第 1 页,共 4 页采暖热负荷计算表房间编号名称及方向围护结构体积换气次数传热系数室内计算温度供暖室外计算温度室内外计算温度差温差修正系数基本耗热量修正后耗热量高度修正围护结构耗热量冷风渗透耗热量外门冷风侵入耗热量采暖热负荷户间传热总的采暖热负荷面积计算面积朝向风向修正后耗热量ktntwtQXchXf1+Xch+XFQXhQ1Q2Q3Qcn=Q1+Q2+Q3Qfj=Q1+Q2+Q3Q=Qcn+Qfj长宽高m2m3次w/m2. WWWWWWWW101屋面76.380.000.9720.002.0018.001.001333.590.000.001.001333.590.021360.271360.271360.27南外墙10.201.9720.002.0018.001.00361.69-0.250.000.75271.270.02276.69276.69276.69南外窗3.006.4020.002.0018.001.00345.60-0.250.000.75259.200.02264.38264.38264.38内墙30.801.3020.002.0018.000.70504.501.00504.500.02514.59514.59514.59内门3.604.6520.002.0018.001.00301.321.00301.320.02307.35307.35307.35缝隙渗透12.0020.002.0018.003.353.353.35小计放大系数为: 1.00 面积:76.38m2 负荷面积指标:35.70W/m22723.283.350.002726.630.002726.63该单元总计:2726.63 面积:76.38m2 负荷面积指标:35.70W/m2102屋面6.750.000.9720.002.0018.001.00117.850.000.001.00117.850.02120.21120.21120.21内墙13.201.3020.002.0018.000.70216.221.00216.220.02220.54220.54220.54小计放大系数为: 1.00 面积: 6.75m2 负荷面积指标:50.48W/m2340.750.000.00340.750.00340.75该单元总计:340.75 面积: 6.75m2 负荷面积指标:50.48W/m2103屋面5.100.000.9720.002.0018.001.0089.050.000.001.0089.050.0290.8390.8390.83内墙18.001.3020.002.0018.000.70294.841.00294.840.02300.74300.74300.74内门1.704.6520.002.0018.001.00142.291.00142.290.02145.14145.14145.14小计放大系数为: 1.00 面积: 5.10m2 负荷面积指标:105.24W/m2536.710.000.00536.710.00536.71该单元总计:536.71 面积: 5.10m2 负荷面积指标:105.24W/m2104屋面5.100.000.9720.002.0018.001.0089.050.000.001.0089.050.0290.8390.8390.83内墙9.001.3020.002.0018.000.70147.421.00147.420.02150.37150.37150.37内门1.704.6520.002.0018.001.00142.291.00142.290.02145.14145.14145.14小计放大系数为: 1.00 面积: 5.10m2 负荷面积指标:75.75W/m2386.340.000.00386.340.00386.34该单元总计:386.34 面积: 5.10m2 负荷面积指标:75.75W/m2105屋面5.600.000.9720.002.0018.001.0097.780.000.001.0097.780.0299.7399.7399.73内墙8.001.3020.002.0018.000.70131.041.00131.040.02133.66133.66133.66内门1.704.6520.002.0018.001.00142.291.00142.290.02145.14145.14145.14小计放大系数为: 1.00 面积: 5.60m2 负荷面积指标:67.59W/m2378.530.000.00378.530.00378.53该单元总计:378.53 面积: 5.60m2 负荷面积指标:67.59W/m2106屋面29.700.000.9720.002.0018.001.00518.560.000.001.00518.560.02528.93528.93528.93内墙50.761.3020.002.0018.000.70831.451.00831.450.02848.08848.08848.08小计放大系数为: 1.00 面积:29.70m2 负荷面积指标:46.36W/m21377.010.000.001377.010.001377.01该单元总计:1377.01 面积:29.70m2 负荷面积指标:46.36W/m2107屋面17.100.000.9720.002.0018.001.00298.570.000.001.00298.570.02304.54304.54304.54内墙12.001.3020.002.0018.000.70196.561.00196.560.02200.49200.49200.49小计放大系数为: 1.00 面积:17.10m2 负荷面积指标:29.53W/m2505.030.000.00505.030.00505.03第 2 页,共 4 页采暖热负荷计算表房间编号名称及方向围护结构体积换气次数传热系数室内计算温度供暖室外计算温度室内外计算温度差温差修正系数基本耗热量修正后耗热量高度修正围护结构耗热量冷风渗透耗热量外门冷风侵入耗热量采暖热负荷户间传热总的采暖热负荷面积计算面积朝向风向修正后耗热量ktntwtQXchXf1+Xch+XFQXhQ1Q2Q3Qcn=Q1+Q2+Q3Qfj=Q1+Q2+Q3Q=Qcn+Qfj长宽高m2m3次w/m2. WWWWWWWW该单元总计:505.03 面积:17.10m2 负荷面积指标:29.53W/m2108屋面14.000.000.9720.002.0018.001.00244.440.000.001.00244.440.02249.33249.33249.33内墙15.201.3020.002.0018.000.70248.981.00248.980.02253.96253.96253.96小计放大系数为: 1.00 面积:14.00m2 负荷面积指标:35.95W/m2503.290.000.00503.290.00503.29该单元总计:503.29 面积:14.00m2 负荷面积指标:35.95W/m2109屋面23.700.000.9720.002.0018.001.00413.800.000.001.00413.800.02422.08422.08422.08内墙16.601.3020.002.0018.000.70271.911.00271.910.02277.35277.35277.35小计放大系数为: 1.00 面积:23.70m2 负荷面积指标:29.51W/m2699.430.000.00699.430.00699.43该单元总计:699.43 面积:23.70m2 负荷面积指标:29.51W/m2110屋面17.400.000.9720.002.0018.001.00303.800.000.001.00303.800.02309.88309.88309.88内墙12.201.3020.002.0018.000.70199.841.00199.840.02203.83203.83203.83小计放大系数为: 1.00 面积:17.40m2 负荷面积指标:29.52W/m2513.710.000.00513.710.00513.71该单元总计:513.71 面积:17.40m2 负荷面积指标:29.52W/m2111屋面18.810.000.9720.002.0018.001.00328.420.000.001.00328.420.02334.99334.99334.99内墙36.001.3020.002.0018.000.70589.681.00589.680.02601.47601.47601.47小计放大系数为: 1.00 面积:18.81m2 负荷面积指标:49.79W/m2936.460.000.00936.460.00936.46该单元总计:936.46 面积:18.81m2 负荷面积指标:49.79W/m2112屋面5.040.000.9720.002.0018.001.0088.000.000.001.0088.000.0289.7689.7689.76小计放大系数为: 1.00 面积: 5.04m2 负荷面积指标:17.81W/m289.760.000.0089.760.0089.76该单元总计:89.76 面积: 5.04m2 负荷面积指标:17.81W/m2113屋面16.530.000.9720.002.0018.001.00288.610.000.001.00288.610.02294.39294.39294.39内墙19.201.3020.002.0018.000.70314.501.00314.500.02320.79320.79320.79小计放大系数为: 1.00 面积:16.53m2 负荷面积指标:37.22W/m2615.180.000.00615.180.00615.18该单元总计:615.18 面积:16.53m2 负荷面积指标:37.22W/m2114东外墙15.200.001.9720.002.0018.001.00538.99-0.050.000.95512.040.02522.28522.28522.28南外墙35.001.9720.002.0018.001.001241.10-0.250.000.75930.830.02949.44949.44949.44南外窗9.006.4020.002.0018.001.001036.80-0.250.000.75777.600.02793.15793.15793.15内墙21.201.3020.002.0018.000.70347.261.00347.260.02354.20354.20354.20屋面36.670.9720.002.0018.001.00640.260.000.001.00640.260.02653.06653.06653.06缝隙渗透36.0020.002.0018.0010.0510.0510.05小计放大系数为: 1.00 面积:36.67m2 负荷面积指标:89.51W/m23272.1310.050.003282.180.003282.18该单元总计:3282.18 面积:36.67m2 负荷面积指标:89.51W/m2第 3 页,共 4 页采暖热负荷计算表房间编号名称及方向围护结构体积换气次数传热系数室内计算温度供暖室外计算温度室内外计算温度差温差修正系数基本耗热量修正后耗热量高度修正围护结构耗热量冷风渗透耗热量外门冷风侵入耗热量采暖热负荷户间传热总的采暖热负荷面积计算面积朝向风向修正后耗热量ktntwtQXchXf1+Xch+XFQXhQ1Q2Q3Qcn=Q1+Q2+Q3Qfj=Q1+Q2+Q3Q=Qcn+Qfj长宽高m2m3次w/m2. WWWWWWWW115屋面15.120.000.9720.002.0018.001.00264.000.000.001.00264.000.02269.28269.28269.28小计放大系数为: 1.00 面积:15.12m2 负荷面积指标:17.81W/m2269.280.000.00269.280.00269.28该单元总计:269.28 面积:15.12m2 负荷面积指标:17.81W/m2116屋面6.720.000.9720.002.0018.001.00117.330.000.001.00117.330.02119.68119.68119.68南外墙8.201.9720.002.0018.001.00290.77-0.250.000.75218.080.02222.44222.44222.44南外窗3.006.4020.002.0018.001.00345.60-0.250.000.75259.200.02264.38264.38264.38缝隙渗透12.0020.002.0018.003.353.353.35小计放大系数为: 1.00 面积:15.12m2 负荷面积指标:40.33W/m2606.503.350.00609.850.00609.85该单元总计:609.85 面积:15.12m2 负荷面积指标:40.33W/m2117屋面4.200.000.9720.002.0018.001.0073.330.000.001.0073.330.0274.8074.8074.80南外墙8.201.9720.002.0018.001.00290.77-0.250.000.75218.080.02222.44222.44222.44南外窗3.006.4020.002.0018.001.00345.60-0.250.000.75259.200.02264.38264.38264.38内墙6.001.3020.002.0018.000.7098.281.0098.280.02100.25100.25100.25缝隙渗透12.0020.002.0018.003.353.353.35小计放大系数为: 1.00 面积: 4.20m2 负荷面积指标:158.39W/m2661.873.350.00665.220.00665.22该单元总计:665.22 面积: 4.20m2 负荷面积指标:158.39W/m2118屋面7.560.000.9720.002.0018.001.00132.000.000.001.00132.000.02134.64134.64134.64内墙3.201.3020.002.0018.000.7052.421.0052.420.0253.4653.4653.46小计放大系数为: 1.00 面积: 7.56m2 负荷面积指标:24.88W/m2188.100.000.00188.100.00188.10该单元总计:188.10 面积: 7.56m2 负荷面积指标:24.88W/m2119屋面9.880.000.9720.002.0018.001.00172.500.000.001.00172.500.02175.95175.95175.95小计放大系数为: 1.00 面积: 9.88m2 负荷面积指标:17.81W/m2175.950.000.00175.950.00175.95该单元总计:175.95 面积: 9.88m2 负荷面积指标:17.81W/m2120屋面5.040.000.9720.002.0018.001.0088.000.000.001.0088.000.0289.7689.7689.76小计放大系数为: 1.00 面积: 5.04m2 负荷面积指标:17.81W/m289.760.000.0089.760.0089.76该单元总计:89.76 面积: 5.04m2 负荷面积指标:17.81W/m2121屋面9.880.000.9720.002.0018.001.00172.500.000.001.00172.500.02175.95175.95175.95南外墙12.201.9720.
温馨提示:
1: 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
2: 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
3.本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
提示  人人文库网所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
关于本文
本文标题:大型制药厂热电冷三联供设计【含CAD图纸】
链接地址:https://www.renrendoc.com/paper/211386458.html

官方联系方式

2:不支持迅雷下载,请使用浏览器下载   
3:不支持QQ浏览器下载,请用其他浏览器   
4:下载后的文档和图纸-无水印   
5:文档经过压缩,下载后原文更清晰   
关于我们 - 网站声明 - 网站地图 - 资源地图 - 友情链接 - 网站客服 - 联系我们

网站客服QQ:2881952447     

copyright@ 2020-2025  renrendoc.com 人人文库版权所有   联系电话:400-852-1180

备案号:蜀ICP备2022000484号-2       经营许可证: 川B2-20220663       公网安备川公网安备: 51019002004831号

本站为文档C2C交易模式,即用户上传的文档直接被用户下载,本站只是中间服务平台,本站所有文档下载所得的收益归上传人(含作者)所有。人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对上载内容本身不做任何修改或编辑。若文档所含内容侵犯了您的版权或隐私,请立即通知人人文库网,我们立即给予删除!