1、PAGE 5EMC存储系统安装配置手册目 录 TOC o 1-4 h z HYPERLINK l _Toc505886830 第1章概述 PAGEREF _Toc505886830 h 6 HYPERLINK l _Toc505886831 1.1编写目的 PAGEREF _Toc505886831 h 6 HYPERLINK l _Toc505886832 1.2参考文档 PAGEREF _Toc505886832 h 7 HYPERLINK l _Toc505886833 第2章存储硬件安装 PAGEREF _Toc505886833 h 8 HYPERLINK l _Toc5058868

2、34 2.1EMC CX3中端磁盘阵列安装配置 PAGEREF _Toc505886834 h 8 HYPERLINK l _Toc505886835 第3章存储软件安装配置 PAGEREF _Toc505886835 h 9 HYPERLINK l _Toc505886836 3.1整体说明 PAGEREF _Toc505886836 h 9 HYPERLINK l _Toc505886837 3.2IBM AIX平台软件安装 PAGEREF _Toc505886837 h 9 HYPERLINK l _Toc505886838 3.2.1IBM pSeries 安装需求 PAGEREF _

3、Toc505886838 h 9 HYPERLINK l _Toc505886839 3.2.2ODM安装 PAGEREF _Toc505886839 h 11 HYPERLINK l _Toc505886840 3.2.3PowerPath的安装 PAGEREF _Toc505886840 h 16 HYPERLINK l _Toc505886841 PowerPath5.0.0安装需求 PAGEREF _Toc505886841 h 16 HYPERLINK l _Toc505886842 PowerPath5.0.0安装流程 PAGEREF _Toc505886842 h 16 HYPE

4、RLINK l _Toc505886843 3.2.4Navisphere Agent/Cli的安装 PAGEREF _Toc505886843 h 19 HYPERLINK l _Toc505886844 安装需求 PAGEREF _Toc505886844 h 19 HYPERLINK l _Toc505886845 安装流程 PAGEREF _Toc505886845 h 19 HYPERLINK l _Toc505886846 3.2.5HACMP相关设置 PAGEREF _Toc505886846 h 23 HYPERLINK l _Toc505886847 提示: PAGEREF

5、_Toc505886847 h 23 HYPERLINK l _Toc505886848 Set emcpowerreset in HACMP PAGEREF _Toc505886848 h 23 HYPERLINK l _Toc505886849 Add “cfgscsi_id” to HACMP(for CX3) PAGEREF _Toc505886849 h 23 HYPERLINK l _Toc505886850 3.2.6常用命令 PAGEREF _Toc505886850 h 25 HYPERLINK l _Toc505886851 3.2.7IBM AIX主机识别PowerPat

6、h管理的设备 PAGEREF _Toc505886851 h 26 HYPERLINK l _Toc505886852 3.3Redhat Linux平台软件安装 PAGEREF _Toc505886852 h 27 HYPERLINK l _Toc505886853 3.3.1PowerPath安装 PAGEREF _Toc505886853 h 27 HYPERLINK l _Toc505886854 安装需求 PAGEREF _Toc505886854 h 27 HYPERLINK l _Toc505886855 安装流程 PAGEREF _Toc505886855 h 28 HYPER

7、LINK l _Toc505886856 3.3.2Navisphere Agent/Cli安装 PAGEREF _Toc505886856 h 28 HYPERLINK l _Toc505886857 安装需求 PAGEREF _Toc505886857 h 28 HYPERLINK l _Toc505886858 安装流程 PAGEREF _Toc505886858 h 29 HYPERLINK l _Toc505886859 3.3.3Linux主机识别PowerPath管理的设备 PAGEREF _Toc505886859 h 29 HYPERLINK l _Toc505886860

8、3.4Windows2003平台软件安装 PAGEREF _Toc505886860 h 30 HYPERLINK l _Toc505886861 3.4.1PowerPath安装 PAGEREF _Toc505886861 h 30 HYPERLINK l _Toc505886862 安装需求 PAGEREF _Toc505886862 h 30 HYPERLINK l _Toc505886863 安装流程 PAGEREF _Toc505886863 h 30 HYPERLINK l _Toc505886864 3.4.2Navisphere Agent/Cli安装 PAGEREF _Toc

9、505886864 h 38 HYPERLINK l _Toc505886865 安装需求 PAGEREF _Toc505886865 h 38 HYPERLINK l _Toc505886866 安装流程 PAGEREF _Toc505886866 h 38 HYPERLINK l _Toc505886867 3.4.3Windows主机识别PowerPath管理的设备 PAGEREF _Toc505886867 h 47 HYPERLINK l _Toc505886868 3.5HP-UX平台软件安装 PAGEREF _Toc505886868 h 49 HYPERLINK l _Toc5

10、05886869 3.5.1PowerPath的安装 PAGEREF _Toc505886869 h 49 HYPERLINK l _Toc505886870 PowerPath5.0.1安装需求 PAGEREF _Toc505886870 h 49 HYPERLINK l _Toc505886871 PowerPath5.0.0安装流程 PAGEREF _Toc505886871 h 50 HYPERLINK l _Toc505886872 3.5.2Navisphere Agent/Cli的安装 PAGEREF _Toc505886872 h 54 HYPERLINK l _Toc5058

11、86873 安装需求 PAGEREF _Toc505886873 h 54 HYPERLINK l _Toc505886874 安装流程 PAGEREF _Toc505886874 h 54 HYPERLINK l _Toc505886875 3.5.3HPUX基本连接和认盘操作 PAGEREF _Toc505886875 h 56 HYPERLINK l _Toc505886876 3.5.4HP-UX主机识别PowerPath管理的设备 PAGEREF _Toc505886876 h 58 HYPERLINK l _Toc505886877 3.6在HPUX和MCSG中使用认到的磁盘 PA

12、GEREF _Toc505886877 h 59 HYPERLINK l _Toc505886878 3.6.1单机环境下使用到的磁盘 PAGEREF _Toc505886878 h 59 HYPERLINK l _Toc505886879 3.6.2在MC/SG中使用认到的盘,并在其它主机上IMPORT VG PAGEREF _Toc505886879 h 61 HYPERLINK l _Toc505886880 3.7PP在HPUX平台使用Clariion磁盘创建LVM注意事项: PAGEREF _Toc505886880 h 62 HYPERLINK l _Toc505886881 3.

13、7.1设置PV TIMEOUT值为180 PAGEREF _Toc505886881 h 62 HYPERLINK l _Toc505886882 3.7.2设置LV参数BBR为NONE PAGEREF _Toc505886882 h 62 HYPERLINK l _Toc505886883 3.7.3LV Striping PAGEREF _Toc505886883 h 62 HYPERLINK l _Toc505886884 3.8CX3Storage Group配置 PAGEREF _Toc505886884 h 63PAGE 7概述编写目的本文档描述了EMC CX3中端磁盘阵列、Bro

14、cade 48000光纤交换机的硬件安装及配置流程;IBM AIX、HP-UX、Linux、Windows等相关操作系统连接EMC磁盘阵列时主机端软件的安装以及配置流程。 本文档可作为新工程师现场安装时的手册使用,供大家在安装工作中参考。参考文档CX3安装配置手册EMC-PowerPath 安装配置手册EMCHandbookEMC-Best Practice For AIXPAGE 66存储硬件安装EMC CX3中端磁盘阵列安装配置存储软件安装配置整体说明根据新疆分行的设计方案,下表中列出了新疆分行中各主机需要安装的存储相关软件以及对应的版本信息,其中原则如下:所有连接EMC存储设备的主机都需

15、要安装PowerPath,版本选择当前较稳定的次新版本,如果客户没有买License则只装软件不激活高级功能。如果客户现场是单卡,单电源,单交换机需要提醒客户他的环境不符合标准,最好有文字确认;客户方案如果无热备盘,需要客户签字确认;Linux平台2.4 kernel只能安装PowerPath4.3.x版本,2.6以及以上kernel可以安装4.4.x及其以上版本。连接到EMC CX3磁盘阵列的主机需要安装Navisphere Agent/Cli,其版本要求与CX3的微码版本对应。IBM AIX主机需要安装ODM,ODM版本与AIX操作系统相关,AIX5.2及5.3安装ODM ;AIX5.1安

16、装ODM。IBM AIX平台软件安装IBM pSeries 安装需求主机系统的支持Supported Operating SystemMinimum Maintenance LevelRequired FilesetsaAIX 5.1 (32 and 64 bit)04 8(IBM PTF U486172)devices.fcp.disk.rte 6(IBM PTF U496905)AIX 5.2 (32 and 64 bit)02 7(IBM PTF U497114)devices.fcp.disk.rte 7(IBM PTF U497110)AIX 5.3 (32 and 64 bit)-

17、AIX系统要求的补丁 OSWithRequires APARAIX 5.2-IY50089ML-03IY56376, IY56769, and IY58189ML-04IY56722 and IY62118ML-04 and HBA 5716IY60183ML-04 and HBA 6227, 6228, or 6239IY62117AIX 5.3-IY62534HBA 5716IY62219HBA 6227, 6228, or 6239IY62221McData switchIY62221ODM安装下载ODM软件,软件下载地址为 HYPERLINK /pub/symm3000/aix/ODM

18、_DEFINITIONS/ /pub/symm3000/aix/ODM_DEFINITIONS/上传ODM软件包到主机上一个临时目录,例如/usr/emcsoft以root登陆主机# cd /usr/emcsoft# uncompress EMC.AIX*.Z# tar xvf EMC.AIX*.tar安装软件# smitty installp选择Install Software在“INPUT device /directory for software”中移动光标到右边输入软件放置目录/usr/emcsoft,然后在“SOFTWARE to install”中按“F4”键列出全部软件,可以看

19、见ODM软件包中包括许多软件项目,我们根据上面介绍的选择相应的安装软件包,光标移到需要安装的软件处,按ESC+7选择,其中软件包选择的原则为:如果是HA环境(CLARIION),则选择以下三个软件包EMC.CLARiiON.aix.rte EMC.CLARiiON.fcp.rteEMC.CLARiiON.ha.rte需要预先安装HACMP如果是HA环境(Symmetrix),则选择以下三个软件包EMC.Symmetrix.aix.rte EMC.Symmetrix.fcp.rteEMC.Symmetrix.ha.rte需要预先安装HACMP如果没有HA环境(CLARIION),则选择以下两个软

20、件包 (选1和4条)EMC.CLARiiON.aix.rte EMC.CLARiiON.fcp.rte 如果没有HA环境(Symmetrix),则选择以下两个软件包 EMC.Symmetrix.aix.rte EMC.Symmetrix.fcp.rte例如连接DMX3的HA环境(Symmetrix),则选择以下三个软件包“EMC Symmetrix AIX Support Software ,EMC Symmetrix FCP Support Software ,EMC Symmetrix HA Concurrent Support”选择完后,被选上的软件前面有“” 标记,然后按回车键,回到主

21、菜单,再按回车开始安装。安装过程如下图,按回车开始安装。注意相关安装信息。在下图信息中可以看见相关软件安装报告,Result 为:SUCCESS,ODM 安装成功。PowerPath的安装 PowerPath5.0.0安装需求PowerPath5.0.0对操作系统有以下要求:Supported Operating SystemMinimum Maintenance LevelRequired FilesetsAIX 5.2 (32 and 64 bit)08APAR IY88738AIX 5.3 (32 and 64 bit)04APAR IY89079其中AIX 5.3 TL5 SP6及其以

22、上版本需要升级到AIX 5.3 TL6 SP1 + IY98352,AIX 5.2 TL9 SP6及其以上版本需要升级到AIX 5.2 TL10 + IY98572。文件系统空间需求File System or DirectoryMinimum Space Requirements/ (root)5 MB/usr40 MB/tmp5 MBPowerPath5.0.0安装流程上传PowerPath5.0.0软件包EMCPower.AIX.5.0.0.tar.gz到主机上一个临时目录,例如/usr/emcsoft以root用户登陆安装软件 # gzip -d EMCPower.AIX.5.0.0.

23、tar.gz# tar -xvf EMCPower.AIX.5.0.0.tar # smitty installp开始图形界面安装,安装过程图示如下:同上面安装ODM一样选择放置软件的目录,POWERPATCH的安装可以选择PowerPath全部软件包安装,只需要按回车就可以了,安装完后注意一下屏幕上的信息提示,只要无错误信息就可以了。Result 状态为 SUCCESS,安装成功。因为POWERPATCH为全安装也可以使用如下命令行安装,同样注意最后屏幕提示信息即可#installp -aXgd . EMCpower确认EMCpower是否安装 #lslpp -L EMC*输出应该包含以下信

24、息:EMCpower.multi_path_clariion EMCpower.mpx EMCpower.migration_enabler EMCpower.consistency_grp PowerPath license key在一张纸上, 和设备及软件光盘介质一起到货,注册通过以下方式 #emcpreg install = EMC PowerPath Registration =Do you have a new registration key or keys to enter? n输入y,按回车继续。 Enter the registration key(s) for your p

25、roduct(s),one per line, pressing Enter after each key.After typing all keys, press Enter again.Key (Enter if done):输入powerpath注册码,然后按回车继续,成功后会显示以下提示信息。1 key(s) successfully added.Key successfully installed.Navisphere Agent/Cli的安装安装需求OSMinimum hardware requirementsMinimum software requirementsAIXIBM

26、AIX workstation with at least 64 MB of RAM and 14 MB of free disk space.OSIBM AIX Version 5.2 or 5.3 (32-bit or 64-bit).Note: AIX runtime environment should be of level 8 or higher.安装流程以 root用户登陆,首先更改光纤卡状态为pt2pt,执行以下命令更改当前两块光纤卡的状态:#rmdev -dl fscsi1 -R#chdev -l fcs1 -a init_link=pt2pt#rmdev -dl fscsi

27、0 -R#chdev -l fcs0 -a init_link=pt2pt接着执行以下命令:# cfgmgr v ;加载Navisphere agent安装光盘,#mount v cdrfs -p r /dev/cd0 /cdrom将Navispehere agent安装文件拷贝到/usr/sys/inst.images目录中 # cp /cdrom/ NAVIAGNT.lpp /usr/sys/inst.images# cp /cdrom/ NAVICLI.lpp /usr/sys/inst.images安装Agent#smitty installp选择Naviagent软件包;安装相关信息

28、图示如下:选择“Install and update from All Available software” 输入软件放置目录“/usr/sys/inst.images”按F4键列出安装软件。选择我们要安装的NAVIAGENT和NAVICLI,按回车开始安装。安装完在“/etc/Navisphere/agent.config”文件中添加如下内容:systemSPA_IPADDRESSsystemSPB_IPADDRESS这里SPA_IPADDRESS, SPB_IPADDRESS为EMC CX3存储SPA和SPB的地址*然后重启系统。系统重启时将自动启动agnet, 手工启动和停止agent

29、可用如下的命令#/etc/rc.agent start#/etc/rc.agent stopHACMP相关设置提示:如果HACMP的版本到了5.4或者5.4以上,以下步骤可是省略。Set emcpowerreset in HACMP对CX3/usr/sbin/cluster/utilities/clcustomdisk -c -tdisk/pseudo/power -Ndisk/pseudo/power gSCSI3 -hSCSI_TUR -b/usr/lpp/EMC/CLARiiON/bin/emcpowerreset pfalse mMKDEV设置完成以后,通过命令odmget HACMP

30、disktype可以查看到以下信息 HACMPdisktype: PdDvLn = disk/pseudo/power ghostdisks = SCSI3 checkres = SCSI_TUR breakres = /usr/lpp/EMC/bin/emcpowerreset parallel = false makedev = MKDEV reserved1 = reserved2 = reserved3 = Add “cfgscsi_id” to HACMP(for CX3)上传cfgscsi_id到主机/usr/sbinAdd the custom cluster event to

31、your HACMP configuration. This event is the name given to the script that will be added later to select pre-defined HACMP events. Note that this is one long command with no carriage returns./usr/es/sbin/cluster/utilities/claddcustom -t event -ncfgscsi_id -ISet correct scsi id on EMC CLARiiON pseudo

32、devices. -v/usr/sbin/cfgscsi_idVerify your custom cluster event was added correctly by running the command below and comparing the output.odmget HACMPcustomHACMPcustom:name = cfgscsi_idtype = eventdescription = Set correct scsi id on EMC CLARiiON pseudo devices.value = /usr/sbin/cfgscsi_idrelation =

33、 status = 0Run the two commands below to modify the pre-defined HACMP event by giving the event command your custom cluster event as a pre-event command./usr/es/sbin/cluster/utilities/clchevent -Onode_up -s/usr/es/sbin/cluster/events/node_up -b cfgscsi_id -c 0/usr/es/sbin/cluster/utilities/clchevent

34、 -Onode_down -s/usr/es/sbin/cluster/events/node_down -b cfgscsi_id -c 0Verify the events were properly modified by running the two commands below and comparing the output.odmget -q name=node_up HACMPeventHACMPevent:name = node_updesc = Script run when a node is attempting to join the cluster.setno =

35、 101msgno = 7catalog = events.catcmd = /usr/es/sbin/cluster/events/node_upnotify = pre = cfgscsi_idpost = recv = count = 0event_duration = 0odmget -q name=node_down HACMPeventHACMPevent:name = node_downdesc = Script run when a node is attempting to leave the cluster.setno = 101msgno = 8catalog = eve

36、nts.catcmd = /usr/es/sbin/cluster/events/node_downnotify = pre = cfgscsi_idpost = recv = count = 0event_duration = 0Once the cfgscsi_id utility has been installed and configured on every node in the cluster, synchronize the cluster and ensure there are no errors resulting from the addition of the pr

37、e-event scripts.常用命令#lsattr -El fscsi0查看fscsi设备的连接状态和fastfail, dyntrk等参数设置scsi_id 0 x10300 Adapter SCSI ID Falseattach switch How this adapter is CONNECTED Falsesw_fc_class 3 FC Class for Fabric Truefc_err_recov delayed_fail FC Fabric Event Error RECOVERY Policy True重启aix:shutdown -Fr#rmdev -dl fscs

38、i0 删除光纤协议设备,不建议删除fcs0设备。#rmdev -dl fscsi0 -R 删除光纤卡及其所连接设备,例如hdiskpower, hdisk, FC tape#cfgmgr -vl fcs0配置某光纤卡连接设备#cfgmgr -v配置所有设备#/usr/lpp/EMC/Symmetrix/bin/emc_cfgmgr 配置EMC Hdisk设备, 尤其是设备如果某台主机只访问BCV设备,需要在/etc/inittab文件结尾增加一行命令:$/mkbcv -a。这样当该主机重启时,BCV设备会自动变为Available状态。删除所有hdiskpower设备 for i in lsd

39、ev -Cc disk|grep hdiskpower|cut -c 1-13dormdev -dl $idone删除从hdiskpower0到hdiskpower100# i=0# while i -le 100 dormdev -dl hdiskpower$ilet i=i+1done删除所有hdisk设备# for i in lsdev -Cc disk|grep EMC|cut -c 1-8dormdev -dl $idone删除某块光纤卡的hdisk设备# lsdev -Cc adapter|grep fcs0fcs0 Available 20-58 FC Adapter# for

40、i in lsdev -Cc disk|grep 20-58|cut -c 1-8dormdev -dl $idoneIBM AIX主机识别PowerPath管理的设备主机认盘cfgmgr v执行powermt命令识别POWERPATH设备powermt config检查POWERPATH设备识别情况 lsdev Cc disk |grep hdiskpower检查磁盘路径, 正常结果CX3设备每个LUN有4个 path为alive状态;DMX3设备每个LUN有2个 path为alive状态powermt display dev=allPseudo name=hdiskpower0CLARii

41、ON ID=CK200065100269 xdhLogical device ID=600601609E031B009A09A96C2CE7DB11 LUN 1state=alive; policy=CLAROpt; priority=0; queued-IOs=0Owner: default=SP A, current=SP A= Host - Stor - - I/O Path - - Stats # HW Path I/O Paths Interf. Mode State Q-IOs Errors= 0 fscsi0 hdisk4 SP A1 active alive 0 0 1 fsc

42、si1 hdisk7 SP B0 active alive 0 0 0 fscsi0 hdisk10 SP B1 active alive 0 0 1 fscsi1 hdisk13 SP A0 active alive 0 0保存EMC PowerPath的设备数据库文件:powermt save手工恢复PowerPath通道powermt restore手工检查PowerPath通道powermt check监控PowerPath通道powermt watchRedhat Linux平台软件安装PowerPath安装安装需求PowerPath 5.0.0 host configuration

43、s for RHET 4.0DistributionProcessorKernelConfigurationsRHEL 4.0 U4 AS/ESX86 uniprocessor2.6.9-42configs/kernel-2.6.9-i686.configX86 multiprocessorconfigs/kernel-2.6.9-i686-smp.configconfgis/kernel-2.6.9-i686-hugemem.configIA64configs/ia64.configOpteron AMD64configs/kernel-2.6.9-x86_64-smp.configEM64

44、Tconfigs/kernel-2.6.9-x86_64-smp.configconfigs/kernel-2.6.9-x86_64-largesmp.configRHEL 4.0 U3 AS/ESX86 uniprocessor2.6.9-34configs/kernel-2.6.9-i686.configX86 multiprocessorconfigs/kernel-2.6.9-i686-smp.configconfgis/kernel-2.6.9-i686-hugemem.configIA64configs/ia64.configOpteron AMD64configs/kernel-

45、2.6.9-x86_64-smp.configEM64Tconfigs/kernel-2.6.9-x86_64-smp.configconfigs/kernel-2.6.9-x86_64-largesmp.configRHEL 4.0 U2 AS/ES32-bit X86 uniprocessor2.6.9-22configs/kernel-2.6.9-i686.config32-bit X86 multiprocessorconfigs/kernel-2.6.9-i686-smp.configconfgis/kernel-2.6.9-i686-hugemem.configIA64config

46、s/ia64.configEM64T, Opteron AMD64configs/kernel-2.6.9-x86_64-smp.configHBA driver requirementsLinux DistributionQLogic HBA DriverEmulex HBA DriverRHEL 4.0 U48.01.04-d77RHEL 4.0 U3 AS/ES8.01.02-d48RHEL 4.0 U2 AS/ES8.01.00c7File System SupportRHEL 4.0 U2, U3, U4 only Support ext2 & ext3 file system相关参

47、数修改The HBA driver used to access EMC devices can be statically loaded in the kernel or loaded into the kernel as a module.Enable the max_scsi_luns parameter in /etc/modprobe.conf使用Qlogic HBA卡,设置ql2xfailover和ConfigReguire参数为0在/etc/modprobe.conf文件中使用emulex HBA卡,设置lpfc_nodev_tmo参数为10在 /etc/modprobe.con

48、f文件中安装流程root用户登陆,将 POWERPATH软件包ftp到主机的/usr/emcsoft目录(本次安装的软件版本为57)用以下命令进行安装Linux下PowerPath分很多平台和Linux版本,请仔细选择当前的系统平台和Linux版本,本次安装的Linux为:Red Hat AS 4.0,i386平台,所以选择如下版本安装:EMCpower.LINUX-5.0.0-157.rhel.i386.rpm rpm ivh EMCpower.LINUX-5.0.0-157.rhel.i386.rpmlicense key在一张纸上, 和设备及软件光盘介质一起到货,通过以下命令注册POWE

49、RPATH,emcpreg install = EMC PowerPath Registration =Do you have a new registration key or keys to enter? n输入y,按回车继续。 Enter the registration key(s) for your product(s),one per line, pressing Enter after each key.After typing all keys, press Enter again.Key (Enter if done):输入powerpath注册码,然后按回车继续,成功后会显

50、示以下提示信息。1 key(s) successfully added.Key successfully installed.Navisphere Agent/Cli安装安装需求OSMinimum hardware requirementsMinimum software requirementsLinuxAn Intel-compatible, processor-based system capable of accepting PCI HBAs, with at least 200 MB of free disk space and 64 MB RAM.OSRed Hat 4.0 (32

51、- and 64-bit) U1 or U3Red Hat 3.0 (32-bit and 64-bit (single path only) (U5, U6, or U7)Red Hat 5.0 (32-bit and 64-bit)SuSE SLES 9 (SP1, SP2, or SP3) and SuSE SLES 10 (32-bit only)SuSE SLES 8 (SP2, SP3 , SP4(32-bit and 64-bit (single path only)MLSE 3.0 or 4.0Red Flag 4.1 or 5.0 (32-bit)AsianUX 1.0, 2

52、.0 SP1安装流程以 root用户登陆, 上传软件到/usr/emcsoft目录,(本次安装的为.24版本的Agent)然后输入以下命令:unzip NAVICLI_LINUX_V26.zip可以在该目录下找到软件名为:naviagentcli-.24-1.noarch.rpm输入以下命令安装agent rpm ivh naviagentcli-.24-1.noarch.rpm Preparing. # 100% 1:naviagentcli # 100% 2:navicli # 100%安装完成时,将提示安装成功可以用如下命令检查软件安装状态:rpm -qa | grep -i navic

53、linavicli-.24-1rpm -qa | grep -i naviagentclinaviagentcli-.24-1在/etc/Navisphere/agent.config文件中添加如下内容:systemSPA_IPAddresssystemSPB_IPAddress收工启动和停止Agent系统重启时将自动启动agnet, 手工启动可用如下的命令/etc/init.d/naviagent start/etc/init.d/naviagent stopLinux主机识别PowerPath管理的设备主机认盘Redhat linux主机认盘需要重启主机,重启以后通过以下命令可以看到磁盘f

54、disk l执行powermt命令识别POWERPATH设备powermt config检查磁盘路径, 正常结果CX3设备每个LUN有4个 path为alive状态;DMX3设备每个LUN有2个 path为alive状态powermt display dev=allPseudo name=emcpowercCLARiiON ID=CK200073100029 ODS_EPE_DB_1Logical device ID=6006016070111E006CEFDE9ED365DC11 LUN 3state=alive; policy=CLAROpt; priority=0; queued-IOs

55、=0Owner: default=SP B, current=SP A= Host - Stor - - I/O Path - - Stats # HW Path I/O Paths Interf. Mode State Q-IOs Errors= 0 qla2xxx sda SP A1 active alive 0 0 0 qla2xxx sdc SP B1 active alive 0 0 1 qla2xxx sde SP A0 active alive 0 0 1 qla2xxx sdg SP B0 active alive 0 0保存EMC PowerPath的设备数据库文件:powe

56、rmt save手工恢复PowerPath通道powermt restore手工检查PowerPath通道powermt check监控PowerPath通道powermt watchWindows2003平台软件安装PowerPath安装安装需求Supported Operating SystemsMinimum Service Pack and Disk Space RequiredWindows Server 2003 (32-bit)Windows Server 2003 (x64-bit)Windows Server 2003 (ia64-bit)Windows Server 200

57、3 R2 (32-bit)Windows Server 2003 R2 (x64-bit) Windows Server 2003 with SP1 Microsoft MPIO framework version 1.16 or greater Free disk space required: 10 MB安装流程在安装PowerPath之前,关闭所有的主机应用程序插入PowerPaht安装CD到CDROM,开始安装,首先选择安装语言环境,可选中文。因本次安装环境中没有连接 AX系列阵列,选“否”输入客户信息选择需要安装的一些阵列支持软件,因本次环境无其他阵列,选默认既可。点“安装”开始安装

58、接着选“是”安装当提示输入EMC Licensing 时,输入24位的License Key,点击添加, 点击确定。在下一个对话框里,点击完成, 将会提示你是否重起主机;重启后,可查看服务中“EMC PowerPath Service 4.6.1”为已启动,启动为自动。Navisphere Agent/Cli安装安装需求OSMinimum hardware requirementsMinimum software requirementsWindowsIntel-compatible PC with 64 MB of RAM and at least 30 MB of free disk sp

59、aceOSMicrosoft Windows Server 2003 (32-bit and 64-bit) (SP1 or SP2)Windows 2000 (SP4), Windows 2000 Advanced Server 9SP4) and Windows Longhorn Server (limited support).Note: All utilities are supported on IA64 systems as well. For iSCSI support, iSCSI initiator driver should be of version 2.4 or hig

60、her. Longhorn Server with MPIO enabled is not supported in the current version.安装流程以 Administrator用户登陆(确保有administrative 权限) 插入Server Support CD(和盘阵一起到货), 从主菜单中选择Install Products on Server 在Install Products 页中,选择Navisphere Host Agent;安装图示如下,本次安装版本为0,点击“Next”默认安装目录为“ C:Program FilesEMCNavisphere Agen

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论