1、附附录录二二 湿湿负负荷荷计计算算表表 类型房间人体散湿量敞开水表面散湿量食物散湿量n(人)g(g/h)kg/sA( )W( )kg/sn(人)kg/s1012 0.93184 0.00009500.44 0.0000000.93201022 0.93184 0.00009500.44 0.0000000.93201032 0.93184 0.00009500.44 0.0000000.93201042 0.93184 0.00009500.44 0.0000000.93201052 0.93184 0.00009500.44 0.0000000.93201062 0.93184 0.0000

2、9500.44 0.0000000.93201071 0.93184 0.00004800.44 0.0000000.93201080 0.93184 0.00000000.44 0.0000000.93201092 0.93184 0.00009500.44 0.0000000.93201108 0.93109 0.00022500.44 0.0000000.93801111 0.93184 0.00004800.44 0.0000000.93201122 0.93184 0.00009500.44 0.0000000.93101132 0.93184 0.00009500.44 0.000

3、0000.932011430 0.89184 0.00136600.44 0.0000000.89500.000148331156 0.93240 0.00037220.44 0.0002450.93601168 0.89184 0.00036400.44 0.0000000.8980.000023731178 0.89184 0.00036400.44 0.0000000.8980.000023731181 0.93184 0.00004800.44 0.0000000.93101198 0.93109 0.00022500.44 0.0000000.9360kg/h总散湿量kg/s0.00

4、00950.0000950.0000950.0000950.0000950.0000950.0000480.0000000.0000950.0002250.0000480.0000950.0000950.0015140.0006170.0003880.0003880.0000480.000225附附录录二二 湿湿负负荷荷计计算算表表附附表表三三 新新风风量量计计算算表表房间人数人均新风量m3/h风量m3/h正压5Pa(按换气次数算)总送风量计算换气次数房间面积房间体积风量m3/h房间冷负荷kw房间湿负荷*10-6(kg/s)热湿比kJ/kg送风状态点焓值kJ/kg101办公室230600.51

5、9.863.3631.681.00960.61665048.9102办公室230600.519.863.3631.680.92660.61528148.6103办公室230600.519.863.3631.680.92660.61528148.6104办公室230600.519.863.3631.680.92660.61528148.6105办公室230600.519.863.3631.680.92660.61528148.6106办公室230600.519.863.3631.680.94960.61566048.6107办公室130300.58.2526.413.20.59530.31963

6、748.9108办公室230600.511.55 36.9618.480.42660.67030109办公室230600.519.863.3631.681.35160.62229449.1110储藏室130300.515.96 51.07 25.5360.39530.31303647.5111门厅230600.549.5158.479.21.95860.63231049.7112值班室130300.58.8228.22 14.1121.24830.34118848.3113办公室130300.58.8228.22 14.1121.40430.34633750.0114餐厅503015000.7

7、104.94 335.8 235.079.3121515.1614648.9115值班室230600.510.834.5617.280.62860.61036348.7116门厅230600.576.16 243.7 121.866.85460.611310249.4117餐厅6301800.519.863.3631.680.999181.8549549.5118餐厅6301800.519.863.3631.680.999181.8549549.7119厨房5301500.539.6126.763.362.179225.8965050.1120办公室230600.512.640.3220.16

8、2.0160.633168注:114至117房间湿量太大,风机盘管的除湿能力有限,须在这些房间内加一除湿器,以减少房间湿负荷,风机盘管负担40的湿负荷。总送风量10m3/h新风量m3/h新风量kg/h新风比m总送风量kg/h382.3631.866072.019%340.1628.356072.021%340.1628.356072.021%340.1628.356072.021%340.1628.356072.021%348.6129.056072.021%161.4313.453238.024%522.9743.586072.014%130.4610.873036.028%810.2167

9、.527995.012%444.8337.073744.510%601.7150.145060.210%3528.76294.0615001800.051%233.0719.426072.031%2741.60228.47228274.210%404.0933.67180216.053%413.3834.45180216.052%945.1178.76150180.019%附附表表三三 新新风风量量计计算算表表总送风量计算注:114至117房间湿量太大,风机盘管的除湿能力有限,须在这些房间内加一除湿器,以减少房间湿负荷,风机盘管负担40的湿负荷。附附录录四四 风风机机盘盘管管的的计计算算功能房

10、间总送风量kg/h总送风量m3/h新风量kg/h风机盘管处理风量kg/h送风状态点焓值kJ/kg风机盘管出口空气焓值kJ/kg风机盘管负担冷量kw风机盘管制冷量kw101办公室382.36318.6372.0310.3648.946.701.0091.211102办公室340.16283.4772.0268.1648.645.970.9261.111103办公室340.16283.4772.0268.1648.645.970.9261.111104办公室340.16283.4772.0268.1648.645.970.9261.111105办公室340.16283.4772.0268.1648

11、.645.970.9261.111106办公室348.61290.5172.0276.6148.646.050.9491.139107办公室161.43134.5338.0123.4248.945.970.4260.5112108办公室109办公室522.97435.8172.0450.9749.147.621.3381.606110门厅130.46108.7236.094.4647.543.350.3920.471111值班室810.21675.1795.0715.1749.748.541.9382.326112办公室444.83370.6944.5400.3548.347.181.2371

12、.484113办公室601.71501.4360.2541.5450.049.071.3891.667114餐厅3528.762940.631800.01728.7648.939.019.26411.117115厨房233.07194.2372.0161.0748.744.360.6240.748116餐厅2741.602284.67274.22467.4449.448.406.7858.143117餐厅404.09336.74216.0188.0949.539.280.9941.193118值班室413.38344.48216.0197.3849.740.180.9941.192119门厅9

13、45.11787.59180.0765.1150.148.152.1582.589合合计计3535.8706新风机组负担冷量kw风机盘管选型风机盘管数量/台0.678FP-51WA-Y-G3010.678FP-51WA-Y-G3110.678FP-51WA-Y-G3210.678FP-51WA-Y-G3310.678FP-51WA-Y-G3410.678FP-51WA-Y-G3510.358FP-34WA-Y-G3010.678FP-51WA-Y-G3010.339FP-51WA-Y-G3020.895FP-34WA-Y-G3010.419FP-51WA-Y-G3010.567FP-51WA-

14、Y-G30116.950FP-51WA-Y-G3030.678FP-51WA-Y-G3022.582FP-102WA-Y-G3012.034FP-102WA-Y-G3012.034FP-34WA-Y-G3011.695FP-102WA-Y-G30233.29611附附录录四四 风风机机盘盘管管的的计计算算附附录录5 5 室室内内气气流流组组织织计计算算房间编号总送风量kg/h回风量kg/h送风温差送风口空调面积散流器/个单个送风量m/s选择尺寸*假定颈部风速m/s颈部实际风速m/s出口面积出口风速m/s101办公室521.43449.437.23.3*6.010.12180*1804.53.7

15、30.0294.14102-106办公室462.12390.127.73.3*6.010.11180*1804.53.300.0293.67107、108办公室139.4586.237.24.2*6.010.03120*1203.02.240.0132.49109办公室555.10483.107.53.8*6.010.13180*1803.53.970.0294.41110门厅839.56551.5688.4*6.620.10180*1803.53.000.0293.33111值班室384.83346.3472.2*4.210.09150*1504.03.960.0204.40112办公室41

16、2.40340.407.82.2*4.210.10150*1503.54.240.0204.71113办公室838.71754.8476.6*2.210.19200*2003.04.850.0365.39114餐厅3384.762304.767.28.4*13.230.26250*2504.54.180.0564.64115厨房1285.981069.987.46*6.620.15200*2004.03.720.0364.13116餐厅1036.00748.007.13.3*610.24250*2504.03.840.0564.26117餐厅1119.64831.647.13.3*610.26

17、250*2504.04.150.0564.61118值班室370.76333.6873.6*310.09150*1503.53.810.0204.24119门厅2072.391784.3977.8*1020.24240*2404.04.160.0524.63备注:散流器为FK-10型方形散流器;回风口为FK-14型自垂式双层百叶式风口。回风口射程m室内平均风速m/s实际风速m/s选择尺寸*回风口个数/个回风口风速m/s1.910.1660.20250*20012.651.680.150.18250*16012.880.720.070.09120*16011.322.040.200.24250*20012.851.520.130.15250*20013.251.680.170.202

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论