




已阅读5页,还剩23页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
平台硬件管理,4,ftServerUptimeManager,DesignedforContinuousAvailabilityFaultTolerantServices(FTS)ConstantlymonitorsthesystemandrespondstohardwareeventsAutomaticallymaintainsMTBFstatisticsInterfaceswiththeStratusActiveServiceNetwork(ASN)Providescommand-lineutilitiesformanagingthesystemcomponents,2,HardwarePaths,Numericvaluesthatidentifyspecificcomponents.DeviceIDsarelistedformostdevices.DeviceIDsareseparatedbyslashes(/)Examples:10/40/111/7PCIeaddressesarelistedforsomedevicesPCIeaddressesareseparatedbycolons(:)anddots(.)BusNumber:Device.FunctionExamples:06:00.07b:00.0Networkinterfacesareassignednames,suchaseth100200,byAutomatedUptimeLayer.SeeChapter6fordetails.,3,DeviceIDs,ProvideidentificationforhardwarecomponentsSpecifyaddressesofhardwarecomponentsConsistofnumericalstringsofhardwareaddresses,startingfrommainbus,4,ftServerDeviceIDs:Examples,5,Fault-TolerantDeviceStates,6,Online,ERROR,Missing,Offline,PATHVariable,Theftsmaintutilityisinthe/opt/ft/bindirectory.Theft-bonding,VTMConfig,andASNConfigcommandsareinthe/opt/ft/sbindirectory.AddbothofthesedirectorypathstothePATHvariable,7,TheftsmaintCommand,/opt/ft/bin/ftsmaintUseftsmainttoexamineandcontrolfault-tolerantsettingsofhardwarecomponentsonasystem.SetyourPATHenvironmentvariabletoincludethisdirectoryandthe/opt/ft/sbindirectory.#exportPATH=$PATH:/opt/ft/bin:/opt/ft/sbinToviewthemanualpage:#manftsmaint,8,ftsmaintSyntax,Synopsis/opt/ft/bin/ftsmaintcmdpathSomeftsmaintCommandslspathDisplaysstatusandlonglistofthedevicebringUppathBringsthedeviceintoservicebringDownpathTakesthedeviceoutofservicerunDiagpathPerformsdiagnosticsonthedeviceacSwitchpathSwitchestheactivecompatibilitytoI/OelementatpathmemCheckTeststheintegrityofsystemmemorySeetheStratusftServerSystemAdministratorsGuidefortheLinuxOperatingSystem(R003L)fordescriptionsofmorecommands.,9,ftsmaintExamples,10,Tolistdetailsaboutthedeviceatthespecifichardwarepath,oralldevicesifpathisomitted:/opt/ft/bin/ftsmaintlspathTodisplaydetailedstatusofaspecificdevice:ftsmaintls10Toremoveadevicefromservice:ftsmaintbringDown11/40/2Tobringadeviceintoservice:ftsmaintbringUp11/40/2ToswitchActiveCompatibility:ftsmaintacSwitch,ftsmaintls,H/WPathDescriptionStateOPStateFRevFct=0CombinedCPU/IOONLINEDUPLEX*00/1DIMMONLINEONLINE-0/2DIMMONLINEONLINE-0/3DIMMONLINEONLINE-0/4DIMMONLINEONLINE-0/5DIMMONLINEONLINE-0/6DIMMONLINEONLINE-0/7DIMMONLINEONLINE-0/8DIMMONLINEONLINE-0/9DIMMONLINEONLINE-0/10DIMMONLINEONLINE-0/11DIMMONLINEONLINE-0/12DIMMONLINEONLINE-0/13DIMMONLINEONLINE-0/14DIMMONLINEONLINE-0/15DIMMONLINEONLINE-0/16DIMMONLINEONLINE-0/21Intel(R)Xeon(R)CPUE5-260301.80GHzONLINEONLINE-0/22Intel(R)Xeon(R)CPUE5-260301.80GHzONLINEONLINE-0/130BaseboardTemp#0Sensor-NORMAL-0/140BaseboardFan1#0Sensor-NORMAL-0/141BaseboardFan2#0Sensor-NORMAL-0/142BaseboardFan3#0Sensor-NORMAL-0/143BaseboardFan4#0Sensor-NORMAL-0/144BaseboardFan5#0Sensor-NORMAL-,11,ftsmaintls(Continued),1CombinedCPU/IOONLINEDUPLEX*01/1DIMMONLINEONLINE-1/2DIMMONLINEONLINE-1/3DIMMONLINEONLINE-1/4DIMMONLINEONLINE-1/5DIMMONLINEONLINE-1/6DIMMONLINEONLINE-1/7DIMMONLINEONLINE-1/8DIMMONLINEONLINE-1/9DIMMONLINEONLINE-1/10DIMMONLINEONLINE-1/11DIMMONLINEONLINE-1/12DIMMONLINEONLINE-1/13DIMMONLINEONLINE-1/14DIMMONLINEONLINE-1/15DIMMONLINEONLINE-1/16DIMMONLINEONLINE-1/21Intel(R)Xeon(R)CPUE5-260301.80GHzONLINEONLINE-1/22Intel(R)Xeon(R)CPUE5-260301.80GHzONLINEONLINE-1/130BaseboardTemp#1Sensor-NORMAL-1/140BaseboardFan1#1Sensor-NORMAL-1/141BaseboardFan2#1Sensor-NORMAL-1/142BaseboardFan3#1Sensor-NORMAL-1/143BaseboardFan4#1Sensor-NORMAL-1/144BaseboardFan5#1Sensor-NORMAL-,12,ftsmaintls(Continued),13,10CombinedCPU/IOONLINEDUPLEX-010/1NetworkCtlrONLINEDUPLEX-00c:00.0Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth100100NetworkInterfaceONLINEDUPLEX-0c:00.1Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth100101NetworkInterfaceONLINEDUPLEX-10/2-MISSINGEMPTY-10/3-MISSINGEMPTY-10/4-MISSINGEMPTY-10/5MassStorageCtlrONLINEDUPLEX-00b:00.0SerialAttachedSCSIcontroller:LSILogicONLINEDUPLEX-10/6NetworkCtlrONLINEDUPLEX-007:00.0Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth100600NetworkInterfaceONLINEDUPLEX-07:00.1Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth100601NetworkInterfaceONLINEDUPLEX-10/7DisplayCtlrONLINEDUPLEX-00a:00.0VGAcompatiblecontroller:MatroxElectroONLINEDUPLEX-10/8SerialBusCtlrsONLINEONLINE-02c:00.0USBController:IntelCorporationC600/X7ONLINEONLINE-2c:00.1USBController:IntelCorporationC600/X7ONLINEONLINE-10/10-ONLINEONLINE-010/11-ONLINEONLINE-0,ftsmaintls(Continued),14,10/12NetworkCtlrONLINEDUPLEX-07d:00.0Ethernetcontroller:IntelCorporationEtONLINEONLINE-eth101200NetworkInterfaceONLINEDUPLEX-7d:00.1Ethernetcontroller:IntelCorporationEtBROKENBROKEN-eth101201NetworkInterfaceBROKENBROKEN-10/40InternalDiskEnclosure-10/40/1DiskDriveONLINEDUPLEX0102010/40/2DiskDriveONLINEDUPLEX0004010/40/3DiskDriveONLINEDUPLEX0102010/40/4DiskDriveONLINEDUPLEX0102010/40/5DiskDriveONLINEDUPLEX0004010/40/6DiskDriveONLINEDUPLEX0004010/40/7DiskDriveONLINEDUPLEX0004010/40/8DiskDriveONLINEDUPLEX0004010/702xPCI-E2(X4)RiserCard-10/120BaseboardManagementCtlrONLINEDUPLEX*-,ftsmaintls(Continued),15,11CombinedCPU/IOONLINEDUPLEX-011/1NetworkCtlrONLINEDUPLEX-046:00.0Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth110100NetworkInterfaceONLINEDUPLEX-46:00.1Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth110101NetworkInterfaceONLINEDUPLEX-11/2-MISSINGEMPTY-11/3-MISSINGEMPTY-11/4-MISSINGEMPTY-11/5MassStorageCtlrONLINEDUPLEX-045:00.0SerialAttachedSCSIcontroller:LSILogicONLINEDUPLEX-11/6NetworkCtlrONLINEDUPLEX-041:00.0Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth110600NetworkInterfaceONLINEDUPLEX-41:00.1Ethernetcontroller:IntelCorporation82ONLINEONLINE-eth110601NetworkInterfaceONLINEDUPLEX-11/7DisplayCtlrONLINEDUPLEX-044:00.0VGAcompatiblecontroller:MatroxElectroONLINEDUPLEX-11/8SerialBusCtlrsONLINEONLINE-066:00.0USBController:IntelCorporationC600/X7ONLINEONLINE-66:00.1USBController:IntelCorporationC600/X7ONLINEONLINE-11/10-ONLINEONLINE-011/11-ONLINEONLINE-0,ftsmaintls(Continued),16,11/12NetworkCtlrONLINEDUPLEX-0b7:00.0Ethernetcontroller:IntelCorporationEtONLINEONLINE-eth111200NetworkInterfaceONLINEDUPLEX-b7:00.1Ethernetcontroller:IntelCorporationEtBROKENBROKEN-eth111201NetworkInterfaceBROKENBROKEN-11/40InternalDiskEnclosure-11/40/1DiskDriveONLINEDUPLEX0102011/40/2DiskDriveONLINEDUPLEX0004311/40/3DiskDriveONLINEDUPLEX0102111/40/4DiskDriveONLINEDUPLEX0102111/40/5DiskDriveONLINEDUPLEX0004111/40/6DiskDriveONLINEDUPLEX0004111/40/7DiskDriveONLINEDUPLEX0004211/40/8DiskDriveONLINEDUPLEX0004211/702xPCI-E2(X4)RiserCard-11/120BaseboardManagementCtlrONLINEDUPLEX*-IOEnclosure11istheActiveCompatibilityNode.ThisisanftServer4700system,P-PackageP4700-2S,Serial#2200008.*UselsLongtoseethisvalue.,UpdatingftServerFirmware,BMC(BaseboardManagementControllerchip)TocheckthecurrentBMCversion:#/opt/ft/bin/ftsmaintls10/120TofindlatestBMCimagefile:OntheAutomatedUptimeLayerdistributionCD:firmware/bmc/2700_4700_6400Onsystem:/opt/ft/firmware/bmc/2700_4700_6400BIOSTocheckthecurrentBIOSversion:#/opt/ft/bin/ftsmaintls0TofindthelatestBIOSimagefile:OntheAutomatedUptimeLayerdistributionCD:firmware/bios/2700_4700_6400Onsystem:/opt/ft/firmware/bios/2700_4700_6400ChecktheWebsiteforthemostrecentfirmwarenumbers:O,17,UpdatingftServerFirmware(Continued),Todownloadthefirmware:O,clickSERVICES,thenCustomerSupport,StratusServerSupportDocuments,FTPDownloads,andthenftServerSystems.OrentertheURLftp:/CPU-I/Oenclosure.,18,UpdatingBMCFirmware,Logonasroot.ObtaintheBMCfirmwarefileeitherbydownloadingitfromftp:/UptimeLayerCD.Ifyoudownloadthefiletotherootdirectory,continuewithstep3.IfyoucopyfromtheCD,performstepsaandb:InserttheCDintotheDVDdrive.Ifyoursystemisrunningagraphicaldesktop,theCDautomounts.Ifyoursystemisnotrunningagraphicaldesktop,mounttheDVDdrivebytypingthefollowingcommand.#mount/dev/cdrom/media/Automated_Uptime_(TM)_Layer_ins,19,UpdatingBMCFirmware(Continued),CopytheBMCfirmwarefiletotherootdirectoryusingthecommandbelow.Forfw_filename,substitutetheactualfilename,whichisintheformat:062-02799bmc_bnn.nnrnn.nnpnn.nnsnn.nn.bin#cp/media/Automated_Uptime_(TM)_Layer_ins/firmware/bmc/2700_4700_6400/fw_filename/root/fw_filenameIfyoumountedtheDVDdriveinstepa,unmountitbytypingthefollowingcommand:#umount/media/Automated_Uptime_(TM)_Layer_insUpdatethefirmwareonbothBMCsbytypingacommandsimilartothefollowing:#/opt/ft/bin/ftsmaintburnBmcs/root/fw_filenameThiscommandtakesabout15minutestocomplete.,20,UpdatingBMCFirmware(Continued),TypethefollowingcommandstoverifythatyourBMCfirmwareisupdated.ComparetheFirmwareRevvalues,asshowninthefollowingtruncatedsampleoutput.#/opt/ft/bin/ftsmaintls10/120FirmwareRev:02.18/00.09/01.13#/opt/ft/bin/ftsmaintls11/120FirmwareRev:02.18/00.09/01.13TypethefollowingcommandstoverifythattheI/Oelementsareduplexed(verifythattheOpStateisDUPLEX):#/opt/ft/bin/ftsmaintls10#/opt/ft/bin/ftsmaintls11,21,UpdatingtheBIOS,Logonasroot.VerifythatthePRIMARYLEDislit(green)ontheupperCPUI/Oenclosure.Then,ifthesystemisnotalreadypoweredon,liftthepower-switchcoverandpresstheswitchfor2or3secondstostartthesystem.IfthelowerCPUI/OenclosureistheonewhosePRIMARYLEDislit,typethefollowingcommandtomaketheupperenclosureprimary:#/opt/ft/bin/ftsmaintacswitch10,22,UpdatingtheBIOS(Continued),ObtaintheBIOSfirmwarefileeitherbydownloadingitfromftp:/UptimeLayerCD.Ifyoudownloadedthefiletotherootdirectory,continuewithstep4.TocopyitfromtheCD,performstepsaandb:InserttheCDintotheDVDdrive.Ifyoursystemisrunningagraphicaldesktop,theCDautomounts.Ifyoursystemisnotrunningagraphicaldesktop,mounttheDVDdrivebytypingthefollowingcommand.#mount/dev/cdrom/media/Automated_Uptime_(TM)_Layer_ins,23,UpdatingtheBIOS(Step3,continued),CopytheBIOSfirmwarefiletotherootdirectoryusingthecommandbelow.Forfw_filename,substitutetheactualnameofthefile.Thefilenameisintheformat062-02799biosn.n.n.rom,wheren.n.nrepresentstheBIOSversionnumber.#cp/media/Automated_Uptime_(TM)_Layer_ins/firmware/bios/2700_4700_6400/fw_filename/root/fw_filenameIfyoumountedtheDVDdriveinstepa,unmountitbytypingthefollowingcommand:#unmount/media/Automated_Uptime_(TM)_Layer_ins,24,UpdatingtheBIOS(Continued),Usethefollowingcommandtoverifythatyoursyste
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年高压环网柜项目立项申请报告模板
- 2024年杭州市公务员考试行测试卷历年真题有完整答案详解
- 2025年农业灌溉用水高效管理及水资源利用效率评估报告
- 2024年和田地区公务员考试行测试卷历年真题及答案详解(有一套)
- 2024年和田地区公务员考试行测真题完整参考答案详解
- 远程医疗助力2025年偏远地区医疗服务中的医疗信息化安全策略报告
- 网络直播行业规范化后2025年直播+健身模式创新与发展报告
- 2025银发消费市场养老服务需求与产业融合报告
- 2025年中国家用除湿机行业市场发展监测及投资潜力预测报告
- 2025年碳素产品项目安全风险评价报告
- 2025家庭装饰装修合同范本
- 农村自建房流程
- 医生护士家长进课堂助教儿童医学小常识课件
- 《农药经营许可培训班》考试试卷
- 安徽省技能人才评价考评员考试题库
- DB32∕T 4170-2021 城市轨道交通车辆基地上盖综合利用防火设计标准
- 《湖北省中小学生命安全教育课程标准》
- (完整)初中物理电学中常见的列方程计算归类
- 浙江省2016年10月物理学业水平考试试题
- 苏州大学物理化学真题
- 内科常见病、多发病的急诊处理、诊疗规范及转诊要求
评论
0/150
提交评论