无源交调测试技术_第1页
无源交调测试技术_第2页
无源交调测试技术_第3页
无源交调测试技术_第4页
无源交调测试技术_第5页
已阅读5页,还剩6页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、Passive IntermodulationMeasurement Techniques2May 1999IntroductionThrough interaction with engineers and technicians in many countries throughout theworld, Summitek Instruments has had the opportunity to discuss and evaluatemeasurement techniques as they apply to a wide variety of items. We have dis

2、cussedthe problem of IM with component manufacturers, infrastructure providers, sitemanagers and service providers. This perspective combined with the knowledgegained through the development and manufacture of our Passive IntermodulationAnalyzers, forms the basis of our approach to the measurement o

3、f passiveintermodulation, and the test capabilities built into our analyzers.Our findings suggest the following: Consistently manufacturing low IM items is extremely difficult to achieve in massquantities where the emphasis is on cost reduction Dynamic measurements should be performed on all PIM cri

4、tical devices Fixed frequency measurements may not be adequate due to the frequencydependent characteristics exhibited by many devices and subsystemsWhy Do We Care About Passive Intermodulation (PIM)?Passive IM is an increasing concern in the wireless community, because of thedebilitating affect it

5、can have on the performance of the telecommunications network.Passive IM is generated whenever more than one frequency encounters a non-linearelectrical junction or material. The resulting creation of undesired signals,mathematically related to the original frequencies, can result in decreased syste

6、mcapacity and/or degraded call quality.Reduced capacity and call quality at a cell site leads to reduced income for thewireless service providers. The economic loss is compounded when the affectedcustomer becomes frustrated and switches over to a competing provider.3May 1999Question: Is Passive IM A

7、 Design Issue, A Manufacturing Issue, or AMaintenance Issue?Answer: “All of the Above”.A good design is a necessary, but not a sufficient condition for successAt one time, many companies considered IM something that could be controlledsimply by following a few well-documented design rules. Avoid the

8、 use of ferrous metals. Minimize the number of contact junctions. Design all contact junctions such that they are precise and under sufficientpressure to maintain good contact. Solder or cold weld all junctions where possible. Avoid dissimilar metals in direct contact. Plate all surfaces to prevent

9、oxidation. Make certain plating is uniformly applied and of sufficient thickness.The bigger challenge is building itAlthough, the rules seem straightforward, manufacturing excellence is the key tosuccess. Minor deviations from the ideal process can create unacceptable levels ofPassive IM.Some of the

10、 real world deficiencies that occur: Poor alignment of parts. Inadequately torqued screws and fasteners. Bad solder joints. Insufficient or incomplete cleaning of parts prior to plating. Contaminated plating tanks. Plating material build-up. Using wrong materials Poor plating adhesion4May 1999Once y

11、ou have good designs and well-manufactured components, the next challengeis integration and system installation. Recall that all junctions are potential PIMgenerators. Therefore, every interconnect is a potential source of trouble. Joints thattest out fine in a benign environment can become problema

12、tic when mechanicallystressed (bending of cables, torsional loads on connector interfaces, over/undertorqued connectors).In summary, it is not a given that interconnecting components that meet their IMspecification assures a subsystem that also meets the IM specification. And then Mother Nature take

13、s over.The natural elements are the enemy of those portions of the network that are exposedto them. Wind-induced vibration daily temperature variations moisture in its various forms thermal loading by the sun air borne dirtEach of these works to break down and erode the quality of the components in

14、thenetwork, and ultimately the communication channel. The weakening of joints,separation of junctions, invasion of moisture, oxidation of materials, andcontamination by dirt and dust all give rise to passive intermodulation anddesensitization of the receiver.The result is a cell site performing belo

15、w its design potentialTest Methods Quantifying passive IM performanceGood communication quality requires maintaining an acceptable Carrier-to-Interference (C/I) ratio. Therefore, the goal is to keep I as low as possible. In theideal case, I would always be below the receiver noise floor. One source

16、ofundesired interference is passive intermodulation.A typical specification requires a passive IM level no greater than 110 dBm whentwo +43 dBm carriers are injected into the device under test, i.e., -153 dBc. To putthis into perspective, this is a ratio of 1:2,000,000,000,000,000, or the equivalent

17、 oftrying to measure the distance to the sun to an accuracy of one-tenth of a millimeter.5May 1999A commonly used approach to measuring passive IM is to inject two fixed frequencyCW tones of 20 watts per tone into the device under test and measure the IM powerlevels generated. This test scenario is

18、consistent with that proposed by theinternational standards committee tasked with defining test methods for themeasurement of passive IM (IEC TC46 WG6).To realize the necessary test setup, the classic approach has been to rack and stacktwo synthesizers feeding two high power amplifiers that connect

19、to an array of RFcomponents, which combine, filter and duplex the signals, and then route the signal ofinterest through a low noise amplifier to a spectrum analyzer for detection anddisplay. A power meter is used to set the proper transmit powers and then readjust ona periodic basis to compensate fo

20、r drift.The rack-and-stack approach to building a passive IM test bench is clearly a difficultprocess. Furthermore, because there are so many discrete instruments, componentsand interconnecting cables, the measurement results are sometimes difficult to repeat,and the setups are often unstable and su

21、sceptible to damage. As if that werentenough to discourage all but the stouthearted, the measurement is time-consuming,and as we are beginning to realize, the results can be inconclusive and misleading.The Summitek Instruments WayWith an understanding of how passive IM testing was performed (and the

22、 associateddeficiencies), Summitek set forth the following design goals: Build a test instrument that produces high quality, repeatable measurements. Make the instrument easy to set up and use. Advance the state-of-the-art by providing new and useful test tools. Bring standardization to this difficu

23、lt measurement in order to establish a clearbasis of performance comparison. Stay current with emerging technology trends and test standards. Listen to the customer and incorporate their recommendations as appropriateto provide the most comprehensive and easy to use test instrument possible.This led

24、 to the three significant design features incorporated into Summiteks PassiveIM Analyzers:1. A highly integrated design: Minimize the number of external components bypackaging all of the RF components in a single enclosure. This results inimproved reliability, stability and repeatability.6May 1999Su

25、mmitek analyzers make it possible to: Measure multiple IM products simultaneously. Measure and record transient events such as PIM burst and changing IM due tomechanical and environmental stress. Measure swept frequency intermodulation characteristics to verify performanceover the entire specified f

26、requency range.3. Innovative new test capabilities: The resulting instrument is easy to use, time-efficientand thorough, so that it is practical to make the measurements necessary to assureproduct quality and network integrity.Revealing RealityMost measurements are made with a single pair of carrier

27、 frequencies, usually set atthe transmit band edges for the wireless standard you were testing.For example, consider the measurement of a device used in a PCS1900 Bandnetwork. Typically, this test is performed by setting Carrier 1 to 1930 MHz andCarrier 2 to 1990 MHz. (Note: There are some PIM test

28、setups that, due to theirdesign, must use one carrier set to a frequency in the receive band while the othercarrier is set to a frequency in the transmit band. The validity of this approach open todebate.)After the transmit frequencies and powers are established and the spectrum analyzerconfigured t

29、o measure the IM response, the test is initiated. During the measurement,care is often taken not to disturb the device under test or the test setup in caseinstabilities might produce a data a spike at the precise moment the spectrum analyzerhappens to be sweeping past the IM frequency.Experience sug

30、gests that this approach to measuring PIM is much too limited andleaves too many potential problems hidden.Dynamic MeasurementsDespite the best efforts to design and manufacture products that are stable regardlessof their environment, the passive IM response of components and subsystems canvary dram

31、atically when subjected to stress. In a dynamic measurement, IMperformance is monitored during the application of an appropriate stimulus.The issue of dynamic measurements has been given a great deal of attention withregard to cable assemblies. The concern has to do with the vulnerability of theconn

32、ector/cable interface as well as IM created in the cable (by micro-cracks in solid7May 1999measuring the IM as the cable is flexed and/or a bending moment is applied at theconnector/cable interface.Two measurementsroutinelyperformed bySummitek on allPIM criticalcomponents usedin our analyzersare the

33、 “tap” testand the bendingmoment test.In our view, all components on the basestation transmit side of thewireless network should be subjected to this scrutiny. Twomeasurements routinely performed by Summitek on all PIMcritical components used in our analyzers are the “tap” test and thebending moment

34、 test. The tap test is simply a matter of tapping thedevice and watching the IM response. For example, tapping thetuning screws on filters frequently generates high levels of passiveIM. After the tapping is stopped, the IM sometimes returns to itslow IM condition and sometimes it remains high. The t

35、ap test hasbeen demonstrated to be highly useful in screening devices andcables that will fail at some future (and inconvenient) time.This is illustrated in the following example. In this case, we usedthe Strip Chart Mode of the Summitek analyzer to record the IM response over time.The device under

36、test is a PCS1900 bandpass filter. What we are observing is thechanging IM due to tapping. Later testing also showed this device to have much-degraded IM performance with temperature changes.-70dBm at 2 x 20W Tones-90-110-130010203040Time, SecondsFigure 1: Dynamic IM Measurement8May 1999connector on

37、 the device under test. If the connector is not adequately attached to thebody of the component, or if the launching mechanism within the device is not solid,IM will be generated.Swept Frequency MeasurementsUntil now, the accepted method for measuring passive IM was to set the carrier totwo fixed fr

38、equencies, usually, but not always in the transmit band, and measure theIM generated. What has been discovered is that on many devices, this is not adequate,because these devices exhibit IM characteristics that vary as a function of frequency.Summitek Instruments Passive IM Analyzers make this measu

39、rement at multiplefrequencies practical and easy.An example clearly demonstrates the virtue of the swept frequency IM measurement.In this case, a PCS1900 band duplexer with a bad connector is measured. It should benoted that the connector damage was caused by over-torquing the connector and isundete

40、cted by visual inspection and swept return loss measurements. The comparisonbetween the “good” and the “bad” duplexer return loss is shown in the followingfigure.0.00-5.00-10.00-15.00-20.00-25.00-30.00-35.00-40.00“bad” duplexer has a severely degraded IM as the tranmsit carriers are moved fromthe band edges. B

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论