1、External Liquid Level Gauge 01000373 13L129-61 Manual bookSHAANXI SHENGKE ELECTRONIC TECHNOLOGY CO.L1. Product overviewExternal liquid level gauge using the advanced signal processing technology, avoid the influence of the thick wall of tank, realize the non-contact detection between liquid inside a
2、nd tank wall. The probe is installed under the tank which to be detected, no need to drill on the tank wall, its easy to install. The installation and debugging can be done online, no effect on production. SK external liquid level indicator realize the accurately detect of the flammable, explosive a
3、nd poisonous liquid (strong acid and strong base) level and kinds of pure liquid level, and no special requirement for the tank material and liquid material, with flame-proof design, meet the explosion-proof requirements, can be widely used.Sonar external liquid level gauge produced according the en
4、terprises standard Q/SK 001-2013.2 Work PrincipleExternal liquid indicator uses the principle of sonar ranging collecting the sonar signal by the special probe fixed outer wall of the tank. Taking the proprietary High-Speed sonar wave processing technology as the core, then by the SHAN XI SKS P
5、roprietary Method to calculate the level Data and transmitting data to the control center. Indicator can send the data to the control center by the (4-20)mA analog signal, HART, RS-485, Ethernet connector, meanwhile by Wi-Fi,Bluetooth,HART,RS-485, infrared, Ethernet debugging online.As picture 1 sho
6、wing, When Measuring, the sonar wave signal send from the probe, Signal reflected when meet the liquid level, the probe detects echo signal. Echo signal analyzed by proprietary algorithm to calculate the time (t),.Device system will calculate the liquid level data according to the formula.H=v*t*a/2H
7、: liquid level heighta: Correction coefficientv: The speed of the sonar wave propagation in liquidt:The time from the sonar wave returnPicture 13 Performance IndexExternal lever controllerTwo-wire typeFour-wire typeMeasuring range(0.23)m,(0.35)m,(0.410)m,(0.515)m,(0.620)m,(0.730)m,(0.850)mPreview re
8、solution1mmRepeatability in short time1mmMeasuring error±1FS,±2FSTransfer volume±100mSignal output(420 )mA, HART,MAX 500(420) mA, HART,MAX 1000Power <80mw10wCommunicationRS-485,IR,HART,RS-485.IR,HAT,Modbus,Wi-Fi,Bluetooth,EtherneRelay alarm outputAC 250V 5A,DC 30V 5AEnvironment tem
9、perature in using lever gauge-20+70,-40+70Environment temperature in using probe-50+100,60330Ambient humidity(0100%)RHExplosion-proof signExd II CT6,Intrinsic safetyEnclosure protection gradeIP65,IP67Liquid level indication6 128*64 liquid crystal displayDead zoneIt will show “Dead” when liquid level
10、 in dead zone, the output will be 4mA in signalPower supplyDC 24VDC 24V,AC 220VElectrical interface M20*1.5The cable length from probe to main engine5m,10m,15m,20m,25m,30mWeight of mainframe2.9KGSize of mainframe217mm(length)*160mm(width)*185mm(height)The diameter of the base hole in mainframe6mm4 A
11、pplication Range4.1 Liquid Purity:Liquid without much sediment, crystal, auto polymer, suspended solid, some bubbles.4.2 Liquid viscosity:Dynamic viscosity of liquid medium30mPa.sNote: The viscosity always reducing with the temperatures upping, so please take about the liquid temperature. 4.3Tank:Ta
12、nk material:need to use the hard steel, the material have to transfer the information well. Such as carbon steel, stainless steel, glass fiber reinforced plastics, epoxy resins, ceramic, 16MnR, 304,316, FRP, hard rubber. The tank walls inside and outside should even. If the tank wall have more layer
13、s materials, the space between layers should touching closely, without babbles and air. For Examples:Sulfide hard rubber lining, lining of epoxy resin, stainless steel lining, titanium lining.Tank thickness:(270)mm5 Installation5.1 Main body InstallationThere are four holes in the main body bottom,
14、you can fix the main body part on the anywhere by bolts, about the installation place you can choose it according the occasions.Please use the protection box in the low temperature place, and please install it in the shade of the high temperature place, avoiding impact the gauge working temperature.
15、The Gauges screen cannot be under the sun in long time.5.2 Probes InstallationFor the steel tank,use the magnet chuck adsorb it at the bottom of the tank directly. Like the picture 2.For the other non-magnetic materials, please use adhesive or fixed it on the support, such as the glass tank wall and
16、 stainless steel wall. Like the picture 2.Picture 25.3 Measuring Probe Installation Place ChooseProbe point should correspond with the liquid level in a straight line.There are no obstructions above the probe.The probe installation place should away from the input hole in the bottom of the tank and
17、the upper input holes, avoid the liquid turbulent flow effect on the measurement. The probe installation place should Higher than the liquid outlet hole, in order to avoid long-term deposit dirt of the tank bottom effect on the measurement .If not, please clear the dirt regularly.The installation ro
18、und area on the tank wall should more than100mm,The surface roughness should reach 1.6, the inclination should be less than 3 °5.4 Measuring Probe and Main body installation diagramPicture 35.5 Calibration Probe Installation DiagramThe calibration probe installation way is same as the measuring
19、 probe installation way. Four situation.Tube CalibrationPut the calibration probe on the input tube and output tube, when the tube full of the liquids, the sonar speed can be measured by calibration probe. Like the picture 2-D. Picture 2-Dl Vertical tankl Put the calibration probe on the side wall o
20、f the tank, detect the Liquid speed by the calibration probe. Like the picture 2-E.Picture 2-El Spherical tank diameter calibration Put the calibration probe above the vertical tank diameter, when the liquid over the diameter, it can detect the liquid sonar speed by calibration probe. Like the pictu
21、re 2-f.Picture 2-Fl Calibration tube wayl Please put the calibration probe on the side wall of the spherical tank, when the liquid over the calibration 。 Picture 2-G 6 Electrical Connection6.1 Liquid Level Gauge ElectricityMaxNormalMin(V)direct voltage302418transient(power on)workingelectricity(A)0.
22、50.25power功率(W)10 6.2 Gauge Terminal Blocks InstructionmarkconnectionDC24V24V direct electricity 420mA HARTCALcalibration probeMEAmain probeRS-485RS-485 Communication Two-wire liquid level terminal diagram markconnectiondefineCAL+Calibration probeSignal positive-Signal negativeMEA+Measuring probeSig
23、nal positive-Signal negativeIO-4-20mA(HART)Current output negative+Current output positiveRS-485ARS-485485+B485-AlM2NORelay alarm output 2NO PointNCNC PointALM1NORelay alarm output 1NO PointNCNC Point24V+DC24V electricitypositive-negative Four wire liquid level terminal diagram7 External Sizes 7.1 M
24、ain Body (picture 7) Dimensions: mmNet weight: 3.4kg Picture 77.2Probe and Chuck(picture 8):Picture 8The Gauge use explosion-proof probes, the shells material is hard alloy steel, Nitrile butadiene rubber seal, protection grade IP65, explosion-proof marks is Exd CT6.8 SpecificationSK-WYExplosion typ
25、eA:Normal B ExdIICT6 C EExiWire Connection typeL: two-wire S:four-wireTank typeQ:spherical tank W:horizontal tank L:Vertical tankMeasuring range3.5.1.15.20.30.50(M)Measuring AccuracyG:high accuracy D:low accuracyJ(N)Relay output alarm module and output numberHHartMModbusWWI-FI BBluetoothRInfrared CT
26、he magnetic pen debugging moduleEEthemet For example: SK-WY-BS5G-HMWBRCE is the Liquid level gauge with explosion-proof and four wire type. Measuring range is 5M.with Hart, Modbus. Wi-fi, Bluetooth, infrared, magnetic pen, ethemet.9 Operation1 Open the box to check if the gauge shell is and the glas
27、s screen is ok.2 Install the probe.(picture 5.2);3 Connect the wire.(picture 6.2);4 Check the gauge bodys front part and back part carefully, if the little bolts are loose, please to tight it.5 Power on, the gauge can checked by itself, and enter the measuring display status. You will see the liquid
28、 level height value from the display screen. Note: The shall of the gauge have to reliable grounding.10 Maintenance and Repair1 Keep the gauge clean, Guard against water, damp, corrosion and collision.2 Outside installation should protect the gauge avoiding direct sunlight, away from the heat, if th
29、e environment temperature more than the set temperature, please take any protection measures to cooling it.3 If the environment lower then set temperature please protect the gauge with box or other ways. And please keep the gauge dry.4 The gauge and the probes should be checked regularly.11 Note for
30、 explosion-proof liquid level gauges use1 If the gauge need branch or graft, must need the explosion-proof connection box(with EX Mark and explosion-proof certificate,)if there is extra terminal, must seal the terminal with the sealing accessories in agreement with the explosion proof connecting box, assuring the explosion-proof function. 2 The Gauge working environment temperature should be within -2070,when the liquid temperature impact the gauge, please take any protective action.3 The gauges installation shoul
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 广安2025年上半年广安市邻水县“小平故里英才”引进急需紧缺专业人才笔试历年参考题库附带答案详解
- 北京2025年民族团结杂志社公开招聘9人笔试历年参考题库附带答案详解
- 2025福建南平市中昱设计咨询有限公司招聘27人笔试参考题库附带答案详解
- 山西林业职业技术学院《中级财务管理》2023-2024学年第二学期期末试卷
- 厦门城市职业学院《EP系统原理与应用》2023-2024学年第二学期期末试卷
- 山东外事职业大学《电视画面编辑》2023-2024学年第二学期期末试卷
- 贵州航天职业技术学院《会计英语》2023-2024学年第二学期期末试卷
- 赤峰应用技术职业学院《食品原料安全控制(实验)》2023-2024学年第二学期期末试卷
- 哈尔滨信息工程学院《信息系统研究》2023-2024学年第二学期期末试卷
- 柳州铁道职业技术学院《铸造工艺学》2023-2024学年第二学期期末试卷
- 库管员笔试题及答案
- 自考《03203外科护理学》考试题库大全-下(多选题)
- 精装房营销策略研究-全面剖析
- 融资融券基本管理制度
- 公路工程质量试题及答案
- 中央贸促会面试题及答案
- 产业链购销合同
- 昇腾DeepSeek解决方案
- 出口美国合同范本
- 2025-2030中国香紫苏醇市场发展形势及未来投资风险预警研究报告
- 2024年市场营销师品牌宣传技巧试题及答案
评论
0/150
提交评论