




已阅读5页,还剩11页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Directorypreface. 2safe note . 3一.function and feature. 4 1.1 function. 4 1.2 feature. 4二、instruction. 5 2.1 design basis. 5 2.2. characteristic . 5 2.3 technical index. 5 2.4 LEDindicated . 5 2.5 The front ,bottom of controller . 6 2.6 wire connection instruction. 6三、design requirement. 6 3.1safety level . 6 3.2 security. 7四、installation . 74.1 install mode. 74.2 install angle. 94.3 terminal rod/insulator install. 94.4 middle rod/insulator install.104.5middle pull rod/insulator install.104.6 tensioner install.104.7lightning-arrester .104.8alloy wire connection.114.9grounding.114.10 ground wiring.11五、controller install &connection.115.1 controller install.11 5.2 controller and fence connection.12六、debug and alarm test.126.1 electrify check.126.2alarm test. .12七、install rule & security note.158.1 install rule.158.2 safety note and some removing methods .16Preface shanghai Yi Section Company is specialized in manufacturing electric security fence with its own R&D department factory located in Shenzhen. Yi Section company persistently follows the principledo everything with whole hearted, through superior quality and zealous service, Yi Section tries every efforts to respond the users that gives us long-term support and trust. Pulse electric fence energizer and perimeter accessory that Yi Section products and develops conforming to the requirements of GB/T7946-2008 pulse electric fence installation and safe operationand meet CEI-61011 international electric fence standard. The patent water proof casing design, professional output method, advanced difference voltage output technology, unique LCD display function, make the products as the leader in the industry. The products sell to Unite States, Europe, Australia, Africa, and Asian country , Yi Section will be the base of international production and service. The products are widely used in ware house, industry areas, power station, private house, villa, school, car parks, plant areas, airpot, prison, military base.etc.Security note:Unless high/low voltage output disarmed of electric fence, dont touch the conductor part of the system. Dont install electric fence during the thunder, dont install controller in moist place.Before install and use the product, do the safe educational technology training work.During the installation, in order to use normally in future, follow the instructions to make sure the grounding of products. Refer to “4.9 item” When the product is electrified , the inside of controller is 220v 50Hz AC current, 5-10KV high voltage pulse on the output port and electric fence, dont touch it to make sure security.The user must know the related electric device knowledge, and read the user instruction and operate it carefully before install it with correct use methods, otherwise , our side dont bear any responsibility if any accident arise.Once abnormal case happen, should make sure the power off, then professional staffs check and analysis repair or contact our company, dont repack it by your own.一Function and feature There are two kinds of existing security products. One kind is a fence, like traditional brick wall, cement wall, glass wall, iron fence and so on, has the obvious contours, encircles the defense area, has the impediment external invasion function, but does not have the alarm and the surveillance function. Another kind is the alarm system, like the infrared correlation alarm apparatus, divulge electric cable, CCTV and so on, they have the alarm or the surveillance function, but does not have the impediment function. The smart pulse electric fence system integrate the prevents and alarm functions together, and increase the high voltage deterrent effect, not only have visible fence, but also have smart multi-zone controller, the alarm system becomes brand new perimeter security system.1.1 system function1.1.1 have complete and explicit dividing line fence,and formidable impediment and deter function.1.1.2 have low rate of false alarm function,when the outer fence alarm,the display windows rapidly display which zone suffers break,short-circuit and tamper, reflect the current condition. 1.1.3 The DC 12V alarm connection,dry contact signal output, can linkage with other security system, improve the systems safe rank. 1.1.4 distinction function of electric fence and can detect all kinds of invasion rank, can differentiate the accidental invade from forceful invade ability. The accidental intruder see the alarm or suffer from the electric shock, the leave, the alarm apparatus do not send out alarm. The intruder invade forcefully , so that the electric fence will be destroyed, in this case, the system will send out alarm. Only the intruder really invade and destroy the system, then will send alarm, will not alarm mistakenly and fails to alarm. 1.2 system feature 1.2.1 Absolute safety and alarm perceive The traditional high voltage pulse electric net system doesnt have alarm perceive function, only through high voltage, strong current to impediment intruder. It is very easy to get intruder disable, even dies and so serious results. The smart pulse electric fence system adopts low energy pulse high voltage((510KV),because the energy is extremely low,the response time is extremely short, will not cause the damage to the humanbody. Once touched, will just leave dut to electric shock. 1.2.2 The low rate of false alarm and strong Adaptability The smart pulse electric fence system is not affected by environment (for example. trees, animals, shake.etc ) and climate ( wind, snow, rain and fog,etc) and not limited by terrain height and winding degree. The rate of false alarm is very low. 1.2.3 impediment and alarm dual function The new concept of smart pulse electric fence system is to prevent the intruder out of from the fence area,without the crime is the goal, give the intruder one kind of deterrent feeling and impediment function, dare not act rashly, achieve the security, reduces the crime.1.2.4 continuous work,set armed/disarmed .1.2.5 use the 12V/4Ah battery as backup power supply,when the power supply is off,can work continually. 1.2.6 According to users request and site geographical environment, carry out the design and installation, and work with multiple modern security products, such as CCTV monitored system, television supervisory system and GSM system to improve the system security ranks.1.2.7 Absolute safety, conforms to the international CE certification and is also in conformity with IEC 60335-2-76 and the GB/T7946-2008 request, and get approved from public security form test. 二、product instructions 2.1 product design basis: GB/T7946-2008 Pulse electric fence installation And Safe operation2.2 product characteristic: difference voltage output technology: every wire has voltage, have the differential voltage between the two adjacent wires. LCD display the monitor state indicating the voltage on every wire. high/low voltage switch manually, long-distance equipment auto switch function. short circuit, break and tamper alarm, equipment fault auto-detect. waterproof casing and downward appearance design guiding the industry development. RS 485 main line control, keypad, computer, network and multiple long distance management solution. DC12V, open/close dry contact alarm output, can work with other modern security products. 2.3 product technical index 2.3.1 power supply: AC180V-240v 50Hz 2.3.2 use environment 2.3.2.1 Temperature :-40-+502.3.2.2 moisture: :95% 2.3.3 output index: Output peak voltage: 5KV10KV Output low voltage: 7001000V Peak current of pulse: 10A Pulse duration: 0.1s Pulse interval time: 1s Max quantity of electricity of pulse: 2.5mC Max energy of pulse: 5.0J System power consumption: 10w 2.4 LED indicated lamp condition instructions:2.4.1 AC 220V or DC12V,when power supply input ,the green indicated lamp is bright. 2.4.2 when armed,the yellow indicated lamp is bright. When disarmed,it shows off. 2.4.3 when alarm break,the red indicated lamp is bright. 2.4.4 when alarm short circuit,the red indicated lamp is bright 2.4.5 when open cover, the red indicated lamp of tamper is bright. 2.5 the front and bottom of controller instructions.2.6 the wire connection of controller instruction( above drawing)2.6.1 the controller comprise two parts: input and output,the positive pulse from output part”1st line high voltage output port” transfer to fence wire, then return back to the receiver part “ 1st line high voltage input port”, negative pulse from output”2nd line high voltage output port” transfer to fence wire, then return back to the receiver part” 2nd line high voltage input port” ,so form positive and negative pulse closed circuit on the front fence.2.6.2 high voltage earth output: can share the same earth output with lightning arrester, strong/weak earth separate. 2.6.3 voltage switch: use for switching high/low voltage mode or automatic working mode.2.6.4 keypad output: can connect keypad directly or RS485 transfer RS 232,then connect to computer by long distance control, The RS 485 connection of each controller needs to go hands by hands connection, multiple connection is not allowed.2.6.5 switch output: output open/close dry contact signal, needs to connect with other linkage device.2.6.6 alarm output: when alarm, output DC 12V voltage, connect with alarm device DC 12v below 10W.2.6.7 power switch: control the energizer on/off.2.6.8 power supply input: connect AC 220V power source.三、design request of electric fence 3.1 according to different security rank, configurate suitable electric fence,usually divide into 、III the three rank. general security rank, uses 4 lines system, the monitor zone partition does not surpass 500 meters. medium security rank, uses 8 lines system, the monitor zone partition does not surpass 250 meters.III higher security rank, uses 12 lines system, the monitor zone partition does not surpass 100 meters.Every zone must configurate independent controller, and have different triggered alarm apparatus, can indicate the alarm zone number. The alarm output usually linkage with CCTV, red-infrared correlation, spotlight, alarm apparatus etc. When applied, the length of monitor zone should set according to the perimeter total length, the terrain and the objective site environment. 3.2 Security 3.2.1 dont allow get the AC power supply on electric fence. when the product gets faulty, please make sure the electric fence without any AC power supply.3.2.2 product used the rectification voltage dropping DC 12V, then voltage-rise to condenser charge, finally electric capacity pulse discharge boosting transformer, the output energy is limited by rectification, primary voltage-rise, electric capacitance discharge, so many links, without harm to human body and absolute safety.3.2.3 association factor and the influence of electric shock: The electric pulse will not injure the intruder, to avoid the associated responsibility, firstly, electric fence warning signs should hang up at every other 10 meters striking position noted” electric fence, forbid climbing”, secondly, the height of electric fence should be above 1.8meters, if the height of electric fence is not high, should install isolated netting or wall to avoid accident.3.2.4 electric fence should not be with other power circuit and telecommunication wires on the same pole.3.2.5 electric fence should keep a certain safe distance from the power circuit. The minimum distance as shown in the table 3-1 Electric cable voltage rankhorizontal distance with electric fencevertical distance with electric fence 10KV below2.5m2m35110KV5m3m220KV 7m4m330KV 9m5m500KV9m5m3.2.6 horizontal distance between electric fence and public rod border should be above 5m( except the electric fence on top of the wall)3.2.7 electric fence has pulse high voltage, when bad connection or close to charged conductor, will have fire spark. Thus, electric fence should install without any flammable gas, and without any flammable fluid place. According to the related national standard, keep enough safe distance, or take the safe measures to isolate.3.2.8 When inspect the place to install electric fence, pls make sure the electric fence without any conflict with the electric wire, pipeline from the ground. And without any sundry goods at nearby place, whether the electric fence is influenced strongly by transmitting station and other high frequency device. If have, must mark the signal wire with STP shielded twisted pair at the construction drawing. 四、 Electric fence install 4.1 install mode: 4.1.1 install on top of the wall. Install the electric fence on top of wall, the height of fence wall should be above 1.8meters, the wire pole/rod may have welding ,clip or buried the three modes, should choose suitable mode according to the fence structure condition.For example, install at the steel fence, can take the welding, install at the concrete wall, can take buried mode to make sure stable, artistic, may use other modes also. 4.1.2 The attached install The installation attaches on the fence or top or inside, the fence wall directly withstanding the pressure and wire tension, before installation, p
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年高校教师资格证之《高等教育法规》预测试题附答案详解(预热题)
- 2025年银行岗位试题预测试卷及完整答案详解(全优)
- 平安银行武汉市洪山区2025秋招笔试创新题型专练及答案
- 广发银行安阳市北关区2025秋招笔试英语题专练及答案
- 2025年心血管内科实验诊断与临床应用试题答案及解析
- 招商银行北京市门头沟区2025秋招数据分析师笔试题及答案
- 民生银行济宁市兖州区2025秋招笔试英语题专练及答案
- 农发行德州市宁津县2025秋招无领导小组面试案例库
- 2025年银行岗位题库(考点精练)附答案详解
- 平安银行杭州市余杭区2025秋招笔试英语题专练及答案
- 2025秋人教鄂教版(2024)科学一年级第一单元走近科学《1“钓鱼”游戏》 教学设计
- 食品腐烂变质安全培训课件
- 隧道施工车辆安全培训课件
- DB31/T 1173-2019咖啡厅(馆)等级划分与评定
- 控制阀培训课件
- 湘菜湖南美食文化介绍PPT
- 外科学外科休克PPT
- 浙人美2011版四年级美术上册《水资源》教案及教学反思
- 全桥LLC自动计算表格
- 魔芋怎么种?魔芋的种植技术
- GB/T 26766-2011城市公共交通调度车载信息终端
评论
0/150
提交评论