




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、 MITSUBISHIINVERTER FREQROL E500INSTRUCTION MANUALCOMPACT GENERAL-PURPOSE INVERTERMITSUBISHI INVERTER INTECH一、 Basic Wiring Diagram:The basis of wiring diagram is for INTECH二、 Digital Keypad Operation:2.1 Key expression:KeyContents【RUN】Positive run command key.Built-in frequency setting deviceMay us
2、e analog method to change frequency setting【MODE】keySelection of RUN mode, setting mode【SET】keyPlease press the SET key after inputting frequency value, parameter set value.【/】keyl Continue ascend/descend adjusting key for run frequency, valid only pressing.l Press this key to make continuous change
3、 of the set value in setting mode【REV】keyReverse rotation command key【FWD】keyPositive rotation command key【STOP/RESET】keyl Run command stop keyl Inverter abnormal reset key2.2 Unit indication, run status indication:KeyContentsHZLight ON when the display value of the 7-stages monitor is frequency.ALi
4、ght ON when the display value of the 7-stages monitor is frequency.RUNLight ON during the inverter running, constant light ON when positive rotation, blinking while reverse.MONLight ON when under monitoring mode.PULight ON when under PU run mode.EXTLight ON when under external run mode.三、 Descriptio
5、n of function setting:四、Parameter setting:FunctionParameter numberNameEx-factory defaultINTECH SettingsMultiple stage selectionVR adjustmentBasic function0Manual torque compensation (note 1)6%4% (note 10)1Upper limit frequency120HzDepend on actual condition2Lower limit frequency0Hz3Base frequency (n
6、ote 1)60Hz43 speed setting (Hi)60Hz53 speed setting (Mid)30Hz63 speed setting (Lo)10Hz7Acceleration time5sec/10sec (note 4)10108Deceleration time5sec/15sec (note 4)10109Electronic thermal active relayRated output current (note 5)Depend on ratingDepend on ratingStandard operation function10Frequency
7、of DC brake action3Hz11Time of DC brake action0.5sec12DC brake voltage6%13Start frequency0.5Hz14Suitable load selection (note 1)015JOG frequency5Hz16JOG acceleration & deceleration time0.5sec18High speed upper limit frequency120HzOver 60Hz Depend on actual condition19Base frequency voltage (note 1)9
8、99920Acceleration & deceleration guideline frequency60Hz21Acceleration & deceleration time unit.022Stall prevention action level150%23Double speed stall prevention action level (note 6)999924Multiple stages speed setting (4 speed)999925Multiple stages speed setting (5 speed)999926Multiple stages spe
9、ed setting (6 speed)999927Multiple stages speed setting (7 speed)999929Acceleration & deceleration curve030Recovery function selection031Avoidance frequency 1A999932Avoidance frequency 1B999933Avoidance frequency 2A999934Avoidance frequency 2B999935Avoidance frequency 3A999936Avoidance frequency 3B9
10、99937Run speed indication038Frequency at 5V (10V) input60Hz (note 2)39Frequency while 20Ma input60Hz (note 2)Depend on actual conditionOutput function41Frequency reach amplitude of action10%42Output frequency detection6Hz43Output frequency detection while reverse rotation99992nd function44Second acc
11、eleration & deceleration time5sec/10sec(note 4)45Second deceleration time999946Second torque compensation (note 1)999947Second 2V/F basal frequency (note 1)999948Second electronic thermal active relay9999Display function52Selection of operating device/PU main display data054FM end sub- function sele
12、ction155Frequency display guideline60Hz56Current display guidelineRated output currentRe-start57Restart empty run time999958Restart ascend run time1.0 secAddition function59Remote setting function selection0Action selection function60Shortest acceleration & deceleration mode061Guideline current99996
13、2Current guideline value while acceleration999963Current guideline value while deceleration999965Auto reset selection066Stall prevention action reduction start frequency (note 6)60Hz67Number of reset while occurrence of abnormality03368Waiting time for executing auto reset1sec69Clear of frequency of
14、 auto reset execution070Special recovery brake0%71Applicable motor072PWM frequency selection1227305V、010V selection01174Filter time constant18875Reset selection/PU remove detection/PU stop selection1477Parameter lock selection02278Reverse rotation prevention selection01179Run mode selection (note 6)
15、122Motor constant80Motor capacity999982Motor energizing current9999 (note 3)83Motor rated voltage200/400V84Motor rated frequency60HzDepend on actual conditionDepend on actual condition90Motor constant (R1) (note 6)999996Automatic harmonic setting /status (note 6)0Communication function117Office numb
16、er0118Communication speed192119Stop bit length1120With or without identical bit check2121Times for communication retry1122Interval of communication confirming time0123Waiting tine setting9999124With or without CR-LF selection1PID control128PID action selection0129PID proportion band100%130PID integr
17、ation time1sec131Range of upper limit9999132Range of lower limit9999133Target value of PID action while PU run0%134PID differentiation time9999Addition function145Parameter for PU04 Peripheral146Frequency command setting selection0Addition function150Output current detecting level150%0151Output curr
18、ent detecting time0152Zero current detecting level5.0%153Zero current detecting time0.5secAuxiliary function156Stall prevention action selection0Addition function160User parameter group read out selection0Monitor recover171Memory clear of actual run time0User function173User first group registration
19、0174User first group registration0175User second group registration0176User second group registration0Terminal function selection180RL terminal function selection0181RM terminal function selection1182RH terminal function selection2183MRS terminal function selection68190RUN terminal function selectio
20、n0191FU terminal function selection4192ABC terminal function selection999999Multiple stage speed selection232Multiple stages speed setting (8 speed)9999(Depend on actual condition)60233Multiple stages speed setting (9 speed)9999(Depend on actual condition)50234Multiple stages speed setting (10 speed
21、)9999(Depend on actual condition)40235Multiple stages speed setting (11 speed)9999(Depend on actual condition)30236Multiple stages speed setting (12 speed)9999237Multiple stages speed setting (13 speed)9999238Multiple stages speed setting (14 speed)9999239Multiple stages speed setting (15 speed)9999
22、Auxiliary function240Soft-PWM setting1244Cooling fan action selection0Auxiliary function245Motor rated slide differential9999246Slide differential correction response time0.5sec247Fixed output field slide differential correction selection9999249With/without ground network detection while starting (n
23、ote 9)0STOP selection250Stop selection9999Calibration function900FM terminal calibration902Frequency setting voltage bias0Hz903Frequency setting voltage gain60Hz904Frequency setting current bias0Hz905Frequency setting current gain60Hz922Built-in frequency setting VR bias0Hz923Built-in frequency sett
24、ing VR gain60Hz990Key tone control of operating deviceNote :1. These parameter setting will be ignored and void if selected under universal magnetic beam vector control mode.2. Calibration executed while ex-factory, the setting value of each inverter will be differing more or less to each other. The setting value will be slightly higher than 60Hz frequency setting.3. If the setting value exceeds 100Hz while using the operating device, t
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 医疗美容消费者心理与服务满意度提升策略分析报告
- 2025年城市快速路建设项目社会稳定风险评估与风险评估信息化建设报告
- 全球心血管创新药研发管线动态与2025年市场前景分析报告
- 2025年互联网医疗在线问诊质量评价与医疗服务市场拓展策略研究报告
- 2025年冰雪旅游项目投资可行性评估与区域旅游市场需求分析报告
- 2025年养老机构医疗资源整合与运营策略研究报告
- 新解读《GB-T 39028-2020纺织机械与附件 罗拉式梳理成网机 术语和定义》
- 2025年车身广告项目立项申请报告
- 2026年外研版高考英语一轮复习考点梳理选择性必修第四册Unit6 Space and beyon
- 2025年高中秋季入学军训工作方案
- 科技发展与团队效率的协同进步
- 血液透析室一次性医疗用品管理
- 餐(饮)具消毒及供应、配送服务方案投标文件
- 物业管理服务机构设置及运作流程
- 2024年-2025年全国环保产业职业技能竞赛(工业废水处理工)考试题库
- 四环素类抗菌药物儿科临床应用专家共识(2024年版)
- 心肺复苏术课件2024新版
- 公司工程施工与监管制度
- 2023-2024学年北京牛栏山一中高一分班考数学试题及答案
- 特立帕肽治疗骨质疏松性骨折中国专家共识(2024版)解读
- 2024米面油采购合同范本
评论
0/150
提交评论