.7. keep the sensor window clean. do not attack the sensor.the sensor cover can be cleaned by the soft rag (withneutral liquid detergent). do not use the eradicator,abrasive powder or the oil, acid or alkali liquid detergent.do not sprit the air freshener, disinfectant or the otherkinds of odious smell remove, clean organic liquid to thesensor directly.1.2.3.4.5.6.7.consumer responsibilities-10-1066532-t01-bbardonservice parts pagek-4915t/k-4915t-wvitreous china touchlessurinaltm* color code must be specified when ordering.-11-82372-*coverscrew m3x81045457pressing board1045456o ring 91o 1045455cap1056081solenoid valve assy.screw m2.561045460springconnector1066284filter assy.washerrestrictorstop valveconnector assy.gasket 11gasket 22connectorg1/2 washerg1/2valve bodyear clip1066290pipe clamp1066289plastic pipe1066279valve sub assy.1045458valve cover1045459 o ring 51o1045461diaphragms assy.outlet pipe1056053battery box74250clamp74250clamp21251washer76636nut75412stud1066275-fktouchless urinal sensorconnector1066277sensor window32935nut49932washer73975tube51588washer52046hanger accessory pack53405collar53407screw53410washer53407screw51543washerwrenchsleevenuthookwasherscrew1043250tank cover locks73203bezel85061beehive strainerassy.1020016flushing control sticksealingwasherconnector1066532-t01-b产品规格:产品尺寸图:( 单位: 毫米)k-4915t巴尔顿节水型自动感应小便器bardonk-4915t22-3270610533603766104643058381029+100型号来水口高度( 小便器)宽度墙面至开口距离材料冲水系统平均用水量包括产品内装电池的电子感应冲水阀,挂钩,进出水配件及蜂窝式筛网k-4915t-w464 mm1升后接来水式838 mm釉面陶瓷362 mm自动感应直冲式before you beginbefore you beginroughing-in dimensionsroughing-in dimensionsnotes?use these instructions for above-counter installation.please follow the instructions that apply to yourinstallation.you can choose between a wall-mount or countertopfaucet installation, depending upon the setting and stylingyou desire. we recommended a wall-mount faucet.prior to installation, unpack the new lavatory and carefullyinspect it for damage. return the lavatory to its protectivecarton until you are ready to install it.all information in these instructions is based upon thelatest product information available at the time ofpublication. kohler china reserves the right to makechanges in product characteristics, packaging, oravailability at any time without notice.these instructions contain import care, cleaning, andwarranty information please leave these instructions forthe consumer.?kohler lavatory is made according to american nationalstandard that it can match the american lavatory fittings.any other lavatory fittings may not fit for kohler lavatory.?-1-roughing-in notesfixture dimensions are nominal and conform to tolerancesin asme standard a112.19.2m.(astmea)112.19.2m(t) pop-up drain 229mm.(t)229mm(s) 356mm (based on 305mm riser which may requingcutting).(s) 356mm305mm* spout must be 127mm long (min.) for adequate clear-ance into lavatory when installed with centerline as shown.*127mm()* spout must be tall enough to clear 76mm rim height andprovide a 25mm air gap per asme a112.1.2*76mmasme a112.1.225mmfig. #11conical bell vesselinstallation instructionsabove-the-counter vitreous china lavatoryk-2200t-g(s)(t)3/8 hot102mm102mm3/8 cold1-1/4 outlet*76mm162mm254mm413mmof fitting*clk-2200t-g1007250-t01-b528137?, 2007copyright kohler china ltd., 2007tools and materials required(not supplied)?sealanttemplate (supplied)safety glassespencilscissorstape measurehole sawkeyhole saw or saber sawdill (1/2 dia. drill bit, or larger)screwdriver()?()(13mm)-2-position the template on thecountertop.be sure toprovide sufficient spout overhang intothe lavatory basin. see the roughing-innotes for minimum spout lengthinformation.pay specialattention to the spout and handle fitclearance when locating the faucet, asnoted below. use the template tolocate the faucet spout hole centerlineon the countertop. this centerline isrecommended to provide adequateclearance between the edge of thelavatory and the spout.check for adequate clearancebetween the backsplash or wall faucetspout and handles, and lavatory. werecommend clearance of at least25mm between:the installed lavatory and thefaucet spoutthe installed lavatory and the endof the faucet handles, andthe faucet spout and handles andthe backsplash or wall.refer to the faucet installationinstructions for required clearance, andmark the preferred faucet holelocations using a soft lead pencil.trace the template on the countertopusing a soft lead pencil.for wall-mount faucets:for countertop faucets:?note: in china installation will nothave separate backsplash. the backwall is the backsplash.countertop installationscountertop installations25mm?25mm min.clearance25mmspoutcenterlinebacksplashcut-out lineoutside edgeof lavatoryfig. #221007250-t01-bfor tile, wood, or other porousmaterials, apply waterproof sealantaround the cutout area of thecountertop surface. follow allmanufacturers instructions andwarnings. allow the sealant to drybefore proceeding.use a 50/50 mixture of isopropylalcohol and water to clean thecountertop surface around the cutoutarea. wipe dry with a clean cloth.: install the adhesive sealantwhen the temperature is at least 10 c.the preferred temperature range toapply the adhesive sealant is 21 c to38 c.loosely apply the adhesive sealantaround the entire countertop cutout soit is alongside the cutout hole. adjustthe placement of the sealant beforeremoving the backing material. cut offany excess seal material. carefullyremove the adhesive seal backingmaterial.noteooo50/50102138adhesivesealantfig.#44drill the faucet holes.install the faucet to the countertop according to themanufacturers instructions.install the drain to the lavatory according to the installationinstructions included with the drain. apply a sufficient amountof clear silicone sealant when you install the drain.fig.#33kohlercut out the opening by carefullyfollowing the pencil line.large lavatories are very heavy.get h
- 温馨提示:
1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
2: 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
3.本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

人人文库网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。