给水课程设计计算说明书_第1页
给水课程设计计算说明书_第2页
给水课程设计计算说明书_第3页
给水课程设计计算说明书_第4页
给水课程设计计算说明书_第5页
已阅读5页,还剩31页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

给水设计计算说明书学院:环境科学学与工程学院院专业:给水排水水工程专业级别:2000级指导教师:姓名::学号::时间::200年6月10日目录Ⅰ.给水管道道工程课程设设计任务书··············································2一.基本资料料·······························································2二.给水管网设设计任务·····················································3Ⅱ.给水管道设设计计算说明明···················································5一.设计用水量量及其调节计计算··············································55(1)设计用水水量计算·······················································55(2)设计用水水量变化规律律的确定·············································6(3)计算清水水池、水塔调调节容积·············································7二.设计流量分分配与管径设设计··············································99(1)管网布置置定线··························································9(2)平差前管管网设计数据据···················································9三.水泵扬程与与水塔高度设设计·············································111(1)最不利点点的确定······················································111(2)水泵的选选用···························································14(3)水塔高度度设计························································116四.管网设计校校核·························································166(1)消防工况况校核························································116(2)最大转输输工况校核····················································18(3)事故工况况校核························································220五.成果图绘制制····························································21Ⅲ.给水设计计小结·····························································211给水管道工程课课程设计任务务书一基本资料(一)自然条件件1ZQ镇规划划面积平面图图1张。2地理位置及及地形特点::ZQ镇位于浙江江省宁波市境境内,规划杭杭州湾高速公公路的东侧,329国道贯穿南南北。规划用用地面积2.16km2。全镇地势北高南低,西高东东低,海拔在4.5~66.5m之间。3规划中该镇镇由329国道分为南南北两区,南南面为居民生生活区,北面面为工业区。居居民区人口密密度为200人/hm2,建筑多为2~3层,最高为6层;规划工工业区主要为为电器、精密密机械制造业业,在计算用用水量时,可可折合人口密密度为100人/hm2,按照居民民区的计算方方式进行,最最低服务水头头要求为20m。3气温:ZQQ镇位于北亚热热带南缘,属属季风型气候候。冬夏稍长长,春秋略短短。温暖湿润润,气温变幅幅小。年平均均气温16.1℃,1月平均气温温最低,历年年平均4.0℃,7月平均气温温最高,历年年平均28.2℃,极端最低低气温-9.3℃,极端最高高气温39.1℃。冰冻线深度0.6m。4降雨:年平平均降水量(含雨、雪、冰冰雹)12599.6mm,年降水量量少于1000mmm的少水年占15%,大于1500mmm的丰水年占17.6%。平均10年中有大旱旱、大涝各一一年。降水量量年内分配不不均匀,春雨雨、梅雨、秋秋雨与伏旱、秋秋冬旱交替,降降水最高峰在在9月,平均172.44mm,占全年的14%,最高曾达468.33mm。梅雨期间间多连阴雨。5风:冬季盛盛行西北到北北风,夏季盛盛行东到东南南风,春季转转夏季稍早,秋秋季转冬季较较迟。全年以以东风为主。年年平均风速3m/s,各月差异异不大。年有有较明显影响响台风1~2次。6湿度:本区区年相对湿度度是78~833%,属比较湿湿润。夏季因因受副高压影影响,气温较较高,虽有充充沛水汽,但但相对湿度不不是很大,一一般情况最大大相对湿度在在6月,达84%,冬季相对对湿度最低,春春季介于冬夏夏之间。7河流由西南南流至东北方方向,常水位位4.00m;地下水位位埋深平均为为2.0m;土壤为沙沙质黏土;主主要马路均为为沥青铺设;;地震烈度7度。(二)给水规划划资料1ZQ镇供水水来自师桥水水厂,接管点点在环镇西路路的西南角,来来水水压为10m水头,接管管处管道按照照全天均匀供供水考虑。2该镇生活用用水量最高日日时变化系数数见表1;工厂生产产用水变化系系数Kd=1,Kh=1..10。表1居民生活活用水逐时变变化系数时段0~11~22~33~44~55~66~77~8用水量系数(%%)1.100.700.901.101.303.916.615.84时段8~99~1010~1111~1212~1313~1414~1515~16用水量系数(%%)7.046.697.177.316.625.233.594.76时段16~1717~1818~1919~2020~2121~2222~2323~24用水量系数(%%)4.245.996.975.663.052.011.420.79表2工业用水水逐时变化系系数时间段0-11-22-33-44-55-66-77-8用水量系数(%%)3.443.443.443.654.084.324.324.42时间段8-99-1010-1111-1212-1313-1414-1515-16用水量系数(%%)4.344.364.364.594.54.454.434.43时间段16-1717-1818-1919-2020-2121-2222-2323-24用水量系数(%%)4.454.364.344.344.354.293.653.653生活区和工工业区占地面面积分配见表表2。表2占地面积积分配情况区域建筑用地道路和车场绿地居民区25%25%50%工业区28%25%47%二给水管网设设计任务(一)设计计算算1计算最高日日用水量,并并分别计算各各种用水量,编编制城镇24h逐时用水量量图表。2进行管网定定线布置,确确定调节构筑筑物形式及位位置。3进行管网水水力计算,确确定各管段管管径。4确定水塔高高度和二级泵泵站扬程,拟拟定水泵工作作制度。5计算管网个个节点的自由由水头及最高高时供水水压压线。(二)编制计算算说明书一份份1设设计任务2基基本资料、设设计依据及参参考资料3设设计说明(1)管管网定线说明明及简图(2)Qd考虑了哪些些用水量;设设计工况和校校核工况,每每一工况设计计流量;24h变化曲线,根根据该曲线,你你可以得出哪哪些设计信息息。(3)管管网水力计算算成果。环网平平差依据及成成果,最不利利点选择。设计工工况(Qhamx)及及校核工况(消消防、最大转转输)成果图图。(4)泵泵型选择(主主要参数)及及运行方式(二二级)。所选泵泵型扬程是否否满足校核工工况要求。(5)管管网上附属构构筑物说明::清水池、水水塔容积计算算成果及其尺尺寸、水位、保保证消防水量量不被动用的的措施等。4设设计小结(三)绘制图纸纸1在在所绘的城镇镇地形图上绘绘制给水管网网平面布置图图。2最最高时流量工工况及给水管管网等水压线线图。3最最不利管线水水力坡度线图图。4绘绘制一个环路路的节点详图图及其材料表表。给水管道设计计计算说明一、设计用水量量及其调节计计算(1)设计用水水量计算城市最高日用水水量包括综合合生活用水量量、工业企业业生产用水、浇浇洒道路和大大面积绿化用用水、未预见见水量和管网网漏失水量。消消防用水不累累计到设计总总用水量,仅仅作为设计校校核使用。ZQ镇规划用地地面积2.16km2,其中居民民区面积1.38km2,工业区0.78kkm2。该镇居民民区人口为27600人,工业区区人口为7800人,总人口口为35400人。参考《室室外给水设计计规范》,浙浙江省分区处处于一区,ZQ镇为人口小于50万的中小城市。查查规范得该镇镇综合生活用用水定额为220~3370L//(cap·d),由于规规划工业区主主要为电器、精精密仪器制造造业等用水量量较大的产业业,所以本设设计取用水定定额为300LL/(cap·d)。城市最高日综合合生活用水量量最高日综合合生活用水量量:2、工业用水量量(用居民区区的方法计算算)3、浇洒道路和和大面积绿化化用水量区域面积km2道路和车场面积km2绿地面积km2居民区1.3825%0.34550%0.69工业区0.7825%0.19547%0.37总2.160.541.06由表可知,该镇镇浇洒道路面面积为0.54kmm2,用水量定定额采用2.5L/(m2·d),每天浇洒洒一次,大面面积绿化面积积1.06km2,用水量定定额采用2.0L/(m2·d)。4、未预见水量量和管网漏失失水量取上述三类用水水量总和的220%计算。5、最高日设计计用水量取:(2)设计用水水量变化规律律的确定城镇24h逐时时用水变化系系数时段Kh(生活)生活区总用水Kh(工业)工业区总用水每小时总用水占最高日用水量量百分数Kh(总)%m3/h%m3/hm3/h%%0~11.10138.903.44147.27286.161.690.411~20.7088.393.44147.27235.661.390.332~30.90113.643.44147.27260.911.540.373~41.10138.903.65156.26295.151.750.424~51.30164.154.08174.66338.822.000.485~63.91493.724.32184.94678.654.010.966~76.61834.644.32184.941019.5886.031.457~85.84737.424.42189.22926.645.481.328~97.04888.944.34185.801074.7446.361.539~106.69844.754.36186.651031.4006.101.4610~117.17905.364.36186.651092.0116.461.5511~127.31923.034.59196.501119.5336.621.5912~136.62835.914.5192.651028.5556.081.4613~145.23660.394.45190.50850.905.031.2114~153.59453.314.43189.65642.963.800.9115~164.76601.054.43189.65790.694.681.1216~174.24535.384.45190.50725.894.291.0317~185.99756.364.36186.65943.015.581.3418~196.97880.104.34185.801065.9006.301.5119~205.66714.694.34185.80900.485.331.2820~213.05385.124.35186.22571.353.380.8121~222.01253.804.29183.65437.462.590.6222~231.42179.303.65156.26335.561.980.4823~240.7999.753.65156.26256.011.510.36总100100100总用水量m3//d12627428116908Kh=24×6.62/100=1.595.35%1.80%4.17%Kh=24×6.62/100=1.595.35%1.80%4.17%由上图,最高时时是上午11~12时,最高时时用水量百分分数为6.62%,时变化系系数为1.59,最高日用用水量为。则最高时用水量量为:(3)计算清水水池、水塔调调节容积。泵站供水曲线,分分为两级,第第一级为6点到21点,供水量量为5.35%,第二级为为从22点到5点,供水量量为1.80%,最高日泵泵站总供水量量为:5.35%%×16+1.80%%×8=100%清水池与水塔调调节容积计算算见下表:小时给水处理供水量量(%)供水泵站供水量量(%)清水池调节容积积计算(%)水塔调节容积计计算(%)设置水塔不设水塔设置水塔(1)(2)(3)(4)(2)-(3)∑(3)-(4)∑0~14.171.81.692.372.370.110.111~24.171.81.392.374.740.410.522~34.161.81.542.367.100.260.773~44.171.81.752.379.470.050.834~54.171.82.002.3711.84-0.200.625~64.165.354.01-1.1910.651.341.966~74.175.356.03-1.189.47-0.681.287~84.175.355.48-1.188.29-0.131.158~94.165.356.36-1.197.10-1.010.149~104.175.356.10-1.185.92-0.75-0.6110~114.175.356.46-1.184.74-1.11-1.7211~124.165.356.62-1.193.55-1.27-2.9912~134.175.356.08-1.182.37-0.73-3.7213~144.175.355.03-1.181.190.32-3.4014~154.165.353.80-1.190.001.55-1.8615~164.175.354.68-1.18-1.180.67-1.1816~174.175.354.29-1.18-2.361.06-0.1317~184.165.355.58-1.19-3.55-0.23-0.3518~194.175.356.30-1.18-4.73-0.95-1.3119~204.175.355.33-1.18-5.910.02-1.2820~214.165.353.38-1.19-7.101.970.6921~224.171.82.592.37-4.73-0.79-0.1022~234.171.81.982.37-2.36-0.18-0.2823~244.161.81.512.360.000.290.00累计100100.00100.00调节容积=188.94调节容积=5..68清水池调节容积积为:11..84-(-7.10)=18.94(%)水塔调节容积为为:1.96-(-3.72)=5.68(%)清水池设计有效效容积;W1——清水池池调节容积,m3;W2——消防贮贮备水量,m3,按2h室外消防防用水量计算算;W3——给水处处理系统生产产自用水量,m3,一般取最高日用水量的5%~10%,本计算不考虑;W4——安全贮贮备水量,m3。2、水塔设计有有效容积;W1——水塔调调节容积,m3;W2——室内消消防贮备水量量,m3,按最高日用用水量的2%%~3%计算算。最高日设计用水水量为:17000(m3/d),管网中中设置水塔供水泵站设计供供水流量为::17000×55.35%××1000/3600=253(L/s);水塔的设计供水水流量为:17000×(6.62%-5.35%)×1000/3600=60(L/s);水塔的最大进水水流量(20~21点,称为最最高转输时)为为:17000×(5.35%-3.38%)×1000/3600=94(L/s)。二、设计流量分分配与管径设设计(1)管网布置置定线管网布置如设计计图所示。(2)平差前管管网设计数据据先进行流量分配配,得出计算算管径;把计计算管径标准准化之后,略略作调整,得得到下表数据:管段或者节点编编号管长m管段配水长度mm管段沿线流量L/s节点设计流量计计算L/s供水流量节点流量123600.00252.83-252.833269834912.4422.3834292157.6414.64440140114.2910.97516400.0010.4461851856.5960.02-60.0271241244.425.5181831836.525.47964064022.8119.261054254219.3132.301142042014.9723.291237637613.4014.181342542515.1414.271457157120.3523.89152582589.1915.451633633611.978.641734534512.2914.151829529510.5123.71192322328.2715.89202532539.0217.092154154119.2821.332253753719.14/2335535512.65/2460460421.52/2534034012.12/262532539.02/合计97438780312.85312.850.00注明:1、按管段配水水长度分配沿沿线流量的比比流量计算::,,2、管段流量初初分配时,节节点(2)处将水塔塔和泵站提供供的总水量平平均分配;管管段【18】为提供工工业区用水量量的输水管,采采用单管且流流量平均分配配;对于垂直直于主要供水水方向的管段段【2】、【9】、【10】和【14】处于安全全考虑,其上上仍承担一些些水量;对于于供水方向和和供水重要性性基本相同的的管段,分配配相近水量。3、为了平差的的需要,粗略略确定管径时时经济流速为为0.9m//s;4、水厂出水输输水管【1】为两条DN500mmm管道并行铺铺设;5、水塔最大进进水流量为,故故水塔输水管管【5】和27】为管径为两条DN4000mm管道并行铺铺设。三、水泵扬程与与水塔高度设设计(1)最不利点点的确定首先考虑不设泵泵站的情况,对对管网进行平平差,以确定定最不利点。以管网起点【1】作为定压节点进行平差,其水头为4.95+28.00=32.95m。结果如下:1.1节点点数据编号地面标高已知水压节点流量节点水压自由水头mmLPSmm14.9532.95-252.81132.952825.1722.3832.6927.523614.6432.626.646.6110.9732.6626.0556.5510.4432.7726.2266.78-60.0532.8126.0376.35.5132.3826.0886.275.4732.3626.0996.0219.2632.3626.34105.1332.332.1827.0511523.2932.0427.04125.6514.1831.5125.86135.6514.2732.0726.4214523.8932.227.2155.1715.4531.926.73165.678.6431.6926.02175.6614.1531.5825.92184.523.7131.3926.89195.5615.8930.825.24205.617.0930.8925.29214.521.3331.5271.2管段段数据编号长度管径流量流速单位水头损失mmmLPSm/sm/km1236500126.40.641.12269840021.720.170670.180640.270.295164400-30.030.240.23618520015.970.512.11712430010.460.150.1381833004.990.070.03964030015.480.220.2810542300-14.980.210.261142020012.050.381.25123761002.130.271.481342530016.40.230.311457140060.650.480.851525830029.750.420.9316336500148.050.751.51734530020.370.290.4618295500116.260.590.961923230028.830.410.872025330020.190.290.45215412006.040.190.35225371001.810.231.092335530014.080.20.232460430031.170.441.012534040071.980.571.172625330019.480.280.422716440030.030.240.2328236500126.40.641.12由此可以看出,最最不利点为节节点(19),考虑最不不利的情况,即即六层楼在此此点上的情况况,则节点(19)的自由水头头至少为288.00m。选此点为为定压节点进进行平差,确确定水泵所需需扬程:1.3节点点数据编号地面标高已知水压节点流量节点水压自由水头mmLPSmm14.95-252.81135.7130.7625.1722.3835.4530.283614.6435.3629.3646.6110.9735.4228.8156.5510.4435.5328.9866.78-60.0535.5728.7976.35.5135.1428.8486.275.4735.1228.8596.0219.2635.1229.1105.1332.334.9429.8111523.2934.829.8125.6514.1834.2728.62135.6514.2734.8329.1814523.8934.9629.96155.1715.4534.6629.49165.678.6434.4528.78175.6614.1534.3428.68184.523.7134.1529.65195.5628.0015.8933.5628205.617.0933.6528.05214.521.3334.2629.761.4管段段数据:编号长度管径流量流速单位水头损失mmmLPSm/sm/km1236500126.40.641.12269840021.720.170670.180640.270.295164400-30.030.240.23618520015.970.512.11712430010.460.150.1381833004.990.070.03964030015.480.220.2810542300-14.980.210.261142020012.050.381.25123761002.130.271.481342530016.40.230.311457140060.650.480.851525830029.750.420.9316336500148.050.751.51734530020.370.290.4618295500116.260.590.961923230028.830.410.872025330020.190.290.45215412006.040.190.35225371001.810.231.092335530014.080.20.232460430031.170.441.012534040071.980.571.172625330019.480.280.422716440030.030.240.2328236500126.40.641.12(2)水泵的选选用根据上面的平差差结果可得,水泵所在【1】节点自由水头需要30.76m,考虑水塔转输以及局部水头损失的影响,所选水泵的扬程也应适当增大,这里取其设计扬程为32.00m。参考《给水排水水设计手册》第11册《常用设备》,则选则三台250S39A型水泵,两用一备。水泵参数如下:型号:250SS39A主要性能参数::流量Q(m3//h)扬程H(m)效率n(﹪)转速(r/miin)32435.574145046830.5795762577泵站设计完毕后后,再次平差差,则实际管管网平差结果果为:2.1节点数数据编号地面标高已知水压节点流量节点水压自由水头mmLPSmm14.95-252.8114.95025.1722.3835.6330.463614.6435.5529.5546.6110.9735.628.9956.5510.4435.7229.1766.78-60.0535.7628.9876.35.5135.3329.0386.275.4735.3129.0496.0219.2635.3129.29105.1332.335.133011523.2934.9929.99125.6514.1834.4628.81135.6514.2735.0229.3714523.8935.1530.15155.1715.4534.8529.68165.678.6434.6428.97175.6614.1534.5328.87184.523.7134.3429.84195.5615.8933.7528.19205.617.0933.8428.24214.521.3334.4529.952.2管段数数据编号长度管径流量流速单位水头损失mmmLPSm/sm/km1236500126.40.641.12269840021.720.170670.180640.270.295164400-30.030.240.23618520015.970.512.11712430010.460.150.1381833004.990.070.03964030015.480.220.2810542300-14.980.210.261142020012.050.381.25123761002.130.271.481342530016.40.230.311457140060.650.480.851525830029.750.420.9316336500148.050.751.51734530020.370.290.4618295500116.260.590.961923230028.830.410.872025330020.190.290.45215412006.040.190.35225371001.810.231.092335530014.080.20.232460430031.170.441.012534040071.980.571.172625330019.480.280.422716440030.030.240.2328236500126.40.641.12由上表结果可以以看出,节点(19)的自由水水头为28.199m,其他各点自自由水头自然然满足要求。(3)水塔高度度设计加入泵站平差后后,水塔所在在节点(6)节点水压为35.766m,高程为6..78m,水塔水柜柜设计有效水水深取为2.5m,则水塔高度度:。四、管网设计校校核(1)消防工况况校核该镇人口数不到到5.0万人,考虑两两处同时发生生火灾的可能能性,每处水水量为。在最最不利点节点点(19)和离水塔较较远的较不利利点节点(13)同时各加上上的消防流量量,消防总流流量由泵站提提供,其他节点流流量与最高时时相同。采用用水头校核法法。将19号点定为为定压节点,节节点水压按低低压消防考虑虑为,平差结果如如下:1.1节点点流量编号地面标高已知水压已知流量节点水压自由水头mmLPSmm14.95-302.8114.95025.1722.3831.1625.993614.6431.125.146.6110.9731.124.4956.5510.4431.1224.5766.78-60.0531.2724.4976.35.5130.9524.6586.275.4730.9324.6696.0219.2630.9224.9105.1332.330.525.3711523.2930.2425.24125.6514.1829.623.95135.6539.2729.6624.0114523.8930.3425.34155.1715.4530.124.93165.678.6429.8424.17175.6614.1529.6824.02184.523.7129.2224.72195.5615.5640.8928.1312.57205.617.0928.3822.78214.521.3329.4524.951.2管段段数据编号长度管径流量流速单位水头损失mmmLPSm/sm/km1236500151.40.771.57269850030.730.160.0834295009.490.050.01440150020.460.10.045164300-30.030.420.94618530029.150.410.89712440023.640.190170.140.09964030024.490.350.6510542300-20.830.290.481142020013.490.431.54123761000.690.090.181342530039.960.571.61457140079.80.641.421525830025.590.360.716336500169.890.871.941734530015.950.230.2918295500141.260.721.381923230032.60.461.12025330023.960.340.62215412009.810.310.862253720015.630.52.032335530025.260.360.692460430042.350.61.782534040093.210.741.892625330029.530.420.912716430030.030.420.9428236500151.40.771.57由平差结果,各各点自由水头头均大于10m,满足消防防要求,故不不需重新校核核。(2)最大转输输工况校核最大转输发生在在11-12时,此时用用水量为最高高日用水量的的6.62%%,水塔进水水量为最高日日用水量的55.35%--3.38%=1.97%%,即94(L/s)。水塔最高高转输时有效效水深取为11.5m。以水塔所在节点点(6)作为定压压节点,节点点水头=35..76+1.5=37..26m,以节点(6)定压节点点进行平差,结结果如下:2.1节点点流量编号标高已知水压已知流量节点水压自由水头mmLPSmm14.95-253.5664.9530.925.1711.4135.5930.42367.4735.0429.0446.615.5934.8528.2456.555.3234.6928.1465.337.269434.3429.0476.32.8134.8528.5586.272.7934.8828.6196.029.8234.9328.91105.1316.4735.3330.211511.8835.3230.32125.657.2335.1729.52135.657.2835.3729.7214512.1835.4130.41155.177.8835.2530.08165.674.4135.1929.52175.667.2235.1629.5184.512.0935.130.6195.568.134.9329.37205.68.7234.9629.36214.510.8835.1330.632.2管段段流量编号长度管径流量流速单位水头损失mmmLPSm/sm/km1236500126.780.651.132698500103.870.530.783429500-76.840.390.454401500-71.240.360.395164300470.662.166185300-28.080.40.837124400-30.890.250.248183400-33.680.270.299640300-23.940.340.6210542300-3.220.050.02114202006.030.190.35123761001.20.150.52134253008.480.120.091457140035.350.280.311525830019.560.280.4316336500102.930.520.771734530014.680.210.251829550059.290.30.281923230014.70.210.252025330010.30.150080.10.1225371000.920.120.31233553007.180.10.072460430015.90.220.292534040036.710.290.34262533009.930.140.1227164300-470.662.1628236500-126.7880.651.13由平差结果可知知节点【1】(水泵所所在节点)水水压为35.855m>32m,所选泵站站能满足供水水压力要

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论