1、pad 6435 release issue no.1 released on 05/16/01procedure of install pad vanguard 64351. database for creating x.25 link for pad ewsd v9 onward in cp113 or cp113c/*/* create i/o processors for lau */*/cmdfile;setcfopt:ackcfs=error,dancmd=exec,ackreq=pos;/criop:ioc=1,bioc=11,iop=ioplau-0,iopr=ioplau-
2、1,biocr=11,loadtp=100,ldprty=low;confiop:iop=ioplau-0,ost=mbl;conflau:lau=0,ost=mbl;/* x25 link for pvc dialog function via pad/crx25link:x25link=1,lau=0,chan=1,net=x25lc,prtcl=bx25,l1baud=b64000,l1dtt=dte,#l1if=v24,l1mca=1,l2dtt=dce,l2lam=initia,l2n2=10,l2n1=135,l3dtt=dce,l3t25=1500;(l1if=x21/v35 w
3、hen pad using x21/v35 dim module interface)/confx25link:x25link=1,ost=mbl;/confiop:iop=ioplau-0,ost=act;/conflau:lau=0,ost=act;/* local osi address and th25 application crosiadr:adrnam=osiloch,nsadr=48-0-02,net=x25lc;crappl:applid=th25,pronam=cp02,adrnam=osiloch; ( cp02 : cp processors name)/* remot
4、e osi-addresses for th25crosiadr:adrnam=osirth01,nsadr=48-0-50,net=x25lc,locadr=osiloch;crosiadr:adrnam=osirth02,nsadr=48-0-51,net=x25lc,locadr=osiloch;crosiadr:adrnam=osirth03,nsadr=48-0-52,net=x25lc,locadr=osiloch;crosiadr:adrnam=osirth04,nsadr=48-0-53,net=x25lc,locadr=osiloch;/* remote processors
5、 for th25crpro:pronam=th2501,protyp=omta; (ewsd-omt)crpro:pronam=th2502,protyp=omta;crpro:pronam=th2503,protyp=omta;crpro:pronam=th2504,protyp=omta; /* remote th25 applicationscrappl:applid=dial1,pronam=th2501,adrnam=osirth01,aut=1;crappl:applid=dial1,pronam=th2502,adrnam=osirth02,aut=1;crappl:appli
6、d=dial1,pronam=th2503,adrnam=osirth03,aut=1;crappl:applid=dial1,pronam=th2504,adrnam=osirth04,aut=1; ( applid=dial2,when processors used for alarm data output and traffic data output)/*pvc for linkscrx25pvc:pvcnam=thpvc001,adrnam=osirth01,x25link=1,chno=11,pcksz=128-128;crx25pvc:pvcnam=thpvc002,adrn
7、am=osirth02,x25link=1,chno=12,pcksz=128-128;crx25pvc:pvcnam=thpvc003,adrnam=osirth03,x25link=1,chno=13,pcksz=128-128;crx25pvc:pvcnam=thpvc004,adrnam=osirth04,x25link=1,chno=14,pcksz=128-128;/confx25link:x25link=1,ost=act;resetcfopt;endfile;2. upgrade pad fw (54p01a to 54p0fa)1). requirementa. cd ( m
8、otorola vanguard 6435/6455 ip 5.4p01a) which is delivered together with pad 6435. b. floppy disk (with three files - v54p0fa.exe ,54p0fao01.des and standard.mem ) which is provided by se_ts1;c. pc using your own notebook pc or using any desk pc with cd_rom.2).install configuration toolsa. insert cd(
9、motorola vanguard 6435/6455 ip 5.4p01a) into cd-rom;b. execute file e:installvgsetup;c. select directory c:motorola;d. select “next” until installation finished. 3).install upgrade filea. insert floppy disk to drive a;b. execute file a:v54p0fa.exe;c. select cd-rom drive e: ;d. select install directo
10、ry c:motorola;e. select “next” until installation finished;f.copy a:54p0fao01.des to c:motorolasfw_imgsv6400.4).upgrade pad fwa.execute file c:motorolasfw_imgsv640054p0fao01.des,vanguard software builder window will occurred;b.after input the corret licenses number(cd licenses) ,fill the options:rel
11、ease : 5.4.p0fa;product : vanguard 6400;memory size: 32m bytes;flash size: 4m bytes;image name : bisc;option number: 01;software licenses available: ip.c.click “create option” button, and wait a few minutes;d.when “do you want to load” window occur, selected yes;e.vanguard software loader window wil
12、l occur, fill options:drive: c: ;product: v6400 ;release: r54pp0fa;image name: 54p0fao01.zip;comm port: com1 or com2;speed: 115200.( you can change the speed by win nt control panel/ports )f.connect the pc com to pad port4 with cable 5, then click the “load”button. so the 540fa aps will load to the
13、pad. after click the buttonof “ok”, the upgrade working finished.3.configure pad database automaticallyif pads configuration is standard, you can upload the standard database from file a:standard.mem. else you must configure the pads database by hand. a. copy a:standard.mem c:motorolaconfigs/v6400up
14、loadb. execute file c:motorolavanguidecmem32.exe;c. vanguard configuration loader window will occur, fill options:drive: c: ;product: v6400;application: upload;d. select standard.mem as the configuration file and click “load” button,pad database will be configure automatically.4. setting pad paramet
15、er values by hand1). pad motorola 6435port1 -for x.25 link connection to ewsd iopscdp.-dim v.24 or dim x.21,v.35 also can be used -port 1,2 physical address must be set to dce location when pad directly connecte to iopscdp, when via modem it must be set to dte. -if only one x.25 link used the other
16、port can be used for connection terminal vt100 or omt, then the dim must be set to dce location. port3-5only port4 used to connect pc for modify pad parameter . port2,7,10,13 pad port connection omt or vt100 . evey port must haver232 dim chip inside for v24 protocal , under the dim chip where are 8
17、swith , switch1-5 set to “ on “ and switch6-8 set to “ off “ .front view of pad lcd display rear view of pad port13port10port7 543port2port1 power power switch cable3.) setting pad parameter valuslink pad with pc 5 port4 com16435 vt100 terminal connection cable form port4 to pc is supplied by motoro
18、la .connection the vt100 (or use vaguard terminal)to pad port4 and power on pad and pc,the vt100 terminal will show ok , type atds , then input password ( type enter)the main menu appears.a. node setupmenu 6: configuresubmenu 1: nodenode address1b. port setupsubmenu2: portport configuration 1port ad
19、dress1port typex25clock sourceint ( ext when x25 link via modem)clock speed64000link addressdtenumber of pvc c hannels5starting pvc channels number11number of svc channels0x.25 optionscauseport address1port configuration 2-13port address2port typepadconnection typedtrdata bits per character7device p
20、arityevenprofile nameewsd-omt or vt100 or defautc. pvc table setupmenu 6.3.2 : pvc setup tableentry number 1source x25-1(11)destinationpad-2entry number 2source x25-1(12)destinationpad-7entry number 3source x25-1(13)destinationpad-10entry number 4source x25-1(14)destinationpad-13d. profile table set
21、upmenu 6.10:pad profile tableentry number 1profile namedefautentry number 2profile nameewsd-omt#1 pad recall0#2 echo0#3 data forwarding character4+16#5 device flow control1#6 service control signals0#7 break signal operating0#13 line feed insertion after cr0#15 editing0#16 charater delete0#17 line d
22、elete0#18 line display0#19 editing type0#21 parity treatment3#106 network parity1#110 esc forwardind delay0entry number 3profile namevt100#3data forwarding character2+16+32#5device flow control1#6service control signals0#7break signal operating0#17line delete127#20echo mask16+32+128#21parity treatme
23、nt3#106network parity1e. bootmenu 7.5 node(cold) 3. cable list 1 or 8v24(dce)v24(dte)x21(dce)x21(dte)v35(dce)v35(dte)padiop:scdpx25m:laumm 1or8 6 or 7 3 2 4 5 tmnmm 2or9 6 or 7 13 11or 14 10mm 11/14 6 or 7 12cable code number supplied bylength 1s38228-z77-a150 (floor)bisc15m 2s38228-z76-a150 (floor)
24、bisc 15m 3v24-m-a15 motorola 15m 4x21-c-a05 motorola5m 5v24-c-a15motorola15m 6a/b x2 customer12km 7a/b customer8km 8s38228-z47-a150 (w/o floor)bisc15m 9s38228-z46-a150 (w/o floor)bisc 15m10 v35-c-a05motorola5m11 s38228-z49-a150 (floor)bisc15m12 v35-m-a15motorola15m13 x21-m-a15motorola15m14 s38228-z4
25、8-a150 (w/o floor)bisc15mcable 5 : v.24 db9f-db25m( rs-232c)dtedce 1 8cd 2 3rd 3 2td 4 20dtr 5 7sg 6 6dsr 7 4rts 8 5cts 9 22rifemalemalecable 3 : v.24 db25m-db25m crossover 1 1 2 3 3 2 4 8 5 14 6 20 7 7 8 4 14 5 15 18 17 24 18 15 20 6 22 25 24 17 25 22 16 21 21 16 male malecable 4 : x.21 db15f-db25m cable 13 : x.21 db15m-db25m 2 2 3 4 4 3 5 8 6 15 8 7 9 14 10 20 11 16 12 6 13 21femalemale ( cab
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 急性肺栓塞诊疗指南
- 《GB-T 38834.1-2020机器人 服务机器人性能规范及其试验方法 第1部分:轮式机器人运动》专题研究报告
- 2026年湖南电子科技职业学院单招职业适应性考试题库含答案详解
- 《正常人体功能》课件-蛋白质的生物合成
- 《python语言程序设计》课件-项目实战 塔吊智能螺母预警系统开发
- 运维人员培训服务合同
- 钟表行业智能手表软件工程师岗位招聘考试试卷及答案
- 2025年9月21日陕西渭南社工面试题及答案解析
- 工业园区管理委员会2025年度应急管理工作情况报告
- 2025年电力金具合作协议书
- 文冠果整形修剪课件
- 2025年下半年上海当代艺术博物馆公开招聘工作人员(第二批)参考笔试试题及答案解析
- 2026国家粮食和物资储备局垂直管理局事业单位招聘应届毕业生27人考试历年真题汇编附答案解析
- 癌性疼痛的中医治疗
- 大学生就业面试培训
- 2026年旅行社经营管理(旅行社管理)考题及答案
- 2026年北京第一次普通高中学业水平合格性考试化学仿真模拟卷01(考试版)
- 东北三省精准教学联盟2025年12月高三联考语文
- 物业服务协议转让合同
- 2024年江苏省普通高中学业水平测试小高考生物、地理、历史、政治试卷及答案(综合版)
- 8 泵站设备安装工程单元工程质量验收评定表及填表说明
评论
0/150
提交评论