丹佛斯FC300系列变频器参数讲解_第1页
丹佛斯FC300系列变频器参数讲解_第2页
丹佛斯FC300系列变频器参数讲解_第3页
丹佛斯FC300系列变频器参数讲解_第4页
丹佛斯FC300系列变频器参数讲解_第5页
已阅读5页,还剩144页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1,2,参数表,安装编程参数0-*操作和显示1-*负载和电机2-*制动3-*参考值/加减速4-*限制/警告5-*数字输入/输出6-*模拟输入/输出7-*PID控制器13-*智能逻辑控制器14-*特殊功能15-*变频器信息16-*数据读出17-*编码器,警告(WARNING)和报警(ALARM)选件和附件,3,Installation,MechanicalInstallation,Backtocontent,4,Installation,MechanicalInstallation,Backtocontent,5,外壳类型,MechanicalInstallation,Backtocontent,6,Installation,ElectricalInstallation,强电端子,电机端子,电源端子,制动及负载共享,继电器,LC滤波器,外部24V供电,Backtocontent,7,Installation,ElectricalInstallation,Controlteminals,Backtocontent,8,Installation,ElectricalInstallation,Tensionspringtechnology,接线,拆线,连接,Backtocontent,9,Installation,ElectricalInstallation,ControlTerminalDiagram,Backtocontent,10,Installation,ElectricalInstallation,Backtocontent,11,Installation,ElectricalInstallation,开关S201,S202,andS801开关S201(A53)、S202(A54)用来选择53/54端子的电流(0-20mA)或电压输入(-10to10V)开关S801(BUSTER.)是RS-485口的终端电阻开关(terminals68and69).默认值:S201(A53)=OFF(电压input)S202(A54)=OFF(电压input)S801(终端电阻)=OFF,断电状态下拨动开关,拨动时最好摘下面板的底托,小心用力!,Backtocontent,12,暗,Status,显示亮度,Programming,OperatingInstruction,恢复出厂值,按住同时上电,保持5秒(orP.14-22),Orpressfor3s,快捷(directaccess),MainMenu,MainMenu,-Key,1xpushing-lastchangedParameter2xpushing-Mainmenu,Importantsettings:,Backtocontent,13,Programming,QuickMenu,Backtocontent,14,Programming,MenuStructure,Backtocontent,15,Programming,Example,2-0*DC-Hold/DC.2-1*Overvoltage2-2*Mech.Brake,Brakefunctionen,16-0*Readout-All16-1*Readout-M16-3*ReadoutF16-5*Readout-S,Datereadouts,Backtocontent,16,Programming,ArrayParameter,ArrayNumber,ArrayValue,Back,Back,Cancel,or,Ok,or,ArrayInput,Backtocontent,17,ParametersOperationandDisplay,Group0OperationandDisplay,0-01Language,Value:,*English(ENGLISH)0German(DEUTSCH)1French(FRANCAIS)2Danish(DANSK)3Spanish(ESPANOL)4Italian(ITALIANO)5Swedish(SWEDISH)6Dutch(DUTCH)7Chinese(CHINESE)10,Finnish(FINNISH)20EnglishUS(ENGLISHUS)22Greek(GREEK)27Portuguese(PORTUGUESE)28Slovenian(SLOVENIAN)36Korean(KOREAN)39Japanese(JAPANESE)40Turkish(TURKISH)41TraditionalChinese42Bulgarian43,Serbian44Romanian(ROMANIAN)45Hungarian(HUNGARIAN)46Czech47Polish(POLISH)48Russian49Thai50BahasaIndonesian(BAHASAINDONESIAN)51,0-0*Operation/DisplayParametersrelatedtothefundamentalfunctionsofthefrequencyconverter,functionoftheLCPbuttonsandconfigurationoftheLCPdisplay.0-0*BasicSettingsParametergroupforbasicfrequencyconvertersettings.,Backtocontent,18,ParametersOperationandDisplay,Group0OperationandDisplay,0-02MotorSpeedUnit,Value:,*RPM0Hz1,Selectdisplayofmotorspeedparameters(i.e.references,feedbacksandlimits)intermsofshaftspeed(RPM)oroutputfrequencytothemotor(Hz).,Backtocontent,0-03RegionalSettings,Value:,*International0US1,SelectInternational0tosetpar.1-20MotorPowerunitstokWandthedefaultvalueofpar.1-23MotorFrequencyto50Hz.SelectUS1tosetpar.1-21MotorPowerunitstoHPandthedefaultvalueofpar.1-23MotorFrequencyto60Hz.,19,ParametersOperationandDisplay,Group0OperationandDisplay,0-10ActiveSet-up,Value:,0-1*Set-upOperationsDefineandcontroltheindividualparametersetups.,Factorysetup0*Set-up11Set-up22Set-up33Set-up44Multiset-up9,Selecttheset-uptocontrolthefrequencyconverterfunctions.FactorySet-up0cannotbechanged.ItcontainstheDanfossdataset,andcanbeusedasadatasourcewhenreturningtheotherset-upstoaknownstate.Set-up11toSet-up44arethefourseparateparameterset-upswithinwhichallparameterscanbeprogrammed.SelectActiveSet-up9forremoteselectionofset-upsusingdigitalinputsandtheserialcommunicationport.Thisset-upusesthesettingsfrompar.0-12Thisoptionlinkedto.Stopthefrequencyconverterbeforemakingchangestoopenloopandclosedloopfunctions.Usepar.0-51Set-upcopytocopyaset-uptooneorallotherset-ups.,Stopthefrequencyconverterbeforeswitchingbetweenset-upswhereparametersmarkednotchangeableduringoperationhavedifferentvalues.Toavoidconflictingsettingsofthesameparameterwithintwodifferentsetups,linktheset-upstogetherusingpar.0-12Thisset-uplinkedto.ParameterswhicharenotchangeableduringoperationaremarkedFALSEintheparameterlistsinthesectionParameterLists.,Backtocontent,20,ParametersOperationandDisplay,Group0OperationandDisplay,0-11EditSet-up,Value:,Selecttheset-uptobeedited(grammed)duringoperation;eithertheactiveset-uporoneoftheinactiveset-ups.Factoryset-up0cannotbeeditedbutitisusefulasadatasourcetoreturntheotherset-upstoaknownstate.Set-up11toSet-up44canbeeditedfreelyduringoperation,independentlyoftheactiveset-up.TheActiveset-up9canalsobeeditedduringoperation.Editthechosenset-upfromarangeofsources:LCP,FCRS485,FCUSBoruptofivefieldbussites.,Factorysetup0*Set-up11Set-up22Set-up33Set-up44Activeset-up9,Backtocontent,21,ParametersOperationandDisplay,Group0OperationandDisplay,0-12ThisSet-upLinkedto,Value:,Toenableconflict-freechangesfromoneset-uptoanotherduringoperation,linkset-upscontainingparameterswhicharenotchangeableduringoperation.Thelinkwillensuresynchronisingofthenotchangeableduringoperationparametervalueswhenmovingfromoneset-uptoanotherduringoperation.NotchangeableduringoperationparameterscanbeidentifiedbythelabelFALSEintheparameterlistsinthesectionParameterLists.Thepar.0-12linkset-upfeatureisusedbyMultiset-upinpar.0-10ActiveSet-up.Multiset-upisusedtomovefromoneset-uptoanotherduringoperation(i.e.whilethemotorisrunning).,*Notlinked0Set-up11Set-up22Set-up33Set-up44,Backtocontent,22,ParametersOperationandDisplay,Group0OperationandDisplay,Example:UseMultiset-uptoshiftfromSet-up1toSet-up2whilstthemotorisrunning.ProgrammeinSetup1first,thenensurethatSet-up1andSet-up2aresynchronised(or.linked.).Synchronisationcanbeperformedintwoways:1.Changetheeditset-uptoSet-up22inpar.0-11EditSet-upandsetpar.0-12ThisSet-upLinkedtotoSet-up11.Thiswillstartthelinking(synchronising)process.,OR2.WhilestillinSet-up1,copySet-up1toSet-up2.Thensetpar.0-12toSet-up22.Thiswillstartthelinkingprocess.,Afterthelinkiscomplete,par.0-13Readout:LinkedSet-upswillread1,2toindicatethatallnotchangeableduringoperationparametersonarenowthesameinSet-up1andSet-up2.Iftherearechangestoa.notchangeableduringoperation.parameter,e.g.par1-30StatorResistance(rs),inSet-up2,theywillalsobechangedautomaticallyinSet-up1.AswitchbetweenSetup1andSet-up2duringoperationisnowpossible.,Backtocontent,23,ParametersOperationandDisplay,Group0OperationandDisplay,0-13Readout:LinkedSet-ups,Value:,Array5,0-255*0,Viewalistofalltheset-upslinkedbymeansofpar.0-12ThisSet-upLinkedto.Theparameterhasoneindexforeachparameterset-up.Eachset-upshowstheset-upbitsettowhichitislinked.,Backtocontent,24,ParametersOperationandDisplay,Group0OperationandDisplay,0-2*LCPDisplayDefinethedisplayintheGraphicalLogicControlPanel.,None0ProfibusWarningWord953ReadoutTransmitErrorCounter1005ReadoutReceiveErrorCounter1006ReadoutBusOffCounter1007WarningParameter1013RunningHours1501kWhCounter1502ControlWord1600ReferenceUnit1601Reference%1602StatusWord1603MainActualValue%1605CustomReadout1609PowerkW1610Powerhp1611MotorVoltage1612Frequency1613MotorCurrent1614Frequency%1615Torque1616*SpeedRPM1617MotorThermal1618KTYSensorTemperature1619MotorAngle1620,PhaseAngle1621Torque%1622DCLinkVoltage1630BrakeEnergy/s1632BrakeEnergy/2min1633HeatsinkTemp.1634InverterThermal1635Inv.Nom.Current1636Inv.Max.Current1637SLControlState1638ControlCardTemp.1639ExternalReference1650PulseReference1651FeedbackUnit1652DigiPotReference1653DigitalInput1660Terminal53SwitchSetting1661AnalogInput531662Terminal54SwitchSetting1663AnalogInput541664AnalogOutput42mA1665DigitalOutputbin1666Freq.Input#29Hz1667Freq.Input#33Hz1668,Backtocontent,25,ParametersOperationandDisplay,Group0OperationandDisplay,0-2*LCPDisplayDefinethedisplayintheGraphicalLogicControlPanel.,Freq.Input#33Hz1668PulseOutput#27Hz1669PulseOutput#29Hz1670RelayOutputbin1671CounterA1672CounterB1673Prec.StopCounter1674FieldbusCTW11680FieldbusREF11682Comm.OptionSTW1684FCPortCTW11685FCPortREF11686AlarmWord1690AlarmWord21691WarningWord1692WarningWord21693Ext.StatusWord1694Ext.StatusWord21695PCD1WritetoMCO3401PCD2WritetoMCO3402PCD3WritetoMCO3403PCD4WritetoMCO3404PCD5WritetoMCO3405PCD6WritetoMCO3406,PCD7WritetoMCO3407PCD8WritetoMCO3408PCD9WritetoMCO3409PCD10WritetoMCO3410PCD1ReadfromMCO3421PCD2ReadfromMCO3422PCD3ReadfromMCO3423PCD4ReadfromMCO3424PCD5ReadfromMCO3425PCD6ReadfromMCO3426PCD7ReadfromMCO3427PCD8ReadfromMCO3428PCD9ReadfromMCO3429PCD10ReadfromMCO3430DigitalInputs3440DigitalOutputs3441ActualPosition3450CommandedPosition3451ActualMasterPosition3452SlaveIndexPosition3453MasterIndexPosition3454CurvePosition3455TrackError3456SynchronizingError3457,Backtocontent,26,ParametersOperationandDisplay,Group0OperationandDisplay,0-2*LCPDisplayDefinethedisplayintheGraphicalLogicControlPanel.,ActualVelocity3458ActualMasterVelocity3459SynchronizingStatus3460AxisStatus3461ProgramStatus3462,IdleTime9913ParamdbRequestsinQueue9914AnaloginputX30/111675AnaloginputX30/121676AnalogoutputX30/8mA1677,*SpeedRPM1617,*MotorCurrentA1614,*PowerKW1610,Backtocontent,27,ParametersOperationandDisplay,Group0OperationandDisplay,*FrequencyHz1613,*Reference%1602,0-25个人菜单,Value:,Array20,0-9999,最多可以定义50个显示在Q1个人菜单中的参数。该菜单可通过LCP上QuickMenu键访问。如果设为0000则会删除该参数。,Backtocontent,28,ParametersOperationandDisplay,Group0OperationandDisplay,Disabled0*Enabled1Password2,SelectDisabled0toavoidaccidentalstartofthefrequencyconverterinHandmode.SelectPassword2toavoidunauthorisedstartinHandmode.Ifpar.0-40isincludedintheQuickMenu,thendefinethepasswordinpar.0-65QuickMenuPassword.,0-4*LCPKeypadEnableanddisableindividualkeysontheLCPkeypad.,Disabled0*Enabled1Password2,SelectDisabled0toavoidaccidentalstopofthefrequencyconverter.SelectPassword2toavoidunauthorisedstop.Ifpar.0-41isincludedintheQuickMenu,thendefinethepasswordinpar.0-65QuickMenuPassword.,Backtocontent,29,ParametersOperationandDisplay,Group0OperationandDisplay,Disabled0*Enabled1Password2,SelectDisabled0toavoidaccidentalstartofthefrequencyconverterinAutomode.SelectPassword2toavoidunauthorisedstartinAutomode.Ifpar.0-40isincludedintheQuickMenu,thendefinethepasswordinpar.0-65QuickMenuPassword.,Disabled0*Enabled1Password2,PressResetandselectDisabled0toavoidaccidentalalarmreset.PressResetandselectPassword2toavoidunauthorisedresetting.Ifpar.0-43isincludedintheQuickMenu,thendefinethepasswordinpar.0-65QuickMenuPassword.,Backtocontent,30,ParametersOperationandDisplay,Group0OperationandDisplay,0-5*Copy/SaveCopyparametersettingsbetweenset-upsandto/fromtheLCP.,*Nocopy0AlltoLCP1AllfromLCP2Sizeindep.fromLCP3FilefromMCOtoLCP4FilefromLCPtoMCO5,SelectAlltoLCP1tocopyallparametersinallset-upsfromthefrequencyconvertermemorytotheLCPmemory.SelectAllfromLCPall2tocopyallparametersinallset-upsfromtheLCPmemorytothefrequencyconvertermemory.SelectSizeindep.fromLCP3tocopyonlytheparametersthatareindependentofthemotorsize.Thelatterselectioncanbeusedtoprogrammeseveraldriveswiththesamefunctionwithoutdisturbingmotordata.Thisparametercannotbeadjustedwhilethemotorisrunning.,Backtocontent,31,ParametersOperationandDisplay,Group0OperationandDisplay,*Nocopy0Copytoset-up11Copytoset-up22Copytoset-up33Copytoset-up44Copytoall5,SelectCopytoset-up11tocopyallparametersinthepresenteditset-up(definedinpar.0-11EditSet-up)toSet-up1.Likewise,selecttheoptioncorrespondingtotheotherset-up(s).SelectCopytoall9tocopytheparametersinthepresentset-upovertoeachoftheset-ups1to4.,Backtocontent,32,ParametersLoadandMotor,Group1LoadandMotor,1-0*GeneralSettingsDefinewhetherthefrequencyconverteroperatesinspeedmodeortorquemode;andwhethertheinternalPIDcontrolshouldbeactiveornot.,*Speedopenloop0Speedclosedloop1Torque2Process3,SelecttheapplicationcontrolprincipletobeusedwhenaRemoteReference(viaanaloginput)isactive.ARemoteReferencecanonlybeactivewhenpar.3-13ReferenceSiteissetto0or1.Speedopenloop0:Enablesspeedcontrol(withoutfeedbacksignalfrommotor)withautomaticslipcompensationforalmostconstantspeedatvaryingloads.CompensationsareactivebutcanbedisabledintheLoad/Motorpar.group1-0*.Speedclosedloop1:Enablesencoderfeedbackfrommotor.Obtainfullholdingtorqueat0RPM.Forincreasedspeedaccuracy,provideafeedbacksignalandsetthespeedPIDcontrol.Torque2:Connectstheencoderspeedfeedbacksignaltotheencoderinput.Onlypossiblewith.Fluxwithmotorfeedback.option,par.1-01Motorcontrolprinciple.Process3:Enablestheuseofprocesscontrolinthefrequencyconverter.Theprocesscontrolparametersaresetinpar.groups7-2*and7-3*,Backtocontent,33,ParametersLoadandMotor,Group1LoadandMotor,Backtocontent,Speedcontrolopenloop,Parametersrelated0-02MotorSpeedUnit(Hz/RPM)1-01MotorControlPrinciple1-03TorqueCharacteristics3-00ReferenceRange3-02MinimumReference3-03MaximumReference3-04ReferenceFunction4-10MotorSpeedDirection4-11MotorSpeedLowLimit(RPM)4-12MotorSpeedLowLimit(Hz)4-13MotorSpeedHighLimit(RPM)4-14MotorSpeedHighLimit(Hz)4-16TorqueLimitMotorMode4-18CurrentLimit4-19MaxOutputFrequency4-50WarningCurrentLow4-51WarningCurrentHigh4-52WarningSpeedLow4-53WarningSpeedHigh4-54WarningReferenceLow4-55WarningReferenceHigh,34,ParametersLoadandMotor,Group1LoadandMotor,U/f0*VVCplus1Fluxsensorless(FC302only)2Fluxwithmotorfeedback(FC302only)3,Selectwhichmotorcontrolprincipletoemploy.SelectU/f0,aspecialmotormode,forparallelconnectedmotorsinspecialmotorapplications.WhenU/fisselectedthecharacteristicofthecontrolprinciplecanbeeditedinpar.1-55and1-56.SelectVVCplus1foraVoltageVectorControlprinciplesuitableformostapplications.ThemainbenefitofVVCplusoperationisthatitusesarobustmotormodel.SelectFluxsensorless2,i.e.FluxVectorcontrolwithoutencoderfeedback,forsimpleinstallationandrobustnessagainstsuddenloadchanges.SelectFluxwithencoderfeedback3forveryhighaccuracyspeedandtorquecontrol,suitableforthemostdemandingapplications.ThebestshaftperformanceisnormallyachievedusingeitherofthetwoFluxVectorcontrolmodesFluxsensorless2andFluxwithencoderfeedback3.,Backtocontent,35,ParametersLoadandMotor,Group1LoadandMotor,*24Vencoder1MCB1022MCB1033MCO305encoder14MCO305encoder25,Selecttheinterfaceatwhichtoreceivefeedbackfromthemotor.24Vencoder1isanAandBchannelencoder,whichcanbeconnectedtothedigitalinputterminals32/33only.Terminals32/33mustbeprogrammedtonooperation.MCB1022isanencodermoduleoptionwhichcanbeconfiguredinpar.group17-1*ThisparameterappearsinFC302only.MCB1033isanoptionalresolverinterfacemodulewhichcanbeconfiguredinparametergroup17-5*MCO305Encoder14isencoderinterface1oftheoptionalprogrammablemotioncontrollerMCO305.MCO305Encoder25isencoderinterface2oftheoptionalprogrammablemotioncontrollerMCO305.,Backtocontent,36,ParametersLoadandMotor,Group1LoadandMotor,*Constanttorque0Variabletorque1Autoenergyoptim.2,Selectthetorquecharacteristicrequired.VTandAEOarebothenergysavingoperations.Constanttorque0:Themotorshaftoutputwillprovideconstanttorqueundervariablespeedcontrol.VariableTorque1:Themotorshaftoutputwillprovidevariabletorqueundervariablespeedcontrol.Setthevariabletorquelevelinpar.14-40VTLevel.AutomaticEnergyOptimizingfunction2:Thisfunctionautomaticallyoptimisesenergyconsumptionbyminimisingmagnetisationandfrequencyviapar.14-41AEOMinimumMagnetisationandpar.14-42MinimumAEOFrequency.,Backtocontent,37,ParametersLoadandMotor,Group1LoadandMotor,*Hightorque0Normaltorque1,Hightorque0allowsupto160%overtorque.Normaltorque1isforoversizedmotorallowsupto110%overtorque.,Speedopenloop0Speedclosedloop1*Asconf.modepar.1-002,Selectwhichapplicationconfigurationmode(par.1-00),i.e.applicationcontrolprinciple,tousewhenaLocal(LCP)Referenceisactive.ALocalReferencecanbeactiveonlywhenpar.3-13ReferenceSiteissetto0or2.BydefaultthelocalreferenceisactiveinHandModeonly.,Backtocontent,38,ParametersLoadandMotor,Group1LoadandMotor,1-1*MotorselectionParametergroupforsettinggeneralmotordata.Thisparametergroupcannotbeadjustedwhilethemotorisrunning.,*Asynchronous0PM,nonsalientSPM(FC302only)1,Selectthemotordesigntype.SelectAsynchronous0forasynchronousmotors.SelectPM,nonsalientSPM(FC302only)1forpermanentmagnet(PM)motors.NotethatPMmotorsaredividedintotwogroups,witheithersurfacemounted(nonsalient)orinterior(salient)magnets.Motordesigncaneitherbeasynchronousorpermanentmagnet(PM)motor.,Backtocontent,39,ParametersLoadandMotor,Group1LoadandMotor,1-2*MotorDataParametergroup1-2*comprisesinputdatafromthenameplateontheconnectedmotor.Parametersinparametergroup1-2*cannotbeadjustedwhilethemotorisrunning.,NB!Changingthevalueoftheseparametersaffectsthesettingofotherparameters.,0.09-500kWSizerelated,EnterthenominalmotorpowerinkWaccordingtothemotornameplatedata.Thedefaultvaluecorrespondstothenominalratedoutputoftheunit.,Backtocontent,40,ParametersLoadandMotor,Group1LoadandMotor,0.09500HpSizerelated,EnterthenominalmotorpowerinHPaccordingtothemotornameplatedata.Thedefaultvaluecorrespondstothenominalratedoutputoftheunit.,101000VSizerelated,Enterthenominalmotorvoltageaccordingtothemotornameplatedata.Thedefaultvaluecorrespondstothenominalratedoutputoftheunit.,*50Hz(50HZ)5060Hz(60HZ)60Min-Maxmotorfrequency:201000Hz,Selectthemotorfrequencyvaluefromthemotornameplatedata.Alternatively,setthevalueformotorfrequencytobeinfinitelyvariable.Ifavaluedifferentfrom50Hzor60Hzisselected,itisnecessarytoadapttheloadindependentsettingsinpar.1-50to1-53.For87Hzoperationwith230/400Vmotors,setthenameplatedatafor230V/50Hz.Adaptpar.4-13MotorSpeedHighLimitRPM)andpar.3-03MaximumReferencetothe87Hzapplication.,Backtocontent,41,ParametersLoadandMotor,Group1LoadandMotor,Motortypedependent,Enterthenominalmotorcurrentvaluefromthemotornameplatedata.Thedataareusedforcalculatingtorque,motorprotectionetc.,10060000RPM*RPM,Enterthenominalmotorspeedvaluefromthemotornameplatedata.Thedataareusedforcalculatingmotorcompensations.,1.010000.0Nm*5.0Nm,Enterthevaluefromthemotornameplatedata.Thedefaultvaluecorrespondstothenominalratedoutput.Thisparameterisavailablewhenpar.1-10MotorDesignissettoPM,nonsalientSPM1,i.e.theparameterisvalidforPMandnon-salientSPMmotorsonly.

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论