




已阅读5页,还剩5页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
LTE R12 UE category和category DL/UL区别规范1、ue-CategoryThe field ue-Category defines a combined uplink and downlink capability. The parameters set by the UE Category are defined in subclause 4.2. Tables 4.1-1 and 4.1-2 define the downlink and, respectively, uplink physical layer parameter values for each UE Category. A UE indicating category 6 or 7 shall also indicate category 4. A UE indicating category 8 shall also indicate category 5. A UE indicating category 9 shall also indicate category 6 and 4. A UE indicating category 10 shall also indicate category 7 and 4. A UE indicating category 11 shall also indicate category 9, 6 and 4. A UE indicating category 12 shall also indicate category 10, 7 and 4. Table 4.1-4 defines the minimum capability for the maximum number of bits of a MCH transport block received within a TTI for an MBMS capable UE.Table 4.1-1: Downlink physical layer parameter values set by the field ue-CategoryUE CategoryMaximum number of DL-SCH transport block bits received within a TTI (Note 1)Maximum number of bits of a DL-SCH transport block received within a TTITotal number of soft channel bitsMaximum number of supported layers for spatial multiplexing in DLCategory 110296102962503681Category 2510245102412372482Category 31020487537612372482Category 41507527537618270722Category 529955214977636672004Category 6301504149776 (4 layers, 64QAM)75376 (2 layers, 64QAM)36541442 or 4Category 7301504149776 (4 layers, 64QAM)75376 (2 layers, 64QAM)36541442 or 4Category 82998560299856359827208Category 9452256149776 (4 layers, 64QAM)75376 (2 layers, 64QAM)54812162 or 4Category 10452256149776 (4 layers, 64QAM)75376 (2 layers, 64QAM)54812162 or 4Category 11603008149776 (4 layers, 64QAM)195816 (4 layers, 256QAM)75376 (2 layers, 64QAM)97896 (2 layers, 256QAM)73082882 or 4Category 12603008149776 (4 layers, 64QAM)195816 (4 layers, 256QAM)75376 (2 layers, 64QAM)97896 (2 layers, 256QAM)73082882 or 4NOTE 1:In carrier aggregation operation, the DL-SCH processing capability can be shared by the UE with that of MCH received from a serving cell. If the total eNB scheduling for DL-SCH and an MCH in one serving cell at a given TTI is larger than the defined processing capability, the prioritization between DL-SCH and MCH is left up to UE implementation.Table 4.1-2: Uplink physical layer parameter values set by the field ue-CategoryUE CategoryMaximum number of UL-SCH transport block bits transmitted within a TTIMaximum number of bits of an UL-SCH transport block transmitted within a TTISupport for 64QAM in ULCategory 151605160NoCategory 22545625456NoCategory 35102451024NoCategory 45102451024NoCategory 57537675376YesCategory 65102451024NoCategory 710204851024NoCategory 81497760149776YesCategory 95102451024NoCategory 1010204851024NoCategory 115102451024NoCategory 1210204851024NoTable 4.1-3: Total layer 2 buffer sizes set by the field ue-CategoryUE CategoryTotal layer 2 buffer size bytesWith support for split bearersCategory 1150 000230 000Category 2700 0001 100 000Category 31 400 0002 300 000Category 41 900 0003 100 000Category 53 500 0005 900 000Category 63 300 0005 800 000Category 73 800 0006 200 000Category 842 200 00061 600 000Category 94 800 0007 200 000Category 105 200 0007 600 000Category 116 200 00011 000 000Category 126 700 00011 500 000Table 4.1-4: Maximum number of bits of a MCH transport block received within a TTI set by the fieldue-Category for an MBMS capable UE UE CategoryMaximum number of bits of a MCH transport block received within a TTICategory 110296Category 251024Category 375376Category 475376Category 575376Category 675376Category 775376Category 875376Category 975376Category 1075376Category 1175376 (64QAM)97896 (256QAM)Category 1275376 (64QAM)97896 (256QAM)Table 4.1-5: Half-duplex FDD operation type set by the field ue-Category for a half-duplex FDD capable UEUE CategoryHalf-duplex FDD operation typeCategory 1Type ACategory 2Type ACategory 3Type ACategory 4Type ACategory 5Type ACategory 6Type ACategory 7Type ACategory 8Type ACategory 9Type ACategory 10Type ACategory 11Type ACategory 12Type A2ue-CategoryDL and ue-CategoryULThe fields ue-CategoryDL and ue-CategoryUL define downlink/uplink capability respectively. The parameters set by the UE DL/UL Categories are defined in subclause 4.2. Tables 4.1A-1 and 4.1A-2 define the downlink and, respectively, uplink physical layer parameter values for each UE DL/UL Category Table 4.1A-4 defines the minimum capability for the maximum number of bits of a MCH transport block received within a TTI for an MBMS capable UE. Table 4.1A-6 defines the only combinations for UE UL and DL Categories that are allowed to be signalled with ue-CategoryDL and ue-CategoryUL. Table 4.1A-6 also defines which UE Categories a UE shall indicate in addition to the combinations for UE UL and DL Categories.Table 4.1A-1: Downlink physical layer parameter values set by the field ue-CategoryDLUE DL CategoryMaximum number of DL-SCH transport block bits received within a TTI (Note 1)Maximum number of bits of a DL-SCH transport block received within a TTITotal number of soft channel bitsMaximum number of supported layers for spatial multiplexing in DLDL Category 0 (Note 2)10001000253441DL Category 6301504149776 (4 layers, 64QAM)75376 (2 layers, 64QAM)36541442 or 4DL Category 7301504149776 (4 layers, 64QAM)75376 (2 layers, 64QAM)36541442 or 4DL Category 9452256149776 (4 layers, 64QAM)75376 (2 layers, 64QAM)54812162 or 4DL Category 10452256149776 (4 layers, 64QAM)75376 (2 layers, 64QAM)54812162 or 4DL Category 11603008149776 (4 layers, 64QAM)195816 (4 layers, 256QAM)75376 (2 layers, 64QAM)97896 (2 layers, 256QAM)73082882 or 4DL Category 12603008149776 (4 layers, 64QAM)195816 (4 layers, 256QAM)75376 (2 layers, 64QAM)97896 (2 layers, 256QAM)73082882 or 4DL Category 13391632195816 (4 layers, 256QAM)97896 (2 layers, 256QAM)36541442 or 4DL Category 143916560391656 (8 layers, 256QAM)474316808DL Category 15749856-798800 (Note 3)149776 (4 layers, 64QAM)195816 (4 layers, 256QAM)75376 (2 layers, 64QAM)97896 (2 layers, 256QAM)97443842 or 4DL Category 16978960 -1051360 (Note 3)149776 (4 layers, 64QAM)195816 (4 layers, 256QAM)75376 (2 layers, 64QAM)97896 (2 layers, 256QAM)127895042 or 4NOTE 1:In carrier aggregation operation, the DL-SCH processing capability can be shared by the UE with that of MCH received from a serving cell. If the total eNB scheduling for DL-SCH and an MCH in one serving cell at a given TTI is larger than the defined processing capability, the prioritization between DL-SCH and MCH is left up to UE implementation.NOTE 2:Within one TTI, a UE indicating category 0 shall be able to receive up to 1000 bits for a transport block associated with C-RNTI/Semi-Persistent Scheduling C-RNTI/P-RNTI/SI-RNTI/RA-RNTI and up to 2216 bits for another transport block associated with P-RNTI/SI-RNTI/RA-RNTI.NOTE 3: The UE indicating category x shall reach the value within the defined range indicated by “Maximum number of DL-SCH transport block bits received within a TTI” of category x. The UE shall determine the required value within the defined range indicated by “Maximum number of DL-SCH transport block bits received within a TTI” of the corresponding category, based on its capabilities (i.e. CA band combination, MIMO, Modulation scheme).Table 4.1A-2: Uplink physical layer parameter values set by the field ue-CategoryULUE UL CategoryMaximum number of UL-SCH transport block bits transmitted within a TTIMaximum number of bits of an UL-SCH transport block transmitted within a TTISupport for 64QAM in ULUL Category 010001000NoUL Category 35102451024NoUL Category 57537675376YesUL Category 710204851024NoUL Category 81497760149776YesUL Category 1315075275376YesTable 4.1A-3: Total layer 2 buffer sizes set by the fields ue-CategoryDL and ue-CategoryULUE DL CategoryUE UL CategoryTotal layer 2 buffer size bytesWith support for split bearersDL Category 0UL Category 020 000N/ADL Category 6UL Category 53 500 0006 000 000DL Category 7UL Category 134 200 0006 700 000DL Category 9UL Category 55 000 0007 400 000DL Category 10UL Category 135 700 0008 100 000DL Category 11UL Category 56 400 00011 300 000DL Category 12UL Category 137 100 00012 000 000DL Category 13UL Category 34 200 0007 300 000DL Category 13UL Category 54 400 0007 600 000DL Category 13UL Category 74 700 0007 800 000DL Category 13UL Category 135 100 0008 300 000DL Category 14UL Category 850 800 00076 200 000DL Category 15UL Category 38 000 00013 000 000DL Category 15UL Category 58 200 00013 400 000DL Category 15UL Category 78 500 00013 600 000DL Category 15UL Category 138 900 00014 100 000DL Category 16UL Category 310 000 00017 000 000DL Category 16UL Category 510 600 00017 400 000DL Category 16UL Category 710 800 00017 600 000DL Category 16UL Category 1311 000 00018 100 000Table 4.1A-4: Maximum number of bits of a MCH transport block received within a TTI set by the field ue-CategoryDL for an MBMS capable UE UE DL CategoryMaximum number of bits of a MCH transport block received within a TTIDL Category 04584DL Category 675376DL Category 775376DL Category 975376DL Category 1075376DL Category 1175376 (64QAM)97896 (256QAM)DL Category 1275376 (64QAM)97896 (256QAM)DL Category 1375376 (64QAM)97896 (256QAM)DL Category 1475376 (64QAM)97896 (256QAM)DL Category 1575376 (64QAM)97896 (256QAM)DL Category 1675376 (64QAM)97896 (256QAM)Table 4.1A-5: Half-duplex FDD operation type set by the field ue-CategoryDL for a half-duplex FDD capable UEUE DL CategoryHalf-duplex FDD operation typeDL Category 0Type BDL Category 6Type ADL Category 7Type ADL Category 9Type ADL Category 10Type ADL Category 11Type ADL Category 12Type ADL Category 13Type ADL Category 14Type ADL Category 15Type ADL Category 16Type ATable 4.1A-6: supported DL/UL Categories combinations set by the fields ue-CategoryDL and ue-
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 高三电场复习课件
- 高一物理课件功率
- 高一政治课件阅读
- 高一化学氯气制备课件
- 高档住宅小区专业保洁与安保综合管理合同
- 专业婚内出轨离婚协议书定制服务及子女抚养方案
- 离婚协议书起草与财产分割协议执行监督
- 离婚后子女抚养与财产分割详细协议书
- 国际商事合同通则在跨境科研合作合同中的条款解析
- 家庭教育指导师咨询服务合同
- 《套餐销售技巧培训》课件
- 第一单元 分数乘法(单元测试)(含答案)-2024-2025学年六年级上册人教版数学
- 次氯酸钠培训
- 《射频通信全链路系统设计》 课件 第5、6章 射频通信发射机设计、射频通信时钟系统设计
- 幼儿园孩子受伤赔偿协议书范文
- DBJ46-070-2024 海南省民用建筑外门窗工程技术标准
- 合肥市肥东县大学生乡村医生专项计划招聘考试真题
- 集合间的基本关系课件
- 就业困难人员认定申请表
- 林地恢复协议书(2篇)
- 2024年哈尔滨卫生系统考试真题
评论
0/150
提交评论