版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、层压板厚配比规定表正式版芯 板厚度有:0.1、0.2含铜不含铜两种。0.3、0.4、0.5、0.6、0.8、1.0、1.2 含铜,铜厚为 17.5 微米。半固化片:型号1080、理论厚度0.07mm、两张为0.13mm ;型号2116、理论厚度0.11mm ;型号7628厚度0.175mm。一般内芯板铜厚度18微米、外层30-40微米介电常数:4.5一般蚀刻补偿1.5mil板厚配比规定表多层板板厚配比规定四层板(1)板厚内层芯板厚(含铜)半固化片配比0.40.20X11080 乂0.60.30X12116 乂0.70.30X11080X40.80.5X12116 乂1.00.4X11080X2
2、7628 X1.20.60X17628X21080 X1.51.0X17628X21080 X1.61.0X17628X21080 X1.81.2X17628X21080 X2.01.6X11080X42.21.6X17628X21080 X2.52.0X12116X21080 >23.02.5X12116X21080 >2三层板示例:板厚1.6毫米(1)板厚1.6毫米(2)0.6mm CORE2116 (0.11mm)去仁7628(0.175mm)2116(0.11mm)>1.6板厚0.6mm CORE四层板示例:(1)板厚0.8mm0.8板厚(2) 板厚 1.0mm1 C
3、U 铜、 1080(0.07mm)7628(0.仃5mm)2 I0.5mm CORE V 1.0 板厚3 7628(0.仃5mm) 1080(0.07mm)4 CU铜丿(3) 板厚 1.6mmCU铜 2116 (0.11mm)7628(0.175mm)1.0mm CORE1.6板厚7628 (0.175mm)2116 (0.11mm)CU铜(4)板厚 2 . 0 mm1 CU 铜2116 (0.11mm)7628m)2116 (0.11mm)2 1.2mm| CORE 2.0 板厚32116 (0.11mm)7628(0.仃5mm)2116 (0.11mm)CU铜六层板板厚内层芯板厚(含铜)半
4、固化片配比0.80.2021080X41.00.25 >2108001.20.30>21080>42116>21.50.40 >22116>21080X41.60.40>27628 >1080X41.80.60 >22116>21080X42.00.60 >27628 >1080X42.20.80 >22116>21080X42.50.80 >27628 > 1080X52.71.0>27628 >1080X43.01.2>22116>21080X43.21.2>276
5、28 >1080X43.61.2>27628 X1080X44.01.6>27628 >1080X4(5)盲孔板 12盲3-4盲1 21080 (0.07mm)7628(0 175mm)1080(0.07mm)30 . 5 mm CORE4 0 . 5 mm CORE =7628 (0.175mm)1.6 板厚JCU铜CU铜7628(0.175mm)CU铜六层叠层结构示例:(1) 板厚1 . 0 mm 110802116232116211643 2116 10806(2)板厚的1 . 6 mm (0. 3 mm板芯)1 1080(0 07mm)1080(0.07mm)2
6、 0.3mm CORE31080(0 07mm)7628(0.175mm)1.6 板厚1080(0 07mm)40.3mmCORE51080(0.07mm)7628(0.175mm)1080(0.07mm)6(3)板厚1 . 6 mm (0.5mm 板芯)1 1080(0.07mm)2 32116 (0.11mm)1.6 板厚40.5mm CORE52116 (0.11mm)1080(0.07mm)6 CU铜2116(0.11mm)0.5mm CORE2116(0.11mm)CU铜丿(4) 板厚 2.0mm(0.6 板芯)1 CU 铜1080(0.07mm)2116 (0.11mm)1080(
7、0.07mm)2 0.6mm CORE31080(0.07mm)2116 (0.11mm)2.0 板厚1080(0.07mm)3 0.6mm CORE51080(0.07mm)2116 (0.11mm)1080(0.07mm)CU铜板厚2.0mm(0.5板芯)1080(0.07mm)1080(0.07mm)231080(0.07mm)7628(0.175mm)2.0板厚1080(0.07mm)40.5mmCORE51080(0.07mm)7628(0.175mm)1080(0.07mm)160.5mm CORE7628(0.175mm)CU铜盲孔1.6板厚 (1-2盲5-6盲)0.3mm CO
8、RE、2116(0.11mm)1080(0.07mm)2116 (0.11mm)3 0.3mml CORE1 6 板厚42116 (0.11mm)1080(0.07mm)2116 (0.11mm)4 0.3mm CORE6八层板板厚内层芯板厚(含铜)半固化片配比1.00.10X31080X81.20.10X37628 X1080>61.50.20X37628 X1080>61.60.20X37628 X1080>61.80.30X37628 >41080X42.00.40X31080X102.20.40X37628 X1080X82.50.50X37628 >41
9、080X43.00.60X37628 >41080 >63.00.80X31080 >83.20.60X37628 >41080X103.60.80X7628 >41080 >64.01.0>67628 >41080X4八层叠层结构示例:板厚1.6mm1 1080(0.07mm)1080(0.07mm)2 3 2116 (0.11mm)40.3mm CORE1.6 板厚52116 (0.11mm)2116 (0.11mm)5 0.3mm CORE71080 (0.07mm)1080(0.07mm)0.3mm CORE2116(0.11mm)CU铜
10、6 (2)板厚 2.0mm1 1080(0.07mm)1080(0.07mm)2 32116 (0.11mm)40.3mm CORE1.6 板厚52116 (0.11mm)2116 (0.11mm)6 0.3mm CORE71080 (0.07mm)1080(0.07mm)0.3mm CORE2116(0.11mm)CU铜7 十层板板厚内层芯板厚(含铜)半固化片配比1.50.20 X2116X 51.60.20 X2116X 61.80.20 X2116X 72.00.30X1080X102.20.30X7628 乂 1080X32.50.30X7628X41080X53.00.50X7628
11、 乂 1080X33.20.50X7628X41080X53.60.60 X7628X41080X54.00.60 X7628X51080X45.00.80X7628X51080X0十层叠层结构示例:(1)板厚 1.6mm1080 (0.07mm)1080 (0.07mm)1080 (0.07mm)1080(0.07mm)1080 (0.07mm)1080 (0.07mm)1080 (0.07mm)1080(0.07mm)0.2mm CORECU铜10801080CU铜(0.07mm)(0.07mm)> 1.6mm板厚2.0mm(0.07mm)(0.11mm)(0.07 mm)(0.11
12、mm)(0.11mm)(0.11mm)2.0mm(0.11mm)(0.11mm)(0.11mm)(0.07mm)(0.11mm)(0.07mm)CU铜0.2mm CORE0.2mm CORE0.2mm CORE0.2mm CORECU铜(2)11080211610802321162116452116211667211621168910802116108010十二层板(5)多层板叠板原则板厚内层芯板厚(含铜)半固化片配比1.60.15X51080X121.80.15X51080X122.00.15X51080X27628 >22.20.2X57628 X1080X102.50.2X5762
13、8 X1080X123.00.3X7628X41080 X3.20.3X57628X51080X33.60.45X57628X41080XS4.00.45X57628X51080XS5.00.60X57628X51080X121、客户要求原则:根究料的偏差,配出最接近客户要求值,有阻抗要求的,严格按阻抗推理数据配料。2、对称原则:芯板、半固化片必须对称叠放。3、填胶量:根据剩余的线路图形面积,铜的厚度考虑需多少体积的胶用作填充使用。铜箔在70微米以上的要考虑用含胶量高的如:10804、负公差原则:所有叠板理论厚度要比成品要求的厚度小大约在负0.1毫米。特殊要求板厚、介质层厚度的除外。5、盲埋孔
14、填胶:根据填充的体积,选择含胶量高的半固化片。6、7628型号半固化片不做外层:不要单独放在表层铜箔下。混凝土强度等级规范规定与设计使用表(原创)CAD-CAM 提交日期: | 分类: | 访问量:Google混凝土强度等级规范规定与设计使用表(原创)更多相关内容请访问"CAD家园论坛",获取完整满意的答案!混凝土强度等级规范规定与设计使用表、, 、-前言实际工作中广大设计人员往往忽略了混凝土强度等级的规定,出现了把所有垫层定为C15或更高:况,造成了不必要的浪费或设计了很多肥梁胖柱,本人详细查阅了有关规范并整理如下:第一章 混凝土结构设计规范 GB 5001 0-2002
15、中有关规定第条钢筋混凝土结构的混凝土强度等级不应低于 C15当采用HRB335级钢筋时,混凝土强 级钢筋以及承受重复荷载的构件 ,混凝土强度等级不得低于 C20。 预应力混凝土结构的混凝土强度 处理钢筋作预应力钢筋时,混凝土强度等级不宜低于C40。 注:当采用山砂混凝土及高炉矿渣混条文说明:基础垫层混凝土强度等级可采用 C10。第 4.1.3 条 混凝土轴心抗压,轴心抗拉强度标准值 fck,ftk 应 按表 4.1.3 采用。强度种类混凝土强度等级C15C20C25C30C35C40C45C50C55C60C65C70C75C80第 4.1.4 条 混凝土轴心抗压,轴心抗拉强度设计值 fc,f
16、t 应按 表 4.1.4 采用。强度种类混凝土强度等级C15C20C25C30C35C40C45C50C55C60C65C70C75C80注:1计算现浇钢筋混凝土轴心受压及偏心受压构件时,如截面的长边或直径小于300mm则表中混凝量(如混凝土成型,截面和轴线尺寸等 ) 确有保证时,可 不受此限制; 2 离心混凝土的强度设计值 第条 混凝土受压或受拉的弹性模量 Ec应按表采用。混凝土强度等级 C15C20C25C30C35C40C45C50C55C60C65C70C75C80第 7.1.3 条 受弯构件、偏心受力构件正截面受压区混凝土的应力图形可简化为等效的矩形应力图 矩形应力图的受压区高度x可
17、取等于按截面应变保持平面的假定所确定的中和轴高度乘以系数B0.8,当混凝土强度等级为C80时,B1取为0.74,其间接线性内插法确定。矩形应力图的应力值取为混凝土轴心抗压强度设计值fc乘以系数al。当混凝土强度等级不超过C80时,al取为0.94,其间按线性内插法确定。第 10.5.1 条 当构件截面的长边(长度)大于其短边(厚度)的 4倍时,宜按墙的要求进行设计。第 11.2.1 条 有抗震设防要求的混凝土结构的混凝土强度等级应符合下列要求:1设防烈度为9度时,混凝土强度等级不宜超过 C60设防烈度为8度时,混凝土强度等级不宜超C30;其他各2 框支梁、框支柱以及一级抗震等级的框架梁、柱、节
18、点,混凝土强度等级不应低于第二章 建筑抗震设计规范 GB 50011-2001 中有关规定第 3.9.2 条 结构材料性能指标应符合下列最低要求:2 混凝土结构材料应符合下列规定 :1) 混凝土的强度等级,框支梁、框支柱及抗震等级为一级的框架梁、柱节点核芯区,不应低于 应低于 C20;2) 抗震等级为一、二级的框架结构,其纵向受力钢筋采用普通钢筋时,钢筋的抗拉强度实测值与 筋的屈服强度实测值与强度标准值的比值不应大于 1.3 ;第 6.1.14 条 地下室顶板作为上部结构的嵌固部位时,应避免在地下室顶板开设大洞口,并应采用混凝土强度等级不宜小于 C30应采用双层双向配筋,且每层每个方向的配筋率
19、不宜小于 0.25%; 楼层侧向刚度的 2 倍,地下室柱截面每侧的纵向钢筋面积,除应满足计算要求外 , 不应少于地上一 框架结构柱和抗震墙墙底截面的弯矩设计值应符合本章第 6.2.3 、6.2.6 、6.2.7 条的规定,位于地 承载力之和不宜小于上下柱端实际受弯承载力之和。第条框支层应采用现浇楼板,厚度不宜小于 180mm混凝土强度等级不宜低于 C30,应采丿 应小于 0.25%。第三章 高层建筑混凝土结构技术规程 JGJ 3-2002 中有关规定第条现浇楼盖的混凝土强度等级不宜低于 C20不宜高于C4(。第 4.5.5 条 作为上部结构嵌固部位的地下室顶层的顶楼盖应采用梁板结构,楼板厚度不
20、宜小于 1 双层双向配筋,且每层每个方向的配筋率不宜小于0.25%。第 6.1.8 条 现浇框架梁、柱、节点的混凝土强度等级,按一级抗震等级设计时,不应低于C30;第条现浇框架梁的混凝土强度等级不宜高于 C40;框架柱的混凝土强度等级,抗震设防烈度时不宜大于 C70。第721条剪力墙结构的混凝土强度等级不应低于C20;带有筒体和短肢剪力墙的剪力墙结构的第 9.1.3 条 筒体结构的混凝土强度等级不宜低于 C30.第条 转换层楼面应采用现浇楼板,其混凝土强度等级不应小于C3C。框支层、框支柱、箱不应小于 C30。第条错层处框架柱的截面高度不应小于 600mm混凝土强度等级不应小于 C3Q抗震等级
21、 第 10.4.5 条 错层处剪力墙的混凝土强度等级不应小于C30。第 12.1.9 条 高层建筑基础的混凝土强度等级不宜低于C30。第四章 建筑地基基础设计规范 GB 50007-2002中有关规定第条 无筋扩展基础混凝土基础质量要求:C15混凝土第 8.2.2 条 扩展基础应满足下列要求:2垫层厚度不宜小于70mm垫层混凝土等级应为C104 混凝土等级不应低于 C20;第 8.4.3 条 筏形混凝土强度等级不应低于 C30。第 8.5.2 条 桩和桩基的构造,应符合下列要求:5预制桩的混凝土强度等级不应低于 C30;灌注桩不应低于C20预应力桩不应低于C4(。第 8.5.15 条 桩基承台
22、的构造,应符合下列要求:4 承台混凝土强度等级不应低于 C20;第 8.5.19 条 当承台的混凝土强度等级低于柱或桩的混凝土等级时,尚应验算柱下或桩上承台局部第 8.5.2 条 岩石锚杆基础,应符合下列要求:3锚杆宜采用热轧带肋钢筋,水泥沙浆强度不宜低于30MPa细石混凝土强度等级不宜低于 C3C。混凝土强度等级的选用表 序号结构类别混凝土最低强度等级混凝土适宜强度等级备注1 基础垫层 C10C10, C152 无筋扩展基础 C15C15, C203扩展基础C2OC20 C25独立基础,条形基础4 预制桩 C305灌注桩C20C20 C25, C30扩大头C306 预应力桩 C4O7承台(多
23、层)C20C20 C25, C30满足局部承压8承台(高层)C30C30 C35满足局部承压9筏板基础C30C30 C35, C40满足局部承压10 岩石锚杆 C30C30 C35 C4011地下室底板C30C30 C35抗渗按高规采用12侧壁C30C30 C35抗渗按高规采用13顶板C30C30 C35, C40不宜大于C4014柱一级抗震柱 C30C30,C35,C40,C45,C50,C559度时不宜超过 C60; 8度时不宜超过 C7015 二四级抗震柱 C20C20,C25,C30,C35,C40,C45,C50,C5516 非抗震柱 C20C20,C25,C30,C35,C40,C
24、45,C50,C5517框支柱 C30C30,C35,C40,C45,C50,C5518错层柱 C30C30,C35,C40,C45,C50,C55 19 构造柱、芯柱 C20C20,C25,C3020梁一级抗震梁C30C30,C35,C40不宜大于C4021 二四级抗震梁 C20C20,C25,C30,C35,C4022 非抗震梁 C20C20,C25,C30,C35,C4023 预应力梁 C30C30,C35,C4024 框支梁 C30C30,C35,C4025 圈梁 C20C20,C25,C3026板普通现浇板C20C20,C25,C30,C35,C40不宜大于C4027 转换厚板 C3
25、0C30,C35,C4028 转换层板 C30C30,C35,C4029 剪力墙剪力墙 C20C25,C30,C35,C4030 短肢剪力墙 C25C25,C30,C35,C4031 错层剪力墙 C30C30,C35,C4032 核心筒 C25C25,C30,C35,C4033 筒体剪力墙 C30C30,C35,C40混凝土配合比表(1)现浇碎石混凝土配合比(单位:立方米)定额编号1r 2:二 3r 4 n5项目C15L C20 JrC251 C30 1C35碎石粒径16mm材料单位数量数量数量数量数量32.5Mpa 水泥吨0.3070.4000.4600.530-42.5Mpa 水泥吨-0.
26、460中砂立方米0.5110.4110.3620.3480.362<16mn石子立方米0.8300.8700.8790.8450.879水立方米0.2200.2200.2200.2200.220定额编号6 78910项目C40C45C15C20C25碎石粒径16mm碎石粒径20mm材料单位数量数量数量数量数量32.5Mpa 水泥吨-0.2860.3720.42842.5Mpa 水泥吨0.530-52.5Mpa 水泥吨-0.472-中砂立方米0.3480.3600.5070.4090.359<16mn石子立方米0.8450.873-<20mn石子立方米-0.8600.9030.
27、914水立方米0.2200.2200.2000.2000.200定额编号11121314项目C30C35C40C45碎石粒径20mm材料单位数量数量数量数量32.5Mpa 水泥吨0.493-42.5Mpa 水泥吨-0.4280.493-52.5Mpa 水泥吨-0.437中砂立方米0.3460.3590.3460.370<20mn石子立方米0.8830.9140.8830.897水立方米0.200 0.200 0.200 0.200定额编号1516171819项目C15C20C25C30C35碎石粒径31.5mm材料单位数量数量数量数量数量32.5Mpa 水泥吨0.2710.3520.40
28、60.467-42.5Mpa 水泥吨-0.406中砂立方米0.4990.4020.3530.3420.353<31.5m m 石子立方米0.8840.9300.9430.9130.943水立方米0.1900.1900.1900.1900.190定额编号2021222324项目C40C45C50C55C60碎石粒径31.5mm材料单位数量数量数量数量数量42.5Mpa 水泥吨0.467-52.5Mpa 水泥吨-0.4150.456-62.5Mpa 水泥吨-0.4150.444中砂立方米0.3420.3510.3440.3510.346<31.5m m 石子立方米0.9130.9390
29、.9190.9390.924水立方米0.1900.1900.1900.1900.190定额编号2526272829项目C15C20C25C30C35碎石粒径40mm材料单位数量数量数量数量数量32.5Mpa 水泥吨0.2600.3330.3840.442-42.5Mpa 水泥吨-0.384中砂立方米0.4910.3940.3460.3360.346<40mn石子立方米0.9090.9580.9730.9430.973水立方米0.1800.1800.1800.1800.180(2)预制碎石混凝土配合比(单位:立方米)定额编号F2F3L4 15项目C20C25rC30rC35!C40碎石粒径
30、16mm材料单位数量数量数量数量数量32.5Mpa 水泥吨0.3810.4390.505-42.5Mpa 水泥吨-0.4390.505中砂立方米0.4180.3690.3550.3690.355<16mn石子立方米0.8830.8930.8620.8930.862水立方米0.2100.2100.2100.2100.210定额编号6匚78910项目C45C50C20C25C30碎石粒径16mm碎石粒径20mm材料单位数量数量数量数量数量32.5Mpa 水泥吨-0.3520.4060.46742.5Mpa 水泥吨-52.5Mpa 水泥吨0.4480.493-中砂立方米0.3670.3580.
31、4150.3650.354<16mn石子立方米0.8890.867-<20mn石子立方米-0.9160.9310.900水立方米0.2100.2100.1900.1900.190定额编号11121314项目C35C40C45C50碎石粒径20mm材料单位数量数量数量数量42.5Mpa 水泥吨0.4060.467-52.5Mpa 水泥吨-0.4150.456中砂立方米0.3650.3540.3640.356<20mn石子立方米0.9310.9000.9260.906水立方米0.1900.1900.1900.190定额编号1516171819项目C20C25C30C35C40碎石
32、粒径40mm材料单位数量数量数量数量数量32.5Mpa 水泥吨0.3140.3620.416-42.5Mpa 水泥吨-0.3620.416中砂立方米0.4000.3520.3420.3520.342<40mn石子立方米0.9720.9890.9620.9890.962水立方米0.1700.1700.1700.1700.170定额编号2021项目C45C50碎石粒径40mm材料单位数量数量52.5Mpa 水泥吨0.3710.406中砂立方米0.3510.344<40mn石子立方米0.9850.967水立方米0.1700.170(3)水下灌注碎石混凝土配合比(单位:立方米)定额编号12
33、345项目C20C25C30C35C40碎石粒径31.5mm材料单位数量数量数量数量数量32.5Mpa 水泥吨0.4410.501-42.5Mpa 水泥吨-0.4110.501-52.5Mpa 水泥吨-0.469中砂立方米0.5450.5270.5440.5270.536<31.5m m 石子立方米0.6920.700.6910.700.682水立方米0.2340.2340.2340.2340.234目录一. 外墙外保温施工工艺1(一)、施工依据:1(二)、施工做法1二. 质量标准7三、质量保证措施10四、成品保护措施10五、材料节约措施:11六、安全及文明施工措施:11七、其它注意事项
34、12亠工程概况信息工程大学干教休息用房一期工程 1#、3#、5#、7#楼6层及以上外墙外保温采用 聚苯板薄抹灰外墙外保温系统.5层及以下外墙外保温采用机械固定聚苯板钢丝网架板外 墙外保温系统。:外墙外保温施工工艺(一)、施工依据国家有关过程施工规范和规定:05YJ系列图集外墙外保温工程技术规程(JGJ 144-2004)河南省居住建筑节能设计标准(DNJ 41/062- 2005)建筑外墙保温技术导则 (RISN TG 001 -2005)建筑工程施工质量验收统一标准;建设工程安全生产管理条例;建筑施工手册(二)、施工做法对于本工程,采用聚苯板薄抹灰施工方法在外墙外保温施工前先进行外墙粉刷,外
35、墙粉 刷范围为:外墙加气混凝土砌块部位,采用1: 2水泥砂浆粉刷20mm厚。1。总则1。1本规程是以聚苯乙烯泡沫塑料为保温材料,耐碱玻纤网格布为增强材料,外墙外河南省第一建筑工程集团有限责任公司第1页保温专用粘接砂浆和外墙外保温专用罩面砂浆作面层的建筑外墙外保温体系的施工标准和验收标准。该外墙外保温体系基本构造见表1:表1外墙外保温基本构造外墙外保温作法构造示意图粘结层保温层保护层外饰面钢筋混凝聚苯乙耐碱玻纤网按设计要j, r jT外保温L I F土墙、砌烯泡沫格布增强求做外饰 T粘结砂块墙、粘塑料板3 5mm夕卜面r u 二i",严” O浆 H N .J _ 一 J =.-土砖墙等
36、保温用罩面砂浆除遵守本规程外,尚应遵守国家及本市现行的有关标准的规定2. 材料准备2.1材料(1) 聚苯乙烯泡沫塑料板(以下简称聚苯板):表2聚苯板技术性能要求表面密度导热系数吸水率氧指数抗拉强抗压强厚度厚度(kg/m外保温用粘接砂浆和外保温用罩面砂浆技术性能指标需符合表3和4要求。 表3外墙外保温用粘接砂浆技术性能指标)(w/m k)% (v/v)(%)度(kpa)度(mm)偏差(kpa)(mm)20毛.041230203另950±试验项目性能指标拉伸胶接强度,Mpa(与水泥砂浆)常温常态200 70耐水20.50耐冻融(冻融循环25次)20。50抗拉胶接强度,Mpa常温常态2.1
37、0且聚苯板破坏(与18±kg/m耐碱玻璃纤维涂塑网格布(以下简称网格布):耐碱性能应符合耐碱玻璃纤维无捻粗纱(JC/T572-94)中对耐碱性的要求。2。2工具电热切割丝、手锯、壁纸刀、螺丝刀、剪刀、扫帚、钢丝刷、墨斗、棕刷、电动搅拌器、河南省第一建筑工程集团有限责任公司第3页膨胀聚苯板)耐水2.10且聚苯板破坏可操作时间,h2表4外墙外保温罩面用砂浆性能指标试验项目性能指标拉伸胶接强度,Mpa(与水泥砂浆)常温常态2。70耐温2.50耐水2.50抗拉胶接强度,Mpa常温常态2.10且聚苯板破坏(与18±kg/m3膨胀聚苯耐水2.10且聚苯板破坏板)耐冻融2。10且聚苯板破
38、坏可操作时间,h2柔韧性,28d压折比(抗压强度/抗折强度)抗裂性(厚度5mm以下)无裂纹冲击钻、抹子、打磨抹子、压子、阴阳角抿子、托线板、2m靠尺等2。3施工条件外墙和外门窗口施工及验收完毕,基面达到建筑工程质量检验评定标准(GBJ30188)中第五章第三节“混凝土工程”中对多层大模的要求 .2。 3。2操作地点环境温度和基底温度不低于 5C、风力不大于5级,雨雪天不能施工。由土建方清除施工基层上的浮灰、疏松物油污和其他废弃物,油污用10%NaOH溶液清 洗并用清水冲净。3. 施工工艺对于本工程,在外墙外保温施工前先进行外墙粉刷,外墙粉刷范围为:外墙加气混凝土砌 块部位,采用1:2水泥砂浆粉
39、刷20mm厚.3。1。本作法采用由下到上施工,按“表一”的程序施工。3。2。1基层处理结构墙体基面必须清理干净,并检验墙面平整度 和垂直度.用2m靠尺检查,最大偏差不大于5mm,超差部分应由土建方剔凿或用聚合物水泥砂浆修补平整。3.2。2变形缝处留设根据图纸要求,在墙面弹出变形缝线.遵循以下几个原则:a)外保温系统与不同材料相接处b)墙面的连续高、宽度每超过20m,且未设其它变形缝时c)结构可能产生较大位移的部位。粘贴聚苯板1. 聚苯板切割:用电热丝切割器或手用刀锯切割,标准板面尺寸为1200>600m m,对角河南省第一建筑工程集团有限责任公司第4页线及板厚误差土2mn,非标准板按实际
40、需要的尺寸加工,尺寸允许偏差为± 2mn,大小面垂直2。粘接剂配制:将外保温专用粘接干粉与水按4: 1比例配制,用电动搅拌器搅拌均匀, 一次配制量以2小时内用完,若使用中有过干现象出现,可适当加水再次搅匀使用。3. 变形缝两侧及门窗洞口边缘处应预贴 250mn宽翻包网格布,可根据实据情况将网格布 先预粘于上述要求部位。4。 用粘接剂在聚苯板面四周涂抹一圈粘接剂,宽 50mm板心按梅花形布设粘接点,间 距150m200mm直径100mm(见附详图)。 标准层的聚苯板粘贴面积应不小于 40%。EPS板应按顺砌方式粘贴,竖缝应逐行错 缝.EPS板应粘贴牢固,不得有松动和空鼓.墙角处EPS板
41、应交错互锁(图6. 1. 9a).门窗 洞口四角处EPS板不得拼接,应采用整块EPS板切割成形,EPS板接缝应离开角部至少 200mm图 6. 1. 9b)。粘接层厚度以能调平聚苯板粘贴层为宜,不宜大于5mm,粘接层越厚,粘接缺馅越。抹完粘接剂后,立即将板立起粘贴,粘贴时轻揉、均匀挤压,并用托线板检查垂直平 整,板与板间挤紧,碰头缝处不留粘接剂。粘贴聚苯板时应做到上下错缝,每贴完一块板, 应及时清除挤出的粘接剂,板间不留间隙,如出现间隙,应用相应宽度的聚苯板填塞挤实。 阳角处相邻的墙面所粘聚苯板应错缝粘贴.5. 聚苯板接缝不平处应用打磨抹子磨平,打磨动作宜为轻柔的圆周运动。磨平后应用刷 子将碎
42、屑清理干净。磨平时间在聚苯板粘贴24小时后进行,以避免对聚苯板粘贴层的扰动6、聚苯板固定聚苯板采用保温钉与基层进行固定(每平方米不少于7个),局部采用膨胀螺丝辅助固定。施工工艺流程图如下图所示:基面准备测量、放线挂基准线材料准备界面j浆 砂I粘接砂浆粘聚苯板安装锚固件打磨、修理、隐检抹底戻罩面砂浆贴玻纤网格布压入砂浆抹面戻罩面砂浆修整、验收外_饰_面3.2。4抹罩面砂浆底层:聚苯板粘贴24小时后,即可进行下一步的操作。1. 配制外保温专用罩面砂浆:将罩面用干粉与水按4:1比例配制,用电动搅拌器搅拌均匀,一次配制量以2小时内用完为宜,若有过干现象出现,可适当加水再搅匀使用。2。在聚苯板表面均匀涂
43、抹一层配制好的罩面砂浆,厚度不宜超过3mm.3。2。5贴网格布1. 平门窗洞口如不靠膨胀缝,沿45度角方向各加一层400m时200mn网格布进行加强, 加强部位于大面网格布下面(见附图)2。 将大面网格布沿水平方向绷平,用抹子由中间向左右两边将网格布抹平 ,将其压入底 层抹面砂浆,网格布左右搭接宽度不小于 100mm上、下搭接宽度不小于80mm不得使网格 布皱褶、翘边.3。膨胀缝处网格布应断开,但装饰缝处网格布不得搭接和断开。4. 阴角及窗口作法见附详图抹罩面砂浆防护面层1. 抹面层聚合物砂浆,抹灰厚度以盖住网格布为准,约2mm,总厚度不宜大于5mm。二. 质量标准1. 保证项目1。1.聚苯板
44、、网格布、管材的规格和各项技术指标,粘接干粉、罩面干粉的配制原料的质 量,必须符合本规程及有关标准的要求.检验方法:检查出厂合格证。1。2.聚苯板必须与墙面粘接牢固,无松动和虚粘现象。检查数量:按楼每20m长抽查一处(每处3延米长),但不小于3处.检查方法,观察 和用手推拉检查。1。3.粘结砂浆与聚苯板必须粘接牢固,无脱层、空鼓,面层无爆灰和裂缝检查数量:同1.2检查方法:用小锤轻击和观察检查。2。基本项目2。1。每块聚苯板与墙面的总粘接面积,首层不得小于 50%,其它层不得小于30%。检查数量:按每楼抽查三处,每处检查不小于2块。检查方法:尺量检查取其平均值.注:检查应在粘接剂凝结前进行.2
45、。2。尼龙胀塞尖全部进入结构墙体。检查数量:同2。1。2。3。聚苯板碰头缝处不抹粘接剂。检查数量:同2.1。 检查方法:观察检查。2。4。网格布应横向铺设,压贴密实,不能有空鼓、皱折、翘曲、外露等现象,搭接宽度 左右不得小于100mm,上下不得小于80mm.检查数量:同2。1。检查方法:观察及尺量检查。2。5。聚合物罩面砂浆保护层总厚度不宜大于 5mm,首层不宜大于7mm.检查数量:同2.1。检查方法:尺量检查。注:检查应在砂浆凝结前进行。3。允许偏差项目3。1.聚苯板粘贴允许误差应符合表 5的规定。表5聚苯板安装的允许偏差及检查方法项次项目允许偏差(mm)检查方法1表面平整3用2m靠尺和楔形
46、塞尺检查2垂直度每层3用2m托线板检查全高h/1000且不大于20用经纬仪或吊线和尺量检查3阴阳角垂直3用2m托线板检查4阴阳角方正3用200mm方尺和楔形塞尺检查5接缝高差1。5用直尺和楔形塞尺检查注:h为墙全高;检查数量:同2.1。3。2。保温墙罩面抹灰执行国家建筑工程质量检验评定标准(GBJ301 88)第一章第一节“一般抹灰工程”的规定.允许偏差及检查方法:序号项 目允许偏差(mm)检验方法1表面平整度4用2m靠尺、塞尺检查2立面垂直度4用2m托线板检查3阴阳角垂直4用2m托线板检查4阴阳角方正4用 200 mm方尺和楔型塞尺检杳5伸缩缝(装饰线)平直3拉5m线和直尺检杳三、质量保证措施1. 本工程质量目标设计:优良.2. 质量保证体系框架图:3。 严格遵守建筑工程施工技术规程、建筑工程质量检验与评定标准.4。本工
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025关于家具买卖合同书范本
- 2025年设备采购与销售合同范本
- 重庆科技职业学院《电机学基础》2024-2025学年第一学期期末试卷
- 山东枣庄八中北校区2023年高二物理第一学期期末综合测试模拟试题含解析
- 2025年教育机构合作协议合同协议
- 安徽省黄山市八校联盟2026届生物高一上期末质量检测试题含解析
- 上海现代化工职业学院《矿井火灾防治(英语)》2024-2025学年第一学期期末试卷
- 山东省德州市陵城区一中2025年高二上生物期末达标检测试题含解析
- 中国石油大学(北京)《石油及天然气地质学实验》2024-2025学年第一学期期末试卷
- 2026届扬州市扬州中学生物高二第一学期期末质量检测试题含解析
- 2025年重阳节敬老孝老主题班会《尊老敬老爱满重阳》课件
- 福建专升本大学语文复习(宾莹)
- 产科疾病常用药物
- 山西建设工程消防设施检测报告示范文本模板
- 2023年高考语文二轮复习专题训练专题03诗歌鉴赏之客观选择题专训(1)Word版含解析
- 2021年光学行业深度分析报告
- GB/T 18241.3-2000橡胶衬里第3部分:浮选机衬里
- GB/T 13477.8-2017建筑密封材料试验方法第8部分:拉伸粘结性的测定
- 四年级上册中国优秀传统文化教案(山东大学出版社)
- 电子商务专业职业生涯规划书
- 无人机驾驶员高级工职业资格考试题库(高频题汇总)
评论
0/150
提交评论